Based on the“three box”exergy analysis model,a black box-gray box hierarchical exergy analysis and evaluation method is put forward in this paper,which is applied to evaluate the power generation technology of diffe...Based on the“three box”exergy analysis model,a black box-gray box hierarchical exergy analysis and evaluation method is put forward in this paper,which is applied to evaluate the power generation technology of differential pressure produced by natural gas expansion.By using the exergy analysis theory,the black box-gray box hierarchical exergy analysis models of three differential pressure power generation technologies are established respectively.Firstly,the“black box”analysis models of main energy consuming equipment are established,and then the“gray box”analysis model of the total system is established.Based on the calculation results of exergy analysis indexes,the weak energy consumption equipment in the whole power generation process is accurately located.Taking a gas field in southwest China as an example,the comprehensive energy consumption evaluation of the three power generation technologies is carried out,and the technology with the best energy consumption condition among the three technologies is determined.Finally,the rationalization improvement measures are put forward from improving the air tightness,replacing the deflector and reducing the flow loss.展开更多
This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data cen...This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.展开更多
基金financially supported by the National Natural Science Foundation of China(52074089 and 51534004)Natural Science Foundation of Heilongjiang Province of China(LH2019E019)。
文摘Based on the“three box”exergy analysis model,a black box-gray box hierarchical exergy analysis and evaluation method is put forward in this paper,which is applied to evaluate the power generation technology of differential pressure produced by natural gas expansion.By using the exergy analysis theory,the black box-gray box hierarchical exergy analysis models of three differential pressure power generation technologies are established respectively.Firstly,the“black box”analysis models of main energy consuming equipment are established,and then the“gray box”analysis model of the total system is established.Based on the calculation results of exergy analysis indexes,the weak energy consumption equipment in the whole power generation process is accurately located.Taking a gas field in southwest China as an example,the comprehensive energy consumption evaluation of the three power generation technologies is carried out,and the technology with the best energy consumption condition among the three technologies is determined.Finally,the rationalization improvement measures are put forward from improving the air tightness,replacing the deflector and reducing the flow loss.
基金Thanks for the support of Hunan postdoctoral fund(Number:198514)。
文摘This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.