<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediat...<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.展开更多
Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract...Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony(ZXRoO)or monofocal IOLs were enrolled.The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively.Results:The ZXR00 group achieved signifcantly better intermediate(P=0.044)and near(P=0.017)visual acuity(VA)than the monofocal group.Two groups had similar uncorrected and corrected distance VA(P>0.05,respectively).The dynamic defocus curve revealed a smoother decline from 0.0 D to-2.0 D in the ZXRo0 group.Defocused dynamic VA in the ZXR00 group was significantly better(P<0.05)except at 0.0 D(P=0.724)and-0.5 D(P=0.176).The area under the curve(P=0.002)and corrected dynamic vision accommodation(P=0.001)derived from the dynamic defocus curves were better in the ZxRoo group.A positive correlation was observed between defocused dynamic and static VA in both groups(P<0.001).Multiple linear regression analysis indicated that defocused static VA and cor-rected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from-1.0 D to-3.0 D(P<0.05).Conclusions:The EDOF IOL provided similar distant vision,better intermediate and near vision,and a better overall dynamic defocus curve than the monofocal IOL.The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.展开更多
文摘<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.
基金This work was supported by Bejing Municipal Science and Technology Commission(Grant No.7202229)Peking University Medicine Fund of Fostering Young Scholars'Scientific&Technological Innovation(Grant No.BMU2022PYB022)。
文摘Background:The aim of the study was to compare the dynamic defocus curve on patients post-implantation of the extended depth-of-focus(EDOF)and monofocal intraocular lens(IOL).Methods:A total of 62 age-related cataract patients receiving phacoemulsification with implantation of TECNIS Symfony(ZXRoO)or monofocal IOLs were enrolled.The binocular static and dynamic defocus curves with corrected distance visual acuity were evaluated at one month postoperatively.Results:The ZXR00 group achieved signifcantly better intermediate(P=0.044)and near(P=0.017)visual acuity(VA)than the monofocal group.Two groups had similar uncorrected and corrected distance VA(P>0.05,respectively).The dynamic defocus curve revealed a smoother decline from 0.0 D to-2.0 D in the ZXRo0 group.Defocused dynamic VA in the ZXR00 group was significantly better(P<0.05)except at 0.0 D(P=0.724)and-0.5 D(P=0.176).The area under the curve(P=0.002)and corrected dynamic vision accommodation(P=0.001)derived from the dynamic defocus curves were better in the ZxRoo group.A positive correlation was observed between defocused dynamic and static VA in both groups(P<0.001).Multiple linear regression analysis indicated that defocused static VA and cor-rected dynamic vision accommodation were significant influential factors for the defocused dynamic VA from-1.0 D to-3.0 D(P<0.05).Conclusions:The EDOF IOL provided similar distant vision,better intermediate and near vision,and a better overall dynamic defocus curve than the monofocal IOL.The dynamic defocus curve may be comprehensively applied to evaluate the all-distance dynamic visual performance post-cataract surgery.