Weatherability Studies on External Insulation Thermal System of Expanded Polystyrene Board,Polystyrene Granule and Polyurethane Foam 被引量:5
1
作者 尹秀琴 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2010年第6期1027-1032,共6页
Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,... Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,polystyrene granule mortar and polyurethane foam in order to study the weatherablility of external thermal insulation system(ETIS).The change rules of adhesive strength were hereby studied at different time period of atmospheric exposure tests.The experimental results show that the adhesive strength of three kinds of ETIS changes a little during high temperature-spraying water cycle,but the adhesive strength of ETIS with EPS board decreases significantly after heating-refrigeration cycle.The lowering rate of adhesive strength with painting finishes is obviously faster than that of tile finishes for ETIS of EPS board during heating-refrigeration cycle.The weatherability of ETIS with EPS board is worse than the other two,and ETIS of polystyrene granule mortar and polyurethane foam are more suitable than ETIS of EPS board in cold area. 展开更多
关键词 external thermal insulation system EPS board polystyrene granule atmospheric exposure tests adhesive strength
下载PDF
Impact of light-weight external thermal insulation materials on building surrounding thermal environment in summer 被引量:6
2
作者 李楠 罗国志 +1 位作者 李百战 黄彦祺 《Journal of Central South University》 SCIE EI CAS 2012年第6期1639-1644,共6页
The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick... The method for calculating wall surface heat storage coefficient was introduced,and the coefficients of several common walls with light-weight external thermal insulation materials and the traditional solid clay brick wall were calculated.In order to study the impact of light-weight external thermal insulation materials,a contrasting experiment was carried out between an external insulated room and an uninsulated room in August,2010,in Chongqing,China.The result shows that outside surface heat storage coefficient of the insulated wall is much less than that of the traditional wall.However,during sunny time,the surface temperature of external walls of the insulated room is obviously higher than that of the uninsulated room.In different orientations,due to different amounts of solar radiation and being irradiated in different time,the contrasting temperature difference(CTD) appears different regularity.In a word,using light-weight external thermal insulation materials has a negative impact on building surrounding thermal environment and people's health.Finally,some suggestions on how to eliminate the impact,such as improving the surface condition of the building envelop,and plating vertical greening,are put forward. 展开更多
关键词 surface heat storage coefficient external thermal insulation BUILDING thermal environment building envelop
下载PDF
Externalized conductors and insulation failure in Biotronik defibrillator leads: History repeating or a false alarm?
3
作者 Elia De Maria Ambra Borghi +2 位作者 Lorenzo Bonetti Pier Luigi Fontana Stefano Cappelli 《World Journal of Clinical Cases》 SCIE 2017年第2期27-34,共8页
Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique"... Conductor externalization and insulation failure are frequent complications with the recalled St. Jude Medical Riata implantable cardioverter-defibrillator(ICD) leads. Conductor externalization is a "unique" failure mechanism: Cables externalize through the insulation("inside-out" abrasion) and appear outside the lead body. Recently, single reports described a similar failure also for Biotronik leads. Moreover, some studies reported a high rate of electrical dysfunction(not only insulation failure) with Biotronik Linox leads and a reduced survival rate in comparison with the competitors. In this paper we describe the case of a patient with a Biotronik Kentrox ICD lead presenting with signs of insulation failure and conductor externalization at fluoroscopy. Due to the high risk of extraction we decided to implant a new lead, abandoning the damaged one; lead reimplant was uneventful. Subsequently, we review currently available literature about Biotronik Kentrox and Linox ICD lead failure and in particular externalized conductors. Some single-center studies and a nonprospective registry reported a survival rate between 88% and 91% at 5 years for Linox leads, significantly worse than that of other manufacturers. However, the preliminary results of two ongoing multicenter, prospective registries(GALAXY and CELESTIAL) showed 96% survival rate at 5 years after implant, well within industry standards. Ongoing data collection is needed to confirm longer-term performance of this family of ICD leads. 展开更多
关键词 IMPLANTABLE cardioverter DEFIBRILLATOR Biotronik IMPLANTABLE cardioverter DEFIBRILLATOR LEAD externalized CONDUCTORS insulation failure
下载PDF
Finite Element Analysis of External Thermal Insulation Composite System:Thin Rendered Expanded Polystyrene Board
4
作者 薄海涛 李惠强 尹秀琴 《Journal of Southwest Jiaotong University(English Edition)》 2009年第4期325-329,共5页
The finite element model of an external thermal composite insuiation system, thin rendered expanded polystyrene ( EPS ) board, was built with ANSYS 1.0, which had two forms: one with window and one without window. ... The finite element model of an external thermal composite insuiation system, thin rendered expanded polystyrene ( EPS ) board, was built with ANSYS 1.0, which had two forms: one with window and one without window. The finite element analysis results show that the EPS board had very good insulation capacity at both high or low temperature, stress concentration was produced in the center of wall and around window, and the maximum deformation was observed at the edge of board and the minimum deformation was in the center. 展开更多
关键词 external thermal insulation system Finite element Stress concentration DISPLACEMENT
下载PDF
THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS 被引量:1
5
作者 李忠 冯允平 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期7-10,15,共5页
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ... Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique. 展开更多
关键词 gas insulated switchgear partial discharge ultra high frequency finite-difference time-domain (FDTD) method MEASUREMENT external sensor
下载PDF
Switching Impulse Strength of ±800 kV UHVDC Transmission Line Air Gap Insulation Under High Altitude Condition 被引量:3
6
作者 LIAO Yongli GAO Chao +2 位作者 LI Ruihai WANG Guoli MA Yi 《高电压技术》 EI CAS CSCD 北大核心 2012年第12期3161-3165,共5页
关键词 高压直流输电线路 缺口冲击强度 空气间隙 绝缘特性 开关脉冲 高海拔 伏特 平面布置
下载PDF
长时间工作固体火箭发动机长尾喷管外绝热装置设计
7
作者 王相宇 向进 +5 位作者 章惠君 王鹍鹏 余小波 朱雯娟 刘梦珂 马以博 《固体火箭技术》 CAS CSCD 北大核心 2024年第5期629-637,共9页
固体火箭发动机长尾喷管周围一般安装有电子仪器,故而对喷管壳体表面温度有严格的限制。对于某长时间工作的发动机,为满足喷管壳体表面温度要求,同时降低消极质量,设计了一种新型双腔外绝热装置,以实现在较小的消极质量下具有较好的绝... 固体火箭发动机长尾喷管周围一般安装有电子仪器,故而对喷管壳体表面温度有严格的限制。对于某长时间工作的发动机,为满足喷管壳体表面温度要求,同时降低消极质量,设计了一种新型双腔外绝热装置,以实现在较小的消极质量下具有较好的绝热性能。对该绝热装置进行了内流场及传热计算分析,而后进行了绝热结构优化及试验验证。结果表明:该双腔外绝热装置可以将长时间工作固体火箭发动机长尾喷管外壁温度从483℃降低至103℃,降低约78.7%;而采用同等材料同等质量的常规外防护装置只能从483℃降低至227℃,降低约53.0%;而要达到相同的防护效果,同等材料常规外防护装置的质量将增加约160%。双腔外绝热装置中段及尾端处温度随时间变化趋势与实测结果吻合较好,有望应用于其他长时间工作发动机。 展开更多
关键词 固体火箭发动机 长时间工作 长尾喷管 外绝热装置
下载PDF
外墙保温一体化系统黏结性能影响因素及机理研究 被引量:1
8
作者 王娟 季良 董庆广 《绿色建筑》 CAS 2024年第4期125-128,135,共5页
外墙保温系统是建筑节能的主要路径之一,建筑外墙保温一体化系统是目前上海市主流应用的外墙保温系统。基于外墙保温一体化系统应用现状,分析了不同类型界面处理剂,不同施工环境条件和拉拔尺寸等因素对外墙保温一体化系统黏结性能的影... 外墙保温系统是建筑节能的主要路径之一,建筑外墙保温一体化系统是目前上海市主流应用的外墙保温系统。基于外墙保温一体化系统应用现状,分析了不同类型界面处理剂,不同施工环境条件和拉拔尺寸等因素对外墙保温一体化系统黏结性能的影响规律。研究成果对促进外墙保温一体化系统性能提升、保障建筑外立面安全具有指导意义。 展开更多
关键词 外墙保温一体化系统 拉伸黏结强度 影响因素 微观机理
下载PDF
高海拔环境下压接式半导体器件的外绝缘特性
9
作者 任成林 鲁翔 +3 位作者 闫旭阳 孙帮新 程周强 谢文杰 《半导体技术》 CAS 北大核心 2024年第10期946-952,共7页
压接式半导体器件作为柔性直流输电工程中的核心器件,对电网系统的稳定性和可靠性具有重要意义。目前,关于压接式半导体器件在高海拔环境下外绝缘特性的研究尚且不足,针对市场上主流半导体器件厂家的器件开展外绝缘试验,研究不同海拔环... 压接式半导体器件作为柔性直流输电工程中的核心器件,对电网系统的稳定性和可靠性具有重要意义。目前,关于压接式半导体器件在高海拔环境下外绝缘特性的研究尚且不足,针对市场上主流半导体器件厂家的器件开展外绝缘试验,研究不同海拔环境下半导体器件在不同电压类型下的间隙放电特性和在不同湿度下的沿面绝缘特性。在人工气候罐中模拟的2000、3800和4500 m高海拔环境下,对5种器件进行了雷电冲击电压试验、操作冲击电压试验、直流电压试验及60%、70%和80%湿度下人工污秽试验。试验结果表明,研究的5种器件均能满足3种海拔下的外绝缘要求,且设计裕度均大于17.6%;同时根据试验数据计算出海拔修正系数,对高海拔环境下空气间隙修正具有指导意义。 展开更多
关键词 压接式半导体 高海拔 外绝缘 间隙放电 海拔修正系数
下载PDF
35kV输电线路玻璃绝缘子串中残锤的危害分析 被引量:1
10
作者 郑江 刘均华 卓少伟 《红水河》 2024年第3期118-123,共6页
针对35 kV输电线路玻璃绝缘子零值自爆后的残锤,分析残锤的外绝缘、内绝缘特性,并结合两个实例分析在大风大雨作用下35 kV输电线路玻璃绝缘子串中残锤的危害,还针对残锤的危害提出了反措。结果表明:雨水可通过残锤的外绝缘渗浸内绝缘;... 针对35 kV输电线路玻璃绝缘子零值自爆后的残锤,分析残锤的外绝缘、内绝缘特性,并结合两个实例分析在大风大雨作用下35 kV输电线路玻璃绝缘子串中残锤的危害,还针对残锤的危害提出了反措。结果表明:雨水可通过残锤的外绝缘渗浸内绝缘;运行中若未能及时发现和更换残锤,大风大雨将有可能引发存在残锤的35 kV输电线路玻璃绝缘子串发生单相接地闪络故障。其中,在残锤的内绝缘没有被雨水渗浸前,其内绝缘水平高于外绝缘水平,闪络电弧从残锤的外绝缘直接拉弧导通,将有可能导致单相接地闪络故障延时跳闸的35 kV输电线路发生烧断导线故障;在残锤的内绝缘被雨水渗浸后,其内绝缘水平低于外绝缘水平,闪络电弧从被雨水渗浸的残锤内绝缘导通,将有可能发生35 kV输电线路掉串故障。 展开更多
关键词 玻璃绝缘子 残锤 零值自爆 外绝缘 内绝缘 35 kV输电线路
下载PDF
岩棉复合保温外模板承载力及温度效应分析
11
作者 赵建军 付佳欣 李爽 《哈尔滨工业大学学报》 EI CAS CSCD 北大核心 2024年第1期130-138,共9页
为了提高建筑外围护结构施工效率及解决传统外保温系统长期存在的易脱落和易着火问题,提出了一种集保温和建筑模板于一体的岩棉复合保温外模板(RW-CIEF)体系。RW-CIEF由内到外依次为内侧加强层、岩棉保温芯材、黏结层、保温过渡层以及... 为了提高建筑外围护结构施工效率及解决传统外保温系统长期存在的易脱落和易着火问题,提出了一种集保温和建筑模板于一体的岩棉复合保温外模板(RW-CIEF)体系。RW-CIEF由内到外依次为内侧加强层、岩棉保温芯材、黏结层、保温过渡层以及外侧加强层。以哈尔滨市为例,基于全寿命周期成本(life cycle cost,C lc)确定了岩棉保温芯材的最佳厚度。采用有限元分析与理论计算相结合的方法探求了RW-CIEF在工程中的可行性,分析了RW-CIEF的抗弯性能、施工承载力及温度效应下的应力和变形,讨论了开槽形式、开槽宽度、开槽深度以及开槽间距对RW-CIEF抗弯性能的影响。结果表明:RW-CIEF的抗弯性能理论计算结果与有限元分析结果有较高的一致性;开槽处理可有效提高RW-CIEF的抗弯性能,综合抗弯性能、热工特性及加工角度,建议开槽形式选用对应开井字槽或对应开纵槽,开槽深度和宽度均为10 mm,开槽间距为150 mm;设计的RW-CIEF满足施工承载力,可保证外围护结构保温工程施工质量;由温度效应产生的最大拉应力和压应力均未超过RW-CIEF的外侧加强层承载力,反映出RW-CIEF出现夏季空鼓或冬季开裂现象的可能性极小。提出的RW-CIEF体系可为外围护结构保温工程及建筑模板工程未来研究方向提供一种新的思路和方法。 展开更多
关键词 岩棉复合保温外模板 抗弯性能 开槽处理 施工承载力 温度效应
下载PDF
预制内外复合保温模壳拼装墙体热工性能研究
12
作者 王洪镇 张笑笑 +4 位作者 杨永恒 王璟 褚文斌 高潇 李雨泽 《混凝土与水泥制品》 2024年第4期70-76,共7页
为探究预制内外复合保温模壳拼装墙体结构中的卡板连接件对墙体热工性能的影响,通过热工理论计算、试验研究、ANSYS有限元热分析模拟软件3种方法,对比分析了无连接件、不同数量连接件以及双面抹灰不同条件下墙体的传热系数。结果表明:... 为探究预制内外复合保温模壳拼装墙体结构中的卡板连接件对墙体热工性能的影响,通过热工理论计算、试验研究、ANSYS有限元热分析模拟软件3种方法,对比分析了无连接件、不同数量连接件以及双面抹灰不同条件下墙体的传热系数。结果表明:在无连接件条件下,实际墙体热工试验测试值与热工理论计算值的误差较小;连接件数量越多,热桥效应越明显,墙体的热工性能越差;采用有限元模拟软件对墙体进行热工设计结果较精确,可作为设计依据;研究结果可为模壳拼装墙体在超低能耗建筑的应用及能耗分析提供借鉴。 展开更多
关键词 内外复合保温模壳 卡板连接件 拼装墙体 热桥效应 传热系数
下载PDF
外墙保温研究现状及发展趋势
13
作者 刘国敏 陈垚 殷玥 《绿色建筑》 CAS 2024年第5期84-89,100,共7页
建筑节能需求随建筑业发展逐步增大,外墙保温是解决节能问题的方式之一。从外墙的保温方式入手,对国内外外墙保温的现状进行综述,并通过比较指出现阶段保温方式做法存在的问题。目前,众多仿生建筑以及仿生结构案例快速涌现,为外墙保温... 建筑节能需求随建筑业发展逐步增大,外墙保温是解决节能问题的方式之一。从外墙的保温方式入手,对国内外外墙保温的现状进行综述,并通过比较指出现阶段保温方式做法存在的问题。目前,众多仿生建筑以及仿生结构案例快速涌现,为外墙保温提供了思路。通过对动物翅膀表面以及皮毛等部位进行深入研究后发现,其具有的各类结构能够应用到外墙表面,极大地提高了外墙的光热转化效率,或者通过这种结构来降低自身的热传导率,减少热量的损失,保温效果也能得到相应的提高,在节省材料的同时,能够实现节能减排的效果。 展开更多
关键词 外墙保温 建筑节能 仿生
下载PDF
LNG管道冷保温外护材料CSPE施工技术研究
14
作者 付春雷 刘书法 +2 位作者 程晋宜 晏学兵 叶楠 《化工与医药工程》 CAS 2024年第5期42-46,共5页
以某大型LNG项目为例,介绍了一种新型LNG管道冷保温外护材料—CSPE(氯磺化聚乙烯)的材料特性、结构性能及防护特点,总结了CSPE外护材料施工的工艺流程和技术要点,同时对施工过程中CSPE可能产生的质量问题进行分析并提出对应解决方案,防... 以某大型LNG项目为例,介绍了一种新型LNG管道冷保温外护材料—CSPE(氯磺化聚乙烯)的材料特性、结构性能及防护特点,总结了CSPE外护材料施工的工艺流程和技术要点,同时对施工过程中CSPE可能产生的质量问题进行分析并提出对应解决方案,防止因CSPE外护层失效所带来的设备设施安全风险与隐患,为新建LNG管道同类型冷保温外护施工提供参考。 展开更多
关键词 LNG 管道 冷保温 外护 CSPE
下载PDF
城市道路交通噪声频谱及其对隔声评价中频谱修正量的影响
15
作者 蔡阳生 陈智慧 +1 位作者 AKRAM A N A 袁旻忞 《振动与冲击》 EI CSCD 北大核心 2024年第19期287-297,共11页
现行隔声评价标准中交通噪声频谱修正量参考的是20世纪80年代北欧测量得到的交通噪声数据。为了研究C_(tr)修正量是否适用于评价建筑外窗对新时代城市道路交通噪声的隔声性能,对多种城市交通道路进行噪声监测,根据测量结果提出一组新的... 现行隔声评价标准中交通噪声频谱修正量参考的是20世纪80年代北欧测量得到的交通噪声数据。为了研究C_(tr)修正量是否适用于评价建筑外窗对新时代城市道路交通噪声的隔声性能,对多种城市交通道路进行噪声监测,根据测量结果提出一组新的交通噪声频谱修正曲线C_(A),计算11种常见外窗构造在不同频率范围内的计权隔声量,并对比分析不同频谱修正量声压级频谱的差异性。结果表明:不同城市道路交通噪声频谱都具有低频声压级高、中频平稳、高频下降的相似特点;当今的城市道路交通噪声低频能量远低于C_(tr)所参考的频谱,其能量频谱分布更接近于C_(100~3150);对比分析11组外窗的交通噪声频谱修正量C_(A)与现行标准的频谱修正量的差异,C_(A)均落于C和C_(tr)参考频谱之间的范围内;C_(A)与C、C_(tr)参考频谱的相关系数R2的值均>0.9且高于C与C_(tr)的相关性,因此C_(A)对城市道路交通噪声频谱修正具有更好的适用性与代表性,研究结果可为临街住宅的隔声降噪工程提供数据参考。 展开更多
关键词 城市道路交通噪声 隔声 频谱修正量 外窗
下载PDF
超低能耗建筑外墙聚氨酯空腔发泡保温施工技术 被引量:2
16
作者 张伟 于宁 张彦彬 《建筑技术》 2024年第2期214-217,共4页
传统超低能耗建筑外墙保温基本为无机、有机板材复合外保温系统,施工过程中质量不稳定,系统主要问题包括空鼓、开裂、饰面层脱落、渗漏、细部节点出现热桥等。以在建项目工程为案例,深入介绍了超低能耗建筑外墙聚氨酯空腔发泡保温系统... 传统超低能耗建筑外墙保温基本为无机、有机板材复合外保温系统,施工过程中质量不稳定,系统主要问题包括空鼓、开裂、饰面层脱落、渗漏、细部节点出现热桥等。以在建项目工程为案例,深入介绍了超低能耗建筑外墙聚氨酯空腔发泡保温系统施工工艺及无热桥施工技术,归纳了外墙聚氨酯空腔发泡保温技术的施工应用要点及注意事项,总结了聚氨酯空腔发泡外墙保温技术优势,旨在改进超低能耗建筑外墙施工技术,在满足建筑节能要求的前提下,降低成本,加快推进超低能耗建筑高质量发展。 展开更多
关键词 超低能耗建筑 聚氨酯发泡 外墙保温
下载PDF
沿海核电厂输变电设备绝缘材料在台风产生盐害情况下绝缘降低发生闪络导致丧失厂外电有关现象的研究
17
作者 许友龙 郑超颖 +2 位作者 张慧一 郑丽馨 李洋 《核电子学与探测技术》 CAS 北大核心 2024年第2期297-302,共6页
2020年9月,韩国8台核电机组因台风“美莎克”(2020年9月3日)和“海神”(2020年9月7日)发生丧失厂外电源事件。发生此事件是由于核电厂与外部变电站及相关设施之间的输电线以及绝缘材料路出现问题。本文调查分析了丧失厂外电的原因和事... 2020年9月,韩国8台核电机组因台风“美莎克”(2020年9月3日)和“海神”(2020年9月7日)发生丧失厂外电源事件。发生此事件是由于核电厂与外部变电站及相关设施之间的输电线以及绝缘材料路出现问题。本文调查分析了丧失厂外电的原因和事故序列,判断事件主要原因为输变电设备绝缘材料在台风产生盐害情况下绝缘降低发生闪络导致丧失厂外电。同时,梳理了国内外类似盐害现象导致绝缘降低的事件,研究盐害引起绝缘降低发生的闪络现象,得出研究结论并提出合理改进建议。 展开更多
关键词 盐害 闪络 丧失厂外电 台风 气体绝缘母线
下载PDF
复合保温外墙体系施工技术研究 被引量:1
18
作者 李璐 《科学技术创新》 2024年第2期179-182,共4页
随着我国能源消耗的不断增加,工程方对居住建筑节能的要求也在不断提高。当前,我国的建筑节能设计标准已经从节能50%以上到了第一阶段节能幅度大于75%以上的要求,总之,建筑节能设计已成为行业发展的当务之急。针对外墙施工存在经济效益... 随着我国能源消耗的不断增加,工程方对居住建筑节能的要求也在不断提高。当前,我国的建筑节能设计标准已经从节能50%以上到了第一阶段节能幅度大于75%以上的要求,总之,建筑节能设计已成为行业发展的当务之急。针对外墙施工存在经济效益差的问题,开展复合保温外墙体系施工技术研究。提出一种全新的施工方案,其中包括:墙体骨架和面板安装、泡沫混凝土填充浇筑和一体化保温板复合外墙保温体系施工。通过对新施工技术的经济效益分析得出,新技术更具经济效益,每平米的造价更低。 展开更多
关键词 复合 保温 外墙 体系 施工 技术
下载PDF
民用建筑节能检测中常用外墙保温隔热材料检测方法研究 被引量:1
19
作者 刘新惠 《广东建材》 2024年第4期46-49,共4页
为解决民用建筑能耗大的问题,本文结合某工程的实际情况,详细分析了民用建筑外墙保温隔热材料节能检测原理后,针对在检测过程中存在的问题,提出了相应的解决措施,其中涵盖了优化改善检测环境、创新升级检测设备以及做好取样工作等,旨在... 为解决民用建筑能耗大的问题,本文结合某工程的实际情况,详细分析了民用建筑外墙保温隔热材料节能检测原理后,针对在检测过程中存在的问题,提出了相应的解决措施,其中涵盖了优化改善检测环境、创新升级检测设备以及做好取样工作等,旨在提升常用外墙保温隔热材料在民用建筑中的应用质量和效率,促进建筑行业的节能化发展,以期为相关人员提供参考和借鉴。 展开更多
关键词 民用建筑 节能检测 外墙保温 隔热材料
下载PDF
既有建筑外墙外保温节能改造及经济效益分析 被引量:2
20
作者 冯沐春 《山西建筑》 2024年第8期174-177,共4页
随着社会的发展,许多二十世纪八九十年代建造的房屋外墙结构保温隔热性能已经不足以满足当今需求,从而导致能耗过高、室内热环境恶化。为此,我国正在积极推进绿色发展,努力实现低碳、可持续的生产和生活方式。为节约资源能源,改善居住环... 随着社会的发展,许多二十世纪八九十年代建造的房屋外墙结构保温隔热性能已经不足以满足当今需求,从而导致能耗过高、室内热环境恶化。为此,我国正在积极推进绿色发展,努力实现低碳、可持续的生产和生活方式。为节约资源能源,改善居住环境,有必要对旧有建筑墙体进行改造。结合济南市某节能改造项目,介绍了一种新型外墙外保温工艺,并对其经济效益进行了综合研究,结果表明,该工艺节能效果好,经济效益显著。 展开更多
关键词 既有建筑 外墙外保温 节能改造 经济效益
下载PDF