The finite element model of an external thermal composite insuiation system, thin rendered expanded polystyrene ( EPS ) board, was built with ANSYS 1.0, which had two forms: one with window and one without window. ...The finite element model of an external thermal composite insuiation system, thin rendered expanded polystyrene ( EPS ) board, was built with ANSYS 1.0, which had two forms: one with window and one without window. The finite element analysis results show that the EPS board had very good insulation capacity at both high or low temperature, stress concentration was produced in the center of wall and around window, and the maximum deformation was observed at the edge of board and the minimum deformation was in the center.展开更多
Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,...Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,polystyrene granule mortar and polyurethane foam in order to study the weatherablility of external thermal insulation system(ETIS).The change rules of adhesive strength were hereby studied at different time period of atmospheric exposure tests.The experimental results show that the adhesive strength of three kinds of ETIS changes a little during high temperature-spraying water cycle,but the adhesive strength of ETIS with EPS board decreases significantly after heating-refrigeration cycle.The lowering rate of adhesive strength with painting finishes is obviously faster than that of tile finishes for ETIS of EPS board during heating-refrigeration cycle.The weatherability of ETIS with EPS board is worse than the other two,and ETIS of polystyrene granule mortar and polyurethane foam are more suitable than ETIS of EPS board in cold area.展开更多
基金The Research Fund for the Doctoral Pro-gram of Higher Education of China(No.20050487017)
文摘The finite element model of an external thermal composite insuiation system, thin rendered expanded polystyrene ( EPS ) board, was built with ANSYS 1.0, which had two forms: one with window and one without window. The finite element analysis results show that the EPS board had very good insulation capacity at both high or low temperature, stress concentration was produced in the center of wall and around window, and the maximum deformation was observed at the edge of board and the minimum deformation was in the center.
基金Funded by the Specialized Research Fund for the Doctoral Program of Higher Education of China (No. 20050487017)
文摘Atmospheric exposure tests including two experimental stages of high temperature-spraying water cycle and heating-refrigeration cycle were carried out on three currently used ETIS of expanded polystyrene(EPS) board,polystyrene granule mortar and polyurethane foam in order to study the weatherablility of external thermal insulation system(ETIS).The change rules of adhesive strength were hereby studied at different time period of atmospheric exposure tests.The experimental results show that the adhesive strength of three kinds of ETIS changes a little during high temperature-spraying water cycle,but the adhesive strength of ETIS with EPS board decreases significantly after heating-refrigeration cycle.The lowering rate of adhesive strength with painting finishes is obviously faster than that of tile finishes for ETIS of EPS board during heating-refrigeration cycle.The weatherability of ETIS with EPS board is worse than the other two,and ETIS of polystyrene granule mortar and polyurethane foam are more suitable than ETIS of EPS board in cold area.