Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on...Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on the theory of Newton-Laphson power flow method,this simulation system imitates the primary device and secondary circuit,together with the normal,the abnormal and accidents in operation.Through simulation in various situations,it validates that this design is capable of simulating the complicated faults in UHV and EHV accurately and in real time.In addition,it can analyse and dispose them efficiently.展开更多
This paper introduces the selection and scheme demonstration of higher voltage class in Northwest ChinaPower Network, and conclusions made by main research institutes and experts’ comments.[
The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly es...The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly estimate the COG of single conductors and is not applicable to large cross-section bundle conductors.In this paper,experiments are conducted to investigate the corona characteristics of a whole series of bundle conductors at different altitudes,and a prediction formula is proposed for the COG of large cross-section bundle conductors on AC transmission lines considering the altitude correction.The calculated values using the proposed prediction formula are compared with the experimental values of the COG in two cases:UHV eight-bundle conductors at an altitude of 19 m;500 kV UHV four-bundle conductors in Wuhan,Xining,Geermu,and Nachitai at four different altitudes.The results show that the use of the formula can predict the COG of bundle conductors with the radius of 1.34 cm to 1.995 cm and the number of subconductors of 4 to 12 at altitudes of 19 m to 4000 m above the mean sea level.The research findings can provide a reference for the design of EHV and UHV overhead transmission lines and even those in higher voltage levels.展开更多
基金China Postdoctoral Science Foundation(No.20080441149)Shandong Province Postdoctoral Innovation Program Foundation(No.200803036)SDUST Research Fund(No.2010KYTD101)
文摘Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on the theory of Newton-Laphson power flow method,this simulation system imitates the primary device and secondary circuit,together with the normal,the abnormal and accidents in operation.Through simulation in various situations,it validates that this design is capable of simulating the complicated faults in UHV and EHV accurately and in real time.In addition,it can analyse and dispose them efficiently.
文摘This paper introduces the selection and scheme demonstration of higher voltage class in Northwest ChinaPower Network, and conclusions made by main research institutes and experts’ comments.[
基金This work was supported by the National Natural Science Foundation of China(51577069,51277073)National Basic Research Programme of China(2011CB209401)+2 种基金the Science and Technology Project of State Grid Corporation of China(SGTYHT/15-JS-191)the Science and Technology Program of EPPEI(K201909-D)the Fundamental Research Funds for the Central Universities(2020MS092).
文摘The corona onset voltage gradient(COG)of conductors is a key parameter in the design of overhead transmission lines.The commonly used semi-empirical calculation formula proposed by Peek(1910s)at present can roughly estimate the COG of single conductors and is not applicable to large cross-section bundle conductors.In this paper,experiments are conducted to investigate the corona characteristics of a whole series of bundle conductors at different altitudes,and a prediction formula is proposed for the COG of large cross-section bundle conductors on AC transmission lines considering the altitude correction.The calculated values using the proposed prediction formula are compared with the experimental values of the COG in two cases:UHV eight-bundle conductors at an altitude of 19 m;500 kV UHV four-bundle conductors in Wuhan,Xining,Geermu,and Nachitai at four different altitudes.The results show that the use of the formula can predict the COG of bundle conductors with the radius of 1.34 cm to 1.995 cm and the number of subconductors of 4 to 12 at altitudes of 19 m to 4000 m above the mean sea level.The research findings can provide a reference for the design of EHV and UHV overhead transmission lines and even those in higher voltage levels.
文摘为保障低压配电线路检修作业安全,有必要研究低压配线在停运检修状态下的感应电压和电流。采用EMTP建模仿真,分别计算了上海地区4个超/特高压交、直流输电工程线路下方平行架设的380 V低压配线上的感应电压、电流,对影响感应的因素进行了分析,并设计研发了低压配电线路感应电压消除装置。仿真结果表明,超/特高压交、直流线路在其下方停运的380 V配线上产生较大的感应电压和电流,感应电压最高可达30~70 k V。试验结果表明,低压配线感应电压消除装置在线路停运时将其两端接地,能有效消除配电线路上的感应电压。