To better improve the electrical safety of buildings and fulfill the role of lightning protection and grounding,this article combines cases and discusses seven aspects of lightning protection devices’construction tec...To better improve the electrical safety of buildings and fulfill the role of lightning protection and grounding,this article combines cases and discusses seven aspects of lightning protection devices’construction technology.These aspects include the lightning protection classification of buildings,air terminals,down conductors,grounding devices,division of lightning protection zones,and lightning electromagnetic pulse shielding.Through the introduction of this article,readers can gain a comprehensive understanding of the application and value of lightning protection grounding construction technology in building electrical installation projects.展开更多
超高压(Extra High Voltage,EHV)输电线路多为同塔双回,引雷面积大,更易遭受到雷击,特别是对于山谷间大跨度的杆塔常发生绕击跳闸事故。据运检单位统计表明,绕击是引起线路跳闸的主要原因。因此,对输电线路雷电绕击进行分析,探讨影响同...超高压(Extra High Voltage,EHV)输电线路多为同塔双回,引雷面积大,更易遭受到雷击,特别是对于山谷间大跨度的杆塔常发生绕击跳闸事故。据运检单位统计表明,绕击是引起线路跳闸的主要原因。因此,对输电线路雷电绕击进行分析,探讨影响同塔双回输电线路防雷性能的敏感因素是十分必要的。建立500 kV输电线路的绕击模型,该模型采用电气几何模型(Electrical Geometric Model,EGM)法,通过呼高、地面坡度、保护角、导线相序排列变化所导致的雷电绕击跳闸次数变化来反映出各因素对于绕击耐雷性能的影响。展开更多
构建基于极波的特高压直流输电(ultra high voltage DC,UHVDC)线路暂态保护的启动元件、边界元件、雷击干扰识别元件和故障选极元件。线路故障后,保护安装处量测的极波首波头幅值比其对应的极线电压、线模电压和零模电压首波头幅值大,...构建基于极波的特高压直流输电(ultra high voltage DC,UHVDC)线路暂态保护的启动元件、边界元件、雷击干扰识别元件和故障选极元件。线路故障后,保护安装处量测的极波首波头幅值比其对应的极线电压、线模电压和零模电压首波头幅值大,且更为陡峭,故利用极波变化率构造启动判据;利用极波信息熵测度对故障特征进行定量描述、分析和估计来形成区内外故障的识别判据;雷击故障的极波波形远离零轴,而雷击未故障的极波围绕零轴交替变化,故利用短窗内极波采样值直接求均值来构建快速的雷电干扰识别算法;故障极极波与零轴构成的面积远大于非故障极波与零轴构成的面积,故利用正负极的极波与零轴构成的面积之比进行故障选极。时窗取为5 ms,避开控制系统响应对暂态保护的影响。PSCAD仿真结果表明,所提极波暂态量保护原理正确,算法有效。展开更多
高压直流(high voltage direct current,HVDC)输电线路两端的平波电抗器和直流滤波器构成现实的边界元件,对暂态电压高频分量呈带阻传变特性,来自直流线路区外的高频电压信号通过平波电抗器和直流滤波器后被衰减,其能量显著减小,不同频...高压直流(high voltage direct current,HVDC)输电线路两端的平波电抗器和直流滤波器构成现实的边界元件,对暂态电压高频分量呈带阻传变特性,来自直流线路区外的高频电压信号通过平波电抗器和直流滤波器后被衰减,其能量显著减小,不同频带的高频电压信号小波能量可应用小波变换求得。利用区内、外故障时于保护安装处获得的暂态电压小波能量的显著差异来构造直流输电线路区内、外故障判据;利用故障暂态电压小波变换模极大值,构造启动判据;利用正极和负极暂态电压分别与+800和-800kV的相关系数,构造雷击干扰识别判据;利用两极线极波,构造故障选极判据。给出了特高压直流(ultra high voltage direct current,UHVDC)输电线路单端电气量暂态保护方案。对该保护进行了大量仿真分析,计及了雷击干扰、边界上避雷器动作、不同过渡电阻、换相失败故障等因素的影响。仿真结果表明,该保护具有绝对选择性,能可靠有效地保护直流线路全长。展开更多
针对输电线路传统防雷装置的局限性,研制了一种新型输电线路雷击闪络限制装置,有效地整合了传统线路避雷器及并联间隙的优势。以新型110 k V输电线路雷击闪络限制器为例,设计了产品相关技术参数及安装结构,通过理论分析和仿真计算,从防...针对输电线路传统防雷装置的局限性,研制了一种新型输电线路雷击闪络限制装置,有效地整合了传统线路避雷器及并联间隙的优势。以新型110 k V输电线路雷击闪络限制器为例,设计了产品相关技术参数及安装结构,通过理论分析和仿真计算,从防雷性能、电气性能、机械性能等方面论述了研制的可行性。理论计算结果表明,该装置的电气性能良好,满足绝缘配合及爬电距离要求;机械性能可靠,抗弯、抗拉能力显著。仿真结果表明,该装置钳位效果明显,能够显著提高杆塔的反击、绕击耐雷水平,可靠保护杆塔。展开更多
文摘To better improve the electrical safety of buildings and fulfill the role of lightning protection and grounding,this article combines cases and discusses seven aspects of lightning protection devices’construction technology.These aspects include the lightning protection classification of buildings,air terminals,down conductors,grounding devices,division of lightning protection zones,and lightning electromagnetic pulse shielding.Through the introduction of this article,readers can gain a comprehensive understanding of the application and value of lightning protection grounding construction technology in building electrical installation projects.
文摘构建基于极波的特高压直流输电(ultra high voltage DC,UHVDC)线路暂态保护的启动元件、边界元件、雷击干扰识别元件和故障选极元件。线路故障后,保护安装处量测的极波首波头幅值比其对应的极线电压、线模电压和零模电压首波头幅值大,且更为陡峭,故利用极波变化率构造启动判据;利用极波信息熵测度对故障特征进行定量描述、分析和估计来形成区内外故障的识别判据;雷击故障的极波波形远离零轴,而雷击未故障的极波围绕零轴交替变化,故利用短窗内极波采样值直接求均值来构建快速的雷电干扰识别算法;故障极极波与零轴构成的面积远大于非故障极波与零轴构成的面积,故利用正负极的极波与零轴构成的面积之比进行故障选极。时窗取为5 ms,避开控制系统响应对暂态保护的影响。PSCAD仿真结果表明,所提极波暂态量保护原理正确,算法有效。
文摘高压直流(high voltage direct current,HVDC)输电线路两端的平波电抗器和直流滤波器构成现实的边界元件,对暂态电压高频分量呈带阻传变特性,来自直流线路区外的高频电压信号通过平波电抗器和直流滤波器后被衰减,其能量显著减小,不同频带的高频电压信号小波能量可应用小波变换求得。利用区内、外故障时于保护安装处获得的暂态电压小波能量的显著差异来构造直流输电线路区内、外故障判据;利用故障暂态电压小波变换模极大值,构造启动判据;利用正极和负极暂态电压分别与+800和-800kV的相关系数,构造雷击干扰识别判据;利用两极线极波,构造故障选极判据。给出了特高压直流(ultra high voltage direct current,UHVDC)输电线路单端电气量暂态保护方案。对该保护进行了大量仿真分析,计及了雷击干扰、边界上避雷器动作、不同过渡电阻、换相失败故障等因素的影响。仿真结果表明,该保护具有绝对选择性,能可靠有效地保护直流线路全长。
文摘针对输电线路传统防雷装置的局限性,研制了一种新型输电线路雷击闪络限制装置,有效地整合了传统线路避雷器及并联间隙的优势。以新型110 k V输电线路雷击闪络限制器为例,设计了产品相关技术参数及安装结构,通过理论分析和仿真计算,从防雷性能、电气性能、机械性能等方面论述了研制的可行性。理论计算结果表明,该装置的电气性能良好,满足绝缘配合及爬电距离要求;机械性能可靠,抗弯、抗拉能力显著。仿真结果表明,该装置钳位效果明显,能够显著提高杆塔的反击、绕击耐雷水平,可靠保护杆塔。