期刊文献+
共找到340篇文章
< 1 2 17 >
每页显示 20 50 100
EFFECT OF LOW-FREQUENCY ELECTROMAGNETIC FIELD ON THE AS-CASTING MICROSTRUCTURES AND MECHANICAL PROPERTIES OF HDC 2024 ALUMINUM ALLOY 被引量:4
1
作者 Q.F. Zhu Z.H. Zhao J.Z. Cui Y.B. Zuo F. Qu 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2008年第3期205-210,共6页
The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were pro... The influences of the low frequency electromagnetic field on the horizontal direct chill casting process were investigated experimentally. Ingots of 2024 aluminum alloy with a cross size of 40 mm× 200 mm were produced by the conventional horizontal chill casting process and low frequency electromagnetic horizontal chill casting processre- spectively. The as-cast structures and the mechanical property of the ingots were examined. The results showed that the low frequency electromagnetic field could sub- stantially refine the microstructures and pronouncedly reduce the macrosegregation in the horizontal direct chill casting process. Moreover, the surface quality of the ingot was prominently improved by the low frequency electromagnetic field. The fracture strength and elongation percentage of the ingot was increased with the low frequency electromagnetic field. 展开更多
关键词 Horizontal direct chill casting low frequency electromagnetic field 2024 aluminum alloy MICROSTRUCTURES MACROSEGREGATION
下载PDF
Effect of low-frequency electromagnetic field on the as-cast microstructure of a new super high strength aluminum alloy by horizontal continuous casting 被引量:8
2
作者 Yubo ZUO Jianzhong CUI +3 位作者 Yang WANG Xiaotao LIU Zhihao ZHAO Haitao Zhang 《China Foundry》 SCIE CAS 2005年第1期48-51,共4页
The super high strength aluminum alloy ingots with 100 mm in diameter were cast by the process of low-frequency electromagnetic horizontal continuous casting (LFEHC) and the effect of electromagnetic field on the as-c... The super high strength aluminum alloy ingots with 100 mm in diameter were cast by the process of low-frequency electromagnetic horizontal continuous casting (LFEHC) and the effect of electromagnetic field on the as-cast microstructure was studied. Results show that microstructure of the sample prepared by the LFEHC process was greatly refined. Microstructures at the border and the center of the ingots were fine, uniform and rosette-shaped. Electromagnetic frequency plays a key role in microstructure refining. Fine and uniform microstructures can be obtained with optimal electromagnetic frequency. In this experiment, under a frequency of 30 Hz the microstructure was the finest and the most uniform. 展开更多
关键词 low-frequency electromagnetic field HORIZONTAL continuous CASTING microstructure AL-ZN-MG-CU alloy
下载PDF
Low-frequency pulsed electromagnetic field pretreated bone marrow-derived mesenchymal stem cells promote the regeneration of crush-injured rat mental nerve 被引量:12
3
作者 NaRi Seo Sung-Ho Lee +5 位作者 Kyung Won Ju JaeMan Woo BongJu Kim SoungMin Kim Jeong Won Jahng Jong-Ho Lee 《Neural Regeneration Research》 SCIE CAS CSCD 2018年第1期145-153,共9页
Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal d... Bone marrow-derived mesenchymal stem cells (BMSCs) have been shown to promote the regeneration of injured peripheral nerves. Pulsed electromagnetic field (PEMF) reportedly promotes the proliferation and neuronal differentiation of BMSCs. Low-frequency PEMF can induce the neuronal differentiation of BMSCs in the absence of nerve growth factors. This study was designed to investigate the effects of low-frequency PEMF pretreatment on the proliferation and function of BMSCs and the effects of low-frequency PEMF pre-treated BMSCs on the regeneration of injured peripheral nerve using in vitro and in vivo experiments.In in vitro experiments, quantitative DNA analysis was performed to determine the proliferation of BMSCs, and reverse transcription-polymerase chain reaction was performed to detect S100 (Schwann cell marker), glial fibrillary acidic protein (astrocyte marker), and brain-derived neurotrophic factor and nerve growth factor (neurotrophic factors) mRNA expression. In the in vivo experiments, rat models of crush-injured mental nerve established using clamp method were randomly injected with low-frequency PEMF pretreated BMSCs, unpretreated BMSCs or PBS at the injury site (1 × 106 cells). DiI-labeled BMSCs injected at the injury site were counted under the fluorescence microscope to determine cell survival. One or two weeks after cell injection, functional recovery of the injured nerve was assessed using the sensory test with von Frey filaments. Two weeks after cell injection, axonal regeneration was evaluated using histomorphometric analysis and retrograde labeling of trigeminal ganglion neurons. In vitro experiment results revealed that low-frequency PEMF pretreated BMSCs proliferated faster and had greater mRNA expression of growth factors than unpretreated BMSCs. In vivo experiment results revealed that compared with injection of unpretreated BMSCs, injection of low-frequency PEMF pretreated BMSCs led to higher myelinated axon count and axon density and more DiI-labeled neurons in the trigeminal ganglia, contributing to rapider functional recovery of injured mental nerve. These findings suggest that low-frequency PEMF pretreatment is a promising approach to enhance the efficacy of cell therapy for peripheral nerve injury repair. 展开更多
关键词 nerve regeneration mesenchymal stem cells low-frequency pulsed electromagnetic field peripheral nerve injury crush-injured mental nerve
下载PDF
Effect of low frequency electromagnetic field on microstructures and macrosegregation of horizontal direct chill casting aluminum alloy 被引量:5
4
作者 赵志浩 崔建忠 +2 位作者 董杰 张海涛 张北江 《中国有色金属学会会刊:英文版》 CSCD 2004年第6期1095-1099,共5页
The influences of low frequency electromagnetic field on cast surface, microstructures and macrosegregation in horizontal direct chill(HDC) casting process were investigated experimentally. The cast surfaces, microstr... The influences of low frequency electromagnetic field on cast surface, microstructures and macrosegregation in horizontal direct chill(HDC) casting process were investigated experimentally. The cast surfaces, microstructures and macrosegregation of the ingots manufactured by conventional HDC and low frequency electromagnetic HDC casting were compared. The results show that low frequency electromagnetic field significantly improves the surface quality, refines the microstructures and reduces macrosegregation. Further more, increasing electromagnetic intensity or decreasing frequency is beneficial to the improvement. In the range of ampere-turns and frequency employed in the experiments, the optimum ampere-turns is found to be 10 000 A·turn and the frequency to be 30 Hz. 展开更多
关键词 微观结构 宏观偏析 电磁场 水平冷硬铸造
下载PDF
Temperature field in the hot-top during casting a new super-high strength Al-Zn-Mg-Cu alloy by low frequency electromagnetic process
5
作者 Yubo ZUO Jianzhong CUI +3 位作者 Feiyue QUAN Ke QIN Zhihao ZHAO Haitao Zhang 《China Foundry》 SCIE CAS 2005年第3期176-179,共4页
The billets of a new super-high strength Al-Zn-Mg-Cu alloy in 200mm diameter were produced by the processesof low frequency electromagnetic casting (LFEC) and conventional direct chill (DC) casting, respectively. The ... The billets of a new super-high strength Al-Zn-Mg-Cu alloy in 200mm diameter were produced by the processesof low frequency electromagnetic casting (LFEC) and conventional direct chill (DC) casting, respectively. The effects of lowfrequency electromagnetic field on temperature field of the melt in the hot-top were investigated by temperaturemeasurement method. Temperature curves were measured from the surface to the center of the billets by locating type Kthermocouples into the casting during the processes. The results show that during LFEC process the temperature field inthe melt applying the hot-top is very uniform, which is helpful to reduce the difference of thermal gradients between thesurface and the center, and then to reduce the thermal stress and to eliminate casting crack. 展开更多
关键词 AL-ZN-MG-CU alloy low frequency electromagnetic field DC CASTING TEMPERATURE measurement TEMPERATURE field
下载PDF
Effect of Low Frequency Electromagnetic Field on Macrosegregation of Horizontal Direct Chill Casting Aluminum Alloys
6
作者 Zhihao ZHAO, Jianzhong GUI, Jie DONG and Beijiang ZHANGThe Key Laboratory of Electromagnetic Processing of Materials, Ministry of Education, P.O. Box 314, Northeastern University, Shenyang 110004, ChinaPh.D. candidate, 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2005年第1期75-78,共4页
The horizontal direct chill (HDC) casting process is a well-established production route for aluminum alloy ingot but the ingot may suffer from macrosegregation sometimes. In order to control the defect, a low frequen... The horizontal direct chill (HDC) casting process is a well-established production route for aluminum alloy ingot but the ingot may suffer from macrosegregation sometimes. In order to control the defect, a low frequency electromagnetic field has been applied in HDC casting process and the relevant influence has been studied. The results show that application of low frequency electromagnetic field can reduce macrosegregation in HDC casting process; and two main parameters of electromagnetic field density and frequency, have great influences on the solution distribution along the diameter of ingot. Moreover, the mechanisms of reduction of macrosegregation by electromagnetic field have been discussed. 展开更多
关键词 low frequency electromagnetic field Horizontal direct chill casting MACROSEGREGATION Aluminum alloy
下载PDF
EXTREMELY LOW FREQUENCY MAGNETIC FIELD SUSCEPTIBILITY OF VISUAL DISPLAY UNITS
7
作者 傅正财 杜亚平 J.Burnett 《Journal of Shanghai Jiaotong university(Science)》 EI 2001年第2期201-205,共5页
Extremely low frequency (ELF) magnetic field susceptibility is an index of visual display unit (VDU) quality and performance. This paper provided field measured data on the susceptibility for a large variety of VDUs. ... Extremely low frequency (ELF) magnetic field susceptibility is an index of visual display unit (VDU) quality and performance. This paper provided field measured data on the susceptibility for a large variety of VDUs. A test rig was built to study the susceptibility of VDUs to magnetic fields at fundamental and third harmonic frequencies. It was found that the susceptibility level is largely dependent on refresh rate of the VDU and the orientation of the external ELF field. It was also found that the VDU susceptibility is significantly increased in the presence of harmonic frequency magnetic fields. About 30% of the tested samples have susceptibility levels higher than that stated in IEC 1000-4-8 standard. 展开更多
关键词 visual display unit extremely low frequency magnetic field electromagnetic compatibility susceptibility test
下载PDF
Production of super-high strength aluminum alloy billets by low frequency electromagnetic casting 被引量:6
8
作者 张海涛 崔建忠 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第10期2134-2139,共6页
The effects of low frequency electromagnetic field on the macro-physical fields in the semi-continuous casting process of aluminum alloys and the microstructure and crack in the billets were studied and analyzed by th... The effects of low frequency electromagnetic field on the macro-physical fields in the semi-continuous casting process of aluminum alloys and the microstructure and crack in the billets were studied and analyzed by the numerical and experimental methods.Comparison of the results for the macro-physical fields in the low frequency electromagnetic casting(LFEC) process with the conventional DC casting process indicates the following characters due to the application of electromagnetic field:an entirely changed direction and remarkably increased velocity of melt flow;a uniform distribution and a decreased gradient of temperature;elevated isothermal lines;a reduced sump depth;decreased stress and plastic deformation.Further,the microstructure of the billets is refined remarkably and the crack in the billets is eliminated in LFEC process because of modification of the macro-physical fields induced by the application of low frequency electromagnetic field. 展开更多
关键词 super-high strength aluminum alloy low frequency electromagnetic casting DC casting macro-physical field CRACK MICROSTRUCTURE
下载PDF
Efects of low frequency electromagnetic ield on surface quality, microstructure and hot-tearing tendency of semi-continuous casting ZK60 magnesium alloy billets 被引量:3
9
作者 Zhang Zhiqiang Le Qichi +1 位作者 Bao Lei Cui Jianzhong 《China Foundry》 SCIE CAS 2013年第6期351-354,共4页
The low frequency electromagnetic field was applied during direct chill(DC) semi-continuous casting of the ZK60 magnesium alloy billets. Effects of low frequency electromagnetic field on surface quality, microstructur... The low frequency electromagnetic field was applied during direct chill(DC) semi-continuous casting of the ZK60 magnesium alloy billets. Effects of low frequency electromagnetic field on surface quality, microstructure and hot-tearing tendency of Φ500 mm ZK60 magnesium alloy billets were investigated. The results showed that with the application of the low frequency electromagnetic field, the surface quality of the ZK60 magnesium alloy billets is markedly improved and the depth of cold fold is decreased. The microstructure of the billets is also significantly refined. Besides, the distribution of the grain size is relatively uniform from the billet surface towards its center, where the average grain size is 42 μm at surface and 50 μm at center. It also shows that the hot-tearing tendency of DC semi-continuous casting ZK60 magnesium alloy billets is significantly reduced under low frequency electromagnetic field. 展开更多
关键词 ZK60 magnesium alloy billets direct chill casting low frequency electromagnetic field REFINEMENT
下载PDF
Analysis and Simulation of the Influence of Electromagnetic Fields on Living Beings near HV Power Lines Using the FDTD Method
10
作者 Anthony Bassesuka Sandoka Nzao 《Open Journal of Applied Sciences》 2023年第12期2343-2359,共17页
Recent decades have seen rapid advances in the field of electrical engineering, such that our environment has become a sea of electrical and magnetic signals, raising questions about the possible effects of low-freque... Recent decades have seen rapid advances in the field of electrical engineering, such that our environment has become a sea of electrical and magnetic signals, raising questions about the possible effects of low-frequency electromagnetic fields on the environment and which are capable of modifying and destroying our ecosystem. Particular interest was given in this article due to a massive influx of population living near high voltage lines. The analysis and simulation of the influence of low frequency electromagnetic fields on living beings in the vicinity of high voltage sources 132 kV and 220 kV in urban areas in DR Congo is the subject of our research with a view to estimating the level of exposure of humans to low frequency electromagnetic fields. To carry out our research, we used the classic method of analyzing the field produced near a high voltage line based on Maxwell’s image theory, the Maxwell-Gauss theorem and Maxwell-Ampère theorem to model and quantify low-frequency electromagnetic fields in the vicinity of high-voltage lines. The 2D FDTD numerical formulation was developed from telegraphers’ equations and allowed us to obtain models of current and voltage induced by electromagnetic fields on living beings below and near HV lines. The different simulations carried out on the proposed models illustrate the effects of the electrical and geometric parameters of the pylons on the distribution of the electromagnetic field in the vicinity of the HV lines. The results obtained were compared to the safety limits recommended by the standards. 展开更多
关键词 low frequency electromagnetic field Modeling field and Health Maxwell’s Equations FDTD Method electromagnetic Compatibility High Voltage Line
下载PDF
Effects of low-frequency magnetic field on grain boundary segregation in horizontal direct chill casting of 2024 aluminum alloy
11
作者 Zhihao ZHAO Jianzhong CUI +2 位作者 Jie Dong Haitao Zhang Beijiang ZHANG 《China Foundry》 SCIE CAS 2005年第1期44-47,共4页
Effects of low frequency electromagnetic field on grain boundary segregation in horizontal direct chill (HDC) casting process was investigated experimentally. The grain boundary segregation and microstructures of the ... Effects of low frequency electromagnetic field on grain boundary segregation in horizontal direct chill (HDC) casting process was investigated experimentally. The grain boundary segregation and microstructures of the ingots, which manufactured by conventional HDC casting and low frequency electromagnetic HDC casting were compared. Results show that low frequency electromagnetic field significantly refines the microstructures and reduces grain boundary segregation. Decreasing electromagnetic frequency or increasing electromagnetic intensity has great effects in reducing grain boundary segregation. Meanwhile, the governing mechanisms were discussed. 展开更多
关键词 low frequency electromagnetic field GRAIN boundary SEGREGATION HORIZONTAL direct CHILL CASTING
下载PDF
Direct-chilling casting of Mg alloy under electromagnetic and ultrasonic combined field 被引量:2
12
作者 崔建忠 张志强 乐启炽 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2010年第B07期297-305,共9页
The effects of low frequency electromagnetic (LFEC) field and ultrasonic (US) field on the microstructures, macrosegregation of alloying elements and the mechanical properties of DC cast AZ80 alloy were studied. The r... The effects of low frequency electromagnetic (LFEC) field and ultrasonic (US) field on the microstructures, macrosegregation of alloying elements and the mechanical properties of DC cast AZ80 alloy were studied. The results show that both LFEC and US fields can refine the grains of the billets, which results in the increase in mechanical properties and uniformity of alloying element distribution. The effective refinement takes place on the edge of ingots when LFEC field is applied, while in the center of billets when field US is adopted. Combined the characteristics of LFEC and US fields, a new process for direct-chilling (DC) casting of Mg-electromagnetic-ultrasonic (ECUS) casting is developed, by which the grains are refined significantly and are more uniform in the whole ingots, and the mechanical properties of the ingots are improved. 展开更多
关键词 low frequency electromagnetic field ultrasonic field Mg alloy DC casting
下载PDF
Association between Childhood Leukaemia and Exposure to Power-frequency Magnetic Fields in Middle Europe 被引量:1
13
作者 Vitezslav JIRIK Ludek PEKAREK +1 位作者 Vladimir JANOUT Hana TOMASKOVA 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2012年第5期597-601,共5页
Abstract Objective Higher levels of exposure to extremely low-frequency magnetic fields (ELF-MF) are associated with a slightly increased risk of childhood leukaemia. Compared with more-developed Western countries, ... Abstract Objective Higher levels of exposure to extremely low-frequency magnetic fields (ELF-MF) are associated with a slightly increased risk of childhood leukaemia. Compared with more-developed Western countries, higher exposure levels are evident in the Czech Republic, probably because of the different types of housing. In light of this, we aimed to examine the association between ELF-MF exposure and childhood leukaemia in the Czech Republic. Methods We conducted a paired case-control study. The cases (children with leukaemia) were age- sex- and permanent residence-matched to controls (children without leukaemia). Although this limited potential bias and confounding, it also limited our number of participants. Results The matched analyses included 79 case-control pairs. No significant association between ELF-MF exposure and childhood leukaemia was observed for exposures over 0.2 μT (odds ratio [0R]=0.93, confidence interval [Cl]=0.45-1.93), 0.3 μT (0R=0.77, Cl=0.34-1.75), or 0.4 μT (OR=0.9, Cl=0.37-2.22). Conclusion Despite higher levels of exposure in Middle and Eastern Europe, no indication of an association between ELF-MF exposure and childhood leukaemia was determined. This in contrast to the findings of previous studies conducted in different countries. 展开更多
关键词 Childhood leukaemia Power-frequency magnetic field exposure extremely low-frequencymagnetic field Housing types
下载PDF
Effects of Different Electromagnetic Fields on Circadian Rhythms of Some Haematochemical Parameters in Rats
14
作者 LAURA CONTALBRIGO CALOGERO STELLETTA +4 位作者 LAURA FALCIONI STEFANIA CASELLA GIUSEPPE PICCIONE MORANDO SOFFRITTI AND MASSIMO MORGANTE 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2009年第4期348-353,共6页
Objective To investigate the effects of different electromagnetic fields on some haematochemical parameters of circadian rhythms in Sprague-Dawley rats. Methods The study was carried out in 18 male and 18 female rats ... Objective To investigate the effects of different electromagnetic fields on some haematochemical parameters of circadian rhythms in Sprague-Dawley rats. Methods The study was carried out in 18 male and 18 female rats in good health conditions exposed to 50 Hz magnetic sinusoid fields at the intensity of 1000 μT, 100 μT, and 0 μT (control group) respectively, and in 18 male and 18 female rats in good health conditions exposed to 1.8 GHz electromagnetic fields at the intensity of 50 V/m, 25 V/m and 0 V/m (control group), respectively. Following haematochemical parameters for glucose, triglycerides, and total cholesterol were measured. Results Different effects of electromagnetic fields on circadian rhythms of both male and female rats were observed. Different changes occurred in some haematochemical parameters for glucose, triglycerides, and total cholesterol (P〈0.05). Conclusion Exposure to different electromagnetic fields is responsible for the variations of some haematochemical parameters in rats. 展开更多
关键词 extremely low frequency electromagnetic fields (50 Hz) Radiofrequency electromagnetic fields (1.8 GHz) Haematochemical parameters Circadian rhythm Sprague-Dawley rat
下载PDF
Coupled Modeling of Electromagnetic Fleld,Fluid Flow,Heat Transfer and Solidification During Conventional DC Casting and Low Ftequency Electrmagnetic Casting of 7xxx Aluminum Alloys
15
作者 Nagaum Hiromi 《特种铸造及有色合金》 CAS CSCD 北大核心 2008年第S1期485-490,共6页
A comprehensive mathematical model has been developed to describe the interaction of the multiple physics fields during the conventional DC casting and LFEC (low frequency electromagnetic casting) process. The model i... A comprehensive mathematical model has been developed to describe the interaction of the multiple physics fields during the conventional DC casting and LFEC (low frequency electromagnetic casting) process. The model is based on a combination of the commercial finite element package ANSYS and the commercial finite volume package FLUENT, with the former for the calculation of the electromagnetic field and the latter for the calculation of the magnetic driven fluid flow, heat transfer and solidification. Moreover, the model has been verified against the temperature measurements obtained from two 7XXX aluminum alloy billets of 200mm diameter, cast during the conventional DC casting and the LFEC casting processes. In addition, a measurement of the sump shape of the billets were carried out by using addition melting metal of Al-30%Cu alloy into the billets during casting process. There was a good agreement between the calculated results and the measured results. Further, comparison of the calculated results during the LFEC process with that during the conventional DC casting process indicated that velocity patterns, temperature profiles and the sump depth are strongly modified by the application of a low frequency electromagnetic field during the DC casting. 展开更多
关键词 low frequency electromagnetic casting DC casting coupled modeling temperature field fluid flow solidification.
下载PDF
Effects of electromagnetic field intensity on as-cast microstructures and mechanical properties of Al-Zn-Mg-Cu-Zr alloy
16
作者 左玉波 赵志浩 +1 位作者 王启伟 崔建忠 《中国有色金属学会会刊:英文版》 CSCD 2006年第A03期1397-1401,共5页
Al-Zn-Mg-Cu-Zr ingots with diameter of 200 mm were made by low frequency electromagnetic casting (LFEC) and conventional direct chill (DC) casting process. The results show that under the low frequency electromagnetic... Al-Zn-Mg-Cu-Zr ingots with diameter of 200 mm were made by low frequency electromagnetic casting (LFEC) and conventional direct chill (DC) casting process. The results show that under the low frequency electromagnetic field (25 Hz, 32 mT) the microstructures of LFEC ingot from the border to the center on the cross section are all equiaxed grains, and the grains are much finer and more uniform than that of DC ingot. The magnetic flux density plays an important role in the microstructure formation of LFEC ingots. With increasing the magnetic flux density from 0 mT to 32 mT, grains become finer (from about 120 urn to 30 urn) and more uniform. While, with increasing the magnetic flux density from 32 mT to 46 mT, the grains change much slowly. In the range of experimental parameters, the optimum magnetic flux density for LFEC process is found to be 32 mT. 展开更多
关键词 电磁场 合金 强度 有色金属
下载PDF
极低频电流场透地通信路径损耗建模与分析 被引量:1
17
作者 徐湛 温晓雯 张淦 《电讯技术》 北大核心 2024年第3期376-381,共6页
针对水平方向地电极电流场无线强穿透信息传输需求,研究了基于极低频水平双电极电流场信道传输特性。考虑到电极半径、电极入土深度、电极间距、发射信号频率和信号传输距离等参数对透地(Through-The-Earth,TTE)通信传输性能的影响,建... 针对水平方向地电极电流场无线强穿透信息传输需求,研究了基于极低频水平双电极电流场信道传输特性。考虑到电极半径、电极入土深度、电极间距、发射信号频率和信号传输距离等参数对透地(Through-The-Earth,TTE)通信传输性能的影响,建立了地电极电流场TTE通信路径损耗模型,分析了各参数对路径损耗的影响,确定了信号传输最佳工作参数。根据选定参数搭建了极低频电流场TTE通信系统,在200 m和400 m通信距离下测试了3~10 Hz信号的路径损耗,通过试验数据与仿真结果对比分析验证了模型的准确性。 展开更多
关键词 隧道救援 透地通信 地电极电流场 极低频 路径损耗模型
下载PDF
地中电偶极源极低频电磁场的分布与传播特征 被引量:2
18
作者 王桥 唐新功 胡文宝 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2024年第4期1527-1545,共19页
利用层状大地中偶极源响应的正演算法,计算地中电偶极源激发的极低频地震电磁场并分析其在地球环境下的传播特征.设计了多个水平层状地球模型,分别模拟和展示了深埋地中的电偶极源的响应和空间分布特征.重点分析了含地壳波导+LAI波导模... 利用层状大地中偶极源响应的正演算法,计算地中电偶极源激发的极低频地震电磁场并分析其在地球环境下的传播特征.设计了多个水平层状地球模型,分别模拟和展示了深埋地中的电偶极源的响应和空间分布特征.重点分析了含地壳波导+LAI波导模型的高阻大地中,倾斜电偶极源激励响应随观测点的偏移距和垂直位置、激励源深度、地壳波导结构和参数变化时各场量响应的幅频特征.研究表明,用倾斜电偶极源模拟和分析高阻大地中孕震电磁辐射的响应及在大地电磁系统中的传播特性是可行的;模拟的高阻大地中的电磁辐射在地壳波导和LAI波导中均表现有慢衰减或幅值增强特性,但两个波导效应具有不同的频率选择性;高阻大地中的电磁辐射在波导的高阻介质中具有幅值强、衰减慢的特点.建议在高阻地层出露的地表、井中或海底的高阻岩层中以及大气层中布设测站. 展开更多
关键词 层状模型 地中电偶极源 极低频电磁场传播特征 岩石圈波导 LAI波导
下载PDF
极低频数据中的Pc1地磁脉动自动识别
19
作者 王锋 袁静 +6 位作者 韩冰 罗浩 刘庆杰 丰继林 刘海军 韩莹 汤吉 《地球物理学报》 SCIE EI CAS CSCD 北大核心 2024年第10期3655-3669,共15页
极低频电磁台网成功观测到大量的Pc1地磁脉动事件,研究极低频Pc1地磁脉动的自动识别方法对于全面分析地球空间电磁物理环境具有重要意义.本文采用了YOLOv8目标检测网络、ResNet残差网络和定向特征增强技术,提出了一种基于计算机视觉的Pc... 极低频电磁台网成功观测到大量的Pc1地磁脉动事件,研究极低频Pc1地磁脉动的自动识别方法对于全面分析地球空间电磁物理环境具有重要意义.本文采用了YOLOv8目标检测网络、ResNet残差网络和定向特征增强技术,提出了一种基于计算机视觉的Pc1地磁脉动自动识别模型(Automatic Detection Model for Pc1 Geomagnetic Pulsation,简称ADM-Pc1).以大连台站和丽江台站的极低频观测数据为例,利用2015—2016年的数据作为训练集进行模型的监督学习,并使用2017—2022年的数据作为测试集对模型性能进行评估.实验结果显示,ADM-Pc1模型的F1-Score值达到了95%,错分率仅为0.9%,虚警率仅为5.8%,漏检率仅为9%,处理1天数据平均耗时是2.72 s,显著优于现有的最优识别模型.这表明,ADM-Pc1模型在识别效果和计算速度方面均能更好地满足实际工程需求. 展开更多
关键词 Pc1地磁脉动 计算机视觉 自动识别 极低频电磁台网
下载PDF
基于里德伯原子天线的低频电场波形测量
20
作者 张学超 乔佳慧 +6 位作者 刘瑶 苏楠 刘智慧 蔡婷 何军 赵延霆 王军民 《物理学报》 SCIE EI CAS CSCD 北大核心 2024年第7期82-89,共8页
里德伯原子的高极化率可以实现电磁场的多维度参数测量.本文利用室温里德伯原子构建原子天线,基于原子天线将低频电场幅度信息转化为强度信息,从而实现低频电场的参数测量.实验采用双光子激发制备铯原子里德伯态,通过阶梯型电磁感应透明... 里德伯原子的高极化率可以实现电磁场的多维度参数测量.本文利用室温里德伯原子构建原子天线,基于原子天线将低频电场幅度信息转化为强度信息,从而实现低频电场的参数测量.实验采用双光子激发制备铯原子里德伯态,通过阶梯型电磁感应透明(electromagnetically induced transparency,EIT)光谱实现里德伯原子量子态的检测,基于内置电极技术在室温原子气室导入k Hz频段低频电场.电场中里德伯原子的Stark频移会在EIT过程导致双光子失谐,从而引起EIT光谱频移和强度变化.在弱电场条件下,EIT光谱频移可以忽略,EIT透射强度与输入低频电场强度近似为线性关系,基于该效应可以实现低频电场的波形、幅度、频率等参数测量. 展开更多
关键词 里德伯原子 电磁感应透明光谱 低频电场 波形
下载PDF
上一页 1 2 17 下一页 到第
使用帮助 返回顶部