In this paper, a new partial transmit sequence(PTS)scheme with low computational complexity is proposed for the problems of high computational complexity in the conventional PTS method. By analyzing the relationship...In this paper, a new partial transmit sequence(PTS)scheme with low computational complexity is proposed for the problems of high computational complexity in the conventional PTS method. By analyzing the relationship of candidate sequences in the PTS method under the interleaved partition method, it has been discovered that some candidate sequences generated by phase factor sequences have the same peak average power ratio(PAPR). Hence, phase factor sequences can be optimized to reduce their searching times. Then, the computational process of generating candidate sequences can be simplified by improving the utilization of data and minimizing the calculations of complex multiplication. The performance analysis shows that, compared with the conventional PTS scheme, the proposed approach significantly decreases the computational complexity and has no loss of PAPR performance.展开更多
Virtual source(VS)imaging has been proposed to improve image resolution in medical ultrasound imaging.However,VS obtains a limited contrast due to the non-adaptive delay-and-sum(DAS)beamforming.To improve the image co...Virtual source(VS)imaging has been proposed to improve image resolution in medical ultrasound imaging.However,VS obtains a limited contrast due to the non-adaptive delay-and-sum(DAS)beamforming.To improve the image contrast and provide an enhanced resolution,adaptive weighting algorithms were applied in VS imaging.In this paper,we proposed an adjustable generalized coherence factor(aGCF)for the synthetic aperture sequential beamforming(SASB)ofVS imaging to improve image quality.The value of aGCF is adjusted by a sequence intensity factor(SIF)that is defined as the ratio between the effective low resolution scan lines(LRLs)intensity and total LRLs strength.The aGCF-weighted VS(aGCF-VS)images were compared with standard VS images and GCF-weighted VS(GCF-VS)images.Simulation and experimental results demonstrated that the contrast ratio(CR)and contrastto-noise ratio(CNR)of aGCF-VS are greatly improved,compared with standard VS imaging.And in comparison with GCF-VS,aGCF-VS can obtain better CNR and speckle signal-to-noise ratio(sSNR)whilemaintaining similar CR.Therefore,aGCF is suitable for VS imaging to improve contrast and preserve speckle pattern.展开更多
基金supported by the National Natural Science Foundation of China(6167309361370152)the Science and Technology Project of Shenyang(F16-205-1-01)
文摘In this paper, a new partial transmit sequence(PTS)scheme with low computational complexity is proposed for the problems of high computational complexity in the conventional PTS method. By analyzing the relationship of candidate sequences in the PTS method under the interleaved partition method, it has been discovered that some candidate sequences generated by phase factor sequences have the same peak average power ratio(PAPR). Hence, phase factor sequences can be optimized to reduce their searching times. Then, the computational process of generating candidate sequences can be simplified by improving the utilization of data and minimizing the calculations of complex multiplication. The performance analysis shows that, compared with the conventional PTS scheme, the proposed approach significantly decreases the computational complexity and has no loss of PAPR performance.
基金The National Natural Science Foundation of China(Grant No.62071165)the Fundamental Research Funds for the Central Universities of China(Grant No.JZ2021HGTB0074)the China Postdoctoral Science Foundation(Grant No.2021M690853).
文摘Virtual source(VS)imaging has been proposed to improve image resolution in medical ultrasound imaging.However,VS obtains a limited contrast due to the non-adaptive delay-and-sum(DAS)beamforming.To improve the image contrast and provide an enhanced resolution,adaptive weighting algorithms were applied in VS imaging.In this paper,we proposed an adjustable generalized coherence factor(aGCF)for the synthetic aperture sequential beamforming(SASB)ofVS imaging to improve image quality.The value of aGCF is adjusted by a sequence intensity factor(SIF)that is defined as the ratio between the effective low resolution scan lines(LRLs)intensity and total LRLs strength.The aGCF-weighted VS(aGCF-VS)images were compared with standard VS images and GCF-weighted VS(GCF-VS)images.Simulation and experimental results demonstrated that the contrast ratio(CR)and contrastto-noise ratio(CNR)of aGCF-VS are greatly improved,compared with standard VS imaging.And in comparison with GCF-VS,aGCF-VS can obtain better CNR and speckle signal-to-noise ratio(sSNR)whilemaintaining similar CR.Therefore,aGCF is suitable for VS imaging to improve contrast and preserve speckle pattern.