In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ...In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.展开更多
In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds ...In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds of setups which are able to transform non-visible into visible light imaging,wherein their computing process is replaced by a camera integration mode.The image captured by the camera has a low contrast,so here we present an algorithm that can realize a high quality image in near-infrared to visible cross-waveband imaging.The scheme is verified both by simulation and in actual experiments.The setups demonstrate the great potential for single-pixel imaging and high-speed cross-waveband imaging for future practical applications.展开更多
Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unc...Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unclear.In this paper,the optical imaging pattern of ISWs in sunglint under different zenith angles of the light source is investigated by collecting optical images of ISWs through physical simulation.The experiment involves setting 10 zenith angles of the light source,which are divided into area a the optical images of ISWs in the three areas show dark-bright mode,single bright band,and bright-dark mode,which are consistent with those observed by optical remote sensing.In addition,this study analyzed the percentage of the dark and bright areas of the bands and the change in the relative gray difference and found changes in both areas under different zenith angles of the light source.The MODIS and ASAR images display a similar brightness-darkness distance of the same ISWs.Therefore,the relationship between the brightness-darkness distance and the characteristic half-width of ISWs is determined in accordance with the eKdV theory and the imaging mechanism of ISWs of the SAR image.Overall,the relationship between them in the experiment is almost consistent with the theoretical result.展开更多
Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible...Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible to probe the complexity of 3D cell cultures but are limited by the inherent opaqueness.While tissue optical clearing methods have emerged as powerful tools for investigating whole-mount tissues in 3D,they often have limitations,such as being too harsh for fragile 3D cell cultures,requiring complex handling protocols,or inducing tissue deformation with shrinkage or expansion.To address this issue,we proposed a modified optical clearing method for 3D cell cultures,called MACS-W,which is simple,highly efficient,and morphology-preserving.In our evaluation of MACS-W,we found that it exhibits excellent clearing capability in just 10 min,with minimal deformation,and helps drug evaluation on tumor spheroids.In summary,MACS-W is a fast,minimally-deformative and fluorescence compatible clearing method that has the potential to be widely used in the studies of 3D cell cultures.展开更多
To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these me...To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.展开更多
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ...Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.展开更多
Mangroves are indispensable to coastlines,maintaining biodiversity,and mitigating climate change.Therefore,improving the accuracy of mangrove information identification is crucial for their ecological protection.Aimin...Mangroves are indispensable to coastlines,maintaining biodiversity,and mitigating climate change.Therefore,improving the accuracy of mangrove information identification is crucial for their ecological protection.Aiming at the limited morphological information of synthetic aperture radar(SAR)images,which is greatly interfered by noise,and the susceptibility of optical images to weather and lighting conditions,this paper proposes a pixel-level weighted fusion method for SAR and optical images.Image fusion enhanced the target features and made mangrove monitoring more comprehensive and accurate.To address the problem of high similarity between mangrove forests and other forests,this paper is based on the U-Net convolutional neural network,and an attention mechanism is added in the feature extraction stage to make the model pay more attention to the mangrove vegetation area in the image.In order to accelerate the convergence and normalize the input,batch normalization(BN)layer and Dropout layer are added after each convolutional layer.Since mangroves are a minority class in the image,an improved cross-entropy loss function is introduced in this paper to improve the model’s ability to recognize mangroves.The AttU-Net model for mangrove recognition in high similarity environments is thus constructed based on the fused images.Through comparison experiments,the overall accuracy of the improved U-Net model trained from the fused images to recognize the predicted regions is significantly improved.Based on the fused images,the recognition results of the AttU-Net model proposed in this paper are compared with its benchmark model,U-Net,and the Dense-Net,Res-Net,and Seg-Net methods.The AttU-Net model captured mangroves’complex structures and textural features in images more effectively.The average OA,F1-score,and Kappa coefficient in the four tested regions were 94.406%,90.006%,and 84.045%,which were significantly higher than several other methods.This method can provide some technical support for the monitoring and protection of mangrove ecosystems.展开更多
Objective This study aimed to develop and test a model for predicting dysthyroid optic neuropathy(DON)based on clinical factors and imaging markers of the optic nerve and cerebrospinal fluid(CSF)in the optic nerve she...Objective This study aimed to develop and test a model for predicting dysthyroid optic neuropathy(DON)based on clinical factors and imaging markers of the optic nerve and cerebrospinal fluid(CSF)in the optic nerve sheath.Methods This retrospective study included patients with thyroid-associated ophthalmopathy(TAO)without DON and patients with TAO accompanied by DON at our hospital.The imaging markers of the optic nerve and CSF in the optic nerve sheath were measured on the water-fat images of each patient and,together with clinical factors,were screened by Least absolute shrinkage and selection operator.Subsequently,we constructed a prediction model using multivariate logistic regression.The accuracy of the model was verified using receiver operating characteristic curve analysis.Results In total,80 orbits from 44 DON patients and 90 orbits from 45 TAO patients were included in our study.Two variables(optic nerve subarachnoid space and the volume of the CSF in the optic nerve sheath)were found to be independent predictive factors and were included in the prediction model.In the development cohort,the mean area under the curve(AUC)was 0.994,with a sensitivity of 0.944,specificity of 0.967,and accuracy of 0.901.Moreover,in the validation cohort,the AUC was 0.960,the sensitivity was 0.889,the specificity was 0.893,and the accuracy was 0.890.Conclusions A combined model was developed using imaging data of the optic nerve and CSF in the optic nerve sheath,serving as a noninvasive potential tool to predict DON.展开更多
The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning l...The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning laser ophthalmoscope(AOSLO)provides an excellent tool to acquire accurate and detailed information about the parafoveal area with cellular resolution.However,limited by the scanning speed of two-dimensional scanning,thefield of view(FOV)in the AOSLO system was usually less than or equal to 2,and the stitching for the parafoveal area required dozens of images,which was time-consuming and laborious.Unfortunately,almost half of patients are unable to obtain stitched images because of their poorfixation.To solve this problem,we integrate AO technology with the line-scan imaging method to build an adaptive optics line scanning ophthalmoscope(AOLSO)system with a larger FOV.In the AOLSO,afocal spherical mirrors in pairs are nonplanar arranged and the distance and angle between optical elements are optimized to minimize the aberrations,two cylinder lenses are orthogonally placed before the imaging sensor to stretch the point spread function(PSF)for sufficiently digitizing light energy.Captured human retinal images show the whole parafoveal area with 55FOV,60 Hz frame rate and cellular resolutions.Take advantage of the 5FOV of the AOLSO,only 9 frames of the retina are captured with several minutes to stitch a montage image with an FOV of 99,in which photoreceptor counting is performed within approximately 5eccentricity.The AOLSO system not only provides cellular resolution but also has the capability to capture the parafoveal region in a single frame,which offers great potential for noninvasive studying of the parafoveal area.展开更多
Optical imaging systems have greatly extended human visual capabilities,enabling the observation and understanding of diverse phenomena.Imaging technologies span a broad spectrum of wavelengths from x-ray to radio fre...Optical imaging systems have greatly extended human visual capabilities,enabling the observation and understanding of diverse phenomena.Imaging technologies span a broad spectrum of wavelengths from x-ray to radio frequencies and impact research activities and our daily lives.Traditional glass lenses are fabricated through a series of complex processes,while polymers offer versatility and ease of production.However,modern applications often require complex lens assemblies,driving the need for miniaturization and advanced designs with micro-and nanoscale features to surpass the capabilities of traditional fabrication methods.Three-dimensional(3D)printing,or additive manufacturing,presents a solution to these challenges with benefits of rapid prototyping,customized geometries,and efficient production,particularly suited for miniaturized optical imaging devices.Various 3D printing methods have demonstrated advantages over traditional counterparts,yet challenges remain in achieving nanoscale resolutions.Two-photon polymerization lithography(TPL),a nanoscale 3D printing technique,enables the fabrication of intricate structures beyond the optical diffraction limit via the nonlinear process of two-photon absorption within liquid resin.It offers unprecedented abilities,e.g.alignment-free fabrication,micro-and nanoscale capabilities,and rapid prototyping of almost arbitrary complex 3D nanostructures.In this review,we emphasize the importance of the criteria for optical performance evaluation of imaging devices,discuss material properties relevant to TPL,fabrication techniques,and highlight the application of TPL in optical imaging.As the first panoramic review on this topic,it will equip researchers with foundational knowledge and recent advancements of TPL for imaging optics,promoting a deeper understanding of the field.By leveraging on its high-resolution capability,extensive material range,and true 3D processing,alongside advances in materials,fabrication,and design,we envisage disruptive solutions to current challenges and a promising incorporation of TPL in future optical imaging applications.展开更多
To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected...To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.展开更多
Multispectral and polarization cameras that can simultaneously acquire the spatial,spectral,and polarization characteristics of an object have considerable potential applications in target detection,biomedical imaging...Multispectral and polarization cameras that can simultaneously acquire the spatial,spectral,and polarization characteristics of an object have considerable potential applications in target detection,biomedical imaging,and remote sensing.In this work,we develop a common-aperture optical system that can capture multispectral and polarization information.An off-axis three-mirror optical system is mounted on the front end of the proposed system and used as a common-aperture telescope in the visible light(400 nm-750 nm)and long-wave infrared(LWIR,8μm-12μm)waveband.The system can maintain a wide field of view(4.5°)and it can demonstrate an enhanced identification ability.The off-axis three-mirror system gets rid of central obscuration while further yielding stable system resolution and energy.Light that has passed through the front-end common-aperture reflection system is divided into the visible light and LWIR waveband by a beamsplitter.The two wavebands then converge on two detectors through two groups of lenses.Our simulation results indicate that the proposed system can obtain clear images in each waveband to meet the diverse imaging requirements.展开更多
For conventional optical polarization imaging of underwater target,the polarization degree of backscatter should be pre-measured by averaging the pixel intensities in the no target region of the polarization images,an...For conventional optical polarization imaging of underwater target,the polarization degree of backscatter should be pre-measured by averaging the pixel intensities in the no target region of the polarization images,and the polarization property of the target is assumed to be completely depolarized.When the scattering background is unseen in the field of view or the target is polarized,conventional method is helpless in detecting the target.An improvement is to use lots of co-polarization and cross polarization detection components.We propose a polarization subtraction method to estimate depolarization property of the scattering noise and target signal.And experiment in a quartz cuvette container is performed to demonstrate the effectiveness of the proposed method.The results show that the proposed method can work without scattering background reference,and further recover the target along with smooth surface for polarization preserving response.This study promotes the development of optical polarization imaging systems in underwater environments.展开更多
AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor m...AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor metabolic activity using a fluorodeoxyglucose analogue as 2-deoxyglucosone fluorescent probes and to correlate it with tumoral volume(mm^3). Inflammation measuring myeloperoxidase(MPO) activity and reactive oxygen species production was monitored by a bioluminescent(BLI) inflammation probe and related to histological examination and MPO levels by enzyme-linked immunosorbent assay(ELISA) on tumor specimens. The detection and quantitation of these two signals were validated on a xenograft model of human colon adenocarcinoma epithelial cells(HCT116) in nude mice infected with a pks-positive E. coli. The inflammatory BLI signal was validated intra-digestively in the colitisCEABAC10 DSS models, which mimicked Crohn's disease. RESULTS: Using a 2-deoxyglucosone fluorescent probe, we observed a high and specific HCT116 tumor uptake in correlation with tumoral volume(P = 0.0036). Using the inflammation probe targeting MPO, we detected a rapid systemic elimination and a significant increase of the BLI signal in the pks-positive E. coli-infected HCT116 xenograft group(P < 0.005). ELISA confirmed that MPO levels were significantly higher(1556 ± 313.6 vs 234.6 ± 121.6 ng/m L P = 0.001) in xenografts infected with the pathogenic E. coli strain. Moreover, histological examination of tumor samples confirmed massive infiltration of pks-positive E. coli-infected HCT116 tumors by inflammatory cells compared to the uninfected group. These data showed that infection with the pathogenic E. coli strain enhanced inflammation and ROS production in tumors before tumor growth. Moreover, we demonstrated that the intra-digestive monitoring of inflammation is feasible in a reference colitis murine model(CEABAC10/DSS).CONCLUSION: Using BLI and fluorescence optical imaging, we provided tools to better understand hostpathogen interactions at the early stage of disease, such as inflammatory bowel disease and colorectal cancer.展开更多
Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,rea...Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,real-time and high-resolution imaging technology.In this study,in order to assess the feasibility of OCT in oral clinical application,fresh excised tissue specimens from 59 patients undergoing oral-maxillofacial surgery were imaged in detail by using a benchtop sweptsource OCT system.It is shown that different lesions or tissues can be obviously distinguished based on their different microstructural features in OCT images,and the features are similar to those of their corresponding histopathological images.It is proven that OCT has great feasibility and potential as a diagnostic aid for surgeons in oral medicine.展开更多
Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them...Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them into tumor sites and noninvasively visualize their in vivo biodistribution with excellent sensitivity and accuracy for effective cancer diagnosis. In this study, we design a yolk/shell-structured silica nanosystem ^(64) Cu-NOTAQD@HMSN-PEG-TRC105, which can be employed for tumor vasculature targeting and dual-modality PET/optical imaging, leading to superior targeting specificity, excellentimaging capability and more reliable diagnostic outcomes.By combining vasculature targeting, pH-sensitive drug delivery, and dual-modality imaging into a single platform,as-designed yolk/shell-structured silica nanosystems may be employed for the future image-guided tumor-targeted drug delivery, to further enable cancer theranostics.展开更多
The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC...The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional QCT and complex Fourier-domain optical coherence to- mography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.展开更多
The effect of optical cleaning method combined with laser speckle imaging(LSI)was discussed to improve the detection depth of LSI due to high scattering characteristics of skin,which limit its clinical application.A d...The effect of optical cleaning method combined with laser speckle imaging(LSI)was discussed to improve the detection depth of LSI due to high scattering characteristics of skin,which limit its clinical application.A double-layer skin tissue model embedded with a single blood vessel was established,and the Monte Carlo method was used to simulate photon propagation under the action of light-permeating agent.808 nm semiconductor and 632.8 nm He–Ne lasers were selected to study the e®ect of optical clearing agents(OCAs)on photon deposition in tissues.Results show that the photon energy deposition density in the epidermis increases with the amount of tissue°uid replaced by OCA.Compared with glucose solution,polyethylene glycol 400(PEG 400)and glycerol can considerably increase the average penetration depth of photons in the skin tissue,thereby raising the sampling depth of the LSI.After the action of glycerol,PEG 400,and glucose,the average photon penetration depth is increased by 51.78%,51.06%,and 21.51%for 808nm,68.93%,67.94%,and 26.67%for 632.8 nm lasers,respectively.In vivo experiment by dorsal skin chamber proves that glycerol can cause a substantial decrease in blood°ow rate,whereas PEG 400 can signicantly improve the capability of light penetration without a®ecting blood velocity,which exhibits considerable potential in the monitoring of blood°ow in skin tissues.展开更多
The principle of ptychography is applied in known plain text attack on the double random phase encoding (DRPE) system. We find that with several pairs of plain texts and cipher texts, the model of attack on DRPE can...The principle of ptychography is applied in known plain text attack on the double random phase encoding (DRPE) system. We find that with several pairs of plain texts and cipher texts, the model of attack on DRPE can be converted to the model of ptyehographical imaging. Owing to the inherent merits of the ptyehographical imaging, the DRPE system can be breached totally in a fast and nearly perfect way, which is unavailable for currently existing attack methods. Further, since the decryption keys can be seen as an object to be imaged from the perspective of imaging, the ptychographical technique may be a kind of new direction to further analysis of the security of other encryption systems based on double random keys.展开更多
AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical c...AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.展开更多
基金funding from the National Natural Science Foundation of China(NSFC)under grants 61627827,61705068the Natural Science Foundation of Fujian Province 2021J01813the Fujian Medical University Research Foundation of Talented Scholars XRCZX2021004.
文摘In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications.
文摘In a single-pixel fast imaging setup,the data collected by the single-pixel detector needs to be processed by a computer,but the speed of the latter will affect the image reconstruction time.Here we propose two kinds of setups which are able to transform non-visible into visible light imaging,wherein their computing process is replaced by a camera integration mode.The image captured by the camera has a low contrast,so here we present an algorithm that can realize a high quality image in near-infrared to visible cross-waveband imaging.The scheme is verified both by simulation and in actual experiments.The setups demonstrate the great potential for single-pixel imaging and high-speed cross-waveband imaging for future practical applications.
基金National Natural Science Foundation of China (Nos.61871353 and 42006164)for their support。
文摘Internal solitary waves(ISWs)change the roughness of the sea surface,thus producing dark and bright bands in optical images.However,reasons for changes in imaging characteristics with the solar zenith angle remain unclear.In this paper,the optical imaging pattern of ISWs in sunglint under different zenith angles of the light source is investigated by collecting optical images of ISWs through physical simulation.The experiment involves setting 10 zenith angles of the light source,which are divided into area a the optical images of ISWs in the three areas show dark-bright mode,single bright band,and bright-dark mode,which are consistent with those observed by optical remote sensing.In addition,this study analyzed the percentage of the dark and bright areas of the bands and the change in the relative gray difference and found changes in both areas under different zenith angles of the light source.The MODIS and ASAR images display a similar brightness-darkness distance of the same ISWs.Therefore,the relationship between the brightness-darkness distance and the characteristic half-width of ISWs is determined in accordance with the eKdV theory and the imaging mechanism of ISWs of the SAR image.Overall,the relationship between them in the experiment is almost consistent with the theoretical result.
基金support from the National Key Research and Development Program of China(Grant No.2017YFA0700501),and the Innovation Fund of WNLO.
文摘Three-dimensional(3D)cell cultures have contributed to a variety of biological research fields by filling the gap between monolayers and animal models.The modern optical sectioning microscopic methods make it possible to probe the complexity of 3D cell cultures but are limited by the inherent opaqueness.While tissue optical clearing methods have emerged as powerful tools for investigating whole-mount tissues in 3D,they often have limitations,such as being too harsh for fragile 3D cell cultures,requiring complex handling protocols,or inducing tissue deformation with shrinkage or expansion.To address this issue,we proposed a modified optical clearing method for 3D cell cultures,called MACS-W,which is simple,highly efficient,and morphology-preserving.In our evaluation of MACS-W,we found that it exhibits excellent clearing capability in just 10 min,with minimal deformation,and helps drug evaluation on tumor spheroids.In summary,MACS-W is a fast,minimally-deformative and fluorescence compatible clearing method that has the potential to be widely used in the studies of 3D cell cultures.
基金supported by University of Macao,China,Nos.MYRG2022-00054-FHS and MYRG-GRG2023-00038-FHS-UMDF(to ZY)the Macao Science and Technology Development Fund,China,Nos.FDCT0048/2021/AGJ and FDCT0020/2019/AMJ and FDCT 0011/2018/A1(to ZY)Natural Science Foundation of Guangdong Province of China,No.EF017/FHS-YZ/2021/GDSTC(to ZY)。
文摘To investigate the mechanisms underlying the onset and progression of ischemic stroke,some methods have been proposed that can simultaneously monitor and create embolisms in the animal cerebral cortex.However,these methods often require complex systems and the effect of age on cerebral embolism has not been adequately studied,although ischemic stroke is strongly age-related.In this study,we propose an optical-resolution photoacoustic microscopy-based visualized photothrombosis methodology to create and monitor ischemic stroke in mice simultaneously using a 532 nm pulsed laser.We observed the molding process in mice of different ages and presented age-dependent vascular embolism differentiation.Moreover,we integrated optical coherence tomography angiography to investigate age-associated trends in cerebrovascular variability following a stroke.Our imaging data and quantitative analyses underscore the differential cerebrovascular responses to stroke in mice of different ages,thereby highlighting the technique's potential for evaluating cerebrovascular health and unraveling age-related mechanisms involved in ischemic strokes.
基金supported by the National Natural Science Foundation of China(62375144 and 61875092)Tianjin Foundation of Natural Science(21JCYBJC00260)Beijing-Tianjin-Hebei Basic Research Cooperation Special Program(19JCZDJC65300).
文摘Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness.
基金The Key R&D Project of Hainan Province under contract No.ZDYF2023SHFZ097the National Natural Science Foundation of China under contract No.42376180。
文摘Mangroves are indispensable to coastlines,maintaining biodiversity,and mitigating climate change.Therefore,improving the accuracy of mangrove information identification is crucial for their ecological protection.Aiming at the limited morphological information of synthetic aperture radar(SAR)images,which is greatly interfered by noise,and the susceptibility of optical images to weather and lighting conditions,this paper proposes a pixel-level weighted fusion method for SAR and optical images.Image fusion enhanced the target features and made mangrove monitoring more comprehensive and accurate.To address the problem of high similarity between mangrove forests and other forests,this paper is based on the U-Net convolutional neural network,and an attention mechanism is added in the feature extraction stage to make the model pay more attention to the mangrove vegetation area in the image.In order to accelerate the convergence and normalize the input,batch normalization(BN)layer and Dropout layer are added after each convolutional layer.Since mangroves are a minority class in the image,an improved cross-entropy loss function is introduced in this paper to improve the model’s ability to recognize mangroves.The AttU-Net model for mangrove recognition in high similarity environments is thus constructed based on the fused images.Through comparison experiments,the overall accuracy of the improved U-Net model trained from the fused images to recognize the predicted regions is significantly improved.Based on the fused images,the recognition results of the AttU-Net model proposed in this paper are compared with its benchmark model,U-Net,and the Dense-Net,Res-Net,and Seg-Net methods.The AttU-Net model captured mangroves’complex structures and textural features in images more effectively.The average OA,F1-score,and Kappa coefficient in the four tested regions were 94.406%,90.006%,and 84.045%,which were significantly higher than several other methods.This method can provide some technical support for the monitoring and protection of mangrove ecosystems.
基金supported financially by grants from the National Natural Science Foundation of China(No.81771793).
文摘Objective This study aimed to develop and test a model for predicting dysthyroid optic neuropathy(DON)based on clinical factors and imaging markers of the optic nerve and cerebrospinal fluid(CSF)in the optic nerve sheath.Methods This retrospective study included patients with thyroid-associated ophthalmopathy(TAO)without DON and patients with TAO accompanied by DON at our hospital.The imaging markers of the optic nerve and CSF in the optic nerve sheath were measured on the water-fat images of each patient and,together with clinical factors,were screened by Least absolute shrinkage and selection operator.Subsequently,we constructed a prediction model using multivariate logistic regression.The accuracy of the model was verified using receiver operating characteristic curve analysis.Results In total,80 orbits from 44 DON patients and 90 orbits from 45 TAO patients were included in our study.Two variables(optic nerve subarachnoid space and the volume of the CSF in the optic nerve sheath)were found to be independent predictive factors and were included in the prediction model.In the development cohort,the mean area under the curve(AUC)was 0.994,with a sensitivity of 0.944,specificity of 0.967,and accuracy of 0.901.Moreover,in the validation cohort,the AUC was 0.960,the sensitivity was 0.889,the specificity was 0.893,and the accuracy was 0.890.Conclusions A combined model was developed using imaging data of the optic nerve and CSF in the optic nerve sheath,serving as a noninvasive potential tool to predict DON.
基金supported by the National Natural Science Foundation of China under Grant No.62075235,National Key R&D Program of China under Grant No.2021YFF0700700Gusu Innovation and Entrepreneurship Leading Talents in Suzhou City under Grant No.ZXL2021425+1 种基金Youth Innovation Promotion Association of the Chinese Academy of Sciences under Grant No.2019320Innovation of Scientific Research Strategic Priority Research Program of the Chinese Academy of Sciences under Grant No.XDA15021304.
文摘The parafoveal area,with its high concentration of photoreceptors andfine retinal capillaries,is crucial for central vision and often exhibits early signs of pathological changes.The current adaptive optics scanning laser ophthalmoscope(AOSLO)provides an excellent tool to acquire accurate and detailed information about the parafoveal area with cellular resolution.However,limited by the scanning speed of two-dimensional scanning,thefield of view(FOV)in the AOSLO system was usually less than or equal to 2,and the stitching for the parafoveal area required dozens of images,which was time-consuming and laborious.Unfortunately,almost half of patients are unable to obtain stitched images because of their poorfixation.To solve this problem,we integrate AO technology with the line-scan imaging method to build an adaptive optics line scanning ophthalmoscope(AOLSO)system with a larger FOV.In the AOLSO,afocal spherical mirrors in pairs are nonplanar arranged and the distance and angle between optical elements are optimized to minimize the aberrations,two cylinder lenses are orthogonally placed before the imaging sensor to stretch the point spread function(PSF)for sufficiently digitizing light energy.Captured human retinal images show the whole parafoveal area with 55FOV,60 Hz frame rate and cellular resolutions.Take advantage of the 5FOV of the AOLSO,only 9 frames of the retina are captured with several minutes to stitch a montage image with an FOV of 99,in which photoreceptor counting is performed within approximately 5eccentricity.The AOLSO system not only provides cellular resolution but also has the capability to capture the parafoveal region in a single frame,which offers great potential for noninvasive studying of the parafoveal area.
基金support from the National Research Foundation (NRF) Singapore, under its Competitive Research Programme Award NRF-CRP20-20170004 and NRF Investigatorship Award NRF-NRFI06-20200005MTC Programmatic Grant M21J9b0085, as well as the Lite-On Project RS-INDUS-00090+5 种基金support from Australian Research Council (DE220101085, DP220102152)grants from German Research Foundation (SCHM2655/15-1, SCHM2655/21-1)Lee-Lucas Chair in Physics and funding by the Australian Research Council DP220102152financial support from the National Natural Science Foundation of China (Grant No. 62275078)Natural Science Foundation of Hunan Province of China (Grant No. 2022JJ20020)Shenzhen Science and Technology Program (Grant No. JCYJ20220530160405013)
文摘Optical imaging systems have greatly extended human visual capabilities,enabling the observation and understanding of diverse phenomena.Imaging technologies span a broad spectrum of wavelengths from x-ray to radio frequencies and impact research activities and our daily lives.Traditional glass lenses are fabricated through a series of complex processes,while polymers offer versatility and ease of production.However,modern applications often require complex lens assemblies,driving the need for miniaturization and advanced designs with micro-and nanoscale features to surpass the capabilities of traditional fabrication methods.Three-dimensional(3D)printing,or additive manufacturing,presents a solution to these challenges with benefits of rapid prototyping,customized geometries,and efficient production,particularly suited for miniaturized optical imaging devices.Various 3D printing methods have demonstrated advantages over traditional counterparts,yet challenges remain in achieving nanoscale resolutions.Two-photon polymerization lithography(TPL),a nanoscale 3D printing technique,enables the fabrication of intricate structures beyond the optical diffraction limit via the nonlinear process of two-photon absorption within liquid resin.It offers unprecedented abilities,e.g.alignment-free fabrication,micro-and nanoscale capabilities,and rapid prototyping of almost arbitrary complex 3D nanostructures.In this review,we emphasize the importance of the criteria for optical performance evaluation of imaging devices,discuss material properties relevant to TPL,fabrication techniques,and highlight the application of TPL in optical imaging.As the first panoramic review on this topic,it will equip researchers with foundational knowledge and recent advancements of TPL for imaging optics,promoting a deeper understanding of the field.By leveraging on its high-resolution capability,extensive material range,and true 3D processing,alongside advances in materials,fabrication,and design,we envisage disruptive solutions to current challenges and a promising incorporation of TPL in future optical imaging applications.
文摘To verify the effectiveness of digital optical 3D image analyzer EvaSKIN in the objective and quantitative evaluation of wrinkles.A total of 115 subjects were recruited,the facial images of the subjects were collected by digital optical 3D image analyzer and manual camera,the changes of crow’s feet with age were analyzed.Pictures obtained by manual photography can be directly used for observation and preliminary grading of wrinkles.However,the requirements for evaluators are high,and the results are prone to errors,which will affect the accuracy of the evaluation.Therefore,skilled raters are needed.Compared with the manual photography method,the digital optical 3D image analyzer EvaSKIN can realize three-dimensional extraction of wrinkles,and obtain the change trend of crow’s feet with age.20~30 years old,wrinkles begin to appear slowly;wrinkles will increase rapidly at the age of 30~50;The length of 50~60 year old wrinkles is basically fixed,the wrinkles develop longitudewise,gradually widen and deepen,and the area,depth and volume increase is obvious,and the skin aging condition is intensified.the digital optical 3D image analyzer EvaSKIN realizes the 3D extraction of wrinkles,quantifies the circumference,area,average depth,maximum depth and volume of wrinkles,realizes the objective and quantitative evaluation of wrinkle state,is more accurate in the measurement of wrinkles,and provides a new instrument and method for the evaluation of wrinkles.it is a perfect and supplement to the traditional evaluation methods,and to a certain extent,it helps the research and development and evaluation institutions of cosmetics to obtain more abundant and three-dimensional data support.
基金Project supported by the National Natural Science Foundation of china(Grant No.61471039)
文摘Multispectral and polarization cameras that can simultaneously acquire the spatial,spectral,and polarization characteristics of an object have considerable potential applications in target detection,biomedical imaging,and remote sensing.In this work,we develop a common-aperture optical system that can capture multispectral and polarization information.An off-axis three-mirror optical system is mounted on the front end of the proposed system and used as a common-aperture telescope in the visible light(400 nm-750 nm)and long-wave infrared(LWIR,8μm-12μm)waveband.The system can maintain a wide field of view(4.5°)and it can demonstrate an enhanced identification ability.The off-axis three-mirror system gets rid of central obscuration while further yielding stable system resolution and energy.Light that has passed through the front-end common-aperture reflection system is divided into the visible light and LWIR waveband by a beamsplitter.The two wavebands then converge on two detectors through two groups of lenses.Our simulation results indicate that the proposed system can obtain clear images in each waveband to meet the diverse imaging requirements.
基金National Natural Science Foundation of China(Nos.11847069,11847127)Science Foundation of North University of China(No.XJJ20180030)。
文摘For conventional optical polarization imaging of underwater target,the polarization degree of backscatter should be pre-measured by averaging the pixel intensities in the no target region of the polarization images,and the polarization property of the target is assumed to be completely depolarized.When the scattering background is unseen in the field of view or the target is polarized,conventional method is helpless in detecting the target.An improvement is to use lots of co-polarization and cross polarization detection components.We propose a polarization subtraction method to estimate depolarization property of the scattering noise and target signal.And experiment in a quartz cuvette container is performed to demonstrate the effectiveness of the proposed method.The results show that the proposed method can work without scattering background reference,and further recover the target along with smooth surface for polarization preserving response.This study promotes the development of optical polarization imaging systems in underwater environments.
基金Supported by Veziant J was supported by«année-recherche»grants from the Ministère de la Santéand the Facultéde Médecine de Clermont-FerrandGagnière J was supported by a“Nuovo Soldati Foundation for Cancer Research”grant.
文摘AIM: To investigate the molecular or cellular mechanisms related to the infection of epithelial colonic mucosa by pks-positive Escherichia coli(E. coli) using optical imaging.METHODS: We choose to evaluate the tumor metabolic activity using a fluorodeoxyglucose analogue as 2-deoxyglucosone fluorescent probes and to correlate it with tumoral volume(mm^3). Inflammation measuring myeloperoxidase(MPO) activity and reactive oxygen species production was monitored by a bioluminescent(BLI) inflammation probe and related to histological examination and MPO levels by enzyme-linked immunosorbent assay(ELISA) on tumor specimens. The detection and quantitation of these two signals were validated on a xenograft model of human colon adenocarcinoma epithelial cells(HCT116) in nude mice infected with a pks-positive E. coli. The inflammatory BLI signal was validated intra-digestively in the colitisCEABAC10 DSS models, which mimicked Crohn's disease. RESULTS: Using a 2-deoxyglucosone fluorescent probe, we observed a high and specific HCT116 tumor uptake in correlation with tumoral volume(P = 0.0036). Using the inflammation probe targeting MPO, we detected a rapid systemic elimination and a significant increase of the BLI signal in the pks-positive E. coli-infected HCT116 xenograft group(P < 0.005). ELISA confirmed that MPO levels were significantly higher(1556 ± 313.6 vs 234.6 ± 121.6 ng/m L P = 0.001) in xenografts infected with the pathogenic E. coli strain. Moreover, histological examination of tumor samples confirmed massive infiltration of pks-positive E. coli-infected HCT116 tumors by inflammatory cells compared to the uninfected group. These data showed that infection with the pathogenic E. coli strain enhanced inflammation and ROS production in tumors before tumor growth. Moreover, we demonstrated that the intra-digestive monitoring of inflammation is feasible in a reference colitis murine model(CEABAC10/DSS).CONCLUSION: Using BLI and fluorescence optical imaging, we provided tools to better understand hostpathogen interactions at the early stage of disease, such as inflammatory bowel disease and colorectal cancer.
基金supported by National Natural Science Foundation of China(NSFC)(61875092 and 11374167)State Key Project of Research and Development Plan(2016YFC0101002)+1 种基金Science and Technology Support Program of Tianjin(17YFZCSY00740)Fundamental Research Funds for the Central Universities of Nankai University(63191203).
文摘Histopathological examination is still the gold standard for diagnoses of oral-maxillofacial lesions,but it is invasive and time-consuming.Optical coherence tomography(OCT)provides a kind of noninvasive,label-free,real-time and high-resolution imaging technology.In this study,in order to assess the feasibility of OCT in oral clinical application,fresh excised tissue specimens from 59 patients undergoing oral-maxillofacial surgery were imaged in detail by using a benchtop sweptsource OCT system.It is shown that different lesions or tissues can be obviously distinguished based on their different microstructural features in OCT images,and the features are similar to those of their corresponding histopathological images.It is proven that OCT has great feasibility and potential as a diagnostic aid for surgeons in oral medicine.
基金supported,in part,by the University of Wisconsin–Madisonthe National Institutes of Health (P30CA014520 and T32CA009206)the American Cancer Society (125246-RSG-13-099-01-CCE)
文摘Silica nanoparticles have been one of the most promising nanosystems for biomedical applications due to their facile surface chemistry and non-toxic nature. However, it is still challenging to effectively deliver them into tumor sites and noninvasively visualize their in vivo biodistribution with excellent sensitivity and accuracy for effective cancer diagnosis. In this study, we design a yolk/shell-structured silica nanosystem ^(64) Cu-NOTAQD@HMSN-PEG-TRC105, which can be employed for tumor vasculature targeting and dual-modality PET/optical imaging, leading to superior targeting specificity, excellentimaging capability and more reliable diagnostic outcomes.By combining vasculature targeting, pH-sensitive drug delivery, and dual-modality imaging into a single platform,as-designed yolk/shell-structured silica nanosystems may be employed for the future image-guided tumor-targeted drug delivery, to further enable cancer theranostics.
文摘The parallel spectral-domain optical coherence tomography(PSDOCT) is described for highspeed optical coherence tomography(OCT) without lateral scanning. In this setup, the self-elimination of auto-correlation(AC) interference algorithm was used for eradicating the AC interference and ghost images. However, when performed in free space OCT, this algorithm still generated a weak DC component. The algorithm was improved by adding the background intensity part to compensate for the mutual interference between object and reference arms. The results demonstrate that the DC component can be eradicated. Compared with conventional QCT and complex Fourier-domain optical coherence to- mography, the advantages of PSDOCT with the improved algorithm in free space are that it has no moving parts to generate consecutive phase shift, the structure of the object can be reconstructed immediately and automatically, and the speed is approximately 16 times faster than those of the other two in the same case.
基金supported by the National Natural Science Foundation of China(Grant No.51727811).
文摘The effect of optical cleaning method combined with laser speckle imaging(LSI)was discussed to improve the detection depth of LSI due to high scattering characteristics of skin,which limit its clinical application.A double-layer skin tissue model embedded with a single blood vessel was established,and the Monte Carlo method was used to simulate photon propagation under the action of light-permeating agent.808 nm semiconductor and 632.8 nm He–Ne lasers were selected to study the e®ect of optical clearing agents(OCAs)on photon deposition in tissues.Results show that the photon energy deposition density in the epidermis increases with the amount of tissue°uid replaced by OCA.Compared with glucose solution,polyethylene glycol 400(PEG 400)and glycerol can considerably increase the average penetration depth of photons in the skin tissue,thereby raising the sampling depth of the LSI.After the action of glycerol,PEG 400,and glucose,the average photon penetration depth is increased by 51.78%,51.06%,and 21.51%for 808nm,68.93%,67.94%,and 26.67%for 632.8 nm lasers,respectively.In vivo experiment by dorsal skin chamber proves that glycerol can cause a substantial decrease in blood°ow rate,whereas PEG 400 can signicantly improve the capability of light penetration without a®ecting blood velocity,which exhibits considerable potential in the monitoring of blood°ow in skin tissues.
基金Supported by the National Natural Science Foundation of China under Grant Nos 61575197 and 61307018the K.C.Wong Education Foundation,the President Fund of University of Chinese Academy of Sciencesthe Fusion Funds of Research and Education of Chinese Academy of Sciences
文摘The principle of ptychography is applied in known plain text attack on the double random phase encoding (DRPE) system. We find that with several pairs of plain texts and cipher texts, the model of attack on DRPE can be converted to the model of ptyehographical imaging. Owing to the inherent merits of the ptyehographical imaging, the DRPE system can be breached totally in a fast and nearly perfect way, which is unavailable for currently existing attack methods. Further, since the decryption keys can be seen as an object to be imaged from the perspective of imaging, the ptychographical technique may be a kind of new direction to further analysis of the security of other encryption systems based on double random keys.
基金Supported by Wenzhou Municipal Science and Technology Bureau(No.Y20150257)
文摘AIM:To assess peripapillary retinal nerve fiber layer(RNFL)and choroidal thickness obtained with enhanced depth imaging(EDI)mode compared with those obtained without EDI mode using Heidelberg Spectralis optical coherence tomography(OCT).METHODS:Fifty eyes of 25 normal healthy subjects and32 eyes of 20 patients with different eye diseases were included in the study.All subjects underwent 3.4 mm diameter peripapillary circular OCT scan centered on the optic disc using both the conventional and the EDI OCT protocols.The visualization of RNFL and choroidoscleral junction was assessed using an ordinal scoring scale.The paired t-test,intraclass correlation coefficient(ICC),95%limits of agreement(LoA),and Bland and Altman plots were used to test the agreement of measurements.RESULTS:The visibility score of RNFL obtained with and without EDI was of no significant difference(P=0.532),the visualization of choroidoscleral junction was better using EDI protocol than conventional protocol(P〈0.001).Peripapillary RNFL thickness obtained with EDI was slightly thicker than that obtained without EDI(103.25±9.42μm vs 101.87±8.78μm,P=0.010).The ICC of the two protocols was excellent with the value of 0.867 to 0.924,the 95%LoA of global RNFL thickness was between-10.0 to 7.4μm.Peripapillary choroidal thickness obtained with EDI was slightly thinner than that obtained without EDI(147.23±51.04μm vs 150.90±51.84μm,P〈0.001).The ICC was also excellent with the value of 0.960 to 0.987,the 95%LoA of global choroidal thickness was between-12.5 to 19.8μm.CONCLUSION:Peripapillary circular OCT scan with or without EDI mode shows comparable results in the measurement of peripapillary RNFL and choroidal thickness.