A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/me...A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra.展开更多
Simple procedures for extraction and chromatographic determination of dimethachlon residues in fresh tobacco leaves and cut-tobacco are described.The determination was carried out by capillary gas chromatography(GC) w...Simple procedures for extraction and chromatographic determination of dimethachlon residues in fresh tobacco leaves and cut-tobacco are described.The determination was carried out by capillary gas chromatography(GC) with electron capture detection(ECD) and confirmed by GC-MS.The mean recoveries and relative standard deviation(RSD) were 93.2%~112.9% and 3.5%~6.7%,respectively at levels ranging from 0.01 to 0.1 mg/kg.The limit of determination was 0.001 mg/kg.Tobacco samples in routine check were successfully analyzed using the proposed method.展开更多
Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively...Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.展开更多
Gas chromatography (GC) analysis of sulfer dioxide is challenging because SO2 is a highly mobile and chemically active molecule. For the conventional GC method with flame photometric detector (FPD) and direct-inje...Gas chromatography (GC) analysis of sulfer dioxide is challenging because SO2 is a highly mobile and chemically active molecule. For the conventional GC method with flame photometric detector (FPD) and direct-injection, it is often ineffective particularly when the SO2 level is as low as on the trace level. In this paper, a modified GC system integrated with an adsorption-desorption device was developed to detect the trace SO2 impurity in H2 fuel. Adsorbent GDX-502 is used in the adsorber to adsorb/collect SO2 from the sample gas and desorb/release it in a concentrated flow so that the conventional GC at downstream could detect it with an acceptable accuracy.展开更多
[Objective] This study aimed to analyze the chemical composition and yield of essential oil and n-hexane extract from moso bamboo to find active compounds with potential value. [Method] Essential oil and n-hexane extr...[Objective] This study aimed to analyze the chemical composition and yield of essential oil and n-hexane extract from moso bamboo to find active compounds with potential value. [Method] Essential oil and n-hexane extract were respectively extracted from moso bamboo of four different ages by using hydrodistillation and ultrasonic-assisted extraction with n-hexane, and analyzed with gas chromatography/mass spectrometry (GC/MS). [Result] The results show that cedrol (46.39%) is the first principal volatile component in essential oil of the middle stem of 7-year old moso bamboo; dibutyl phthalate (59.46%) is the first principal volatile component in n-hexane extract of the middle stem of 3-year old moso bamboo; yield of n-hexane extract is higher than that of essential oil from moso bamboo. [Conclusion] Cedrol is an active compound with potential value.展开更多
Heavy biodegraded crude oils have larger numbers of coeluting compounds than nonbiodegraded oils, and they are typically not resolved with conventional gas chromatography(GC). This unresolved complex mixture(UCM) ...Heavy biodegraded crude oils have larger numbers of coeluting compounds than nonbiodegraded oils, and they are typically not resolved with conventional gas chromatography(GC). This unresolved complex mixture(UCM) has been investigated using comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry(GC×GC-To FMS) within a set of biodegraded petroleums derived from distinct sedimentary basins, including northwestern Sichuan(Neoproterozoic, marine), Tarim(Early Paleozoic, marine), Bohai Bay(Eocene, saline/brackish) and Pearl River Mouth(Eocene, freshwater). In general, the hydrocarbons that constitute the UCM in petroleum saturate fractions can be classified into three catalogues based on the distributions of resolved compounds on two dimensional chromatograms. Group 1 is composed mainly of normal and branched alkanes, isoprenoid alkanes and monocyclic alkanes; Group 2 comprises primarily terpanes ranging from two to five rings, and Group 3 is dominated by monoaromatic hydrocarbons such as tetralins and monoaromatic steranes. In addition, the UCM is source dependent and varies between oil populations. i.e., the UCM of petroleum derived from Precambrian and Early Paleozoic marine, Eocene saline/brackish and freshwater source rocks is specifically rich in higher homologues of A-norsteranes, series of 1,1,3-trimethyl-2-alkylcyclohexanes(carotenoid-derived alkanes), and tetralin and indane compounds, respectively.展开更多
The solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) was used to determine and analyze organic pollutants in coking wastewater. Based on the fact that the main compound...The solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) was used to determine and analyze organic pollutants in coking wastewater. Based on the fact that the main compounds in the wastewater were organics, some key parameters of the SPME were optimized. The method has good linearity ( its correlation coefficients 〉 0.99) in the range determined,its relative standard deviations (RSD) are less than 15%, and its recovery is from 87.9% to 128.1% with the lowest quantification limit of 5 ~g/L. This method has been used to measure 15 organic pollutants in wastewater from a certain coking plant. The results show that compared with the conventional method,it can save an hour in pretreatment time. It is a fast, low-cost, accurate, simple and efficient analytical method indeed.展开更多
[Objectives] To analyze volatile components of flowers and leaves of Thymus mongolicus. [Methods]Volatile components of collected T. mongolicus flower and leaves were separated by headspace solid-phase microextraction...[Objectives] To analyze volatile components of flowers and leaves of Thymus mongolicus. [Methods]Volatile components of collected T. mongolicus flower and leaves were separated by headspace solid-phase microextraction( SPME) and identified by gas chromatography/mass spectrometry( GC/MS) and normallized by peak area. [Results] A total of 24 and 14 compounds were identified from flowers and leaves of T. mongolicus in the total ion chromatogram,accounting for 99. 573% and 97. 187% of the total peak area,respectively. Main components of flowers and leaves of T. mongolicus include phenols and terpenes,and thymol accounts for 35. 38% and 49. 13% of flowers and leaves of T. mongolicus,respectively. [Conclusions] SPME-GC/MS can be applied in analyzing volatile components of flowers and leaves of T. mongolicus,to provide basis for further development and utilization of T. mongolicus.展开更多
A new and simple microwave-assisted alkaline degradation (MAAD) method for the elimination of organoehlorine-pesticide interference on the determination of polychlorinated biphenyls (PCBs) in soil by GC is present...A new and simple microwave-assisted alkaline degradation (MAAD) method for the elimination of organoehlorine-pesticide interference on the determination of polychlorinated biphenyls (PCBs) in soil by GC is presented. Under the optimal conditions, the interference of α- HCH, β- HCH, γ -HCH,δ -HCH, o. p' - DDT, p. p' - DDD and p. p' - DDT could be eliminated completely, and p. p' - DDE, Aldrin and Dieldrin could be partially eliminated; however, Dieldrin could be completely eliminated by using concentrated sulphurie acid. The method was evaluated by analyzing the spiked-soil sample. The mean recovery obtained was 84. 1% and the Relative Standard Deviation (RSD) was 2. 7%. Experimental results also indicate that the degradation of the interference and the extraction of the target analytes, PCBs, could be carried out simuhaneously. Compared with the traditional methods, the MAAD method is a rapid, efficient and solvent-saving method,展开更多
This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,t...This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,this paper draws a conclusion that IR has several advantages,including rapid analysis,excellent repeatability and low analysis cost.展开更多
文摘A method was developed for determination of 7 indictors the polychlorinated biphenyls (PCBs) residues in porphyra by gas chromatography (GC) with electron capture detector (ECD). The PCBs were extracted with hexane/methylene chloride (1:1, v/v) by ultrasonic extraction and the samples were cleaned up by concentrated sulfuric acid and Alumina-N solid phase extraction cartridge. The analytes were quantified by an internal standard method. Under optimal experimental conditions, good linearity was observed in the range of 5 - 200 ng/mL and the correlation coefficients were 0.9994 - 0.9998. The limit of quantitation (LOQ) for target analytes ranged from 6.0 to 10.0 μg/kg. At the spiked levels of 10, 50, 100 μg/kg, the average recoveries ranged from 90.9% to 102% with the relative standard deviations 2.12% - 6.32%. The result showed that the proposed method was rapid, and could be used for the determination of the PCBs in porphyra.
基金Project (No. 2006NG01) supported by the Agriculture Breakthrough Program of Yunnan Province, China
文摘Simple procedures for extraction and chromatographic determination of dimethachlon residues in fresh tobacco leaves and cut-tobacco are described.The determination was carried out by capillary gas chromatography(GC) with electron capture detection(ECD) and confirmed by GC-MS.The mean recoveries and relative standard deviation(RSD) were 93.2%~112.9% and 3.5%~6.7%,respectively at levels ranging from 0.01 to 0.1 mg/kg.The limit of determination was 0.001 mg/kg.Tobacco samples in routine check were successfully analyzed using the proposed method.
文摘Acrylates have been widely used in the synthesis of pharmaceutical polymers. The quantitation of residual acrylate monomers is vital as they are strong irritants and allergens, but after polymerization, are relatively inert, causing no irritation and allergies. Poly(ethylene oxide)(PEO) hydrogels were prepared using pentaerythritol tetra-acrylate(PETRA) as UV crosslinking agent. A simple, accurate, and robust quantitation method was developed based on gas chromatographic techniques(GC), which is suitable for routine analysis of residual PETRA monomers in these hydrogels. Unreacted PETRA was initially identified using gas chromatography–mass spectrometry(GC–MS). The quantitation of analyte was performed and validated using gas chromatography equipped with a flame ionization detector(GC–FID). A linear relationship was obtained over the range of 0.0002%–0.0450%(m/m) with a correlation coefficient(r2)greater than 0.99. The recovery( 4 90%), intra-day precision(%RSD o 0.67), inter-day precision(%RSD o2.5%), and robustness(%RSD o1.62%) of the method were within the acceptable values. The limit of detection(LOD) and limit of quantitation(LOQ) were 0.0001%(m/m) and 0.0002%(m/m), respectively.This assay provides a simple and quick way of screening for residual acrylate monomer in hydrogels.
基金Project supported by the National Natural Science Foundation of China (Grant No.21007038)
文摘Gas chromatography (GC) analysis of sulfer dioxide is challenging because SO2 is a highly mobile and chemically active molecule. For the conventional GC method with flame photometric detector (FPD) and direct-injection, it is often ineffective particularly when the SO2 level is as low as on the trace level. In this paper, a modified GC system integrated with an adsorption-desorption device was developed to detect the trace SO2 impurity in H2 fuel. Adsorbent GDX-502 is used in the adsorber to adsorb/collect SO2 from the sample gas and desorb/release it in a concentrated flow so that the conventional GC at downstream could detect it with an acceptable accuracy.
基金Supported by Sub-project of the "Eleventh Five-Year" National Science and Technology Support Program (2006BAD19B04)~~
文摘[Objective] This study aimed to analyze the chemical composition and yield of essential oil and n-hexane extract from moso bamboo to find active compounds with potential value. [Method] Essential oil and n-hexane extract were respectively extracted from moso bamboo of four different ages by using hydrodistillation and ultrasonic-assisted extraction with n-hexane, and analyzed with gas chromatography/mass spectrometry (GC/MS). [Result] The results show that cedrol (46.39%) is the first principal volatile component in essential oil of the middle stem of 7-year old moso bamboo; dibutyl phthalate (59.46%) is the first principal volatile component in n-hexane extract of the middle stem of 3-year old moso bamboo; yield of n-hexane extract is higher than that of essential oil from moso bamboo. [Conclusion] Cedrol is an active compound with potential value.
基金funded by the National Natural Science Foundation of China(Grant No.41172126)the State Key Laboratory of Petroleum Resources and Prospecting(PRP/indep-2-1402)
文摘Heavy biodegraded crude oils have larger numbers of coeluting compounds than nonbiodegraded oils, and they are typically not resolved with conventional gas chromatography(GC). This unresolved complex mixture(UCM) has been investigated using comprehensive two-dimensional gas chromatography–time-of-flight mass spectrometry(GC×GC-To FMS) within a set of biodegraded petroleums derived from distinct sedimentary basins, including northwestern Sichuan(Neoproterozoic, marine), Tarim(Early Paleozoic, marine), Bohai Bay(Eocene, saline/brackish) and Pearl River Mouth(Eocene, freshwater). In general, the hydrocarbons that constitute the UCM in petroleum saturate fractions can be classified into three catalogues based on the distributions of resolved compounds on two dimensional chromatograms. Group 1 is composed mainly of normal and branched alkanes, isoprenoid alkanes and monocyclic alkanes; Group 2 comprises primarily terpanes ranging from two to five rings, and Group 3 is dominated by monoaromatic hydrocarbons such as tetralins and monoaromatic steranes. In addition, the UCM is source dependent and varies between oil populations. i.e., the UCM of petroleum derived from Precambrian and Early Paleozoic marine, Eocene saline/brackish and freshwater source rocks is specifically rich in higher homologues of A-norsteranes, series of 1,1,3-trimethyl-2-alkylcyclohexanes(carotenoid-derived alkanes), and tetralin and indane compounds, respectively.
文摘The solid-phase microextraction (SPME) combined with gas chromatography/mass spectrometry (GC/MS) was used to determine and analyze organic pollutants in coking wastewater. Based on the fact that the main compounds in the wastewater were organics, some key parameters of the SPME were optimized. The method has good linearity ( its correlation coefficients 〉 0.99) in the range determined,its relative standard deviations (RSD) are less than 15%, and its recovery is from 87.9% to 128.1% with the lowest quantification limit of 5 ~g/L. This method has been used to measure 15 organic pollutants in wastewater from a certain coking plant. The results show that compared with the conventional method,it can save an hour in pretreatment time. It is a fast, low-cost, accurate, simple and efficient analytical method indeed.
基金Supported by Natural Science Foundation Project of Inner Mongolia Autonomous Region(2015MS0324)Scientific Research Service Project of Chifeng University(KYFW-16-05)
文摘[Objectives] To analyze volatile components of flowers and leaves of Thymus mongolicus. [Methods]Volatile components of collected T. mongolicus flower and leaves were separated by headspace solid-phase microextraction( SPME) and identified by gas chromatography/mass spectrometry( GC/MS) and normallized by peak area. [Results] A total of 24 and 14 compounds were identified from flowers and leaves of T. mongolicus in the total ion chromatogram,accounting for 99. 573% and 97. 187% of the total peak area,respectively. Main components of flowers and leaves of T. mongolicus include phenols and terpenes,and thymol accounts for 35. 38% and 49. 13% of flowers and leaves of T. mongolicus,respectively. [Conclusions] SPME-GC/MS can be applied in analyzing volatile components of flowers and leaves of T. mongolicus,to provide basis for further development and utilization of T. mongolicus.
基金Sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholar State Education Ministry (Grant No.415409) and the Scien-tific Research Foundation for Doctors, Guangdong Natural Science Foundation (Grant No.974078).
文摘A new and simple microwave-assisted alkaline degradation (MAAD) method for the elimination of organoehlorine-pesticide interference on the determination of polychlorinated biphenyls (PCBs) in soil by GC is presented. Under the optimal conditions, the interference of α- HCH, β- HCH, γ -HCH,δ -HCH, o. p' - DDT, p. p' - DDD and p. p' - DDT could be eliminated completely, and p. p' - DDE, Aldrin and Dieldrin could be partially eliminated; however, Dieldrin could be completely eliminated by using concentrated sulphurie acid. The method was evaluated by analyzing the spiked-soil sample. The mean recovery obtained was 84. 1% and the Relative Standard Deviation (RSD) was 2. 7%. Experimental results also indicate that the degradation of the interference and the extraction of the target analytes, PCBs, could be carried out simuhaneously. Compared with the traditional methods, the MAAD method is a rapid, efficient and solvent-saving method,
文摘This paper aims at testing oxygen and benzene contents in gasoline by mid-infrared spectroscopy.The experimental results prove that infrared spectroscopy(IR)is reliable.Compared with gas chromatography(GC)technology,this paper draws a conclusion that IR has several advantages,including rapid analysis,excellent repeatability and low analysis cost.