To compensate for the shortcomings of quasi-static law in anti-fatigue analysis of foundry crane metal structures,the fatigue life evaluation method of foundry crane metal structure considering load dynamic response a...To compensate for the shortcomings of quasi-static law in anti-fatigue analysis of foundry crane metal structures,the fatigue life evaluation method of foundry crane metal structure considering load dynamic response and crack closure effect is proposed.In line with the theory of mechanical vibration,a dynamic model of crane structure during the working cycle is constructed,and dynamic coefficients under diverse actions are analysed.Calculation models of the internal force dynamic change process of dangerous cross-sections and a simulation model of first principal stress-time history are established by using the steel structure design criteria,which is utilised to extract the change of first principal stress of danger points over time.Then,the double-parameter stress spectrum is obtained by the rain flow counting method.The fatigue life calculation formula is corrected by introducing a crack closure parameter that can be calculated by the stress ratio and the effective stress ratio.Under the finite element model imported into Msc.Patran,crack propagation analysis is performed by the growth method in the fatigue integration module Msc.Fatigue.Taking the metal structure of a 100/40t-28.5m foundry crane with track offset as an example,the accuracy of calculation results and the feasibility and applicability of the proposed method are verified by theoretical calculation and finite element simulation,which provide a theoretical basis for improvement of the fatigue resistance design of foundry cranes.展开更多
The fatigue crack growth rate (CGR) of ultra high strength steel 30CrMnSiNi2A in distilled water at 18,35 and 55℃ were measured.It was confirmed that the temperature is strongly af- fected on the corrosion fatigue CG...The fatigue crack growth rate (CGR) of ultra high strength steel 30CrMnSiNi2A in distilled water at 18,35 and 55℃ were measured.It was confirmed that the temperature is strongly af- fected on the corrosion fatigue CGR of ultra high strength steel.An expression concerning the effects of Δ K and temperature on the CGR was proposed.The fact that the apparent activation energy (36.6 kJ/mol) resulted from regressive analysis of CGR data was similar to the activation energy of hydrogen diffusion in γ-Fe,strongly supporting the theory of hydrogen-assisted crack growth.The overload retardation effect was greatly reduced in cor- rosion fatigue crack growth,especially at lower frequency,e.g.,0.1 Hz.This phenomenon might be due to the increase of the SCC component of CGR after an overload.展开更多
A comparative study is performed between a crack closure model and the Willenborg model, which can calculate the fatigue crack growth rate under the overload effects. The modified virtual crack annealing(VCA) model is...A comparative study is performed between a crack closure model and the Willenborg model, which can calculate the fatigue crack growth rate under the overload effects. The modified virtual crack annealing(VCA) model is briefly reviewed, which is based on the equivalent plastic zone concept. In this method, the retardation phenomenon is explained by the crack closure level variation, which is derived from the interactions between forward and reverse plastic zones ahead of the crack tip. As a comparison, the Forman equation in conjunction with the Willenborg model is also reviewed. The retardation phenomenon is described by directly modifying the stress intensity factor. It is known that the large plastic zone created by the overload can decelerate the fatigue crack growth rate until the crack grows beyond this region. A relationship between the plastic zone and the modified stress intensity factor is developed, which is a mathematical fitting equation instead of physical-based formulation. The experimental data in aluminum alloys are used to validate these two models. Overall, good agreement is observed between the model predictions and the testing data. It is noted that the approach based on modified VCA model can give more accurate prediction curves than the Willenborg model.展开更多
基金the National Science-technology Support Projects for the 13th Five-year Plan(2017YFC0805703-4).
文摘To compensate for the shortcomings of quasi-static law in anti-fatigue analysis of foundry crane metal structures,the fatigue life evaluation method of foundry crane metal structure considering load dynamic response and crack closure effect is proposed.In line with the theory of mechanical vibration,a dynamic model of crane structure during the working cycle is constructed,and dynamic coefficients under diverse actions are analysed.Calculation models of the internal force dynamic change process of dangerous cross-sections and a simulation model of first principal stress-time history are established by using the steel structure design criteria,which is utilised to extract the change of first principal stress of danger points over time.Then,the double-parameter stress spectrum is obtained by the rain flow counting method.The fatigue life calculation formula is corrected by introducing a crack closure parameter that can be calculated by the stress ratio and the effective stress ratio.Under the finite element model imported into Msc.Patran,crack propagation analysis is performed by the growth method in the fatigue integration module Msc.Fatigue.Taking the metal structure of a 100/40t-28.5m foundry crane with track offset as an example,the accuracy of calculation results and the feasibility and applicability of the proposed method are verified by theoretical calculation and finite element simulation,which provide a theoretical basis for improvement of the fatigue resistance design of foundry cranes.
文摘The fatigue crack growth rate (CGR) of ultra high strength steel 30CrMnSiNi2A in distilled water at 18,35 and 55℃ were measured.It was confirmed that the temperature is strongly af- fected on the corrosion fatigue CGR of ultra high strength steel.An expression concerning the effects of Δ K and temperature on the CGR was proposed.The fact that the apparent activation energy (36.6 kJ/mol) resulted from regressive analysis of CGR data was similar to the activation energy of hydrogen diffusion in γ-Fe,strongly supporting the theory of hydrogen-assisted crack growth.The overload retardation effect was greatly reduced in cor- rosion fatigue crack growth,especially at lower frequency,e.g.,0.1 Hz.This phenomenon might be due to the increase of the SCC component of CGR after an overload.
基金financially supported by the National Natural Science Foundation of China (No. 51405009)the Fundamental Research Funds for the Central Universities of China
文摘A comparative study is performed between a crack closure model and the Willenborg model, which can calculate the fatigue crack growth rate under the overload effects. The modified virtual crack annealing(VCA) model is briefly reviewed, which is based on the equivalent plastic zone concept. In this method, the retardation phenomenon is explained by the crack closure level variation, which is derived from the interactions between forward and reverse plastic zones ahead of the crack tip. As a comparison, the Forman equation in conjunction with the Willenborg model is also reviewed. The retardation phenomenon is described by directly modifying the stress intensity factor. It is known that the large plastic zone created by the overload can decelerate the fatigue crack growth rate until the crack grows beyond this region. A relationship between the plastic zone and the modified stress intensity factor is developed, which is a mathematical fitting equation instead of physical-based formulation. The experimental data in aluminum alloys are used to validate these two models. Overall, good agreement is observed between the model predictions and the testing data. It is noted that the approach based on modified VCA model can give more accurate prediction curves than the Willenborg model.