Fault diagnosis and fault-tolerant control of photovoltaic micro-inverter 被引量:1
1
作者 李舟 彭涛 +2 位作者 张鹏飞 韩华 杨建 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2284-2295,共12页
An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topo... An observer-based fault diagnosis method and a fault tolerant control for open-switch fault and current sensor fault are proposed for interleaved flyback converters of a micro-inverter system. First, based on the topology of a grid-connected micro-inverter, a mathematical model of the flyback converters is established. Second, a state observer is applied to estimate the currents online and generate corresponding residuals. The fault is diagnosed by comparing the residuals with the thresholds. Finally, a fault-tolerant control that consists of a fault-tolerant topology for the faulty switch and a simple software redundancy control for the faulty current sensor, is proposed to achieve a fault-tolerant operation. The feasibility and effectiveness of the proposed method has been verified by simulation and experimental results. 展开更多
关键词 故障诊断方法 容错控制 逆变器 电流传感器 状态观测器 光伏 开关故障 拓扑结构
下载PDF
Design and Analysis of Fault Diagnosis and Fault-tolerant Control for a Class of MIMO Nonlinear State Systems 被引量:2
2
作者 Sunan HUANG Kok Kiong TAN 《Instrumentation》 2019年第4期14-25,共12页
This paper presents a fault diagnosis and fault-tolerant control algorithm,which can be used for a class of multi-input multi-output(MIMO)nonlinear state systems.First,a state estimator is proposed,which is able to de... This paper presents a fault diagnosis and fault-tolerant control algorithm,which can be used for a class of multi-input multi-output(MIMO)nonlinear state systems.First,a state estimator is proposed,which is able to detect fault occurrence,by using a residual signal.Second,when the state is at an abnormal condition,the fault-tolerant control will be triggered to minimize the impact of the fault occurrence.This fault-tolerant control is designed by using a robust controller(original controller),and an on-line approximator to capture a nonlinear function that indicates the fault occurrence.The detailed analysis is given for the proposed fault accommodation control. 展开更多
关键词 fault diagnosis fault Detection Nonlinear Observer On-line Approximator fault-tolerant control
下载PDF
A finite-time fuzzy adaptive output-feedback fault-tolerant control for underactuated wheeled mobile robots systems
3
作者 Pingfan Liu Shaocheng Tong 《Journal of Automation and Intelligence》 2024年第2期111-118,共8页
This paper investigates the adaptive fuzzy finite-time output-feedback fault-tolerant control (FTC) problemfor a class of nonlinear underactuated wheeled mobile robots (UWMRs) system with intermittent actuatorfaults. ... This paper investigates the adaptive fuzzy finite-time output-feedback fault-tolerant control (FTC) problemfor a class of nonlinear underactuated wheeled mobile robots (UWMRs) system with intermittent actuatorfaults. The UWMR system includes unknown nonlinear dynamics and immeasurable states. Fuzzy logic systems(FLSs) are utilized to work out immeasurable functions. Furthermore, with the support of the backsteppingcontrol technique and adaptive fuzzy state observer, a fuzzy adaptive finite-time output-feedback FTC scheme isdeveloped under the intermittent actuator faults. It is testifying the scheme can ensure the controlled nonlinearUWMRs is stable and the estimation errors are convergent. Finally, the comparison results and simulationvalidate the effectiveness of the proposed fuzzy adaptive finite-time FTC approach. 展开更多
关键词 Underactuated wheeled mobile robots system FINITE-TIME Fuzzy adaptive fault-tolerant control OUTPUT-FEEDBACK Intermittent actuator faults
下载PDF
Rule-based Fault Diagnosis of Hall Sensors and Fault-tolerant Control of PMSM 被引量:12
4
作者 SONG Ziyou LI Jianqiu +3 位作者 OUYANG Minggao GU Jing FENG Xuning LU Dongbin 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2013年第4期813-822,共10页
Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor fault... Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor faults occur. But there is scarcely any research focusing on fault diagnosis and fault-tolerant control of Hall sensor used in PMSM. From this standpoint, the Hall sensor faults which may occur during the PMSM operating are theoretically analyzed. According to the analysis results, the fault diagnosis algorithm of Hall sensor, which is based on three rules, is proposed to classify the fault phenomena accurately. The rotor phase estimation algorithms, based on one or two Hall sensor(s), are initialized to engender the fault-tolerant control algorithm. The fault diagnosis algorithm can detect 60 Hall fault phenomena in total as well as all detections can be fulfilled in 1/138 rotor rotation period. The fault-tolerant control algorithm can achieve a smooth torque production which means the same control effect as normal control mode (with three Hall sensors). Finally, the PMSM bench test verifies the accuracy and rapidity of fault diagnosis and fault-tolerant control strategies. The fault diagnosis algorithm can detect all Hall sensor faults promptly and fault-tolerant control algorithm allows the PMSM to face failure conditions of one or two Hall sensor(s). In addition, the transitions between health-control and fault-tolerant control conditions are smooth without any additional noise and harshness. Proposed algorithms can deal with the Hall sensor faults of PMSM in real applications, and can be provided to realize the fault diagnosis and fault-tolerant control of PMSM. 展开更多
关键词 electric vehicle permanent-magnet synchronous motor(PMSM) Hall sensors rule-based fault diagnosis fault-tolerant control
下载PDF
Temperature fault-tolerant control system of CSTR with coil and jacket heat exchanger based on dual control and fault diagnosis 被引量:1
5
作者 王再英 王国鑫 《Journal of Central South University》 SCIE EI CAS CSCD 2017年第3期655-664,共10页
For the characteristics of the continuous stirred-tank reactor(CSTR) with coil and jacket cooling system,a CSTR temperature dual control solution based on the analysis of the CSTR exothermic reaction control character... For the characteristics of the continuous stirred-tank reactor(CSTR) with coil and jacket cooling system,a CSTR temperature dual control solution based on the analysis of the CSTR exothermic reaction control characteristic was proposed for an organic material polymerization production.The control solution has passive fault-tolerant ability for the jacket cooling water cutting off fault and active fault-tolerant potential for the coil cooling water cutting off fault,and it has good control ability,high saving energy and reducing consumption performance.Fault detection and diagnosis and fault-tolerant control strategy are designed for the coil cooling fault to achieve the active fault-tolerant control function.The CSTR temperature dual control,process fault detection and diagnosis and active fault-tolerant control were full integrated into the CSTR temperature fault-tolerant control system,which achieve fault tolerance control of CSTR temperature for any severe malfunction of jacket cooling or coil cooling cutting off,and the security for CSTR exothermic reaction is improved.Finally,the effectiveness of this system was validated by semi-physical simulation experiment. 展开更多
关键词 容错控制系统 故障诊断 温度 连续搅拌釜式反应器 换热器 夹套式 CSTR 冷却系统
下载PDF
Fault Detection and Diagnosis of Pneumatic Control Valve Based on a Hybrid Deep Learning Model
6
作者 HAO Hongtao WANG Kai 《Instrumentation》 2023年第4期12-26,共15页
As the growing requirements for the stability and safety of process industries,the fault detection and diagnosis of pneumatic control valves have crucial practical significance.Many of the approaches were presented in... As the growing requirements for the stability and safety of process industries,the fault detection and diagnosis of pneumatic control valves have crucial practical significance.Many of the approaches were presented in the literature to diagnose faults through the comparison of residual sequences with thresholds.In this study,a novel hybrid neural network model has been developed to address the issue of pneumatic control valve fault diagnosis.First,the feature extractor automatically extracts in-depth features of the signals through multi-scale convolutional neural networks with different kernel sizes,which not only adequately explores the local distinguishable features,but also takes into account the global features.The extracted features are then fused by the feature fusion layer to reduce redundant features.Finally,the long short-term memory for fault identification and the dense layer for fault classification.Experimental results demonstrate that the average test accuracy is above 94%and 16 out of the 19 conditions can be successfully detected in the simulated actual industrial environment.The effectiveness and practicability of the proposed method have been verified through a comparative analysis with existing intelligent fault diagnosis methods,and the results suggest that the developed model has better robustness. 展开更多
关键词 Pneumatic control Valve Feature Fusion fault diagnosis Convolutional Neural Network Long Short-term Memory
下载PDF
Digital Twin-Based Automated Fault Diagnosis in Industrial IoT Applications
7
作者 Samah Alshathri Ezz El-Din Hemdan +1 位作者 Walid El-Shafai Amged Sayed 《Computers, Materials & Continua》 SCIE EI 2023年第4期183-196,共14页
In recent years, Digital Twin (DT) has gained significant interestfrom academia and industry due to the advanced in information technology,communication systems, Artificial Intelligence (AI), Cloud Computing (CC),and ... In recent years, Digital Twin (DT) has gained significant interestfrom academia and industry due to the advanced in information technology,communication systems, Artificial Intelligence (AI), Cloud Computing (CC),and Industrial Internet of Things (IIoT). The main concept of the DT isto provide a comprehensive tangible, and operational explanation of anyelement, asset, or system. However, it is an extremely dynamic taxonomydeveloping in complexity during the life cycle that produces a massive amountof engendered data and information. Likewise, with the development of AI,digital twins can be redefined and could be a crucial approach to aid theInternet of Things (IoT)-based DT applications for transferring the data andvalue onto the Internet with better decision-making. Therefore, this paperintroduces an efficient DT-based fault diagnosis model based on machinelearning (ML) tools. In this framework, the DT model of the machine isconstructed by creating the simulation model. In the proposed framework,the Genetic algorithm (GA) is used for the optimization task to improvethe classification accuracy. Furthermore, we evaluate the proposed faultdiagnosis framework using performance metrics such as precision, accuracy,F-measure, and recall. The proposed framework is comprehensively examinedusing the triplex pump fault diagnosis. The experimental results demonstratedthat the hybrid GA-ML method gives outstanding results compared to MLmethods like LogisticRegression (LR), Na飗e Bayes (NB), and SupportVectorMachine (SVM). The suggested framework achieves the highest accuracyof 95% for the employed hybrid GA-SVM. The proposed framework willeffectively help industrial operators make an appropriate decision concerningthe fault analysis for IIoT applications in the context of Industry 4.0. 展开更多
关键词 Automated fault diagnosis control system ML AI CC IIoT digital twins genetic algorithm GA-ML technique
下载PDF
Backstepping-based active fault-tolerant control for a class of uncertain SISO nonlinear systems 被引量:6
8
作者 Meng Lingya Jiang Bin 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2009年第6期1263-1270,共8页
Active fault-tolerant control is investigated for a class of uncertain SISO nonlinear flight control systems based on the adaptive observer, feedback linearization and backstepping theory.Firstly an adaptive observer ... Active fault-tolerant control is investigated for a class of uncertain SISO nonlinear flight control systems based on the adaptive observer, feedback linearization and backstepping theory.Firstly an adaptive observer is constructed to estimate the fault in the faulty system.A new fault updating law is presented to simplify the assumption conditions of the adaptive observer.The asymptotical stability of the observer and the uniform ultimate boundedness of the fault estimation error are guaranteed by Lyapunov theorem.Then a backstepping-based active fault-tolerant controller is designed for the faulty system.The asymptotical stability of the closed-loop system and uniform ultimate boundedness of the tracking error are proved based on Lyapunov theorem.The effectiveness of the proposed scheme is demonstrated through the numerical simulation of a flight control system. 展开更多
关键词 fault-tolerant control fault diagnosis NONLINEAR BACKSTEPPING adaptive observer flight control.
下载PDF
Novel robust fault diagnosis method for flight control systems 被引量:10
9
作者 Guo Yuying Jiang Bin +1 位作者 Zhang Youmin Wang dianfei 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第5期1017-1023,共7页
A novel robust fault diagnosis scheme, which possesses fault estimate capability as well as fault diagnosis property, is proposed. The scheme is developed based on a suitable combination of the adaptive multiple model... A novel robust fault diagnosis scheme, which possesses fault estimate capability as well as fault diagnosis property, is proposed. The scheme is developed based on a suitable combination of the adaptive multiple model (AMM) and unknown input observer (UIO). The main idea of the proposed scheme stems from the fact that the actuator Lock-in-Place fault is unknown (when and where the actuator gets locked are unknown), and multiple models are used to describe different fault scenarios, then a bank of unknown input observers are designed to implement the disturbance de-coupling. According to Lyapunov theory, proof of the robustness of the newly developed scheme in the presence of faults and disturbances is derived. Numerical simulation results on an aircraft example show satisfactory performance of the proposed algorithm. 展开更多
关键词 fault diagnosis adaptive multiple model unknown input observer flight control.
下载PDF
Output feedback based adaptive robust fault-tolerant control for a class of uncertain nonlinear systems 被引量:6
10
作者 Shreekant Gayaka Bin Yao 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2011年第1期38-51,共14页
An adaptive robust approach for actuator fault-tolerant control of a class of uncertain nonlinear systems is proposed.The two chief ways in which the system performance can degrade following an actuator-fault are unde... An adaptive robust approach for actuator fault-tolerant control of a class of uncertain nonlinear systems is proposed.The two chief ways in which the system performance can degrade following an actuator-fault are undesirable transients and unacceptably large steady-state tracking errors.Adaptive control based schemes can achieve good final tracking accuracy in spite of change in system parameters following an actuator fault,and robust control based designs can achieve guaranteed transient response.However,neither adaptive control nor robust control based fault-tolerant designs can address both the issues associated with actuator faults.In the present work,an adaptive robust fault-tolerant control scheme is claimed to solve both the problems,as it seamlessly integrates adaptive and robust control design techniques.Comparative simulation studies are performed using a nonlinear hypersonic aircraft model to show the effectiveness of the proposed scheme over a robust adaptive control based faulttolerant scheme. 展开更多
关键词 fault-tolerant system actuator fault adaptive control robust control.
下载PDF
Kalman filter based fault diagnosis of networked control system with white noise 被引量:5
11
作者 YanweiWANG YingZHENG 《控制理论与应用(英文版)》 EI 2005年第1期55-59,共5页
The networked control system NCS is regarded as a sampled control system withoutput time-variant delay. White noise is considered in the model construction of NCS. By using theKalman filter theory to compute the filte... The networked control system NCS is regarded as a sampled control system withoutput time-variant delay. White noise is considered in the model construction of NCS. By using theKalman filter theory to compute the filter parameters, a Kalman filter is constructed for this NCS.By comparing the output of the filter and the practical system, a residual is generated to diagnoseme sensor faults and the actuator faults. Finally, an example is given to show the feasibility ofthe approach. 展开更多
关键词 networked control system fault diagnosis kalman filter
下载PDF
Adaptive fault-tolerant control based on boundary estimation for space robot under joint actuator faults and uncertain parameters 被引量:4
12
作者 Rong-Hua Lei Li Chen 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2019年第6期964-971,共8页
Since the joint actuator of the space robot executes the control instructions frequently in the harsh space environment,it is prone to the partial loss of control effectiveness(PLCE)fault.An adaptive fault-tolerant co... Since the joint actuator of the space robot executes the control instructions frequently in the harsh space environment,it is prone to the partial loss of control effectiveness(PLCE)fault.An adaptive fault-tolerant control algorithm is designed for a space robot system with the uncertain parameters and the PLCE actuator faults.The mathematical model of the system is established based on the Lagrange method,and the PLCE actuator fault is described as an effectiveness factor.The lower bound of the effectiveness factors and the upper bound of the uncertain parameters are estimated by an adaptive strategy,and the estimated value is fed back to the control algorithm.Compared with the traditional fault-tolerant algorithms,the proposed algorithm does not need to predetermine the lower bound of the effectiveness factor,hence it is more in line with the actual engineering application.It is proved that the algorithm can guarantee the stability of the closed-loop system based on the Lyapunov function method.The numerical simulation results show that the proposed algorithm can not only compensate for the uncertain parameters,but also can tolerate the PLCE actuator faults effectively,which verifies the effectiveness and superiority of the control scheme. 展开更多
关键词 Space robot Actuator faults Uncertain parameters Effectiveness factor fault-tolerant control
下载PDF
PID-type fault-tolerant prescribed performance control of fixed-wing UAV 被引量:5
13
作者 YU Ziquan ZHANG Youmin JIANG Bin 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第5期1053-1061,共9页
This paper introduces a fault-tolerant control(FTC)design for a faulty fixed-wing unmanned aerial vehicle(UAV).To constrain tracking errors against actuator faults,error constraint inequalities are first transformed t... This paper introduces a fault-tolerant control(FTC)design for a faulty fixed-wing unmanned aerial vehicle(UAV).To constrain tracking errors against actuator faults,error constraint inequalities are first transformed to a new set of variables based on prescribed performance functions.Then,the commonly used and powerful proportional-integral-derivative(PID)control concept is employed to filter the transformed error variables.To handle the fault-induced nonlinear terms,a composite learning algorithm consisting of neural network and disturbance observer is incorporated for increasing flight safety.It is shown by Lyapunov stability analysis that the tracking errors are strictly constrained within the specified error bounds.Experimental results are presented to verify the feasibility of the developed FTC scheme. 展开更多
关键词 unmanned aerial vehicle(UAV) fault-tolerant control(FTC) prescribed performance control(PPC) proportional-integral-derivative(PID) composite learning actuator faults
下载PDF
Design and simulation of fault diagnosis based on NUIO/LMI for satellite attitude control systems 被引量:2
14
作者 Yuehua Cheng Qian Hou Bin Jiang 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2012年第4期581-587,共7页
This paper presents a scheme of fault diagnosis for flexible satellites during orbit maneuver. The main contribution of the paper is related to the design of the nonlinear input observer which can avoid false alarm ar... This paper presents a scheme of fault diagnosis for flexible satellites during orbit maneuver. The main contribution of the paper is related to the design of the nonlinear input observer which can avoid false alarm arising from the disturbance from orbit control force. The effects of orbit control force on the fault diagnosis system for satellite attitude control systems, including the disturbing torque caused by the misalignments and the model uncertainty caused by the fuel consumed, are discussed, where standard Lu- enberger observer cannot work well. Then the nonlinear unknown input observer is proposed to decouple faults from disturbance, Besides, a linear matrix inequality approach is adopted to reduce the effect of nonlinear part and model uncertainties on the observer. The numerical and semi-physical simulation demonstrates the effectiveness of the proposed observer for the fault diagnosis system of the satellite during orbit maneuver. 展开更多
关键词 orbit control flexible satellite attitude control system nonlinear unknown input observer (NUIO) fault diagnosis.
下载PDF
Data Driven Fault Diagnosis and Fault Tolerant Control: Some Advances and Possible New Directions 被引量:44
15
作者 WANG Hong CHAI Tian-You +1 位作者 DING Jin-Liang BROWN Martin 《自动化学报》 EI CSCD 北大核心 2009年第6期739-747,共9页
关键词 自动化系统 数据分析 容错控制 故障诊断系统
下载PDF
Research on Remote Monitoring and Fault Diagnosis Technology of Numerical Control Machine 被引量:1
16
作者 ZHANG Jianyu~1 GAO Lixin~1 CUI Lingli~1 LI Xianghui~2 WANG Yingwang~2 1.Key Laboratory.of Advanced Manufacturing Technology,Beijing University of Technology,Beijing 100022,China 2.Tangshan Iron and Steel Corp.LTD,Tangshan 063000,China 《武汉理工大学学报》 CAS CSCD 北大核心 2006年第S2期748-752,共5页
Based on the internet technology,it has become possible to complete remote monitoring and fault diagnosis for the numerical control machine.In order to capture the micro-shock signal induced by the incipient fault on ... Based on the internet technology,it has become possible to complete remote monitoring and fault diagnosis for the numerical control machine.In order to capture the micro-shock signal induced by the incipient fault on the rotating parts,the reso- nance demodulation technology is utilized in the system.As a subsystem of the remote monitoring system,the embedded data acquisi- tion instrument not only integrates the demodulation board but also complete the collection and preprocess of monitoring data from different machines.Furthermore,through connecting to the internet,the data can be transferred to the remote diagnosis center and data reading and writing function can be finished in the database.At the same time,the problem of the IP address floating in the dial-up of web server is solved by the dynamic DNS technology.Finally,the remote diagnosis software developed on the Lab VIEW platform can analyze the monitoring data from manufacturing field.The research results have indicated that the equipment status can be monitored by the system effectively. 展开更多
关键词 NUMERICAL control MACHINE RESONANCE DEMODULATION REMOTE monitoring fault diagnosis
下载PDF
Robust and Active Fault-tolerant Control for a Class of Nonlinear Uncertain Systems 被引量:1
17
作者 You-Qing Wang Dong-Hua Zhou Li-Heng Liu 《International Journal of Automation and computing》 EI 2006年第3期309-313,共5页
A novel integrated design strategy for robust fault diagnosis and fault-tolerant control (FTC) of a class of nonlinear uncertain systems is proposed. The uncertainties considered in this paper are more general than ... A novel integrated design strategy for robust fault diagnosis and fault-tolerant control (FTC) of a class of nonlinear uncertain systems is proposed. The uncertainties considered in this paper are more general than those in other existing works, and faults are described in a new formulation. It is proven that the states of a closed-loop system converge asymptotically to zero even if there are uncertainties and faults in a system. Simulation results on a simple pendulum are presented for illustration. 展开更多
关键词 NONLINEAR UNCERTAINTY fault diagnosis fault-tolerant control (FTC).
下载PDF
A fault-tolerant control method for distributed flight control system facing wing damage 被引量:1
18
作者 CUI Yuwei LI Aijun MENG Xianfeng 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2021年第5期1041-1052,共12页
With the strong battlefield application environment of the next generation fighter,based on the design of distributed vehicle management system,a fault diagnosis and fault-tolerant control(FTC)method for wing surface ... With the strong battlefield application environment of the next generation fighter,based on the design of distributed vehicle management system,a fault diagnosis and fault-tolerant control(FTC)method for wing surface damage is proposed in this paper.Aiming at three kinds of wing damage modes,this paper proposes a diagnosis method based on the fault decision tree and forms a fault decision tree for wing damage from the aspects of sample database construction,feature parameter extraction,and fault decision tree construction.Based on the fault diagnosis results,the longitudinal control law based on dynamic inverse and the lateral-directional robust control laws based on linear quadratic regulator(LQR)are proposed.From the simulation examples,the fault diagnosis algorithm based on the decision tree can complete the judgment of three wing surface damage modes within 2 ms,and the FTC law can make the fighter quickly return to a stable flight state after a short transient of 1 s,which achieves the fault-tolerant goal. 展开更多
关键词 flight control fault diagnosis distributed system dynamic inverse linear quadratic regulator(LQR)
下载PDF
Fault-tolerant Control of Nonlinear System Using Credit Assign Fuzzy CMAC 被引量:8
19
作者 ZHU Da-Qi KONG Min 《自动化学报》 EI CSCD 北大核心 2006年第3期329-336,共8页
The adaptive fault-tolerant control scheme of dynamic nonlinear system based on the credit assigned fuzzy CMAC neural network is presented. The proposed learning approach uses the learned times of addressed hypercubes... The adaptive fault-tolerant control scheme of dynamic nonlinear system based on the credit assigned fuzzy CMAC neural network is presented. The proposed learning approach uses the learned times of addressed hypercubes as the credibility, the amounts of correcting errors are proportional to the inversion of the learned times of addressed hypercubes. With this idea, the learning speed can indeed be improved. Based on the improved CMAC learning approach and using the sliding control technique, the effective control law reconfiguration strategy is presented. The system stability and performance are analyzed under failure scenarios. The numerical simulation demonstrates the effectiveness of the improved CMAC algorithm and the proposed fault-tolerant controller. 展开更多
关键词 故障诊断 容错控制 模糊控制 CMAC
下载PDF
Remedial Phase-Angle Control of a Five-Phase Fault-Tolerant Permanent- Magnet Vernier Machine With Short-Circuit Fault 被引量:2
20
作者 Wenxiang Zhao Chenyu Gu +2 位作者 Qian Chen Jinghua Ji Dezhi Xu 《CES Transactions on Electrical Machines and Systems》 2017年第1期83-88,共6页
A fault-tolerant permanent-magnet vernier(FT-PMV)machine incorporates the merits of high fault-tolerant capability and high torque density.In this paper,a remedial phase-angle control(RPAC)strategy is proposed for a f... A fault-tolerant permanent-magnet vernier(FT-PMV)machine incorporates the merits of high fault-tolerant capability and high torque density.In this paper,a remedial phase-angle control(RPAC)strategy is proposed for a five-phase FT-PMV machine with short-circuit fault.Firstly,the proposed strategy can reduce the amount of unknown quantities by structuring the phase-angles of the normal phases.It can simplify the calculation of the remedial currents.Then,in order to obtain the desired torque,only the amplitudes of the remedial currents need to be calculated.Based on the principle of instantaneous electrical input power and mechanical output power balance condition,the real components are used to maintain the torque capability,while the reactive components are limited zero to minimize the torque ripple.Both simulations and experiments are presented to verify the proposed RPAC strategy. 展开更多
关键词 fault-tolerant permanent-magnet vernier(FT-PMV)machine remedial phase-angle control(RPAC) short-circuit fault.