期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Quaternary tectonic control on channel morphology over sedimentary low land:A case study in the Ajay-Damodar interfluve of Eastern India 被引量:3
1
作者 Suvendu Roy Abhay Sankar Sahu 《Geoscience Frontiers》 SCIE CAS CSCD 2015年第6期927-946,共20页
The style of active tectonic on the deformation and characterization of fluvial landscape has been investigated on three typical skrike-slip fault zones of the Ajay-Damodar Interfluve(ADI) in Eastern India through f... The style of active tectonic on the deformation and characterization of fluvial landscape has been investigated on three typical skrike-slip fault zones of the Ajay-Damodar Interfluve(ADI) in Eastern India through field mapping,structural analysis and examination of digital topography(ASTER-30 m),multispectral imageries,and Google Earth images,Channel morphology in Quaternary sediment is more deformed than Cenozoic lateritic tract and igneous rock system by the neotectonic activities,The structural and lithological controls on the river system in ADI region are reflected by distinct drainage patterns,abrupt change in flow direction,offset river channels,straight river lines,ponded river channel,marshy lands,sag ponds,palaeo-channels,alluvial fans,meander cutoffs,multi-terrace river valley,incised compressed meander,convexity of channel bed slope and knick points in longitudinal profile,Seven morphotectonic indices have been used to infer the role of neotectonic on the modification of channel morphology,A tectonic index map for the ADI region has been prepared by the integration of used morphotectonic indices,which is also calibrated by Bouguer gravity anomaly data and field investigation. 展开更多
关键词 Active tectonic Skrike-slip fault Channel morphology Morphotectonic indices Neotectonic map
下载PDF
Augmentation of situational awareness by fault passage indicators in distribution network incorporating network reconfiguration 被引量:8
2
作者 Tanmay Jain Debomita Ghosh Dusmanta Kumar Mohanta 《Protection and Control of Modern Power Systems》 2019年第1期281-294,共14页
Power distribution systems are profoundly inclined to disturbances like untimely switching of breakers & relays, sympathetic tripping, and uncertainties regarding fault location. Thus, system stability and reliabi... Power distribution systems are profoundly inclined to disturbances like untimely switching of breakers & relays, sympathetic tripping, and uncertainties regarding fault location. Thus, system stability and reliability are greatly affected. In this way, situational awareness and system integrity are the crucial factors in developing power system security, as it empowers successful decision making & timely reaction by the operators to any disturbance and also maintaining continuity of power supply. This paper focuses on the enhancement of situational awareness by fault location through fault passage indicators (FPI) to improve nominal impedance-based methods in distribution networks. Also, the proposed method is validated by comparing it with Intelligent Electronic Device (IED) based fault location method. Further, simultaneous reconfiguration of the system is incorporated to maintain the continuity of supply. The analysis has been tested on IEEE 33 bus distribution system. 展开更多
关键词 Situational awareness fault passage Indicator Tie switching RECONFIGURATION
原文传递
Experimental investigation and comparative study of interturn short-circuits and unbalanced voltage supply in induction machines
3
作者 Fatima BABAA Abdelmalek KHEZZAR Mohamed el kamel OUMAAMAR 《Frontiers in Energy》 SCIE CSCD 2013年第3期271-278,共8页
A transient model for an induction machine with stator winding turn faults on a single phase is derived using reference frame transformation theory. The negative sequence component and the 3rd harmonic are often consi... A transient model for an induction machine with stator winding turn faults on a single phase is derived using reference frame transformation theory. The negative sequence component and the 3rd harmonic are often considered as accurate indicators. However, small unbalance in the supply voltage and/or in the machine structure that exists in any real system engenders the same harmonics components. In this case, it is too difficult to distinguish between the current harmonics due to the supply voltage and those originated by inter-turn short- circuit faults. For that, to have the correct diagnosis and to increase the sensitivity and the reliability of the diagnostic system, it is crucial to provide the relationship between the inter-turn short-circuits in the stator winding and the supply voltage imbalance through an accurate mathematical model and via a series of experimental essays. 展开更多
关键词 induction machines fault indicator inter-turn short-circuit fault unbalance supply voltage
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部