期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Semi-analytical solution for mechanical analysis of tunnels crossing strike-slip fault zone considering nonuniform fault displacement and uncertain fault plane position
1
作者 YANG Heng-hong WANG Ming-nian +1 位作者 YU Li ZHANG Xiao 《Journal of Central South University》 SCIE EI CAS CSCD 2024年第6期2116-2136,共21页
The tunnel subjected to strike-slip fault dislocation exhibits severe and catastrophic damage.The existing analysis models frequently assume uniform fault displacement and fixed fault plane position.In contrast,post-e... The tunnel subjected to strike-slip fault dislocation exhibits severe and catastrophic damage.The existing analysis models frequently assume uniform fault displacement and fixed fault plane position.In contrast,post-earthquake observations indicate that the displacement near the fault zone is typically nonuniform,and the fault plane position is uncertain.In this study,we first established a series of improved governing equations to analyze the mechanical response of tunnels under strike-slip fault dislocation.The proposed methodology incorporated key factors such as nonuniform fault displacement and uncertain fault plane position into the governing equations,thereby significantly enhancing the applicability range and accuracy of the model.In contrast to previous analytical models,the maximum computational error has decreased from 57.1%to 1.1%.Subsequently,we conducted a rigorous validation of the proposed methodology by undertaking a comparative analysis with a 3D finite element numerical model,and the results from both approaches exhibited a high degree of qualitative and quantitative agreement with a maximum error of 9.9%.Finally,the proposed methodology was utilized to perform a parametric analysis to explore the effects of various parameters,such as fault displacement,fault zone width,fault zone strength,the ratio of maximum fault displacement of the hanging wall to the footwall,and fault plane position,on the response of tunnels subjected to strike-slip fault dislocation.The findings indicate a progressive increase in the peak internal forces of the tunnel with the rise in fault displacement and fault zone strength.Conversely,an augmentation in fault zone width is found to contribute to a decrease in the peak internal forces.For example,for a fault zone width of 10 m,the peak values of bending moment,shear force,and axial force are approximately 46.9%,102.4%,and 28.7% higher,respectively,compared to those observed for a fault zone width of 50 m.Furthermore,the position of the peak internal forces is influenced by variations in the ratio of maximum fault displacement of the hanging wall to footwall and the fault plane location,while the peak values of shear force and axial force always align with the fault plane.The maximum peak internal forces are observed when the footwall exclusively bears the entirety of the fault displacement,corresponding to a ratio of 0:1.The peak values of bending moment,shear force,and axial force for the ratio of 0:1 amount to approximately 123.8%,148.6%,and 111.1% of those for the ratio of 0.5:0.5,respectively. 展开更多
关键词 strike-slip fault tunnel engineering semi-analytical solution fault zone width nonuniform fault displacement uncertain fault plane position
下载PDF
Model-Based Embedded Compiled Software Fault Positioning
2
作者 LIU Jinshuo CHEN Jian +2 位作者 ZHANG Weixin XU Xiangyang YAN Jingjing 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2017年第3期263-268,共6页
Software fault positioning is one of the most effective activities in program debugging. In this paper, we propose a model-based fault positioning method to detect the faults of embedded program without source code. T... Software fault positioning is one of the most effective activities in program debugging. In this paper, we propose a model-based fault positioning method to detect the faults of embedded program without source code. The system takes the machine code of embedded software as input and translates the code into high-level language C with the software reverse engineering program. Then, the static analysis on the high-level program is taken to obtain a control flow graph(CFG), which is denoted as a node-tree and each node is a basic block. According to the faults found by the field testing, we construct a fault model by extracting the features of the faulty code obtained by ranking the Ochiai coefficient of basic blocks. The model can be effectively used to locate the faults of the embedded program. Our method is evaluated on ST chips of the smart meter with the corresponding source code. The experiment shows that the proposed method has an effectiveness about 87% on the fault detection. 展开更多
关键词 code reverse engineering model-based test fault positioning
原文传递
Study on the distribution characteristics of faults and their control over petroliferous basins in the China seas and its adjacent areas 被引量:3
3
作者 Xin’gang Luo Wanyin Wang +5 位作者 Ying Chen Zhizhao Bai Dingding Wang Tao He Yimi Zhang Ruiyun Ma 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2023年第3期227-242,共16页
As one of the main controlling factors of oil and gas accumulation,faults are closely related to the distribution of oil and gas reservoirs.Studying how faults control petroliferous basins is particularly important.In... As one of the main controlling factors of oil and gas accumulation,faults are closely related to the distribution of oil and gas reservoirs.Studying how faults control petroliferous basins is particularly important.In this work,we investigated the plane positions of major faults in the China seas and its adjacent areas using the normalized vertical derivative of the total horizontal derivative(NVDR-THDR)of the Bouguer gravity anomaly,the fusion results of gravity and magnetic anomalies,and the residual Bouguer gravity anomaly.The apparent depths of major faults in the China seas and its adjacent areas were inverted using the Tilt-Euler method based on the Bouguer gravity anomaly.The results show that the strikes of the faults in the China seas and its adjacent areas are mainly NE and NW,followed by EW,and near-SN.Among them,the lengths of most ultra-crustal faults are in the range of 1000–3000 km,and their apparent depths lie between 10 km and 40 km.The lengths of crustal faults lie between 300 km and 1000 km,and their apparent depths are between 0 km and 20 km.According to the plane positions and apparent depths of the faults,we put forward the concept of fault influence factor for the first time.Based on this factor,the key areas for oil and gas exploration were found as follows:the east of South North China Basin in the intracontinental rift basins;the southeast region of East China Sea Shelf Basin,the Taixinan and Qiongdongnan basins in the continental margin rift basins;Zhongjiannan Basin in the strike-slip pull-apart basins;the Liyue,Beikang,and the Nanweixi basins in the rifted continental basins.This work provides valuable insights into oil and gas exploration,mineral resource exploration,and deep geological structure research in the China seas and its adjacent areas. 展开更多
关键词 China seas gravity and magnetic anomalies plane positions of faults apparent depths of faults oil and gas basins
下载PDF
Transmission cable fault detector based on waveform reconstruction
4
作者 吴剑锋 于忠洲 +2 位作者 李建清 王蕾 李小敏 《Journal of Southeast University(English Edition)》 EI CAS 2013年第1期48-51,共4页
In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable... In order to improve the accuracy of cable fault position location at a low cost and make the testing results intuitive, a cable fault detector based on wave form reconstruction is designed. In this detector, the cable fault position is located based on the time-domain pulse reflection (TDR) principle. A pulse waveform is injected in the tested cable, and a high-speed comparator with changeable reference voltages is used to binarize the test pulse waveform to a binary sequence on a certain voltage. Through scanning the reference voltage in a full voltage range, multi-sequences are acquired to reconstruct the pulse waveform transmission in the cable, and then the pulse attenuation feature, electrical open circuit fault, electrical short circuit fault, and the fault position of the cable are diagnosed. Experimental results show that the designed cable fault detector can determine the fault type and its position of the cable being tested, and the testing results are intuitive. 展开更多
关键词 cable fault test waveform reconstruction fault position location time-domain pulse reflection
下载PDF
Cognitions and questions regarding crustal deformation and location forecasts of strong earthquakes 被引量:1
5
作者 Wei Wenxin Jiang Zaisen Wu Yanqiang 《Geodesy and Geodynamics》 2015年第3期210-219,共10页
Using Global Positioning System(GPS) data to analyze the earthquake preparation characteristics of the Kunlun Ms8.1 and the Wenchuan Ms8.0 earthquakes, we review the main research developments of earthquake forecastin... Using Global Positioning System(GPS) data to analyze the earthquake preparation characteristics of the Kunlun Ms8.1 and the Wenchuan Ms8.0 earthquakes, we review the main research developments of earthquake forecasting and the mechanisms of earthquake preparation using crustal deformation data from recent periods, and discuss the similarities and differences in the scientific approaches adopted by the Chinese and foreign scholars. We then analyze the deformation characteristics of earthquake preparation, with respect to slip and dip-slip faults. Our results show that, in order to understand the relationship between crustal deformation and earthquake preparation, research focus should be expanded from fault-scale to larger scale regions. Furthermore, the dynamic deformation characteristics associated with earthquake preparation must be considered as a multiscale, spatial-temporal process, in order to obtain the necessary criteria for strong earthquake forecasts. 展开更多
关键词 Global positioning System(GPS) Active fault Focal
下载PDF
Inverse-time Backup Protection Based on Unified Characteristic Equation for Distribution Networks with High Proportion of Distributed Generations
6
作者 Nana Chang Guobing Song +2 位作者 Zhongxue Chang Yuping Zheng Xingang Yang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第1期202-212,共11页
The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a ... The setting work of backup protection using steady-state current is tedious,and mismatches occasionally occur due to the increased proportion of distributed generations(DGs)connected to the power grid.Thus,there is a practical need to study a backup protection technology that does not require step-by-step setting and can be adaptively coordinated.This paper proposes an action sequence adaptive to fault positions that uses only positive sequence fault component(PSFC)voltage.Considering the influence of DGs,the unified time dial setting can be obtained by selecting specific points.The protection performance is improved by using the adjacent upstream and downstream protections to meet the coordination time interval in the case of metallic faults at the near-and far-ends of the line.Finally,the expression and implementation scheme for inverse-time backup protection(ITBP)based on the unified characteristic equation is given.Simulation results show that this scheme can adapt to DG penetration scenarios and can realize the adaptive coordination of multi-level relays. 展开更多
关键词 Inverse-time backup protection(ITBP) distributed generation(DG) positive sequence fault component(PSFC)voltage unified characteristic equation adaptive coordination
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部