By means of the numerical simulation software ANSYS, the activation regularity of coal floor faults caused by mining is simulated. The results indicate that the variation in horizontal, vertical and shear stresses, as...By means of the numerical simulation software ANSYS, the activation regularity of coal floor faults caused by mining is simulated. The results indicate that the variation in horizontal, vertical and shear stresses, as well as the horizontal and vertical displacements in the upper and the lower fault blocks at the workface are almost identical. Influ- enced by mining of the floor rock, there are stress releasing and stress rising areas at the upper part and at the footwall of the fault. The distribution of stress is influenced by the fault so that the stress isolines are staggered by the fault face and the stress is focused on the rock seam around the two ends of the fault. But the influence in fault activation on the upper or the lower fault blocks of the workface is markedly different. When the workface is on the footwall of the fault, there is a horizontal tension stress area on the upper part of the fault; when the workface is on the upper part of the fault, it has a horizontal compressive stress area on the lower fault block. When the workface is at the lower fault block, the maximum vertical displacement is 5 times larger then when the workface is on the upper fault block, which greatly in- creases the chance of a fatal inrush of water from the coal floor.展开更多
Event correlation is one key technique in network fault management. For the event sample acquisition problem in event correlation, a novel approach is proposed to collect the samples by constructing network simulation...Event correlation is one key technique in network fault management. For the event sample acquisition problem in event correlation, a novel approach is proposed to collect the samples by constructing network simulation platform. The platform designed can set kinds of network faults according to user's demand and generate a lot of network fault events, which will benefit the research on efficient event correlation techniques.展开更多
Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on...Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on the theory of Newton-Laphson power flow method,this simulation system imitates the primary device and secondary circuit,together with the normal,the abnormal and accidents in operation.Through simulation in various situations,it validates that this design is capable of simulating the complicated faults in UHV and EHV accurately and in real time.In addition,it can analyse and dispose them efficiently.展开更多
Fault zone trapped waves (FZTWs) mainly travel along the fractured fault zone (FZ) which is of low velocity and high attenuation. FZTWs often carry significant information about a fault's internal structure, so i...Fault zone trapped waves (FZTWs) mainly travel along the fractured fault zone (FZ) which is of low velocity and high attenuation. FZTWs often carry significant information about a fault's internal structure, so it is important to understand their wave field characteristics for FZ structure inversion. Most previous simulations are based on vertical faults, while in this paper we implement the FZTW simulations on vertical or inclined faults and compare their wave fields in both time and frequency domains. The results show that the existence of fault zone and inclined angle of fault can significantly influence the features of waves near faults. In amplitude, a fault zone can generate a larger amplitude of waves. The velocity contrast between two wails of fault may lead to amplification of amplitudes in the low velocity fault wall. In frequency, a fault zone tends to influence the waves in the low frequency range. In a pattern of particle polarization of FZTWs, it tends to be single direction for vertical faults but fork to multiple directions for inclined faults, which might provide a new way to study the fault zone with FZTWs. These conclusions may be valuable for FZ structure inversion, and will enhance the knowledge on near-fault strong ground motions.展开更多
The boiler is one of the key parts of power station. Monitoring the operation of the boiler automatically, continuously and accurately is very important. In case of malfunctions, an expert system might be helpful to f...The boiler is one of the key parts of power station. Monitoring the operation of the boiler automatically, continuously and accurately is very important. In case of malfunctions, an expert system might be helpful to find the sources of faults, and thereafter will assist the operator to act correctly and to prevent the fault from further development.In this paper, a simulation study of an expert system, which can diagnose the running faults of boiler system, is conducted. Shallow and deep two-layer knowledge base structure is used in this two layers of knowledge base. So. this kind of expert system can overcome the disadvantages of the old types of expert systems, which are only able to deal with experience rules base.A simulator of power boiler is used for the research on fault diagnose expert system. This boiler simulator gives all necessary information for the diagnosis. The knowledge base of expert system is built in hierarchies, so the speed of reasoning may be invreased. After the reasoning the展开更多
On the basis of the study of transient eddy current field in the end region of turbogenerator and electromagnetic force of end region winding, this paper analyzes the electromagnetic vibration of the turbogenerator r...On the basis of the study of transient eddy current field in the end region of turbogenerator and electromagnetic force of end region winding, this paper analyzes the electromagnetic vibration of the turbogenerator roundly. A 320 MW turbogenerator is taken as an example to specify the electromagnetic force of end region winding and therefore the vibration in the case that the generator is affected by impact load. Some conclusions are drawn on the basis of the specification. Vibration of windings under imaginary faults is simulated, so that the vibration law of the end winding of turbogenerator can be studied further. On the basis of this, the countermeasure against winding vibration can be advanced.展开更多
The world’s energy consumption and power generation demand will continue to rise.Furthermore,the bulk of the energy resources needed to satisfy the rising demand is far from the load centers.The aforementioned requir...The world’s energy consumption and power generation demand will continue to rise.Furthermore,the bulk of the energy resources needed to satisfy the rising demand is far from the load centers.The aforementioned requires long-distance transmission systems and one way to accomplish this is to use high voltage direct current(HVDC)transmission systems.The main technical issues for HVDC transmission systems are loss of synchronism,variation of quadrature currents,amplitude,the inability of station 1(rectifier),and station 2(inverter)to either inject,or absorb active,or reactive power in the network in any circumstances(before a fault occurs,during having a fault in network and after a fault cleared),and the variations of power transfer capabilities.Additionally,faults impact power quality such as voltage dips and power line outage time.This paper presents a method of overcoming the aforementioned technical issues using voltage-source converter(VSC)based HVDC transmission systems with SCADA VIEWER software and dynamic grid simulator.The benefits include having a higher capacity transmission system and proposed best method for control of active and reactive power transfer capabilities.Simulation results obtained using MATLAB validated the experimental results from SCADA Viewer software.The results indicate that the station’s rectifier or inverter can either inject or absorb either active power or reactive power in any circumstance.Also,the reverse power flow under different modes of operation can ride through faults.At a 100.0%power transfer rate,the rectifier injected 775.0 W into the network.At a 0.0%power transfer rate,the rectifier injected 164.0 W into the network.At a-100.0%rated power,the rectifier injected 1264.0 W into the network and direction was also changed.展开更多
Although lots of valuable results for fault diagnosis based on model have been achieved in linear system, it is difficult to apply these results to non-linear system due to the difficulty of modeling the non-linear sy...Although lots of valuable results for fault diagnosis based on model have been achieved in linear system, it is difficult to apply these results to non-linear system due to the difficulty of modeling the non-linear system by analysis. Adaptive Fuzzy system provides a way for solving this problem because it can approximate any non-linear system at any accuracy. The key for adaptive Fuzzy system to solve problem is its learning ability, so the authors present a learning algorithm for Adaptive fuzzy system, which can build the system's model by learning from the measurement data as well as experience knowledge with high accuracy. Furthermore, the experiment using the learning algorithm to model a servo-mechanism and to construct the fault diagnosis system based on the model is carried out, the results is very good.展开更多
Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach fo...Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach for virtual testability demonstration test based on stochastic process theory is proposed.First,the similarities and differences of fault sample generation between physical testability demonstration test and virtual testability demonstration test are discussed.Second,it is pointed out that the fault occurrence process subject to perfect repair is renewal process.Third,the interarrival time distribution function of the next fault event is given.Steps and flowcharts of fault sample generation are introduced.The number of faults and their occurrence time are obtained by statistical simulation.Finally,experiments are carried out on a stable tracking platform.Because a variety of types of life distributions and maintenance modes are considered and some assumptions are removed,the sample size and structure of fault sample simulation results are more similar to the actual results and more reasonable.The proposed method can effectively guide the fault injection in virtual testability demonstration test.展开更多
In order to cope with the most expensive stem fault simulation in fault simu-lation field, several accelerated techniques are presented in this paper. These techniques include static analysis on circuit structure in p...In order to cope with the most expensive stem fault simulation in fault simu-lation field, several accelerated techniques are presented in this paper. These techniques include static analysis on circuit structure in preprocessing stage and dynamic calculations in fault simulation stage. With these techniques,the area for stem fault simulation and number of the stems requiring explicit fault simulation are greatly reduced, so that the entire fault simulation time is substantially decreased. Experimental results given in this paper show that the fault simulation algorithm using these techniques is of very high efficiency for both small and large numbers of test patterns. Especially with the increase of circuit gates, its effectivenbss improves obyiously.展开更多
Critical path tracing,a fault simulation method for gate-level combinational circuits,is extended to theparallel critical path tracing for functional block-level combinational circuits.If the word length of the hostco...Critical path tracing,a fault simulation method for gate-level combinational circuits,is extended to theparallel critical path tracing for functional block-level combinational circuits.If the word length of the hostcomputer is m,then the parallel critical path tracing will be approximately m times faster than the originalone.展开更多
The true value simulation is necessary in the critical path tracing fault simulation algorithm.The critical and non-critical inputs can be known after the number of controlling and non-controlling inputs and the criti...The true value simulation is necessary in the critical path tracing fault simulation algorithm.The critical and non-critical inputs can be known after the number of controlling and non-controlling inputs and the criticality of output of every gate are determined.Single output region(SOR)is defined for non-critical lines,so many other non-critical lines can be obtained before fault simulation.Then deductive fault simulation algorithm is used to compute the fault list for every possible critical line from bottom to top,which can greatly decrease the length of fault list and simulation time.The cross-section is defined to reduce the storage space.The experimental results are given at the end of the paper.展开更多
Increasing IC densities necessitate diagnosis methodologies with enhanceddefect locating capabilities. Yet the computational effort expended in extracting diagnosticinformation and the stringent storage requirements c...Increasing IC densities necessitate diagnosis methodologies with enhanceddefect locating capabilities. Yet the computational effort expended in extracting diagnosticinformation and the stringent storage requirements constitute major concerns due to the tremendousnumber of faults in typical ICs. In this paper, we propose an RT-level diagnosis methodology capableof responding to these challenges. In the proposed scheme, diagnostic information is computed on agrouped fault effect basis, enhancing both the storage and the computational aspects. The faulteffect grouping criteria are identified based on a module structure analysis, improving thepropagation ability of the diagnostic information through RT modules. Experimental results show thatthe proposed methodology provides superior speed-ups and significant diagnostic informationcompression at no sacrifice in diagnostic resolution, compared to the existing gate-level diagnosisapproaches.展开更多
A new fault model, called the X-fault model, is proposed for fault diagnosisof physical defects with unknown behaviors by using X symbols. An efficient X-fault simulationmethod and an efficient X-fault diagnostic reas...A new fault model, called the X-fault model, is proposed for fault diagnosisof physical defects with unknown behaviors by using X symbols. An efficient X-fault simulationmethod and an efficient X-fault diagnostic reasoning method are presented. Fault diagnosis based onthe X-fault model can improve the accuracy of failure analysis for a wide range of physical defectsin complex and deep submicron integrated circuits.展开更多
基金Projects 50490273 and 50574090 supported by the National Natural Science Foundation of China, and 106084 by the Ministry of Education
文摘By means of the numerical simulation software ANSYS, the activation regularity of coal floor faults caused by mining is simulated. The results indicate that the variation in horizontal, vertical and shear stresses, as well as the horizontal and vertical displacements in the upper and the lower fault blocks at the workface are almost identical. Influ- enced by mining of the floor rock, there are stress releasing and stress rising areas at the upper part and at the footwall of the fault. The distribution of stress is influenced by the fault so that the stress isolines are staggered by the fault face and the stress is focused on the rock seam around the two ends of the fault. But the influence in fault activation on the upper or the lower fault blocks of the workface is markedly different. When the workface is on the footwall of the fault, there is a horizontal tension stress area on the upper part of the fault; when the workface is on the upper part of the fault, it has a horizontal compressive stress area on the lower fault block. When the workface is at the lower fault block, the maximum vertical displacement is 5 times larger then when the workface is on the upper fault block, which greatly in- creases the chance of a fatal inrush of water from the coal floor.
基金the National Natural Science Foundation of China(69983 0 0 5 )
文摘Event correlation is one key technique in network fault management. For the event sample acquisition problem in event correlation, a novel approach is proposed to collect the samples by constructing network simulation platform. The platform designed can set kinds of network faults according to user's demand and generate a lot of network fault events, which will benefit the research on efficient event correlation techniques.
基金China Postdoctoral Science Foundation(No.20080441149)Shandong Province Postdoctoral Innovation Program Foundation(No.200803036)SDUST Research Fund(No.2010KYTD101)
文摘Ultrahigh voltage(UHV)and extra-high voltage(EHV)have been widely used in power system,so the requirement for technology of operation management,as well as the accident analysis and disposal are more pressing.Based on the theory of Newton-Laphson power flow method,this simulation system imitates the primary device and secondary circuit,together with the normal,the abnormal and accidents in operation.Through simulation in various situations,it validates that this design is capable of simulating the complicated faults in UHV and EHV accurately and in real time.In addition,it can analyse and dispose them efficiently.
基金sponsored by the Key Basic Scientific Research Program of Institute of Earth Science,CEA(0213241302)
文摘Fault zone trapped waves (FZTWs) mainly travel along the fractured fault zone (FZ) which is of low velocity and high attenuation. FZTWs often carry significant information about a fault's internal structure, so it is important to understand their wave field characteristics for FZ structure inversion. Most previous simulations are based on vertical faults, while in this paper we implement the FZTW simulations on vertical or inclined faults and compare their wave fields in both time and frequency domains. The results show that the existence of fault zone and inclined angle of fault can significantly influence the features of waves near faults. In amplitude, a fault zone can generate a larger amplitude of waves. The velocity contrast between two wails of fault may lead to amplification of amplitudes in the low velocity fault wall. In frequency, a fault zone tends to influence the waves in the low frequency range. In a pattern of particle polarization of FZTWs, it tends to be single direction for vertical faults but fork to multiple directions for inclined faults, which might provide a new way to study the fault zone with FZTWs. These conclusions may be valuable for FZ structure inversion, and will enhance the knowledge on near-fault strong ground motions.
文摘The boiler is one of the key parts of power station. Monitoring the operation of the boiler automatically, continuously and accurately is very important. In case of malfunctions, an expert system might be helpful to find the sources of faults, and thereafter will assist the operator to act correctly and to prevent the fault from further development.In this paper, a simulation study of an expert system, which can diagnose the running faults of boiler system, is conducted. Shallow and deep two-layer knowledge base structure is used in this two layers of knowledge base. So. this kind of expert system can overcome the disadvantages of the old types of expert systems, which are only able to deal with experience rules base.A simulator of power boiler is used for the research on fault diagnose expert system. This boiler simulator gives all necessary information for the diagnosis. The knowledge base of expert system is built in hierarchies, so the speed of reasoning may be invreased. After the reasoning the
文摘On the basis of the study of transient eddy current field in the end region of turbogenerator and electromagnetic force of end region winding, this paper analyzes the electromagnetic vibration of the turbogenerator roundly. A 320 MW turbogenerator is taken as an example to specify the electromagnetic force of end region winding and therefore the vibration in the case that the generator is affected by impact load. Some conclusions are drawn on the basis of the specification. Vibration of windings under imaginary faults is simulated, so that the vibration law of the end winding of turbogenerator can be studied further. On the basis of this, the countermeasure against winding vibration can be advanced.
基金support through GrantNo.(600005-Z17X0234)Quanzhou Science and Technology Bureau for financial support through Grant No.(2018Z010)+2 种基金Huaqiao University through Grant No.(17BS201)the Fujian Provincial Department of Science and Technology for financial support through Grant(2018J05121)Authors are also grateful for financial support from the Fujian Provincial Department of Science and Technology through Grant Nos.(2021I0014)and(2018J05121).
文摘The world’s energy consumption and power generation demand will continue to rise.Furthermore,the bulk of the energy resources needed to satisfy the rising demand is far from the load centers.The aforementioned requires long-distance transmission systems and one way to accomplish this is to use high voltage direct current(HVDC)transmission systems.The main technical issues for HVDC transmission systems are loss of synchronism,variation of quadrature currents,amplitude,the inability of station 1(rectifier),and station 2(inverter)to either inject,or absorb active,or reactive power in the network in any circumstances(before a fault occurs,during having a fault in network and after a fault cleared),and the variations of power transfer capabilities.Additionally,faults impact power quality such as voltage dips and power line outage time.This paper presents a method of overcoming the aforementioned technical issues using voltage-source converter(VSC)based HVDC transmission systems with SCADA VIEWER software and dynamic grid simulator.The benefits include having a higher capacity transmission system and proposed best method for control of active and reactive power transfer capabilities.Simulation results obtained using MATLAB validated the experimental results from SCADA Viewer software.The results indicate that the station’s rectifier or inverter can either inject or absorb either active power or reactive power in any circumstance.Also,the reverse power flow under different modes of operation can ride through faults.At a 100.0%power transfer rate,the rectifier injected 775.0 W into the network.At a 0.0%power transfer rate,the rectifier injected 164.0 W into the network.At a-100.0%rated power,the rectifier injected 1264.0 W into the network and direction was also changed.
文摘Although lots of valuable results for fault diagnosis based on model have been achieved in linear system, it is difficult to apply these results to non-linear system due to the difficulty of modeling the non-linear system by analysis. Adaptive Fuzzy system provides a way for solving this problem because it can approximate any non-linear system at any accuracy. The key for adaptive Fuzzy system to solve problem is its learning ability, so the authors present a learning algorithm for Adaptive fuzzy system, which can build the system's model by learning from the measurement data as well as experience knowledge with high accuracy. Furthermore, the experiment using the learning algorithm to model a servo-mechanism and to construct the fault diagnosis system based on the model is carried out, the results is very good.
基金National Natural Science Foundation of China(51105369)
文摘Virtual testability demonstration test has many advantages,such as low cost,high efficiency,low risk and few restrictions.It brings new requirements to the fault sample generation.A fault sample simulation approach for virtual testability demonstration test based on stochastic process theory is proposed.First,the similarities and differences of fault sample generation between physical testability demonstration test and virtual testability demonstration test are discussed.Second,it is pointed out that the fault occurrence process subject to perfect repair is renewal process.Third,the interarrival time distribution function of the next fault event is given.Steps and flowcharts of fault sample generation are introduced.The number of faults and their occurrence time are obtained by statistical simulation.Finally,experiments are carried out on a stable tracking platform.Because a variety of types of life distributions and maintenance modes are considered and some assumptions are removed,the sample size and structure of fault sample simulation results are more similar to the actual results and more reasonable.The proposed method can effectively guide the fault injection in virtual testability demonstration test.
文摘In order to cope with the most expensive stem fault simulation in fault simu-lation field, several accelerated techniques are presented in this paper. These techniques include static analysis on circuit structure in preprocessing stage and dynamic calculations in fault simulation stage. With these techniques,the area for stem fault simulation and number of the stems requiring explicit fault simulation are greatly reduced, so that the entire fault simulation time is substantially decreased. Experimental results given in this paper show that the fault simulation algorithm using these techniques is of very high efficiency for both small and large numbers of test patterns. Especially with the increase of circuit gates, its effectivenbss improves obyiously.
基金The project is supported by the National Natural Science Foundation of China.
文摘Critical path tracing,a fault simulation method for gate-level combinational circuits,is extended to theparallel critical path tracing for functional block-level combinational circuits.If the word length of the hostcomputer is m,then the parallel critical path tracing will be approximately m times faster than the originalone.
文摘The true value simulation is necessary in the critical path tracing fault simulation algorithm.The critical and non-critical inputs can be known after the number of controlling and non-controlling inputs and the criticality of output of every gate are determined.Single output region(SOR)is defined for non-critical lines,so many other non-critical lines can be obtained before fault simulation.Then deductive fault simulation algorithm is used to compute the fault list for every possible critical line from bottom to top,which can greatly decrease the length of fault list and simulation time.The cross-section is defined to reduce the storage space.The experimental results are given at the end of the paper.
文摘Increasing IC densities necessitate diagnosis methodologies with enhanceddefect locating capabilities. Yet the computational effort expended in extracting diagnosticinformation and the stringent storage requirements constitute major concerns due to the tremendousnumber of faults in typical ICs. In this paper, we propose an RT-level diagnosis methodology capableof responding to these challenges. In the proposed scheme, diagnostic information is computed on agrouped fault effect basis, enhancing both the storage and the computational aspects. The faulteffect grouping criteria are identified based on a module structure analysis, improving thepropagation ability of the diagnostic information through RT modules. Experimental results show thatthe proposed methodology provides superior speed-ups and significant diagnostic informationcompression at no sacrifice in diagnostic resolution, compared to the existing gate-level diagnosisapproaches.
文摘A new fault model, called the X-fault model, is proposed for fault diagnosisof physical defects with unknown behaviors by using X symbols. An efficient X-fault simulationmethod and an efficient X-fault diagnostic reasoning method are presented. Fault diagnosis based onthe X-fault model can improve the accuracy of failure analysis for a wide range of physical defectsin complex and deep submicron integrated circuits.