期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Clinical outcomes of transepithelial photorefractive keratectomy versus femtosecond laser assisted keratomileusis for correction of high myopia in South Egyptian population 被引量:4
1
作者 Amr Mounir Engy Mohamed Mostafa +4 位作者 Hatem Ammar Osama Ali Mohammed Alahmady Hamad Alsmman Mahmoud Mohamed Farouk Mohamed Gamal Elghobaier 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2020年第1期129-134,共6页
AIM: To evaluate the safety and efficacy of transepithelial photorefractive keratectomy(t-PRK) with adjuvant mitomycin C(MMC) versus femtosecond laser assisted keratomileusis(Femto-LASIK) in correction of high myopia.... AIM: To evaluate the safety and efficacy of transepithelial photorefractive keratectomy(t-PRK) with adjuvant mitomycin C(MMC) versus femtosecond laser assisted keratomileusis(Femto-LASIK) in correction of high myopia.METHODS: Prospective randomized comparative study including 156 eyes of 156 patients with high myopia and a spherical equivalent refraction(SER) <-6.00 D. They were divided randomly into two groups: Group A included 72 eyes treated with t-PRK with adjuvant MMC and Group B included 84 eyes treated with Femto-LASIK. Visual acuity, SER, corneal topography, pachymetry and keratometry were assessed for 12 mo postoperatively.RESULTS: The preoperative mean SER was-8.86±1.81 and-9.25±1.70 D in t-PRK MMC group and Femto-LASIK respectively(P=0.99) which improved to-0.65±0.43 D and-0.69±0.50 D at 12 mo follow up. Mean SER remained stable during the 12 mo of follow-up, with no statistically significant difference between the two groups(P=0.64). In t-PRK MMC group, only six eyes needed retreatment after six months of follow up. And two eyes showed haze(one reversible haze grade 2, while the other had dense irreversible haze grade 4).CONCLUSION: t-PRK MMC provides safe and satisfactory visual outcomes and acceptable risk as Femto-LASIK in patients with high myopia. 展开更多
关键词 transepithelial photorefractive keratectomy femtosecond laser assisted keratomileusis high myopia corneal haze Egypt
下载PDF
Optical and visual quality comparison of implantable collamer lens and femtosecond laser assisted laser in situ keratomileusis for high myopia correction 被引量:2
2
作者 Zheng Jiang Hua Wang +1 位作者 Dong-Qiang Luo Jiao Chen 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第5期737-743,共7页
AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optica... AIM:To compare clinical outcomes and refractive stability of implantable collamer lens(ICL)implantation and femtosecond laser assisted laser in situ keratomileusis(FSLASIK)for high myopia correction.METHODS:The Optical Quality Analysis System(OQAS)was used to evaluate clinical outcomes objectively after operation for high myopia correction.We compared the two procedures in terms of 1-year changes in uncorrected distance visual acuity(UDVA),corrected distance visual acuity(CDVA),safety index,efficacy index,spherical equivalent,modulation transfer function(MTF)cutoff frequency,strehl ratio(SR)and objective scatter index(OSI).RESULTS:At 1 y postoperatively,the safety indices were 1.33±0.27 in ICL group,and 1.17±0.24 in FS-LASIK group.39.58%in the ICL group and 27.59%in the FS-LASIK group gained CDVA in 2 lines or better than that in preoperative CDVA.The efficacy indices were 1.28±0.22 in ICL group,and 1.13±0.26 in FS-LASIK group.The changes of spherical equivalent from 1 wk to 1 y postoperatively was-0.12±0.37 D in ICL group,and-0.79±0.58 D in FS-LASIK group(P<0.05).Spherical equivalent within±0.50 D was achieved in 97.92%in ICL group and 68.97%in FS-LASIK group.MTF cutoff frequency were higher with ICL as compared to FSLASIK(P<0.05)at each postoperative follow-up stage;for postoperative 1 mo later,SR was statistically significant difference between two groups(P<0.05);with no statistically significant difference in OSI between two groups(P>0.05)in postoperative 3 mo later.CONCLUSION:ICL implantation and FS-LASIK procedures both provide good safety and predictability in high myopia correction.ICL implantation provides better clinical outcomes and refractive stability than FS-LASIK. 展开更多
关键词 implantable collamer lens implantation femtosecond laser assisted laser in situ keratomileusis refractive stability high myopia
下载PDF
Differences in energy and corneal endothelium between femtosecond laser-assisted and conventional cataract surgeries:prospective,intraindividual,randomized controlled trial 被引量:6
3
作者 Lucia Bascaran Txomin Alberdi +2 位作者 Itziar Martinez-Soroa Cristina Sarasqueta Javler Mendlcute 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第8期1308-1316,共9页
AIM: To compare intraoperative phacoemulsification parameters and its effect on the corneal endothelium of eyes undergoing femtosecond laser-assisted cataract surgery(FLACS) versus conventional phacoemulsification... AIM: To compare intraoperative phacoemulsification parameters and its effect on the corneal endothelium of eyes undergoing femtosecond laser-assisted cataract surgery(FLACS) versus conventional phacoemulsification(CP) cataract surgery.METHODS: Two hundred eyes from one hundred patients were included in a prospective, non-blinded, randomized, controlled, intraindividual clinical study. One hundred eyes underwent FLACS while their one hundred fellow eyes underwent CP. All surgeries were performed using the Victus? femtosecond laser platform and Infinity? Vision System phacoemulsification machine. Primary outcome measure was endothelial cell density 6 mo after surgery. Secondary outcome measures included central corneal thickness(CCT), average cell area, standard deviation, coefficient of variation and hexagonality before surgery and 6 mo after surgery and endothelial cell density loss during this period were also evaluated. Intraoperative efficiency parameters [cumulative dissipated energy(CDE), total intraocular surgery time, total ultrasound time, total phacoemulsification time, total torsional energy time, total aspiration time, ultrasound energy, torsional amplitude and fluid required during surgery] were also collated. RESULTS: Data from these patients was not considered for analysis. Data from 92 patients were analysed. Postoperative endothelial cell density(cells/mm2) between groups(2211.88±392.49 CP; 2246.31±403.48 FLACS) was not statistically significant(P=0.869). Total ultrasound time, torsional energy time, CDE and fluid requirements were significantly lower the FLACS group(P〈0.05). Other parameters did not show statistically significant difference between FLACS and CP.CONCLUSION: FLACS displays significant improvements in phacoemulsification parameters in comparison to CP. There are no significant differences in corneal endothelium measures between FLACS and CP. 展开更多
关键词 CATARACT femtosecond laser assisted cataractsurgery phacoemulsification parameters corneal endothelium endothelial cell morphology
下载PDF
Human lens epithelial cell apoptosis and epithelial to mesenchymal transition in femtosecond laser-assisted cataract surgery 被引量:3
4
作者 Wei Sun Jia Liu +5 位作者 Jing Li Di Wu Jing Wang Ming-Wu Wang Jin-Song Zhang Jiang-Yue Zhao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期401-407,共7页
AIM: To evaluate human lens epithelium cell apoptosis and epithelial to mesenchymal transition (EMT) induced by femtosecond laser in femtosecond laser assisted cataract surgery (FLACS). METHODS: Sixty cataract ... AIM: To evaluate human lens epithelium cell apoptosis and epithelial to mesenchymal transition (EMT) induced by femtosecond laser in femtosecond laser assisted cataract surgery (FLACS). METHODS: Sixty cataract patients with N2 to N3 stage according to the LOCS III were enrolled in this study and divided into three groups randomly: FLACSl group (cataract surgery by FLACS with LenSx), FLACS2 group (cataract surgery by FLACS with LensAR) and manual group (cataract surgery by phacoemulsification). Patients in two FLACS groups performed anterior capsulotomy by LenSx or LensAR laser system. Patients in the manual group were performed continuous curvilinear capsulorrhexis (CCC) manually. The anterior capsules were fixed right after moved out of eye. Hematoxylin-eosine staining, immunofluorescence staining and real-time PCR were performed in order to observe human lens epithelium cells changes after cataract surgery. RESULTS: The capsule cutting edge was shown irregularity and roughness in two FLACS groups and smooth edge in manual capsulotomy by pathologic staining. Irregularities of the cell configuration with partly swollen and destroyed nuclei were observed in two FLACS groups. Femtosecond laser could induce a significantly higher cell apoptosis in human lens epithelium cell than manually performed CCC (P〈0.05). Lens epithelium cells apoptosis were correlated with femtosecond laser duration according to Pearson correlation analysis. Decreased N-cadherin expression, alpha-SMA and FSP-1 level in two FLACS groups showed the inhibition of cell EMT. CONCLUSION: Femtosecond laser may affect the apoptosis and EMT of lens epithelium cells which are under the peeled central lens capsule. 展开更多
关键词 femtosecond lasers assisted cataract surgery lens epithelium cell APOPTOSIS epithelial mesenchymal transition
下载PDF
Safety of femtosecond laser-assisted cataract surgery versus conventional phacoemulsification for cataract:A meta-analysis and systematic review
5
作者 Jingjie Xu Xinyi Chen +1 位作者 Hanle Wang Ke Yao 《Advances in Ophthalmology Practice and Research》 2022年第1期1-9,共9页
Purpose:To compare the complications of femtosecond laser-assisted cataract surgery(FLACS)with those of conventional phacoemulsification surgery(CPS)for age-related cataracts.Methods:PubMed,Cochrane Library,and EMBASE... Purpose:To compare the complications of femtosecond laser-assisted cataract surgery(FLACS)with those of conventional phacoemulsification surgery(CPS)for age-related cataracts.Methods:PubMed,Cochrane Library,and EMBASE were systematically searched for studies comparing FLACS and CPS.Outcomes were operative complications,including the intraoperative capsule tear,postoperative corneal edema,macular edema,uncontrolled IOP,etc.The effect measures were weighted with odds ratios with 95%CIs.Results:Nineteen RCTs and 18 cohort studies,including 24,806 eyes(11,375 of the FLACS group and 13,431 of the CPS group),were identified.There were no significant differences between the two groups in anterior capsule tear,corneal edema,macular edema,uncontrolled IOP,vitreous loss,posterior vitreous detachment,etc.Posterior capsule tear rate showed a significantly lower in RCT subgroups(P=0.04)and without differences in total(P=0.63).Significant differences were observed in the incidence of descemet membrane tear/trauma(P=0.02)and IFIS/iris trauma(P=0.04.Additionally,The FLACS specific complications showed a significantly higher rate of miosis(P=0.0001),corneal epithelial defect(P=0.001),corneal haze(P=0.002),and subconjunctival hemorrhage(P=0.01).Conclusions:FLACS maintains the same safety compared with CPS in terms of all intraoperative and postoperative complications.Although FLACS did show a statistically significant difference for several FLACS specific complications,it would not influence the visual outcome and heal itself. 展开更多
关键词 femtosecond laser assisted cataract surgery Conventional phacoemulsification surgery SAFETY Complication Capsular tear rate
原文传递
Ablation enhancement by defocused irradiation assisted femtosecond laser fabrication of stainless alloy 被引量:1
6
作者 褚东凯 银恺 +3 位作者 董欣然 罗志 宋雨欣 段吉安 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第1期53-56,共4页
We evaluate the effects of the holes geometry drilled by a femtosecond laser on a stainless alloy with various defocused irradiation time, which ranges from 0 min to 1 h. The laser ablation efficiency is increased by ... We evaluate the effects of the holes geometry drilled by a femtosecond laser on a stainless alloy with various defocused irradiation time, which ranges from 0 min to 1 h. The laser ablation efficiency is increased by a factor of3 when the irradiation time is elevated from 0 to 30 min. Also, the morphology of the hole is observed by a scanning electron microscope, where the result indicates that the defocused irradiation time has a significant influence on the morphology changes. The reason for such changes is discussed based on the pretreatment effect and the confined plasma plume. As an application example, the microchannel is fabricated by a femtosecond laser combined with the defocused irradiation to demonstrate the advantage of the proposed method in fabricating functional structures. 展开更多
关键词 Ablation enhancement by defocused irradiation assisted femtosecond laser fabrication of stainless alloy
原文传递
Early results of circularity and centration of capsulotomy prepared by three different methods 被引量:4
7
作者 Jagadesh C.Reddy Soumya Devta +2 位作者 Kiran Kumar Vupparaboina Mohammad Hasnat Ali Pravin K.Vaddavalli 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第1期76-82,共7页
AIM:To compare the difference of capsulotomy produced by precision pulse capsulotomy(PPC),manual(M-CCC),and femtosecond laser assisted capsulotomy(FLAC)in relation to intraocular lens(IOL)centration,circularity and it... AIM:To compare the difference of capsulotomy produced by precision pulse capsulotomy(PPC),manual(M-CCC),and femtosecond laser assisted capsulotomy(FLAC)in relation to intraocular lens(IOL)centration,circularity and its effect on visual outcomes.METHODS:Prospective,non-randomized comparative study conducted at LV Prasad Eye Institute,Hyderabad,India.Sixty eyes of 52 patients were grouped into 3(FLAC,PPC and M-CCC)based on capsulotomy techniques used.Twenty consecutive eyes with uneventful phacoemulsification and with no comorbidities affecting the capsulotomy or visual outcome were included in each group.The main outcome measure was IOL centration in relation to capsulotomy and pupil.Secondary outcome measures were post-operative visual acuity,manifest refraction and aberration profile between groups.RESULTS:At 5 wk the visual,refractive outcomes and endothelial cell density were comparable between the 3 groups.The median circularity index of FLAC was statistically significantly different to M-CCC or PPC(1-10)groups(P<0.01)but PPC(11-20)was comparable to FLAC.Decentration of IOL center in relation to capsulotomy was seen only between the PPC(1-10)group and FLAC group(P=0.02).The IOL was well centered in relation to the pupil in all the groups(P=0.46).The quality of vision parameters like the higher order aberrations,spherical aberration,coma,trefoil,modular transfer function,and Strehl ratio were comparable between the groups.CONCLUSION:Our study shows that despite differences in the morphology of capsulotomy produced by PPC,M-CCC,FLAC a well-centered IOL can be achieved.The measured capsular morphology parameters do not affect visual outcomes. 展开更多
关键词 PHACOEMULSIFICATION CAPSULOTOMY intraocular lens centration precision pulse capsulotomy femtosecond laser assisted capsulotomy
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部