期刊文献+
共找到42篇文章
< 1 2 3 >
每页显示 20 50 100
Three-year results of small incision lenticule extraction and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis for correction of high myopia and myopic astigmatism 被引量:20
1
作者 Li-Kun Xia Jing Ma +2 位作者 He-Nan Liu Ce Shi Qing Huang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2018年第3期470-477,共8页
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui... AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve more stable long-term refractive outcome and better control of early postoperative dry eye as compared to FS-LASIK. 展开更多
关键词 small incision lenticule extraction wavefront-guided femtosecond laser-assisted laser in situ keratomileusis femtosecond laser refractive surgery visual outcome
下载PDF
Dry eye and corneal sensitivity after small incision lenticule extraction and femtosecond laser-assisted in situ keratomileusis:a Meta-analysis 被引量:10
2
作者 Wen-Ting Cai Qing-Yu Liu +6 位作者 Cheng-Da Ren Qing-Quan Wei Jun-Ling Liu Qian-Yi Wang Ya-Ru Du Meng-Mei He Jing Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第4期632-638,共7页
AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was p... AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was performed using Rev Man 5.3.We searched on Pub Med from inception to March 2016.Summary weighted mean difference(WMD) and 95% confidence intervals(CIs) were used to analyze the datum.Random-effects or fixed-effects models were chosen up to between-study heterogeneity.The main outcomes were composed of the Ocular Surface Disease Index(OSDI) scores,tear film break-up time(TBUT),Schirmer Test and corneal sensitivity.RESULTS:Eight eligible studies including 772 eyes(386 in SMILE group and 386 in FS-LASIK group) were identified.The parameters have no significiant difference heterogeneity between SMILE and FS-LASIK group preoperatively.There were significant differences between the two groups in OSDI scores at one and three months postoperatively,in TBUT at one and three months postoperatively,in corneal sensitivity at one week,about one month and three months postoperatively.However,there was no significant difference observed in Schirmer Test at the follow-up periods.CONCLUSION:Compare to FS-LASIK,dry eye and the corneal sensitivity recover better in the SMILE group,in first three months after the surgery. 展开更多
关键词 dry eye corneal sensation small incision lenticule extraction femtosecond laser-assisted in situ keratomileusis META-ANALYSIS
下载PDF
SMILE与FS-LASIK术后屈光状态偏差原因分析及结果评价
3
作者 李颖 徐江保 +2 位作者 范淑琪 吴泽德 李俊 《临床眼科杂志》 2024年第4期298-303,共6页
目的观察飞秒激光制瓣联合准分子激光原位角膜磨镶术(FSLASIK)与飞秒激光小切口角膜基质透镜取出术(SMILE)术后屈光状态偏差,并分析其结果和原因。方法回顾性临床研究。按照手术方式分为两组,FSLASIK组300例(600只眼),按照手术时间再分... 目的观察飞秒激光制瓣联合准分子激光原位角膜磨镶术(FSLASIK)与飞秒激光小切口角膜基质透镜取出术(SMILE)术后屈光状态偏差,并分析其结果和原因。方法回顾性临床研究。按照手术方式分为两组,FSLASIK组300例(600只眼),按照手术时间再分为pre FSLASIK 200例(400只眼),FSLASIK 100例(200只眼),SMILE组100例(200只眼),术前球镜度-0.75~12.25 D,柱镜度0~3.75 D,均未预留度数,最佳矫正视力(BCVA)≥1.0,分别于术前、术后1 d、1周、1个月、3个月、6个月复查并记录所有患者非接触眼压测量、裸眼视力(UCVA)、BCVA、等效球镜(SE)、电脑验光、裂隙灯显微镜检查。对因素进行相关分析得到结果后,建立回归模型,进行回归分析,根据结果进一步分析。结果术后屈光状态主要受手术方式及术前柱镜的影响(P<0.05),FSLASIK术后患者右眼柱镜结果与SMILE术后患者右眼柱镜结果在术后7 d、1个月、3个月、6个月差异均有统计学意义(P<0.05),左右眼术后屈光状态无相关性。结论SMILE术后患者平均右眼柱镜欠矫程度较FSLASIK术后患者多0.25~0.50 D,主要与SMILE手术方式、眼球自旋以及角膜上皮重塑行为有关,建议高度数患者采用FSLASIK手术或更改SMILE手术方式为扫描后即刻取镜。 展开更多
关键词 飞秒激光制瓣联合准分子激光原位角膜磨镶术 全飞秒激光小切口角膜透镜取出术 屈光状态偏差 屈光参差
下载PDF
FS-LASIK术后视网膜周边离焦及视觉质量变化
4
作者 李羽 郭玉 +2 位作者 娟汪思瑶 张美美 周跃华 《眼科新进展》 CAS 北大核心 2024年第7期558-563,共6页
目的探讨飞秒激光辅助的准分子激光原位角膜磨镶术(FS-LASIK)术后视网膜周边离焦及视觉质量的变化。方法选取2023年3月至5月在成都中医大银海眼科医院行FS-LASIK的近视患者51例(102眼)纳入研究,其中女27例(54眼),男24例(48眼)。使用多... 目的探讨飞秒激光辅助的准分子激光原位角膜磨镶术(FS-LASIK)术后视网膜周边离焦及视觉质量的变化。方法选取2023年3月至5月在成都中医大银海眼科医院行FS-LASIK的近视患者51例(102眼)纳入研究,其中女27例(54眼),男24例(48眼)。使用多光谱屈光地形图仪测量视网膜周边离焦。记录视网膜周边总屈光差异值(TRDV);四个象限的RDV:上方RDV(RDV-S)、下方RDV(RDV-I)、鼻侧RDV(RDV-N)及颞侧RDV(RDV-T);距黄斑中心凹10°、20°、30°、40°及53°相应同心圆环区域的RDV(分别表示为RDV 0°-10°、RDV 10°-20°、RDV 20°-30°、RDV 30°-40°、RDV 40°-53°)。采用视觉质量分析系统测量并记录客观散射指数(OSI)、斯特列尔比(SR),10 c·d^(-1)、20 c·d^(-1)、30 c·d^(-1)空间频率下的调制传递函数(MTF)值(分别表示为10 c·d^(-1) MTF、20 c·d^(-1) MTF、30 c·d^(-1) MTF)以及截止频率(MTF cutoff)。采用iTrace像差仪测量并记录角膜垂直三叶草(Z_(3)^(-3))、垂直彗差(Z_(3)^(-1))、水平彗差(Z_(3)^(1))、水平三叶草(Z_(3)^(3))、垂直四叶草(Z_(4)^(-4))、垂直二次散光(Z_(4)^(-2))、球差(Z_(4)^(0))、水平二次散光(Z_(4)^(2))、水平四叶草(Z_(4)^(4))及总高阶像差(HOA)的数据。对患者术前、术后1个月及术后3个月的测量数据进行比较及相关性分析。结果术前、术后1个月及术后3个月患者视网膜周边TRDV、RDV-S、RDV-N、RDV 20°-30°、RDV 30°-40°、RDV 40°-53°比较,术后1个月及3个月的值均较术前降低,差异均有统计学意义(均为P<0.001)。术前、术后1个月及术后3个月患者OSI、MTF cutoff及10 c·d^(-1) MTF比较,差异均有统计学意义(均为P<0.05)。术前、术后1个月及术后3个月患者角膜Z_(3)^(-3)、Z_(3)^(-1)、Z_(3)^(1)、Z_(3)^(3)、Z_(4)^(-4)、Z_(4)^(-2)、Z_(4)^(0)、Z_(4)^(2)、Z_(4)^(4)及HOA比较,差异均有统计学意义(均P<0.001)。Pearson相关分析结果显示,ΔRDV 0°-10°与ΔZ_(3)^(-3)、ΔZ_(3)^(1)、ΔZ_(4)^(-2)、ΔZ_(4)^(0)及ΔZ_(4)^(2)均呈正相关(均为P<0.05);ΔRDV 10°-20°与ΔZ_(4)^(-4)及ΔZ_(4)^(-2)呈正相关(均为P<0.05);ΔRDV 20°-30°与ΔZ_(4)^(-4)及ΔZ_(4)^(4)呈正相关(均为P<0.05);ΔTRDV、ΔRDV 40°-53°均与ΔHOA呈负相关(均为P<0.05)。ΔRDV-S与ΔZ_(3)^(-1)及ΔHOA呈负相关(均为P<0.05),与ΔZ_(4)^(4)呈正相关(P<0.05);ΔRDV-N与ΔZ_(4)^(-4)呈正相关(P<0.05)。结论FS-LASIK能降低近视患者视网膜周边远视离焦,但引入了部分角膜高阶像差,且两者存在一定的相关性。 展开更多
关键词 飞秒激光 准分子激光角膜原位磨镶术 周边离焦 视觉质量 高阶像差
下载PDF
FS-LASIK矫正中高度近视术后1年屈光回退危险因素及其预测模型构建
5
作者 李仲佶 韦伟 段宇辉 《国际眼科杂志》 CAS 2024年第6期954-959,共6页
目的:探讨飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)矫正中高度近视术后1 a屈光回退的危险因素并构建预测模型。方法:回顾性分析2017-06/2018-11于西安高新医院行FS-LASIK手术矫正中高度近视患者400例800眼临床资料,将患者按照3... 目的:探讨飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)矫正中高度近视术后1 a屈光回退的危险因素并构建预测模型。方法:回顾性分析2017-06/2018-11于西安高新医院行FS-LASIK手术矫正中高度近视患者400例800眼临床资料,将患者按照3∶1的比例随机分为建模组(n=300例)和验证组(n=100例),依照患者术后1 a屈光回退发生情况将建模组分为回退组与未回退组两个亚组,观察其角膜曲率和角膜厚度变化情况,采用Logistic回归分析筛选FS-LASIK矫正中高度近视患者术后1 a屈光回退的危险因素,基于回归系数构建预测模型,采用受试者工作特征曲线(ROC)评估模型区分度。结果:建模组44眼、验证组15眼于术后1 a发生屈光回退。建模组中未回退组术后6、12 mo时角膜前表面曲率低于回退组(均P<0.05);术后1、3、6、12 mo时回退组角膜增生程度大于未回退组(均P<0.05);FS-LASIK矫正中高度近视患者术后1 a屈光回退发生概率值回归方程为:P=1/[1+e^(-(-5.989+0.127×年龄+2.019×术前屈光度-0.022×术前角膜中央厚度+0.043×切削深度-1.569×切削光学区直径))],Hosmer-Lemeshow检测回归方程拟合优度(P=0.818),利用建模组数据进行内部验证,ROC曲线下面积为0.890(95%CI 0.843-0.937),灵敏度为81.82%,特异度为84.71%;利用验证组数据进行外部验证,ROC曲线下面积为0.838(95%CI 0.717-0.959),灵敏度为80.00%,特异度为87.57%。结论:构建的风险模型判别效度良好,可用于识别中高度近视患者行FS-LASIK术后1 a屈光回退高危人群。 展开更多
关键词 飞秒激光辅助准分子激光原位角膜磨镶术 中高度近视 屈光回退 角膜地形图 预测模型
下载PDF
Comparison of early changes in ocular surface markers and tear inflammatory mediators after femtosecond lenticule extraction and FS-LASIK 被引量:2
6
作者 Chi Zhang Hui Ding +5 位作者 Hong He He Jin Liang-Ping Liu Xiao-Wei Yang Jun Yang Xing-Wu Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2021年第2期283-291,共9页
AIM:To compare the short-term impacts of femtosecond lenticule extraction(FLEx)and femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)on ocular surface measures and tear inflammatory mediators.METHODS:Th... AIM:To compare the short-term impacts of femtosecond lenticule extraction(FLEx)and femtosecond laser-assisted laser in situ keratomileusis(FS-LASIK)on ocular surface measures and tear inflammatory mediators.METHODS:This prospective comparative nonrandomized clinical study comprised 75 eyes(75 patients).Totally 20 male and 15 female patients(age 21.62±3.25 y)with 35 eyes underwent FLEx,and 26 male and 14 female patients(age 20.18±3.59 y)with 40 eyes underwent FS-LASIK.Central corneal sensitivity,noninvasive tear breakup time,corneal fluorescein staining,Schirmer I test,tear meniscus height,and ocular surface disease index were evaluated in all patients.Tear concentrations of nerve growth factor(NGF),interleukin-1α(IL-1α),transforming growth factor-β1(TGF-β1),tumor necrosis factor-α(TNF-α),interferon-γ(IFN-γ),and matrix metalloproteinase-9(MMP-9)were assessed by multiplex antibody microarray.All measurements were performed preoperatively,and 1 d,1 wk,and 1 mo postoperatively.RESULTS:Patients who underwent FLEx exhibited a more moderate reduction in central corneal sensation and less corneal fluorescein staining than those in the FS-LASIK group 1 wk after the procedure(P<0.01).NGF was significantly higher 1 d and 1 wk after surgery in the FS-LASIK group than in the FLEx group(P<0.01).By contrast,compared to those in the FLEx group,higher postoperative values and slower recovery of tear TGF-β1,IL-1α,and TNF-αconcentrations were observed in the FS-LASIK group(P<0.01).Tear concentrations of NGF,TGF-β1,TNF-α,and IL-1αwere correlated with ocular surface changes after FLEx or FS-LASIK surgery.CONCLUSION:There is less early ocular surface disruption and a reduced inflammatory response after FLEx than after FS-LASIK.NGF,TGF-β1,TNF-α,and IL-1αmay contribute to the process of ocular surface recovery. 展开更多
关键词 femtosecond lenticule extraction femtosecond laser-assisted laser in situ keratomileusis tear inflammatory mediators ocular surface
下载PDF
Changes in corneal biomechanics and posterior corneal surface elevation after FS-LASIK 被引量:2
7
作者 Zhong-Ji Li Chen Yang +2 位作者 Su-Han Liu Jiao Guo Yu-Hui Duan 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第11期1832-1837,共6页
AIM:To investigate the changes in corneal biomechanics and posterior corneal surface elevation after femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS:Totally 197 eyes of 100 patients who underwent t... AIM:To investigate the changes in corneal biomechanics and posterior corneal surface elevation after femtosecond laser-assisted in situ keratomileusis(FS-LASIK).METHODS:Totally 197 eyes of 100 patients who underwent the FS-LASIK from April 2022 to November 2022 were included.They were divided into three groups according to the ratio of residual corneal stroma thickness/corneal thickness(RCST/CT):Group I(50%≤RCST/CT<55%,63 eyes of 32 patients),Group II(55%≤RCST/CT<60%,67 eyes of 34 patients),and Group III(RCST/CT≥60%,67 eyes of 34 patients).The intraocular pressure(IOP),corneal compensated IOP(IOPcc),corneal hysteresis(CH)and corneal resistance factor(CRF)were measured immediately,1,and 3mo postoperatively by ocular response analyzer(ORA)and the posterior elevation difference(PED)was measured by Pentacam.RESULTS:After operation,IOP,CH,CRF,and PED were statistically different among the three groups(F=12.99,31.148,23.998,all P<0.0001).There was no statistically significant difference in IOPcc among the three groups(F=0.603,P>0.05).The IOP,IOPcc,CH,and CRF were statistical changed after surgery(F=699.635,104.125,308.474,640.145,all P<0.0001).The PED of Group I was significantly higher than that of Group II(P<0.05),and Group II was significantly higher than that of Group III(P<0.05).The PED value of 3mo after surgery decreased in each group compared with 1mo after surgery,but there was no statistical difference(Group I:t=0.82,P=0.41;Group II:t=0.17,P=0.87;Group III:t=1.35,P=0.18).The correlation analysis of corneal biomechanical parameter changes with PED at 1mo and 3mo after surgery showed thatΔIOP,ΔIOPcc,ΔCH,andΔCRF were not correlated with PED value in three groups(P>0.05).CONCLUSION:The smaller the RCST/CT,the greater effect on corneal biomechanics and posterior surface elevation.There is no correlation between changes in corneal biomechanics and posterior corneal surface elevation in the range of RCST/CT≥50%. 展开更多
关键词 femtosecond laser-assisted in situ keratomileusis corneal biomechanics posterior corneal surface elevation
下载PDF
Effect of open ultraviolet germicidal irradiation lamps on functionality of excimer lasers used in cornea surgery
8
作者 Jaroslavas Belovickis Aliaksei Kurylenka Vadim Murashko 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第9期1474-1476,共3页
We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate o... We report on the impact of direct ultraviolet germicidal irradiation(UVGI)on reflective optics,used in the excimer laser system Allegretto Eye-Q.The aim of our work was to confirm our hypothesis based on long-rate observations of obtained anomalies in post-operative results that are attributed to degradation of reflective optics upon ultraviolet radiation.The presence of direct UVGI coupled with humidity in the operating environment caused merging anomalies and unwanted post-operative correction values.Ultraviolet-A radiation caused a similar effect on the reflective cover of the mirrors. 展开更多
关键词 ultraviolet radiation excimer lasers post-operative anomalies laser-assisted in situ keratomileusis mirror degradation
下载PDF
应用眼球自旋控制功能的FS-LASIK与SMILE术后角膜高阶像差的比较 被引量:3
9
作者 郑洪玲 朱冉 《医学研究杂志》 2023年第1期168-171,110,共5页
目的比较应用眼球自旋控制功能的飞秒激光辅助准分子激光原位角膜磨镶术(femtosecond laser-assisted laser in situ keratomileusisis,FS-LASIK)与飞秒激光小切口角膜基质透镜取出术(small incision lenticule extraction,SMILE)术后... 目的比较应用眼球自旋控制功能的飞秒激光辅助准分子激光原位角膜磨镶术(femtosecond laser-assisted laser in situ keratomileusisis,FS-LASIK)与飞秒激光小切口角膜基质透镜取出术(small incision lenticule extraction,SMILE)术后角膜前表面高阶像差的变化。方法采用前瞻性非随机对照研究方法,选取2021年4~12月于徐州医科大学附属徐州市立医院行角膜屈光手术的近视患者70例(70眼),所有患者均只纳入右眼,根据患者选择的术式分为FS-LASIK组与SMILE组,每组各35例。分别于术前及术后1、3个月应用Pentacam AXL系统测量角膜前表面6mm区域的高阶像差。结果术后1天裸眼视力(uncorrected visual acuity,UCVA)≥5.0的占比FS-LASIK组为94.30%(33眼),SMILE组为60.00%(21眼),差异有统计学意义(χ^(2)=11.67,P<0.01);两组术后1、3个月UCVA≥5.0的占比比较,差异无统计学意义(P>0.05)。FS-LASIK组术后1天及术后1、3个月等效球镜度数均高于SMILE组,差异均有统计学意义(P均<0.05)。两组术后1、3个月,除SMILE组水平彗差与术前无明显变化,余均较同组术前明显提高,差异有统计学意义(P均<0.05);术后1、3个月,两组垂直彗差及球差组间比较,差异均有统计学意义(P值<0.01)。结论FS-LASIK和SMILE术后垂直彗差、球差及总高阶像差均较术前增加,但应用眼球自旋控制功能的FS-LASIK垂直彗差的绝对值低于SMILE,而球差高于SMILE。 展开更多
关键词 飞秒激光辅助准分子激光原位角膜磨镶术 飞秒激光小切口角膜基质镜取出术 眼球自旋控制 波前像差
下载PDF
角膜地形图引导的飞秒制瓣准分子激光手术治疗近视合并散光患者的效果
10
作者 严若华 黄展宇 +2 位作者 鄢继超 杨旦 吴建斌 《中国民康医学》 2024年第11期43-45,49,共4页
目的:观察角膜地形图引导的飞秒制瓣准分子激光手术(FS-LASIK)治疗近视合并散光患者的效果。方法:选取2018年7月至2023年7月梅州爱尔眼科医院收治的68例(136只眼)近视合并散光患者进行前瞻性研究,按照随机数字表法将其分为对照组和观察... 目的:观察角膜地形图引导的飞秒制瓣准分子激光手术(FS-LASIK)治疗近视合并散光患者的效果。方法:选取2018年7月至2023年7月梅州爱尔眼科医院收治的68例(136只眼)近视合并散光患者进行前瞻性研究,按照随机数字表法将其分为对照组和观察组各34例(68只眼)。对照组实施普通FS-LASIK治疗,观察组实施角膜地形图引导的FS-LASIK治疗。比较两组治疗前后视力[裸眼视力(UCVA)、最佳矫正视力(BCVA)、等效屈光度(SE)]水平、角膜高阶像差指标[总高阶像差(HOA)、彗差(Coma)、球差(SA)]水平、散光矫正指标[成功指数(IOS)、变平指数(FI)、矫正指数(CI)]水平和并发症发生率。结果:术后3个月,两组SE水平均高于术前,且观察组高于对照组,差异有统计学意义(P<0.05);两组BCVA、UCVA水平均低于术前,但组间比较,差异无统计学意义(P>0.05);两组HOA、Coma、SA水平均高于术前,但观察组低于对照组,差异有统计学意义(P<0.05);观察组IS、CI水平均低于对照组,FI水平高于对照组,差异有统计学意义(P<0.05);两组均未发生严重并发症。结论:角膜地形图引导的FS-LASIK治疗近视合并散光患者,可提高等效屈光度,改善散光矫正指标水平,降低角膜高阶像差指标水平,效果优于普通FS-LASIK治疗效果。 展开更多
关键词 角膜地形图 飞秒激光 准分子激光原位角膜磨镶术 近视 散光 等效屈光度
下载PDF
飞秒激光小切口角膜基质透镜取出术和飞秒激光辅助准分子激光原位角膜磨镶术矫治近视的临床效果
11
作者 韩云飞 张立华 +1 位作者 徐贝贝 徐琳琳 《中国社区医师》 2024年第29期39-41,共3页
目的:分析飞秒激光小切口角膜基质透镜取出术(SMILE)和飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)矫治近视的临床效果。方法:选取2022年6月山东滨州沪滨爱尔眼科医院屈光手术科收治的60例(119眼)近视患者作为研究对象,随机分为研... 目的:分析飞秒激光小切口角膜基质透镜取出术(SMILE)和飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)矫治近视的临床效果。方法:选取2022年6月山东滨州沪滨爱尔眼科医院屈光手术科收治的60例(119眼)近视患者作为研究对象,随机分为研究组(30例,59眼)与对照组(30例,60眼)。研究组接受SMILE手术,对照组接受FS-LASIK手术。比较两组手术效果。结果:术后1、3个月,两组裸眼视力高于术前,球镜屈光度、柱镜屈光度、等效球镜度低于术前(P<0.05);两组间比较,无统计学差异(P>0.05)。术后3个月,研究组3 mm瞳孔直径下垂直彗差、球差大于对照组(P<0.05);两组水平彗差无明显变化(P>0.05)。术后3个月,两组总高阶像差无明显变化(P>0.05);两组斯特列尔比、调制传递函数值升高,且研究组大于对照组(P<0.05)。结论:SMILE和FS-LASIK矫治近视的临床效果均较好,能够改善患者视力与屈光度,其中SMILE可能会影响患者角膜高阶像差,但能改善患者全眼高阶像差,提高视觉质量。 展开更多
关键词 飞秒激光小切口角膜基质透镜取出术 飞秒激光辅助准分子激光原位角膜磨镶术 近视
下载PDF
SMILE和FS-LASIK术对高度近视患者术后早期角膜高阶像差的影响 被引量:14
12
作者 王红霞 黄立 胡兆垒 《国际眼科杂志》 CAS 北大核心 2021年第7期1244-1248,共5页
目的:研究飞秒激光小切口角膜基质透镜取出术(SMILE)和飞秒激光辅助的准分子激光原位角膜磨镶术(FS-LASIK)对高度近视患者术后早期角膜高阶像差(HOAs)和视觉质量的影响。方法:以2018-08/2020-08在我院接受角膜屈光手术的高度近视患者102... 目的:研究飞秒激光小切口角膜基质透镜取出术(SMILE)和飞秒激光辅助的准分子激光原位角膜磨镶术(FS-LASIK)对高度近视患者术后早期角膜高阶像差(HOAs)和视觉质量的影响。方法:以2018-08/2020-08在我院接受角膜屈光手术的高度近视患者102例204眼为研究对象进行前瞻性研究,随机分为SMILE组(51例102眼)和FS-LASIK组(51例102眼),比较两组患者术后视力、角膜HOAs和客观视觉质量,分析角膜HOAs与客观视觉质量的相关性。结果:术后1mo时,SMILE组和FS-LASIK组患者等效球镜度数均明显降低(P<0.05),且两组患者术后裸眼视力优于术前最佳矫正视力患者占比无差异(95.1%vs 92.2%,P>0.05);两组患者角膜各高阶像差均明显升高(P<0.05),且SMILE组总球差(SA)、三叶草像差(trefoil)和高阶像差(HOAs)低于FS-LASIK组(均P<0.05);两组患者客观散射指数(OSI)明显升高,MTF截止频率(MTFcutoff)、斯特列尔比(SR)、对比度视力(VA100%、VA20%、VA9%)均明显降低(均P<0.05),且SMILE组OSI低于FS-LASIK组,MTFcutoff和VA9%高于FS-LASIK组(均P<0.05);高度近视患者术后角膜各高阶像差与MTFcutoff均呈负相关性,与OSI均呈正相关性(P<0.05)。结论:SMILE和FS-LASIK术均可有效矫正高度近视,且SMILE术后早期角膜HOAs升高幅度更小,对减轻视觉质量损害具有重要意义。 展开更多
关键词 高度近视 飞秒激光小切口角膜基质透镜取出术 飞秒激光辅助的准分子激光原位角膜磨镶术 角膜高阶相差 视觉质量 早期
下载PDF
角膜波前像差引导FS-LASIK治疗近视合并不同程度散光的疗效观察 被引量:6
13
作者 张杨婧 孙鹏 《国际眼科杂志》 CAS 北大核心 2022年第7期1183-1186,共4页
目的:比较角膜波前像差引导的FS-LASIK手术治疗近视合并不同程度散光患者的术后疗效及角膜高阶像差的变化。方法:回顾性病例研究。选取2020-04/10在昆明爱尔眼科医院初次行角膜波前像差引导的FS-LASIK手术治疗近视合并散光患者133例265... 目的:比较角膜波前像差引导的FS-LASIK手术治疗近视合并不同程度散光患者的术后疗效及角膜高阶像差的变化。方法:回顾性病例研究。选取2020-04/10在昆明爱尔眼科医院初次行角膜波前像差引导的FS-LASIK手术治疗近视合并散光患者133例265眼。根据散光程度分为三组:低散光组:散光度≤1.0D共62例124眼,中散光组:散光度1.25~2.0D共54例107眼,高散光组:散光度≥2.25D共17例34眼。记录患者术前及术后3mo时的视力及屈光度,使用Pentacam三维角膜地形图测量患者角膜,记录角膜6mm直径范围的总高阶像差(均方根)、球差、水平彗差、垂直彗差、水平三叶草差、倾斜三叶草差,观察三组患者术后效果并比较手术前后角膜高阶像差的变化情况。结果:三组患者术后视力的有效性指数均大于1.1,残余屈光度均在±0.30D以内,低散光组残余屈光度较其他两组最少(P<0.05)。术后3mo时三组患者的角膜总高阶像差、球差、垂直彗差较术前均增加(P<0.05)。高散光组术后的球差增量较其他两组最少(P<0.05)。结论:角膜波前像差引导的FS-LASIK手术矫正近视合并不同程度的散光均安全有效,对于高散光患者效果确切,术前散光的严重程度并非术后角膜高阶像差增加的原因。 展开更多
关键词 角膜波前像差引导 飞秒激光辅助制瓣的准分子激光原位角膜磨镶术(fs-lasik) 近视 散光 高阶像差
下载PDF
Femtosecond laser corneal refractive surgery for the correction of high myopic anisometropic amblyopia in juveniles 被引量:4
14
作者 Jing Zhang Ke-Ming Yu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2017年第11期1678-1685,共8页
AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis(FS-LASIK) and small-incision lenticule extraction(SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METH... AIM: To evaluate the effects of femtosecond laser-assisted in situ keratomileusis(FS-LASIK) and small-incision lenticule extraction(SMILE) to correct high myopic anisometropic amblyopia in juvenile patients. METHODS: From November 2013 to January 2015, 33 amblyopic patients with high myopic anisometropic amblyopia were studied. FS-LASIK(30 eyes) or SMILE(3 eyes) was performed in the amblyopic eyes. Visual acuity, refraction, contrast sensitivity, stereoacuity and complications were evaluated. Patients completed followup examinations at 3 d, 1 mo, 3 mo and the last follow-up time(mean 8.17±3.23 mo) after surgery. RESULTS: The mean age at surgery was 9.04±3.04 y(range 6-16 y). The mean spherical equivalent in the amblyopic eyes was significantly decreased from-10.00±2.39 D preoperatively to-0.06±1.06 D at 1 mo,-0.19±1.33 D at 3 mo and-0.60±1.43 D at approximately 8 mo postoperatively(P〈0.05 for all). The mean myopic anisometropia was significantly decreased from-9.45±2.33 D preoperatively to +0.37±1.48 D at 1 mo,-0.46±1.47 D at 3 mo and-0.09±1.83 D at approximately 8 mo(P〈0.05 for all). The logarithm of the minimum angle of resolution(log MAR) for uncorrected and corrected distance visual acuity(UDVA and CDVA, respectively) of the amblyopic eye improved from 1.74±0.35 and 0.98±0.63 preoperatively to 0.45±0.31 and 0.41±0.33 at approximately 8 mo after surgery, respectively. The logM AR CDVA at 3 d, 1, 3 and 8 mo postoperatively improved by means of 1.42, 2.22, 2.96, and 4.39 lines, and a gain of more than two lines accounted for 45%, 50%, 74% and 86% of all patients, respectively. The contrast sensitivity of both amblyopic eyes and dominant eyes at 0.5, 2, 8 cycles perdegree was significantly improved postoperatively(P〈0.05 for all). Of the 33 pediatric patients, no patients had near stereopsis preoperatively and seven patients(21.2%) recovered near stereopsis(400″ to 60″) at approximately 8 mo after surgery. No intraoperative or postoperative complications occurred in any patient.CONCLUSION: FS-LASIK or SMILE can be promising alternative methods to correct high myopic anisometropic amblyopia in juvenile patients who have failed with traditional approaches. 展开更多
关键词 refractive surgery myopic anisometropic amblyopia pediatric patients small-incision lenticule extraction femtosecond laser-assisted in situ keratomileusis
下载PDF
飞秒制瓣联合准分子原位角膜磨镶术与板层刀制瓣LASIK术后临床疗效比较
15
作者 冯伟 《世界复合医学》 2023年第10期20-23,共4页
目的 分析比较飞秒制瓣联合准分子原位角膜磨镶术与板层刀制瓣准分子激光手术(laser-assisted in situ keratomileusis,LASIK)术后临床疗效。方法 回顾性分析2019年1月—2021年12月常州市第三人民医院收治的100例近视患者的临床资料,根... 目的 分析比较飞秒制瓣联合准分子原位角膜磨镶术与板层刀制瓣准分子激光手术(laser-assisted in situ keratomileusis,LASIK)术后临床疗效。方法 回顾性分析2019年1月—2021年12月常州市第三人民医院收治的100例近视患者的临床资料,根据手术方式分为两组,研究组(50例)采取半飞秒准分子激光原位角膜磨镶术,对照组(50例)采取角膜瓣下准分子原位角膜磨镶术,比较两组手术并发症、裸眼视力(uncorrected vision acuity, UCVA)、最佳矫正视力(bese corrected vision acuity, BCVA)、角膜荧光素染色评分以及生活质量评分。结果 研究组手术后并发症率(6.00%)低于对照组的22.00%,差异有统计学意义(χ^(2)=5.316,P=0.021)。研究组UCVA和BCVA均高于对照组,差异有统计学意义(P<0.05)。研究组角膜荧光素染色评分低于对照组,差异有统计学意义(P<0.05)。研究组生活质量评分优于对照组,差异有统计学意义(P<0.05)。结论 临床近视激光手术中,对近视患者行半飞秒准分子激光原位角膜磨镶术,临床效果更为显著。 展开更多
关键词 近视激光手术 半飞秒准分子激光原位角膜磨镶术 裸眼视力 最佳矫正视力
下载PDF
飞秒激光与微型角膜刀制瓣LASIK术后视觉质量比较 被引量:21
16
作者 张晶 郑燕 +1 位作者 刘倩 周跃华 《中华实验眼科杂志》 CAS CSCD 北大核心 2016年第6期527-533,共7页
背景 准分子激光角膜原位磨镶术(LASIK)是目前矫正近视和近视散光的主要手术方式之一,研究表明飞秒激光制瓣LASIK的安全性、精确性及可预测性明显优于微型角膜刀制瓣LASIK,但飞秒激光制瓣LASIK对患者视觉质量的影响仍是关注的焦点. 目... 背景 准分子激光角膜原位磨镶术(LASIK)是目前矫正近视和近视散光的主要手术方式之一,研究表明飞秒激光制瓣LASIK的安全性、精确性及可预测性明显优于微型角膜刀制瓣LASIK,但飞秒激光制瓣LASIK对患者视觉质量的影响仍是关注的焦点. 目的 比较Intralase FS60飞秒激光和Moria M2微型角膜刀制瓣LASIK矫正屈光不正的临床疗效及术后视觉质量. 方法 采用前瞻性非随机临床对照研究方法,纳入2012年3-8月于首都医科大学附属北京同仁医院拟行LASIK治疗近视及近视散光并符合纳入标准的患者共102例204眼.根据自愿的原则将患者分为2个组,各组患者基线特征匹配.飞秒激光制瓣组50例100眼行飞秒激光制瓣的LASIK,微型角膜刀制瓣组52例104眼行微型角膜刀制瓣的LASIK.分别于术前及术后3个月、6个月和1年采用波前像差仪分析6 mm瞳孔下Zernike系数及高阶像差的均方根值,采用Optec 6500视功能测试仪测定暗视及暗视+眩光状态下1.5、3.0、6.0、12.0和18.0 c/d空间频率的对比敏感度(CS).结果 飞秒激光制瓣组术后3个月、6个月和1年裸眼视力达到及超过术前最佳矫正视力(BCVA)者分别占95.1%、94.2%和93.9%,微型角膜刀制瓣组分别为94.2%、93.8%和93.2%.术前、术后3个月和术后1年,飞秒激光制瓣组等效球镜度(SE)分别为(-6.37±2.12)、(-0.26±0.45)和(-0.45±0.51)D,微型角膜刀制瓣组分别为(-6.25±2.05)、(-0.44±0.64)和(-0.35±0.59)D,术后3个月和1年2个组间SE比较差异均无统计学意义(u=l.194、1.429,均P>0.05).术后3个月、6个月及1年飞秒激光制瓣组总高阶像差(RMSh)及各项高阶像差均明显低于微型角膜刀制瓣组(均P<0.05).术后3个月和6个月飞秒激光制瓣组术眼在暗视及暗视+眩光状态下各空间频率的LogCS值均明显优于微型角膜刀制瓣组,差异均有统计学意义(均P<0.05).术后1年,2个组间术眼在暗视状态下1.5 c/d空间频率的LogCS差异无统计学意义(P>0.05),而飞秒激光制瓣组术眼在暗视及暗视+眩光状态下12.0 c/d和18.0 c/d空间频率的LogCS值均明显优于微型角膜刀制瓣组,差异均有统计学意义(均P<0.05). 结论 飞秒激光制瓣的LASIK术后产生的高阶像差低于微型角膜刀制瓣的LASIK,视觉质量优于微型角膜刀制瓣的LASIK. 展开更多
关键词 激光原位角膜磨镶术 准分子激光 近视/手术 像差 对比敏感度 飞秒激光 比较研究
下载PDF
去上皮瓣LASEK与飞秒激光辅助LASIK矫治中低度近视的比较 被引量:11
17
作者 金颖 王雁 +3 位作者 杨坤 王璐 赵金荣 耿维莉 《天津医药》 CAS 北大核心 2018年第9期978-982,共5页
目的比较去上皮瓣准分子激光上皮下角膜磨镶术(LASEK)与飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)治疗中低度近视患者术后的效果。方法选择拟行近视矫正手术的低中度近视患者103例(103眼),LASEK组51例(51眼),FS-LASIK组52例(52眼... 目的比较去上皮瓣准分子激光上皮下角膜磨镶术(LASEK)与飞秒激光辅助准分子激光原位角膜磨镶术(FS-LASIK)治疗中低度近视患者术后的效果。方法选择拟行近视矫正手术的低中度近视患者103例(103眼),LASEK组51例(51眼),FS-LASIK组52例(52眼)。比较2组患者在术前和术后1个月、3个月裸眼视力(UCVA)、最佳矫正视力(BCVA)、残余等效球镜度(SE)、总高阶像差、球差、彗差、三叶草相差等指标的变化。结果在术后1、3个月2组UCVA、BCVA差异均无统计学意义;术后1个月LASEK组SE较FS-LASIK组升高(P<0.05),但术后3个月差异无统计学意义。LASEK组和FS-LASIK组术后1个月、3个月总高阶像差、球差均较术前增加(P<0.05);FS-LASIK组彗差术后1个月较术前增加(P<0.05),术后3个月恢复至术前水平,LASEK组彗差术后1个月、3个月与术前相比差异无统计学意义。FS-LASIK组术后1个月全眼总高阶像差和彗差均较去上皮瓣LASEK组升高(P<0.05);术后3个月2组差异无统计学意义。结论去上皮瓣LASEK术式矫正近视术后早期可达到与FS-LASIK相近水平,尤其适用于低中度近视患者。 展开更多
关键词 近视 准分子激光原位角膜磨镶术 角膜上皮下磨镶术 飞秒激光 视觉质量
下载PDF
氯替泼诺混悬滴眼液对准分子激光角膜屈光术后眼压的影响 被引量:6
18
作者 张庆生 王欣 +3 位作者 王忠海 张绍忠 王林 许文鑫 《中华实验眼科杂志》 CAS CSCD 北大核心 2013年第6期551-554,共4页
背景采用准分子激光角膜屈光手术矫正屈光不正可减少患者对框架眼镜的依赖,其术后抗炎药物使用过程中不良反应的防治一直是临床关注的问题。氯替泼诺混悬滴眼液是糖皮质激素类抗炎药,已广泛用于准分子激光角膜屈光术后,以缓解和减轻... 背景采用准分子激光角膜屈光手术矫正屈光不正可减少患者对框架眼镜的依赖,其术后抗炎药物使用过程中不良反应的防治一直是临床关注的问题。氯替泼诺混悬滴眼液是糖皮质激素类抗炎药,已广泛用于准分子激光角膜屈光术后,以缓解和减轻术眼术后的炎症反应,但其长期应用后对眼压影响的报道较少。目的探讨准分子激光角膜屈光手术后使用质量分数0.5%氯替泼诺混悬滴眼液对眼压的影响。方法采用回顾性病例分析研究设计,收集2011年1月至2012年1月在唐山市眼科医院行准分子激光角膜屈光手术并有完整随访资料的近视患者1552例1552眼,其中行准分子激光角膜原位磨镶术(LASIK)者321眼,行准分子激光前弹力层下角膜原位磨镶术(SBK)者608眼,行飞秒激光制瓣准分子激光角膜原位磨镶术(FS—LASIK)者623眼。所有患者术后均应用0.5%氯替泼诺混悬滴眼液点眼,每日4次,每周递减1次,共1个月。术前及术后1、2、3、4周分别用非接触眼压计测量眼压,并根据眼压升高的幅度分为〈5mmHg(1mmHg=0.133kPa)、5~15mmHg和〉15mmHg三种糖皮质激素反应。术后发现眼压升高及眼压恢复正常1个月时采用海德堡视网膜断层扫描仪进行视盘参数的检测和观察,并进行比较。结果纳入的1552眼中,术后1个月内眼压升高者47眼,其中行LASIK者用药后眼压升高者占3.12%(10/321),行SBK者占3.29%(20/608),行FS—LAStK者占2.73%(17/623),三者间比较差异无统计学意义(x2=1.95,P〉0.05)。停用0.5%氯替泼诺混悬滴眼液或加用降眼压药物治疗后,术眼眼压降至正常水平,仅1眼出现轻度反弹,视力无下降。术后眼压升高与眼压恢复后1个月时,受检眼的盘沿面积分别为(1.65±0.44)mm2和(1.66±0.44)mm2,盘沿容积分别为(0.40±0.09)mm2和(0.39±0.08)mm2,平均神经纤维层厚度分别为(0.28±0.08)mm和(0.29±0.07)mm,差异均无统计学意义(t=0.34、0.81、0.48,P〉0.05)。结论准分子激光角膜屈光手术后使用0.5%氯替泼诺混悬滴眼液进行抗炎治疗导致的眼压升高为可逆性,用药期间应定期监测眼压变化。 展开更多
关键词 氯替泼诺混悬滴眼液 准分子激光角膜屈光手术 准分子激光角膜原位磨镶术 准分子激 光前弹力层下角膜原位磨镶术 飞秒激光制瓣准分子激光角膜原位磨镶术 眼压
下载PDF
FS⁃SBK术、SMILE术、LASIK术对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响 被引量:12
19
作者 张醇 黎明 +3 位作者 应方微 贾惠莉 杨娟 王时娟 《实用医学杂志》 CAS 北大核心 2021年第14期1837-1841,1845,共6页
目的研究飞秒激光制瓣的SBK术(FS⁃SBK术)、小切口飞秒激光基质透镜取出术(SMILE术)、准分子激光原位角膜磨镶术(LASIK术)对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响。方法选取2019年1-6月我院收治的近视散光患者150例,... 目的研究飞秒激光制瓣的SBK术(FS⁃SBK术)、小切口飞秒激光基质透镜取出术(SMILE术)、准分子激光原位角膜磨镶术(LASIK术)对近视及近视散光患者角膜生物力学、中央角膜内皮细胞的影响。方法选取2019年1-6月我院收治的近视散光患者150例,采用分层抽样法将患者分为FS⁃SBK术组、SMILE术组和LASIK术组各50例。FS⁃SBK术组使用FS⁃SBK术治疗,SMILE术组使用SMILE术治疗,LASIK术组使用LASIK术治疗,评价患者角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、视力、屈光度及并发症发生情况。结果SMILE术组患者角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、屈光度、并发症发生率低于FS⁃SBK术组和LASIK术组,视力高于FS⁃SBK术组和LASIK术组,差异有统计学意义(P<0.05)。FS⁃SBK术组和LASIK术组角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、视力、屈光度和并发症发生率比较,差异无统计学意义(P>0.05)。结论与FS⁃SBK术和LASIK术相比,SMILE术可显著改善角膜生物力学指标、中央角膜内皮细胞指标ECD、CV、6A水平、角膜像差、屈光度、并发症发生率,促进患者视力恢复。 展开更多
关键词 飞秒激光制瓣的SBK术 小切口飞秒激光基质透镜取出术 准分子激光原位角膜磨镶术 近视 近视散光
下载PDF
飞秒激光制瓣的准分子激光原位角膜磨镶术与全飞秒激光小切口角膜基质内透镜取出术对屈光不正患者眼表的影响 被引量:14
20
作者 孙广莉 韩文杰 +1 位作者 刘方 苏刚 《眼科新进展》 CAS 北大核心 2021年第4期333-337,共5页
目的比较飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)与全飞秒激光小切口角膜基质内透镜取出术(SMILE)对屈光不正患者眼表的影响。方法选取2018年1月至2019年6月于郑州大学第一附属医院行角膜屈光手术的63例(126眼)屈光不正患者... 目的比较飞秒激光制瓣的准分子激光原位角膜磨镶术(FS-LASIK)与全飞秒激光小切口角膜基质内透镜取出术(SMILE)对屈光不正患者眼表的影响。方法选取2018年1月至2019年6月于郑州大学第一附属医院行角膜屈光手术的63例(126眼)屈光不正患者进行观察。根据患者接受的手术方式不同分为两组,FS-LASIK组31例(62眼),SMILE组32例(64眼),术后随访6个月,观察并收集数据。观察指标包括眼表疾病指数(OSDI)量表评分、角膜荧光素染色评分、泪河高度(TMH)、非侵入式泪膜破裂时间(NIKBUT)、脂质层厚度、睑板腺功能评估得分、眼红指数(HI)。对两组患者各项指标进行统计学分析。结果FS-LASIK组患者术后1周、1个月、6个月OSDI评分较术前均增加,差异均有统计学意义(均为P<0.05);在术后1周时OSDI评分增加最明显。SMILE组患者术后1周、1个月OSDI评分较术前增加,差异均有统计学意义(均为P<0.05)。两组患者术后1周、1个月、6个月OSDI评分相比,差异均有统计学意义(均为P<0.05),FS-LASIK组均高于SMILE组。两组患者术后1周角膜荧光素染色评分均较术前提高,差异均有统计学意义(均为P<0.05);术后1个月、6个月与术前相比,差异均无统计学意义(均为P>0.05)。FS-LASIK组患者术后1周、1个月、6个月TMH与术前相比均减小,差异均有统计学意义(均为P<0.05),且在术后1周减小最为显著。SMILE组患者术后1周、1个月TMH亦均较术前减小(均为P<0.05)。FS-LASIK组患者术后1周、1个月、6个月NIKBUT与术前相比均减小,差异均有统计学意义(均为P<0.05),且在术后1周减小最为显著。SMILE组患者术后1周、1个月、6个月NIKBUT与术前相比均减小,差异均有统计学意义(均为P<0.05)。两组患者术后1周、1个月、6个月NIKBUT相比,差异均有统计学意义(均为P<0.05),FS-LASIK组均小于SMILE组。FS-LASIK组患者术后1周、1个月、6个月脂质层厚度均较术前减小,差异均有统计学意义(均为P<0.05)。SMILE组患者术后1周、1个月脂质层厚度亦均较术前减小,差异均有统计学意义(均为P<0.05)。两组患者术后1周、1个月、6个月睑板腺功能评估得分与术前相比,差异均无统计学意义(均为P>0.05)。FS-LASIK组和SMILE组患者术后1周HI与术前相比均升高,差异均有统计学意义(均为P<0.05)。两组患者术后1周HI相比,差异有统计学意义(P<0.05),FS-LASIK组高于SMILE组。结论FS-LASIK与SMILE均会对患者眼表产生不同程度的影响,但FS-LASIK对术后眼表的影响较SMILE明显,且这种影响作用的时间更长。 展开更多
关键词 飞秒激光制瓣的准分子激光原位角膜磨镶术 全飞秒激光小切口角膜基质内透镜取出术 眼表疾病 干眼
下载PDF
上一页 1 2 3 下一页 到第
使用帮助 返回顶部