Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). Th...Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). The main specific features of fs-PRLIBS are that a lower plasma temperature leads to a low level of continuum and no species are detected from the ambient gas. Furthermore, signals obtained by fs-PRLIBS show a higher stability than those of ns-PRLIBS. However, more elements are detected in the ns-PRLIBS spectra.展开更多
The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphi...The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection.展开更多
In this paper,we investigated the emission spectra of plasmas produced from femtosecond and nanosecond laser ablations at different target temperatures in air.A brass was selected as ablated target of the experiment.T...In this paper,we investigated the emission spectra of plasmas produced from femtosecond and nanosecond laser ablations at different target temperatures in air.A brass was selected as ablated target of the experiment.The results indicated that spectral emission intensity and plasma temperature showed similar trend for femtosecond and nanosecond lasers,and the two parameters were improved by increasing the sample temperature in both cases.Moreover,the temperature of nanosecond laser-excited plasma was higher compared with that of femtosecond laser-excited plasma,and the increase of the plasma temperature in the case of nanosecond laser was more evident.In addition,there was a significant difference in electron density between femtosecond and nanosecond laser-induced plasmas.The electron density for femtosecond laser decreased with increasing the target temperature,while for nanosecond laser,the electron density was almost unchanged at different sample temperatures.展开更多
In this study, a femtosecond laser was focused to ablate brass target and generate plasma emission in air. The influence of lens to sample distance(LTSD) on spectral emission of brass plasma under linearly and circula...In this study, a femtosecond laser was focused to ablate brass target and generate plasma emission in air. The influence of lens to sample distance(LTSD) on spectral emission of brass plasma under linearly and circularly polarized pulses with different pulse energies was investigated. The results indicated that the position with the strongest spectral emission moved toward focusing lens with increasing the energy. At the same laser energy, the line emission under circularly polarized pulse was stronger compared with linearly polarized pulse for different LTSDs. Next, electron temperature and density of the plasma were obtained with Cu(Ⅰ) lines,indicating that the electron temperature and density under circularly polarized pulse were higher compared to that under linearly polarized pulse. Therefore, changing the laser polarization is a simple and effective way to improve the spectral emission intensity of femtosecond laserinduced plasma.展开更多
The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance sp...The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance spectral emission intensity.This work uses a femtosecond laser as the light souuce,since femtosecond laser has many advantages in laser-induced plasma compared with nanosecond laser,meanwhile,the study on femtosecond LIBS with spark discharge is rare.Time-resolved spectroscopy of spark discharge assisted femtosecond LIBS was investigated under different discharge voltages and laser energies.The results showed that the spectral intensity was significantly enhanced by using spark discharge compared with LIBS alone.And,the spectral emission intensity using spark discharge assisted LIBS increased with the increase in the laser energy.In addition,at low laser energy,there was an obvious delay on the discharge time compared with high laser energy,and the discharge time with positive voltage was different from that with negative voltage.展开更多
It is shown that the continuum emission produced by an A1 alloy ablated by femtosecond laser pulses is much more polarized than the characteristic lines of elements. A Glan-Thomson polarizer is used in the laser-induc...It is shown that the continuum emission produced by an A1 alloy ablated by femtosecond laser pulses is much more polarized than the characteristic lines of elements. A Glan-Thomson polarizer is used in the laser-induced breakdown spectroscopy experiment to investigate the polarization effect. The use of the polarizer at its minimal transmission increases the signal-to-noise ratio. The effects of angle of detection, focal position, and pulse energy on the signal-to- noise ratio are also studied.展开更多
Laser-induced breakdown spectroscopy(LIBS) is a good technique for detecting and analyzing material elements due to the plasma emission produced by the high-power laser pulse. Currently, a significant topic of LIBS re...Laser-induced breakdown spectroscopy(LIBS) is a good technique for detecting and analyzing material elements due to the plasma emission produced by the high-power laser pulse. Currently, a significant topic of LIBS research is improving the emission intensity of LIBS. This study investigated the effect of laser-polarization on femtosecond laser-ablated Cu plasma spectra at different sample temperatures. The measured lines under circularly polarized lasers were higher than those under linearly and elliptically polarized lasers. The enhancement effect was evident at higher Cu temperatures when comparing the plasma spectra that have circular and linear polarizations for different target temperatures. To understand the influence of laser-polarization and sample temperature on signal intensity, we calculated the plasma temperature(PT)and electron density(ED). The change in PT and ED was consistent with the change in the atomic lines as the laser polarization was being adjusted. When raising the Cu temperature, the PT increased while the ED decreased. Raising the Cu temperature whilst adjusting the laser-polarization is effective for improving the signal of femtosecond LIBS compared to raising the initial sample temperature alone or only changing the laser polarization.展开更多
In double-pulse laser-induced breakdown spectroscopy(DP-LIBS), the collinear femtosecond double-pulse laser configuration is experimentally investigated with different initial sample temperatures using a Ti:sapphire l...In double-pulse laser-induced breakdown spectroscopy(DP-LIBS), the collinear femtosecond double-pulse laser configuration is experimentally investigated with different initial sample temperatures using a Ti:sapphire laser. The glass sample is ablated to produce the plasma spectroscopy. During the experiment, the detected spectral lines include two Na(I) lines(589.0 nm and 589.6 nm) and one Ca(I) line at the wavelength of 585.7 nm. The emission lines are measured at room temperature(22 ℃) and three higher initial sample temperatures(T_s?=?100 ℃, 200 ℃, and 250 ℃). The inter-pulse delay time ranges from-250 ps to 250 ps.The inter-pulse delay time and the sample temperature strongly influence the spectral intensity,and the spectral intensity can be significantly enhanced by increasing the sample temperature and selecting the optimized inter-pulse time. For the same inter-pulse time of 0 ps(single-pulse LIBS), the enhancement ratio is approximately 2.5 at T_s?=?200 ℃ compared with that obtained at T_s?=?22 ℃. For the same inter-pulse time of 150 ps, the enhancement ratio can be up to 4 at T_s?=?200 ℃ compared with that obtained at T_s?=?22 ℃. The combined enhancement effects of the different initial sample temperatures and the double-pulse configuration in femtosecond LIBS are much stronger than that of the different initial sample temperatures or the double-pulse configuration only.展开更多
The influence of the target temperature on the molecular emission of femtosecond laser-induced breakdown spectroscopy(LIBS) was investigated experimentally. An Al target was ablated to produce laser-induced plasma. Th...The influence of the target temperature on the molecular emission of femtosecond laser-induced breakdown spectroscopy(LIBS) was investigated experimentally. An Al target was ablated to produce laser-induced plasma. The Al target was uniformly heated to a maximum of 250℃. The measured molecular emission was AlO(△ν=0) from the femtosecond LIBS of the Al target.The measurements indicated that the molecular emission of AlO increased as the temperature of the Al target increased. In addition, a two-temperature model was used to simulate the evolution of the electron and lattice temperature of the Al target with different initial temperatures. The simulated results showed that the electron and lattice temperatures of Al irradiated by the femtosecond laser increased as the initial temperature of the Al target increased;also, the simulated ablated depth increased. Therefore, an increase in the initial Al target temperature resulted in an enhancement in the spectral signal of AlO from the femtosecond LIBS of Al,which was directly related to the increase in the size of the ablated crater. The study suggested that increasing the temperature of the target improves the intensity of molecular emission in femtosecond LIBS.展开更多
Spectral intensity,electron temperature and density of laser-induced plasma(LIP) are important parameters for affecting sensitivity of laser-induced breakdown spectroscopy(LIBS).Increasing target temperature is an eas...Spectral intensity,electron temperature and density of laser-induced plasma(LIP) are important parameters for affecting sensitivity of laser-induced breakdown spectroscopy(LIBS).Increasing target temperature is an easy and feasible method to improve the sensitivity.In this paper,a brass target in a temperature range from 25℃ to 200℃ was ablated to generate the LIP using femtosecond pulse.Time-resolved spectral emission of the femtosecond LIBS was measured under different target temperatures.The results showed that,compared with the experimental condition of 25℃,the spectral intensity of the femtosecond LIP was enhanced with more temperature target.In addition,the electron temperature and density were calculated by Boltzmann equation and Stark broadening,indicating that the changes in the electron temperature and density of femtosecond LIP with the increase of the target temperature were different from each other.By increasing the target temperature,the electron temperature increased while the electron density decreased.Therefore,in femtosecond LIBS,a hightemperature and low-density plasma with high emission can be generated by increasing the target temperature.The increase in the target temperature can improve the resolution and sensitivity of femtosecond LIBS.展开更多
Femtosecond laser-induced breakdown spectroscopy (fs-LIBS) is employed to analyze the element content in poplar tree leaves from four representative locations in Changchun City (Jingyue National Forest Park,JYP),Chang...Femtosecond laser-induced breakdown spectroscopy (fs-LIBS) is employed to analyze the element content in poplar tree leaves from four representative locations in Changchun City (Jingyue National Forest Park,JYP),Changchun University of Science and Technology (CUST),Casting Factory (CF) and Forging Factory (FF) of First Automobile Works (FAW) under identical experimental conditions.Those elements of N,P,K,Ca,Fe,Ti,Mn and Na are identified in the poplar tree leaves from the recorded spectrogram and the elemental content in the leaves is further obtained by applying free calibration method to the spectrogram.Our results show that the elements Ca and Fe in the poplar tree leaves from the CF area have the highest concentration in the four locations,which is a factor of 2.05 and 1.66 respectively to those of JYP.This experiment demon-strates that fs-LIBS can be utilized to analyze element content in a sample and find new applications in the environmental detection.展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11211120156, 11274053, 11074027, 61178022, and 60978014)the Science and Technology Department of Jilin Province, China (Grant Nos. 20100521, 20100168, and 20111812)the SRF for ROCS, SEM
文摘Aluminum samples have been analyzed by femtosecond polarization-resolved laser-induced breakdown spectroscopy (fs-PRLIBS). We compare the obtained spectra with those obtained from nanosecond PRLIBS (ns-PRLIBS). The main specific features of fs-PRLIBS are that a lower plasma temperature leads to a low level of continuum and no species are detected from the ambient gas. Furthermore, signals obtained by fs-PRLIBS show a higher stability than those of ns-PRLIBS. However, more elements are detected in the ns-PRLIBS spectra.
基金supported by the Russian Science Foundation(agreement#14-50-00034)(measurements of limit of detection)Russian Foundation for Basic Research(NK 15-32-20878/15)obtained in the frame of "Organization of Scientific Research"in the Far Eastern Federal University supported by Ministry of Education and Science of Russian Federation
文摘The influence of the energy of femtosecond laser pulses on the intensity of Fe I (371.99 nm) emission line and the continuous spectrum of the plasma generated on the surface of Fe^3+ water solution by a Ti: sapphire laser radiation with pulse duration 〈45 fs and energies up to 7 mJ is determined. A calibration curve was obtained for Fe3+ concentration range from 0.5 g/L to the limit of detection in water solution, and its saturation was detected for concentrations above 0.25 g/L, which is ascribed to self-absorption. The 3σ- limit of detection obtained for Fe in water solution is 2.6 mg/L in the case of 7 mJ laser pulse energy. It is found that an increase of laser pulse energy insignificantly affects on LOD in the time-resolved LIBS and leads to a slight improvement of the limit of detection.
基金the support by the Scientific and Technological Research Project of the Education Department of Jilin Province, China (No. JJKH20200937KJ)National Natural Science Foundation of China (Nos. 11674128, 11674124 and 11974138)
文摘In this paper,we investigated the emission spectra of plasmas produced from femtosecond and nanosecond laser ablations at different target temperatures in air.A brass was selected as ablated target of the experiment.The results indicated that spectral emission intensity and plasma temperature showed similar trend for femtosecond and nanosecond lasers,and the two parameters were improved by increasing the sample temperature in both cases.Moreover,the temperature of nanosecond laser-excited plasma was higher compared with that of femtosecond laser-excited plasma,and the increase of the plasma temperature in the case of nanosecond laser was more evident.In addition,there was a significant difference in electron density between femtosecond and nanosecond laser-induced plasmas.The electron density for femtosecond laser decreased with increasing the target temperature,while for nanosecond laser,the electron density was almost unchanged at different sample temperatures.
基金support by National Natural Science Foundation of China(Nos.11674128,11674124 and 11974138)Scientific and Technological Research Project of the Education Department of Jilin Province in China(No.JJKH20200937KJ).
文摘In this study, a femtosecond laser was focused to ablate brass target and generate plasma emission in air. The influence of lens to sample distance(LTSD) on spectral emission of brass plasma under linearly and circularly polarized pulses with different pulse energies was investigated. The results indicated that the position with the strongest spectral emission moved toward focusing lens with increasing the energy. At the same laser energy, the line emission under circularly polarized pulse was stronger compared with linearly polarized pulse for different LTSDs. Next, electron temperature and density of the plasma were obtained with Cu(Ⅰ) lines,indicating that the electron temperature and density under circularly polarized pulse were higher compared to that under linearly polarized pulse. Therefore, changing the laser polarization is a simple and effective way to improve the spectral emission intensity of femtosecond laserinduced plasma.
基金National Natural Science Foundation of China (Nos. 11674128, and 11674124)Jilin Province Scientific and Technological Development Program, China (No. 20170101063JC).
文摘The combination of spark discharge and laser-induced breakdown spectroscopy (LIBS) is called spark discharge assisted LIBS.It works under laser-plasma triggered spark discharge mode,and shows its ability to enhance spectral emission intensity.This work uses a femtosecond laser as the light souuce,since femtosecond laser has many advantages in laser-induced plasma compared with nanosecond laser,meanwhile,the study on femtosecond LIBS with spark discharge is rare.Time-resolved spectroscopy of spark discharge assisted femtosecond LIBS was investigated under different discharge voltages and laser energies.The results showed that the spectral intensity was significantly enhanced by using spark discharge compared with LIBS alone.And,the spectral emission intensity using spark discharge assisted LIBS increased with the increase in the laser energy.In addition,at low laser energy,there was an obvious delay on the discharge time compared with high laser energy,and the discharge time with positive voltage was different from that with negative voltage.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 60978014, 11074027, and 61178022)the Funds from Jilin Provincial Science and Technology Department, China (Grant Nos. 20100521, 20100168, and 20111812)+1 种基金the Science and Technology Division of Changchun City, China (Grant No. 09GH01)the Scientific Research Foundation for the Returned Overseas Chinese Scholars of State Education Ministry, China
文摘It is shown that the continuum emission produced by an A1 alloy ablated by femtosecond laser pulses is much more polarized than the characteristic lines of elements. A Glan-Thomson polarizer is used in the laser-induced breakdown spectroscopy experiment to investigate the polarization effect. The use of the polarizer at its minimal transmission increases the signal-to-noise ratio. The effects of angle of detection, focal position, and pulse energy on the signal-to- noise ratio are also studied.
基金Project supported by the National Key Research and Development Program of China (Grant No. 2019YFA0307701)the National Natural Science Foundation of China (Grant Nos. 11974138, 11674128, and 11674124)。
文摘Laser-induced breakdown spectroscopy(LIBS) is a good technique for detecting and analyzing material elements due to the plasma emission produced by the high-power laser pulse. Currently, a significant topic of LIBS research is improving the emission intensity of LIBS. This study investigated the effect of laser-polarization on femtosecond laser-ablated Cu plasma spectra at different sample temperatures. The measured lines under circularly polarized lasers were higher than those under linearly and elliptically polarized lasers. The enhancement effect was evident at higher Cu temperatures when comparing the plasma spectra that have circular and linear polarizations for different target temperatures. To understand the influence of laser-polarization and sample temperature on signal intensity, we calculated the plasma temperature(PT)and electron density(ED). The change in PT and ED was consistent with the change in the atomic lines as the laser polarization was being adjusted. When raising the Cu temperature, the PT increased while the ED decreased. Raising the Cu temperature whilst adjusting the laser-polarization is effective for improving the signal of femtosecond LIBS compared to raising the initial sample temperature alone or only changing the laser polarization.
基金support by National Natural Science Foundation of China (Grant Nos. 11674128, 11504129, and 11674124)Jilin Province Scientific and Technological Development Program, China (Grant No. 20170101063JC)Fundamental Research Project of Chinese State Key Laboratory of Laser Interaction with Matter (Grant No. SKLLIM1605)
文摘In double-pulse laser-induced breakdown spectroscopy(DP-LIBS), the collinear femtosecond double-pulse laser configuration is experimentally investigated with different initial sample temperatures using a Ti:sapphire laser. The glass sample is ablated to produce the plasma spectroscopy. During the experiment, the detected spectral lines include two Na(I) lines(589.0 nm and 589.6 nm) and one Ca(I) line at the wavelength of 585.7 nm. The emission lines are measured at room temperature(22 ℃) and three higher initial sample temperatures(T_s?=?100 ℃, 200 ℃, and 250 ℃). The inter-pulse delay time ranges from-250 ps to 250 ps.The inter-pulse delay time and the sample temperature strongly influence the spectral intensity,and the spectral intensity can be significantly enhanced by increasing the sample temperature and selecting the optimized inter-pulse time. For the same inter-pulse time of 0 ps(single-pulse LIBS), the enhancement ratio is approximately 2.5 at T_s?=?200 ℃ compared with that obtained at T_s?=?22 ℃. For the same inter-pulse time of 150 ps, the enhancement ratio can be up to 4 at T_s?=?200 ℃ compared with that obtained at T_s?=?22 ℃. The combined enhancement effects of the different initial sample temperatures and the double-pulse configuration in femtosecond LIBS are much stronger than that of the different initial sample temperatures or the double-pulse configuration only.
基金support by Scientific and Technological Research Project of the Education Department of Jilin Province,China(No.JJKH20200937KJ)National Natural Science Foundation of China(Nos.11674128,11674124,and 11974138).
文摘The influence of the target temperature on the molecular emission of femtosecond laser-induced breakdown spectroscopy(LIBS) was investigated experimentally. An Al target was ablated to produce laser-induced plasma. The Al target was uniformly heated to a maximum of 250℃. The measured molecular emission was AlO(△ν=0) from the femtosecond LIBS of the Al target.The measurements indicated that the molecular emission of AlO increased as the temperature of the Al target increased. In addition, a two-temperature model was used to simulate the evolution of the electron and lattice temperature of the Al target with different initial temperatures. The simulated results showed that the electron and lattice temperatures of Al irradiated by the femtosecond laser increased as the initial temperature of the Al target increased;also, the simulated ablated depth increased. Therefore, an increase in the initial Al target temperature resulted in an enhancement in the spectral signal of AlO from the femtosecond LIBS of Al,which was directly related to the increase in the size of the ablated crater. The study suggested that increasing the temperature of the target improves the intensity of molecular emission in femtosecond LIBS.
基金support by National Natural Science Foundation of China (Nos. 11674128, 11674124 and 11974138)the Jilin Province Scientific and Technological Development Program, China (No. 20170101063JC)。
文摘Spectral intensity,electron temperature and density of laser-induced plasma(LIP) are important parameters for affecting sensitivity of laser-induced breakdown spectroscopy(LIBS).Increasing target temperature is an easy and feasible method to improve the sensitivity.In this paper,a brass target in a temperature range from 25℃ to 200℃ was ablated to generate the LIP using femtosecond pulse.Time-resolved spectral emission of the femtosecond LIBS was measured under different target temperatures.The results showed that,compared with the experimental condition of 25℃,the spectral intensity of the femtosecond LIP was enhanced with more temperature target.In addition,the electron temperature and density were calculated by Boltzmann equation and Stark broadening,indicating that the changes in the electron temperature and density of femtosecond LIP with the increase of the target temperature were different from each other.By increasing the target temperature,the electron temperature increased while the electron density decreased.Therefore,in femtosecond LIBS,a hightemperature and low-density plasma with high emission can be generated by increasing the target temperature.The increase in the target temperature can improve the resolution and sensitivity of femtosecond LIBS.
基金supported by the National Natural Science Foundation of China (Grant Nos. 60978014 and 11074027)the Funds from Science & Technology Department of Jilin Province (Grant Nos. 20090523, 20100521 and 20100168)+1 种基金the Fund from Science & Technology Department of Changchun City (Grant No. 09GH01)the Fund from Education Department of Jilin Province (2009 (40)) (Grant No. 9140c150302110c1501)
文摘Femtosecond laser-induced breakdown spectroscopy (fs-LIBS) is employed to analyze the element content in poplar tree leaves from four representative locations in Changchun City (Jingyue National Forest Park,JYP),Changchun University of Science and Technology (CUST),Casting Factory (CF) and Forging Factory (FF) of First Automobile Works (FAW) under identical experimental conditions.Those elements of N,P,K,Ca,Fe,Ti,Mn and Na are identified in the poplar tree leaves from the recorded spectrogram and the elemental content in the leaves is further obtained by applying free calibration method to the spectrogram.Our results show that the elements Ca and Fe in the poplar tree leaves from the CF area have the highest concentration in the four locations,which is a factor of 2.05 and 1.66 respectively to those of JYP.This experiment demon-strates that fs-LIBS can be utilized to analyze element content in a sample and find new applications in the environmental detection.