期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Custom Made Fenestrated Stent Graft Collapse after Thoracic Endovascular Aortic Repair: A Case Report
1
作者 Yasuhiko Kobayashi Mitsugu Fukuda +2 位作者 Shoji Sakaguchi Yoshihisa Nakao Kiyoshi Nishimine 《Case Reports in Clinical Medicine》 2023年第8期299-305,共7页
We present a case of stent graft collapse after performing thoracic endovascular aortic repair with a custom-made fenestrated stent graft. The patient was a 70-year-old woman with an asymptomatic aneurysm of the dista... We present a case of stent graft collapse after performing thoracic endovascular aortic repair with a custom-made fenestrated stent graft. The patient was a 70-year-old woman with an asymptomatic aneurysm of the distal aortic arch, and thoracic endovascular aortic repair was performed. The patient showed a blood pressure difference between the left arm and the right arm on postoperative day (POD) 17 prompting the performance of a chest computed tomography scan which revealed stent graft collapse. She then underwent staged debranching of thoracic endovascular aortic repair. Stent graft collapse is a rare but well-described complication of thoracic endovascular repair. Therefore, patients who undergo such a procedure should be carefully monitored for signs and symptoms, which suggest the possibility of stent collapse. 展开更多
关键词 Thoracic Endovascular Aortic Repair COLLAPSE Custom Made fenestrated stent graft Bird-Beak Deformity
下载PDF
Optimization of fenestrated technique in application to aortic aneurysms with an attached branch
2
作者 Li Zhongyou Chen Chong +2 位作者 Chen Yu Wang Guanshi Jiang Wentao 《Medicine in Novel Technology and Devices》 2020年第3期1-7,共7页
Background:The fenestrated stent technique has been developed for the treatment of aneurysms with branches.However,the hole size and type,which are the key factors for optimal treatment outcomes,are still controversia... Background:The fenestrated stent technique has been developed for the treatment of aneurysms with branches.However,the hole size and type,which are the key factors for optimal treatment outcomes,are still controversial in clinical application.Therefore,a hemodynamics investigation in terms of the size and type of the hole was performed with the objective of providing evidence for optimization of this technique.Method:Six cases were modeled for comparison:cases 1 and 2 corresponded to suprarenal aortic aneurysm(SRAA)models with no stent and a multilayer stent(MS),respectively;cases 3–6 represented the SRAA models treated with fenestrated stent grafts(FSGs)including a small-sized hole(SSH,3 mm),middle-sized hole(MSH,6 mm),large-sized hole(LSH,9 mm),and multiple holes(MH,which included the features of both the MS and stent graft,6 mm),respectively.The total stent area in cases 4 and 6 was equal to the cross-section of the branch.Results:As opposed to cases 1 and 2,the pressure on the aneurysmal wall reduced more significantly with FSG intervention(cases 3–6),and the area of low wall shear stress(WSS)on the aneurysmal wall was unexpectedly large in case 5 owing to jet flow deflection.The branch flux increased with the increase of the hole size,and normal blood flow in the branch was only observed in case 5.Interestingly,the weakest jet flow was found in case 5.Conclusion:Our findings indicate that the diameter of the hole should be slightly larger than that of the branch to achieve better aneurysm isolation and preserve branch patency. 展开更多
关键词 Aortic aneurysm Branch fenestrated stent graft HOLE Numerical simulation HEMODYNAMICS
原文传递
上一页 1 下一页 到第