Objective: To determine the value of fetal fibronectin (FFN), cervical length (CL) measurement and their combination as binary predictors for preterm birth (PB) in women with preterm labour (PTL) between 24 + 0 and 34...Objective: To determine the value of fetal fibronectin (FFN), cervical length (CL) measurement and their combination as binary predictors for preterm birth (PB) in women with preterm labour (PTL) between 24 + 0 and 34 + 0 weeks. Methods: One hundred fifty-nine patients with signs of PTL (singleton pregnancies (SP) = 125, twin pregnancies (TP) = 34) were evaluated in a retrospective study. Inclusion criteria were contractions > 4/20 min, intact membranes, no bleeding. The cut-off was ≥50 ng/ml for FFN and ≤20 mm for CL measured by transvaginal ultrasound. The primary outcome variable was delivery within 7 days from admission. Results: We evaluated 125 SPs and 34 TPs. In SPs, both methods had a sensitivity of 80%;the specificity was 82% for FFN, and 50% for CL. For the combination of both tests sensitivity was 80% and specificity 88%. In TPs, the sensitivity of both tests was lower (FFN 33%, CL 67%) but the combination of both tests represented the highest result for specificity (77% compared to 68% for FFN alone and 32% for CL alone). Conclusion: The combination of FFN and CL in PTL results in a significant higher specificity in SPs. In TPs the performance of the tests is less accurate.展开更多
In order to evaluate the predictive value of maternal plasma fibronectin (FN) concentration at 24-34 weeks on fetal intrauterine growth retardation (IUGR), a prospective double-blinded study was performed. The materna...In order to evaluate the predictive value of maternal plasma fibronectin (FN) concentration at 24-34 weeks on fetal intrauterine growth retardation (IUGR), a prospective double-blinded study was performed. The maternal plasma FN concentrations were measured by using a rate nephelometric procedure in the 130 initial normal nulliparous pregnant woman at 24-34 gestational weeks. The outcome of pregnancies and birth weight of their infants were followed up. IUGR was defined as that the birth weight was less than the 10th percentile for gestational age. The receiver operating characteristic curves and predictive values of FN predicting on outcome of pregnancy with IUGR were analyzed. The results showed that: (1) In a cohort of 130 initially normal nulliparous pregnant women, IUGR occurred in 14 cases during the follow-up; (2) The plasma FN levels in the women with IUGR (467.58±104.43 mg/L) were significantly higher than in the normal control group (299.44±105.55 mg/L, P<0.01). However, there was no significant difference in the mean maternal age, gravidity, sampling gestational ages, delivering gestational ages between the two groups (P>0.05); (3) The areas under ROC curve for predicting the outcome of pregnancy in IUGR was 0.893; (4) At the cut point of 475 mg/L FN level, the sensitivity, specificity, positive predictive value, negative predictive value and Kappa index for predicting the outcomes of pregnancy in IUGR were 57.14 %, 95.69 %, 61.54 %, 94.87 %, 0.5455 respectively. It was concluded that the maternal plasma FN might be used as an earlier predictor for screening of IUGR.展开更多
文摘Objective: To determine the value of fetal fibronectin (FFN), cervical length (CL) measurement and their combination as binary predictors for preterm birth (PB) in women with preterm labour (PTL) between 24 + 0 and 34 + 0 weeks. Methods: One hundred fifty-nine patients with signs of PTL (singleton pregnancies (SP) = 125, twin pregnancies (TP) = 34) were evaluated in a retrospective study. Inclusion criteria were contractions > 4/20 min, intact membranes, no bleeding. The cut-off was ≥50 ng/ml for FFN and ≤20 mm for CL measured by transvaginal ultrasound. The primary outcome variable was delivery within 7 days from admission. Results: We evaluated 125 SPs and 34 TPs. In SPs, both methods had a sensitivity of 80%;the specificity was 82% for FFN, and 50% for CL. For the combination of both tests sensitivity was 80% and specificity 88%. In TPs, the sensitivity of both tests was lower (FFN 33%, CL 67%) but the combination of both tests represented the highest result for specificity (77% compared to 68% for FFN alone and 32% for CL alone). Conclusion: The combination of FFN and CL in PTL results in a significant higher specificity in SPs. In TPs the performance of the tests is less accurate.
文摘In order to evaluate the predictive value of maternal plasma fibronectin (FN) concentration at 24-34 weeks on fetal intrauterine growth retardation (IUGR), a prospective double-blinded study was performed. The maternal plasma FN concentrations were measured by using a rate nephelometric procedure in the 130 initial normal nulliparous pregnant woman at 24-34 gestational weeks. The outcome of pregnancies and birth weight of their infants were followed up. IUGR was defined as that the birth weight was less than the 10th percentile for gestational age. The receiver operating characteristic curves and predictive values of FN predicting on outcome of pregnancy with IUGR were analyzed. The results showed that: (1) In a cohort of 130 initially normal nulliparous pregnant women, IUGR occurred in 14 cases during the follow-up; (2) The plasma FN levels in the women with IUGR (467.58±104.43 mg/L) were significantly higher than in the normal control group (299.44±105.55 mg/L, P<0.01). However, there was no significant difference in the mean maternal age, gravidity, sampling gestational ages, delivering gestational ages between the two groups (P>0.05); (3) The areas under ROC curve for predicting the outcome of pregnancy in IUGR was 0.893; (4) At the cut point of 475 mg/L FN level, the sensitivity, specificity, positive predictive value, negative predictive value and Kappa index for predicting the outcomes of pregnancy in IUGR were 57.14 %, 95.69 %, 61.54 %, 94.87 %, 0.5455 respectively. It was concluded that the maternal plasma FN might be used as an earlier predictor for screening of IUGR.