期刊文献+
共找到200篇文章
< 1 2 10 >
每页显示 20 50 100
Study on Refraction Index Sensors Using Fiber Grating F-P Cavity
1
作者 MAO Kai, QU Li, SU Xuemei (College of Physics, Jilin University, Changchun 130023, CHN) 《Semiconductor Photonics and Technology》 CAS 2010年第4期146-149,166,共5页
In this paper, the reflective spectra of a refraction index sensor were analyzed based on fiber grating F-P cavity. The sensor was constituted by two identical fiber gratings. Compared with the refraction index sensor... In this paper, the reflective spectra of a refraction index sensor were analyzed based on fiber grating F-P cavity. The sensor was constituted by two identical fiber gratings. Compared with the refraction index sensor using one fiber grating, the fiber grating F-P cavity sensor has narrower resonant peak and it can be used for more accurate measurement. The resonant peaks in the reflective spectra of the sensor are changed with small changes of the refraction index of the measured chemical liquids or cell samples. So it has potential applications in biology and chemistry. 展开更多
关键词 sensor fiber BRAGG GRATING F-P cavity MATRIX EQUATION
下载PDF
Application of the Spectrum Peak Positioning Technology Based on BP Neural Network in Demodulation of Cavity Length of EFPI Fiber Optical Sensor
2
作者 Mengran Zhou Mengya Nie 《Journal of Computer and Communications》 2013年第7期67-71,共5页
An Extrinsic Fabry-Perot Interferometric (EFPI) fiber optical sensor system is an online testing system for the gas density. The system achieves the measurement of gas density information mainly by demodulating the ca... An Extrinsic Fabry-Perot Interferometric (EFPI) fiber optical sensor system is an online testing system for the gas density. The system achieves the measurement of gas density information mainly by demodulating the cavity length of EF- PI fiber optical sensor. There are many ways to achieve the demodulation of the cavity length. For shortcomings of the big intensity demodulation error and complex structure of phase demodulation, this paper proposes that BP neural net-work is used to locate the special peak points in normalized interference spectrum and combining the advantages of the unimodal and bimodal measurement achieves the demodulation of the cavity length. Through online simulation and actual measurement, the results show that the peak positioning technology based on BP neural network can not only achieve high-precision demodulation of the cavity length, but also achieve an absolute measurement of cavity length in large dynamic range. 展开更多
关键词 EFPI fiber Optical sensor The DEMODULATION of cavity Length BP NEURAL Network The PEAK POSITIONING Technology
下载PDF
An Ultraviolet Fiber Fabry-Perot Cavity for Florescence Collection of Trapped Ions
3
作者 周坤 崔金明 +10 位作者 黄运锋 王钊 钱忠华 伍启明 王健 贺冉 吕为民 胡长康 韩永建 李传锋 郭光灿 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第1期40-43,共4页
We demonstrate a fiber Fabry-Pérot cavity in the ultraviolet range, which covers the florescence wavelength for the <sup>2</sup>P to <sup>2</sup>S transition of Yb and is designed in the b... We demonstrate a fiber Fabry-Pérot cavity in the ultraviolet range, which covers the florescence wavelength for the <sup>2</sup>P to <sup>2</sup>S transition of Yb and is designed in the bad cavity limit for florescence collection. Benefiting from both the small cavity mode volume and the large atom dipole, a cavity with moderate finesse and high transmission still supports a good cooperativity, which is made and tested in experiment. Based on the measured experimental parameters, simulation performed on the cavity and ion shows a Purcell factor better than 2.5 and a single-mode fiber collection efficiency over 10%. This technology can support ultra-bright single photon sources based on trapped ions and can provide the possibility to link remote atoms as a quantum network. 展开更多
关键词 An Ultraviolet fiber fabry-perot cavity for Florescence Collection of Trapped Ions
下载PDF
Ultrasonic signal detection based on Fabry–Perot cavity sensor 被引量:1
4
作者 Wu Yang Chonglei Zhang +1 位作者 Jiaqi Zeng Wei Song 《Visual Computing for Industry,Biomedicine,and Art》 EI 2021年第1期70-75,共6页
Acoustic/ultrasonic sensors are devices that can convert mechanical energy into electrical signals.The Fabry–Perot cavity is processed on the end face of the double-clad fiber by a two-photon three-dimensional lithog... Acoustic/ultrasonic sensors are devices that can convert mechanical energy into electrical signals.The Fabry–Perot cavity is processed on the end face of the double-clad fiber by a two-photon three-dimensional lithography machine.In this study,the outer diameter of the core cladding was 250μm,the diameter of the core was 9μm,and the microcavity sensing unit was only 30μm.It could measure ultrasonic signals with high precision.The characteristics of the proposed ultrasonic sensor were investigated,and its feasibility was proven through experiments.Its design has a small size and can replace a larger ultrasonic detector device for photoacoustic signal detection.The sensor is applicable to the field of biomedical information technology,including medical diagnosis,photoacoustic endoscopy,and photoacoustic imaging. 展开更多
关键词 fabry-perot microcavity Double-clad fiber Acoustic sensor Endoscopic photoacoustic imaging Two-photon 3D lithography machine Full-optical detection
下载PDF
A Smart Graded-index Multimode Fiber Based Sensor Unit for Multi-parameter Sensing Applications
5
作者 Shuo Fang Baoyong Li +3 位作者 Dawei Song Jianzhong Zhang Weimin Sun Libo Yuan 《Optics and Photonics Journal》 2013年第2期265-267,共3页
We demonstrate a smart optical fiber sensor unit to realize a multi-parameter sensing, including temperature, curvature and strain or displacement. The sensor unit is composed of a Bragg grating in graded-index multim... We demonstrate a smart optical fiber sensor unit to realize a multi-parameter sensing, including temperature, curvature and strain or displacement. The sensor unit is composed of a Bragg grating in graded-index multimode fiber and a Fizeau cavity. 展开更多
关键词 fiber OPTIC sensor fiber BRAGG Grating fiber Fizeau cavity
下载PDF
Miniaturized Fiber-Optic Fabry-Perot Interferometer for Highly Sensitive Refractive Index Measurement
6
作者 Ming Deng Tao Zhu +1 位作者 Yun-Jiang Rao Hong Li 《Journal of Electronic Science and Technology of China》 2008年第4期365-368,共4页
This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including... This paper presents a novel miniaturized fiber-optic Fabry-Peort interferometer (FPI) for highly sensitive refractive index measurement. This device was tested for the refractive indices of various liquids including acetone and ethanol at room temperature. The sensitivity for measurement of refractive index change of ethanol is 1138 nm/RIU at the wavelength of 1550 nm. In addition, the sensor fabrication is simple including only cleaving, splicing, and etching. The signal is stable with high visibility. Therefore, it provides a valuable tool in biological and chemical applications. 展开更多
关键词 fiber optic sensors fabry-perot miniature sensor photonic crystal fiber refractive indexmeasurement.
下载PDF
Mesa Diaphragm-Based Fabry-Perot Optical MEMS Pressure Sensor
7
作者 Yi-Xian Ge Ming Wang Hai-Tao Yan 《Journal of Electronic Science and Technology of China》 2008年第4期466-469,共4页
An optical micro electron mechanical system (MEMS) pressure sensor with a mesa membrane is presented. The operating principle of the MEMS pressure sensor is expatiated by the Fabry-Perot (F-P) interference and the... An optical micro electron mechanical system (MEMS) pressure sensor with a mesa membrane is presented. The operating principle of the MEMS pressure sensor is expatiated by the Fabry-Perot (F-P) interference and the relation between deflection and pressure is analyzed. Both the mechanical model of the mesa structure diaphragm and the signal averaging effect is validated by simulation, which declares that the mesa structure diaphragm is superior to the planar one on the parallelism and can reduce the signal averaging effect. Experimental results demonstrate that the mesa structure sensor has a reasonable linearity and sensitivity. 展开更多
关键词 fabry-perot interference microelectron mechanical system mesa structure optical fiber sensor parallelism.
下载PDF
基于光纤传感的带式输送机张力检测技术
8
作者 苗长云 张豫飞 《天津工业大学学报》 CAS 北大核心 2024年第4期67-74,共8页
针对目前带式输送机张力检测存在易损坏及准确性和可靠性差的问题,提出了一种基于光纤传感的带式输送机的张力检测方法。将法珀腔传感头置于带式输送机张紧装置的液压回路中,液压回路的压力使法珀腔传感头的硅膜片产生形变,引起法珀腔... 针对目前带式输送机张力检测存在易损坏及准确性和可靠性差的问题,提出了一种基于光纤传感的带式输送机的张力检测方法。将法珀腔传感头置于带式输送机张紧装置的液压回路中,液压回路的压力使法珀腔传感头的硅膜片产生形变,引起法珀腔传感头反射光变化;光电解调器光路接收法珀腔传感头的反射光后,经光路解调后得到反射光谱,通过光电解调器电路的光电转换、处理、分析后,得到反射光光谱的自由光谱范围,再根据油缸内部面积计算出带式输送机张力,实现了带式输送机张力检测。根据双干涉效应原理设计了法珀腔传感头,采用Jetson Nano嵌入式系统开发板设计了光电解调器硬件,采用Python语言设计了光电解调器软件,并进行了实验研究。实验结果表明:该方法能够实现带式输送机张力检测,压力测量范围为0~25 MPa,灵敏度为0.148 nm/MPa,测量精度为0.1%,不易损坏,抗干扰性好,准确性和可靠性高。 展开更多
关键词 光纤传感器 带式输送机 张力检测 张紧油缸 法珀腔传感头 光电解调器
下载PDF
基于银膜的自准直光纤法布里-珀罗腔设计及声源定位研究
9
作者 郭一霖 李一豪 +6 位作者 罗彬彬 邹雪 吴德操 李恭烨 曹盛 石胜辉 赵明富 《光子学报》 EI CAS CSCD 北大核心 2024年第4期146-157,共12页
提出一种基于银膜的自准直外腔式光纤法布里-珀罗(EFPI)干涉仪声传感器阵列,用于中低频声信号的检测以及二维平面声源定位。传感器阵列由三个相同结构的EFPI组成,结构简单、制作简便。银膜的应用和准直器的引入提高了传感器的声压灵敏度... 提出一种基于银膜的自准直外腔式光纤法布里-珀罗(EFPI)干涉仪声传感器阵列,用于中低频声信号的检测以及二维平面声源定位。传感器阵列由三个相同结构的EFPI组成,结构简单、制作简便。银膜的应用和准直器的引入提高了传感器的声压灵敏度,扩大了声源定位范围。实验结果表明:单个传感器声压灵敏度为185 mV/Pa,最小可探测声压为52.7μPa/Hz^(1/2)@500 Hz。在声源指向性实验中,声源设置在传感器正前方时,其声压灵敏度达到185 mV/Pa,声源设置在传感器侧面(90°,270°)时,其声压灵敏度衰减仅为4.5%。传感器阵列结合到达时间差技术,成功实现高精度的声源定位,系统的理论空间分辨率为0.71 cm,最大定位误差不超过2.8 cm,定位范围为200 cm×200 cm,具有成本低、实用性高等优点。 展开更多
关键词 光纤声传感器 法布里-珀罗谐振腔 自准直器 声源定位 到达时间差
下载PDF
光纤法布里-珀罗(Fabry-Perot)腔液位传感器 被引量:25
10
作者 阮驰 高应俊 +2 位作者 刘志麟 黄伟荣 郝爱花 《光子学报》 EI CAS CSCD 北大核心 2003年第10期1170-1174,共5页
提出了一种用于测量液体容器液位高度的新型光纤F P(Fabry Perot)腔传感器 ,它灵敏度高 ,实现了全光传感和传输 ,特别适用于一些有害、易燃、易爆液体容器液位的测定 详细分析了该类传感器的传感原理 ,并给出了传感头参量设计方法 实... 提出了一种用于测量液体容器液位高度的新型光纤F P(Fabry Perot)腔传感器 ,它灵敏度高 ,实现了全光传感和传输 ,特别适用于一些有害、易燃、易爆液体容器液位的测定 详细分析了该类传感器的传感原理 ,并给出了传感头参量设计方法 实验结果表明 ,光纤F P腔传感器测量液位方法简单 ,并且可达到相当高的精度 文中分析了实验中的误差 ,探讨了传感器的稳定性及改进方法 ,是光纤法布里 展开更多
关键词 法布里-珀罗(Fabry-Pemt)腔 液位 光纤传感器
下载PDF
基于敏感Fabry-Perot腔光纤角位移传感器的原理与设计 被引量:6
11
作者 吕涛 刘德森 +3 位作者 刘志麟 郎贤礼 蒋小平 朱少丽 《光子学报》 EI CAS CSCD 北大核心 2005年第7期1049-1052,共4页
提出了一种全角度并且可以连续测量微小角位移(秒级)的新型光纤角位移传感器.利用微小光学谐振腔的基本理论,主要是基于光学法布里珀罗(FabryPerot)腔的基本原理研究特定光波下光强度的变化与角位移的线性变化关系,利用光纤技术、敏感... 提出了一种全角度并且可以连续测量微小角位移(秒级)的新型光纤角位移传感器.利用微小光学谐振腔的基本理论,主要是基于光学法布里珀罗(FabryPerot)腔的基本原理研究特定光波下光强度的变化与角位移的线性变化关系,利用光纤技术、敏感技术融合微机械技术研发而成.适合于一些特定领域中对角位移的精确测量. 展开更多
关键词 光纤传感器 法布里-珀罗(fabry-perot)腔 角位移
下载PDF
光纤Fabry-Perot腔振动传感器 被引量:17
12
作者 江毅 刘莉 《光子学报》 EI CAS CSCD 北大核心 2003年第9期1059-1062,共4页
用频谱分析的方法对光纤Fabry Perot腔传感器的输出信号进行解调 在正弦振动条件下 ,用干涉信号的 3次谐波与基次波的功率比直接计算出振动幅度 ,可以简单地解调出信号
关键词 光纤传感器 fabry-perot 振动幅度 频谱 解调 大型发电机组 监测
下载PDF
基于非本征Fabry-Perot腔光纤液位传感器研究 被引量:6
13
作者 吕涛 刘德森 +2 位作者 刘志麟 何开华 程永进 《光子学报》 EI CAS CSCD 北大核心 2007年第4期690-693,共4页
介绍了适用于液位测量的强度型非本征法布里-珀罗(F-P)腔光纤液位传感器的结构设计及其性能.实验观察到F-P腔具有良好的多周期输出特性和局部的线性特性,选用局部的1/4周期输出线性段作为线性工作区间可对液位进行高准确度、连续性测量... 介绍了适用于液位测量的强度型非本征法布里-珀罗(F-P)腔光纤液位传感器的结构设计及其性能.实验观察到F-P腔具有良好的多周期输出特性和局部的线性特性,选用局部的1/4周期输出线性段作为线性工作区间可对液位进行高准确度、连续性测量.恰当选择敏感组件的尺寸可设计不同量程的传感器.实验结果表明,传感器测量3.5 m水位时,精确度为±2mm,最小分辨率为1mm. 展开更多
关键词 光纤传感器 法布里-珀罗腔 液位 弹性硅片
下载PDF
干涉条纹计数法光纤Fabry-Perot腔液位传感器 被引量:6
14
作者 赵中华 高应俊 +3 位作者 骆宇锋 周密 丁涛 张志律 《光子学报》 EI CAS CSCD 北大核心 2008年第7期1369-1372,共4页
提出一种抗光源波动和外界干扰的条纹计数法光纤Fabry-Perot腔干涉型液位传感器.为适应这种条纹计数法对应变大挠度的要求,采用波纹管作应力弹性元件;对干涉条纹走向(或液位升降判向),分别提出实用的硬件设计方案和计算机软件处理办法;... 提出一种抗光源波动和外界干扰的条纹计数法光纤Fabry-Perot腔干涉型液位传感器.为适应这种条纹计数法对应变大挠度的要求,采用波纹管作应力弹性元件;对干涉条纹走向(或液位升降判向),分别提出实用的硬件设计方案和计算机软件处理办法;给出一种腔长温度补偿设计;实际制作了双光路光纤Fabry-Perot腔液位传感器,进行了实际气压模拟试验和实际水位测量试验,取得了良好结果. 展开更多
关键词 光纤液位传感器 法布里-珀罗腔 条纹计数法 波纹管
下载PDF
基于石墨烯膜的光纤Fabry-Perot腔干涉特性分析 被引量:1
15
作者 李成 郭婷婷 +2 位作者 肖俊 樊尚春 靳伟 《北京航空航天大学学报》 EI CAS CSCD 北大核心 2015年第4期574-579,共6页
针对以新型材料石墨烯为膜片的光纤法珀压力传感器,应用圆薄膜大挠度弹性理论,利用有限元法分析了均布载荷下石墨烯膜的挠度形变;并基于Fabry-Perot干涉仪原理,建立了光纤Fabry-Perot腔压力传感的数学模型.根据石墨烯膜折射率特性,分析... 针对以新型材料石墨烯为膜片的光纤法珀压力传感器,应用圆薄膜大挠度弹性理论,利用有限元法分析了均布载荷下石墨烯膜的挠度形变;并基于Fabry-Perot干涉仪原理,建立了光纤Fabry-Perot腔压力传感的数学模型.根据石墨烯膜折射率特性,分析了层数、入射光角度等参数对石墨烯膜反射率的影响,获取了腔长损耗以及薄膜挠度形变导致腔长变化而引起的干涉光谱变化规律.仿真结果表明,增加薄膜层数可提高反射率、改善干涉性能;但随着载荷增加,其对挠度形变的影响表现为反向递减效应.8层石墨烯薄膜可获得0.715%的反射率,且当腔长为40μm时,直径25μm薄膜的理论压力灵敏度约为10 nm/k Pa.这为基于多层石墨烯的膜片式光纤压力传感器的设计提供了理论依据. 展开更多
关键词 光纤fabry-perot 石墨烯膜 大挠度 干涉特性 压力传感器
下载PDF
光纤法布里-珀罗(Fabry-Perot)干涉腔在传感器中的应用 被引量:2
16
作者 毕卫红 郑绳楦 《燕山大学学报》 CAS 2000年第2期135-140,共6页
综述了Fabry-Perot干涉仪在各种光纤传感器(如位移、应变、压力等传感器)中的应用。重点介绍这些传感器的结构、工作原理及最新研究成果。
关键词 干涉腔 光纤 传感器
下载PDF
双Fabry-Perot干涉腔型光纤声发射传感器 被引量:3
17
作者 赵江海 章小建 《光学精密工程》 EI CAS CSCD 北大核心 2015年第11期3069-3076,共8页
设计了一种新型的双Fabry-Perot腔光纤传感器用于材料损伤引起的声发射信号检测。基于低细度Fabry-Perot腔多光束干涉原理,建立了光纤Fabry-Perot传感器检测声发射信号的数学模型。分析双Fabry-Perot腔正交点稳定工作机制,设计并制作了... 设计了一种新型的双Fabry-Perot腔光纤传感器用于材料损伤引起的声发射信号检测。基于低细度Fabry-Perot腔多光束干涉原理,建立了光纤Fabry-Perot传感器检测声发射信号的数学模型。分析双Fabry-Perot腔正交点稳定工作机制,设计并制作了具有双Fabry-Perot腔结构的光纤声发射传感器来保持传感器正交点的稳定性。通过模拟AE信号检测与热应力干扰实验对设计的传感器进行了实验验证。实验一通过冲击振动与折断铅笔芯产生两类模拟声发射信号,使用商用的压电传感器和光纤传感器进行对比实验,结果表明光纤传感器能够成功检测到两类模拟声发射信号,灵敏度为12.9nm,带宽达到30kHz。实验二对传感器进行工作点稳定测试,结果表明双F-P腔的控制机制能够保证传感器工作在正交点,解决了传感器输出信号衰减的问题。 展开更多
关键词 声发射 光纤传感器 fabry-perot 正交点 材料损伤检测
下载PDF
利用LD自混合干涉的光纤Fabry-Perot传感器
18
作者 黄民双 冯音琦 《压电与声光》 CSCD 北大核心 2006年第6期634-636,共3页
提出了基于半导体激光器(LD)自混合干涉原理的光纤Fabry-Perot(F-P)传感器。采用F-P腔模型推导出了LD输出功率、频率与外部光纤F-P腔长变化的理论关系式,分析讨论了这种传感器的分辨率、测量范围、线性度、灵敏度等特性。实验结果与理... 提出了基于半导体激光器(LD)自混合干涉原理的光纤Fabry-Perot(F-P)传感器。采用F-P腔模型推导出了LD输出功率、频率与外部光纤F-P腔长变化的理论关系式,分析讨论了这种传感器的分辨率、测量范围、线性度、灵敏度等特性。实验结果与理论分析基本吻合。与现有的外腔式F-P干涉光纤传感器相比,LD自混合干涉光纤F-P传感器具有结构简单、紧凑、易准直等优点。 展开更多
关键词 LD自混合干涉 光纤fabry-perot 光纤传感器
下载PDF
光纤铅酸蓄电池安全在线监测技术研究
19
作者 赵燕杰 牛昊 +2 位作者 李惠 李文敬 孙纯 《山东建筑大学学报》 2024年第2期102-107,共6页
铅酸蓄电池的电解液变化对于电池安全运行状态至关重要,研究植入性传感技术有助于精确监控蓄电池内部电解液变化等过程,及时在线获得蓄电池的实时工作性能与状态,在蓄电池安全监测领域具有重要意义。文章提出并设计了一种基于全光纤法布... 铅酸蓄电池的电解液变化对于电池安全运行状态至关重要,研究植入性传感技术有助于精确监控蓄电池内部电解液变化等过程,及时在线获得蓄电池的实时工作性能与状态,在蓄电池安全监测领域具有重要意义。文章提出并设计了一种基于全光纤法布里-珀罗(Fabry-Perot,FP)干涉仪的液体浓度传感器,其探头是由两段单模光纤和一段U形毛细石英玻璃管构成的开放式FP腔,可以使液体轻松进入空腔,不易形成气泡。该结构具有耐强酸强碱、侵入性低、体积小、抗电磁干扰和绝缘体特性等优势,可植入铅酸蓄电池内部,实现对电解液中的硫酸溶液浓度的实时在线监测。结果表明:在硫酸为0~30%的体积分数范围内,FP腔的有效腔长和硫酸溶液的体积分数具有良好的线性度,其拟合系数达0.995,硫酸溶液的体积分数测量值与真实值之间的最大偏移量<±1.05%。 展开更多
关键词 铅酸蓄电池 光纤传感器 光纤FP腔 硫酸体积分数监测
下载PDF
Design of Fiber Magnetic Field Sensor Based on Fiber Bragg Grating Fabry-Perot Cavity Ring-Down Spectroscopy 被引量:5
20
作者 Qi LI Haiyan CHEN 《Photonic Sensors》 SCIE EI CAS CSCD 2015年第2期189-192,共4页
A novel fiber magnetic sensor based on the fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down technique with pulse laser injection is proposed and demonstrated theoretically. A general expression of the inten... A novel fiber magnetic sensor based on the fiber Bragg grating Fabry-Perot (FBG-FP) cavity ring-down technique with pulse laser injection is proposed and demonstrated theoretically. A general expression of the intensity of the output electric field is derived, and the effect of the external magnetic field on the ring-down time is discussed. The results show that the output light intensity and the ring-down time of the FBG-FP cavity are in the inverse proportion to the magnitude of the external magnetic field. Our results demonstrate the new concept of the fiber magnetic sensor with the FBG-FP cavity ring-down spectroscopy and the technical feasibility. 展开更多
关键词 fiber magnetic field sensor fiber Bragg grating fabry-perot cavity cavity ring-down spectroscopy
原文传递
上一页 1 2 10 下一页 到第
使用帮助 返回顶部