A significant number of fire-induced power disruptions are observed in several countries every year. The faults are normally phase-to-phase short circuiting or conductor-to-ground discharges at mid-span region of the ...A significant number of fire-induced power disruptions are observed in several countries every year. The faults are normally phase-to-phase short circuiting or conductor-to-ground discharges at mid-span region of the high-voltage transmission system. In any case, the wildfire plumes provide a conductive path. The electrical conductivity is due to intense heat in combustion zone of the fire which creates ion and electrons from flame inherent particulates. Increase in the ion concentration increases the electrical conductivity of the fire plume. The main purpose of this study was to measure dielectric breakdown electric field for vegetation and hydrocarbon flames. The experimental data is needed for validation of simulation schemes which are necessary for evaluation of power grid systems reliability under extreme wildfire weather conditions. In this study, hydrocarbon and vegetation fuels were ignited in a cylindrically shaped steel burner which was fitted with type-K thermocouples to measure flame temperature. The fuels consisted of dried weeping wattle (Peltophorum africanum) litter, butane gas and candle wax. Two pinned copper electrodes supported by retort stands were mounted to the burner and energized to a high voltage. This generated a strong electric field sufficient to initiate dielectric breakdown in the flames. Breakdown electric field strength (Ecrit) obtained from the experiment decreased from 10.5 to 6.9 kV/cm for the flames with temperature range of 1003 to 1410 K, respectively.展开更多
Water mist is one of the effective candidates for halon replacement used in electrical environment fire protec-tion. Water mist additives may greatly enhance fire suppres-sion effectiveness. In electrical environment,...Water mist is one of the effective candidates for halon replacement used in electrical environment fire protec-tion. Water mist additives may greatly enhance fire suppres-sion effectiveness. In electrical environment, electrical breakdown field strength (E) is one of the important factors that control the performance of electrical equipment. In this study the variation principles of electrical breakdown field strength and the electrical characteristics of MC additives were investigated by electrode discharging experiments. Ex-perimental results showed that electrical breakdown field strength was impacted obviously by the conductive metal ions and insulated fluorocarbon surfactants in MC additives. The attenuation percentages of E in different experimental cases were described, thus providing scientific guidance for the use of water mist and MC additives in electrical fire sup-pression.展开更多
文摘A significant number of fire-induced power disruptions are observed in several countries every year. The faults are normally phase-to-phase short circuiting or conductor-to-ground discharges at mid-span region of the high-voltage transmission system. In any case, the wildfire plumes provide a conductive path. The electrical conductivity is due to intense heat in combustion zone of the fire which creates ion and electrons from flame inherent particulates. Increase in the ion concentration increases the electrical conductivity of the fire plume. The main purpose of this study was to measure dielectric breakdown electric field for vegetation and hydrocarbon flames. The experimental data is needed for validation of simulation schemes which are necessary for evaluation of power grid systems reliability under extreme wildfire weather conditions. In this study, hydrocarbon and vegetation fuels were ignited in a cylindrically shaped steel burner which was fitted with type-K thermocouples to measure flame temperature. The fuels consisted of dried weeping wattle (Peltophorum africanum) litter, butane gas and candle wax. Two pinned copper electrodes supported by retort stands were mounted to the burner and energized to a high voltage. This generated a strong electric field sufficient to initiate dielectric breakdown in the flames. Breakdown electric field strength (Ecrit) obtained from the experiment decreased from 10.5 to 6.9 kV/cm for the flames with temperature range of 1003 to 1410 K, respectively.
基金This work was supported by the China National Key Basic Research Special Funds(Grant No.2001CB409600)the National Natural Science Foundation of China(Grant No.50323005)the Anhui Development Fund of Person with Ability(Grant No.2003Z019).
文摘Water mist is one of the effective candidates for halon replacement used in electrical environment fire protec-tion. Water mist additives may greatly enhance fire suppres-sion effectiveness. In electrical environment, electrical breakdown field strength (E) is one of the important factors that control the performance of electrical equipment. In this study the variation principles of electrical breakdown field strength and the electrical characteristics of MC additives were investigated by electrode discharging experiments. Ex-perimental results showed that electrical breakdown field strength was impacted obviously by the conductive metal ions and insulated fluorocarbon surfactants in MC additives. The attenuation percentages of E in different experimental cases were described, thus providing scientific guidance for the use of water mist and MC additives in electrical fire sup-pression.