Analytical and numerical computed models are developed for reverse pulse cleaning system of candle ceramic filters. A standard turbulent model is demonstrated suitably to the designing computation of reverse pulse cle...Analytical and numerical computed models are developed for reverse pulse cleaning system of candle ceramic filters. A standard turbulent model is demonstrated suitably to the designing computation of reverse pulse cleaning system from the experimental and one dimensional computational result. The computed results can be used to guide the designing of reverse pulse cleaning system, which is optimum Venturi geometry. From the computed results, the general conclusions and the designing methods are obtained.展开更多
Inferior vena cava filters have gained increasing popularity in recent decades and knowledge on rare complications becomes vital to practicing physicians. A 30-year-old African American male with diabetes mellitus, hy...Inferior vena cava filters have gained increasing popularity in recent decades and knowledge on rare complications becomes vital to practicing physicians. A 30-year-old African American male with diabetes mellitus, hypertension, end-stage renal disease, history of deep venous thrombosis and placement of venacaval filter who was seen in the cardiology clinic for cardiac risks stratification prior to renal transplant. Patient denied any cardiac symptoms. A transthoracic echocardiogram was performed and showed two linear echoes bright densities in the right atrium and right ventricle embedded which was later found to be fractured filter struts by computed tomography. We discuss the various outcomes associated with nonretrieval of retrievable inferior vena cava filters.展开更多
Seismic data with high signal-to-noise ratios(SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which i...Seismic data with high signal-to-noise ratios(SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which is costly in materials, and human and financial resources. We introduce a method for improving the SNR of seismic data. The SNR is calculated by using the frequency domain method. Furthermore, we optimize and discuss the critical parameters and calculation procedure. We applied the proposed method on real data and found that the SNR is high in the seismic marker and low in the fracture zone. Consequently, this can be used to extract detailed information about fracture zones that are inferred by structural analysis but not observed in conventional seismic data.展开更多
Catalytic filters including catalytic bag filters and catalytic filter candles, which couple the filters with denitrification catalysts to obtain the ability to simultaneously remove SOx, NOx and dust, have become the...Catalytic filters including catalytic bag filters and catalytic filter candles, which couple the filters with denitrification catalysts to obtain the ability to simultaneously remove SOx, NOx and dust, have become the promising applied technology for the integrated flue gas treatment because of their huge advantages in reducing the initial investment, floor occupancy and maintenance cost. In this review, we will summarize the recent advances in the development of catalytic filters in terms of their process principles, filter material, denitrification catalysts, structure-function relationships and industrial applications. Moreover, suggestions about the current challenges and future opportunities are also given from the viewpoints of catalysts and filter material design, catalytic filter preparation methods, and their poisoning and regeneration, etc. With the further development of theory and engineering research, the extensive industrial application of catalytic filters in the field of multiple pollutants flue gas treatment is highly anticipated in the future.展开更多
基金TheNationalNaturalScienceFoundationofChina (No .5 9776 0 2 5 )andtheHi TechResearchandDevelopmentProgramofChina (S 86 3No.2 0 0 1AA3330 40 ) )
文摘Analytical and numerical computed models are developed for reverse pulse cleaning system of candle ceramic filters. A standard turbulent model is demonstrated suitably to the designing computation of reverse pulse cleaning system from the experimental and one dimensional computational result. The computed results can be used to guide the designing of reverse pulse cleaning system, which is optimum Venturi geometry. From the computed results, the general conclusions and the designing methods are obtained.
文摘Inferior vena cava filters have gained increasing popularity in recent decades and knowledge on rare complications becomes vital to practicing physicians. A 30-year-old African American male with diabetes mellitus, hypertension, end-stage renal disease, history of deep venous thrombosis and placement of venacaval filter who was seen in the cardiology clinic for cardiac risks stratification prior to renal transplant. Patient denied any cardiac symptoms. A transthoracic echocardiogram was performed and showed two linear echoes bright densities in the right atrium and right ventricle embedded which was later found to be fractured filter struts by computed tomography. We discuss the various outcomes associated with nonretrieval of retrievable inferior vena cava filters.
基金This work was supported by the National Natural Science Foundation of China (No. 41074104) and Open Fund of Key Laboratory of Exploration Technologies for Oil and Gas Resources (Yangtze University), Ministry of Education (No. K2013-05).
文摘Seismic data with high signal-to-noise ratios(SNRs) are useful in reservoir exploration. To obtain high SNR seismic data, significant effort is required to achieve noise attenuation in seismic data processing, which is costly in materials, and human and financial resources. We introduce a method for improving the SNR of seismic data. The SNR is calculated by using the frequency domain method. Furthermore, we optimize and discuss the critical parameters and calculation procedure. We applied the proposed method on real data and found that the SNR is high in the seismic marker and low in the fracture zone. Consequently, this can be used to extract detailed information about fracture zones that are inferred by structural analysis but not observed in conventional seismic data.
基金support of the Natural Science Foundation of China(Grant 21601192 and 21878310)the National Key Research and Development Program of China(2017YFB0310403)the open subject from the State Key Laboratory of Multi-phase Complex Systems(Grant MPCS-2019-0-03)。
文摘Catalytic filters including catalytic bag filters and catalytic filter candles, which couple the filters with denitrification catalysts to obtain the ability to simultaneously remove SOx, NOx and dust, have become the promising applied technology for the integrated flue gas treatment because of their huge advantages in reducing the initial investment, floor occupancy and maintenance cost. In this review, we will summarize the recent advances in the development of catalytic filters in terms of their process principles, filter material, denitrification catalysts, structure-function relationships and industrial applications. Moreover, suggestions about the current challenges and future opportunities are also given from the viewpoints of catalysts and filter material design, catalytic filter preparation methods, and their poisoning and regeneration, etc. With the further development of theory and engineering research, the extensive industrial application of catalytic filters in the field of multiple pollutants flue gas treatment is highly anticipated in the future.