An experimental study was conducted on shock wave turbulent boundary layer interactions caused by a blunt swept fin-plate configuration at Mach numbers of 5.0, 7.8, 9.9 for a Reynolds number range of (1.0.similar to 4...An experimental study was conducted on shock wave turbulent boundary layer interactions caused by a blunt swept fin-plate configuration at Mach numbers of 5.0, 7.8, 9.9 for a Reynolds number range of (1.0.similar to 4.7) x 10(7)/m. Detailed heat transfer and pressure distributions were measured at fin deflection angles of up to 30 degrees for a sweepback angle of 67.6 degrees. Surface oil flow patterns and liquid crystal thermograms as well as schlieren pictures of fin shock shape were taken. The study shows that the flow was separated at deflection of 10 degrees and secondary separation were detected at deflection of theta greater than or equal to 20 degrees. The heat transfer and pressure distributions on flat plate showed an extensive plateau region followed by a distinct dip and local peak close to the fin foot. Measurements of the plateau pressure and heat transfer were in good agreement with existing prediction methods, but pressure and heating peak measurements at M greater than or equal to 6 were significantly lower than predicted by the simple prediction techniques at lower Mach numbers.展开更多
Thermal conductivity of frost is not only related to density, but also affected by its microstructure and environmental conditions, and it will continuously change with the formation and growth of frost. Images of fro...Thermal conductivity of frost is not only related to density, but also affected by its microstructure and environmental conditions, and it will continuously change with the formation and growth of frost. Images of frost formation and growth on the cryogenic surface in various shapes at different stages were obtained by experimental measurements, and a numerical simulation of frost formation and growth was carried out based on Diffusion Limited Aggregation (DLA) model of fractal theory in this paper. Based on the frost structure obtained by experiment, the fractal dimension of pore area distribution and porosity of frost layer on the cryogenic finned-tube?vaporizer were calculated by using fractal method, and combined with heat conduction model of frost layer obtained by thermal resistance method, the thermal conductivity of frost on the cryogenic surface was calculated. The result shows that the thermal conductivity calculated by the fractal model coincides with the range of the experimental data. Additionally, comparison with other heat conduction models indicated that it is feasible to introduce the fractal dimension of pore area distribution into heat conduction model to deduce the thermal conductivity of frost.展开更多
In this study it is demonstrated that oxygen-plasma-generated CuOx can enhance the holes injection from ITO anode into polymer layer in single-layer polymer EL devices. The possible reason for this enhancement is beca...In this study it is demonstrated that oxygen-plasma-generated CuOx can enhance the holes injection from ITO anode into polymer layer in single-layer polymer EL devices. The possible reason for this enhancement is because the ITO anode modified with CuOx possesses much higher work function than pure ITO anode, which reduces the barrier for hole-injection and further lowers the operational voltage of the polymer EL devices. The work function shift is probable due to the oxygen-plasma-generated CuOx can store more releasable oxygen, and the releasable oxygen in turn changes the oxygen concentration just near ITO surface, which will shift the work function of ITO anode.展开更多
基金The project supported by China Academy of Launch Vehicle Technology
文摘An experimental study was conducted on shock wave turbulent boundary layer interactions caused by a blunt swept fin-plate configuration at Mach numbers of 5.0, 7.8, 9.9 for a Reynolds number range of (1.0.similar to 4.7) x 10(7)/m. Detailed heat transfer and pressure distributions were measured at fin deflection angles of up to 30 degrees for a sweepback angle of 67.6 degrees. Surface oil flow patterns and liquid crystal thermograms as well as schlieren pictures of fin shock shape were taken. The study shows that the flow was separated at deflection of 10 degrees and secondary separation were detected at deflection of theta greater than or equal to 20 degrees. The heat transfer and pressure distributions on flat plate showed an extensive plateau region followed by a distinct dip and local peak close to the fin foot. Measurements of the plateau pressure and heat transfer were in good agreement with existing prediction methods, but pressure and heating peak measurements at M greater than or equal to 6 were significantly lower than predicted by the simple prediction techniques at lower Mach numbers.
文摘Thermal conductivity of frost is not only related to density, but also affected by its microstructure and environmental conditions, and it will continuously change with the formation and growth of frost. Images of frost formation and growth on the cryogenic surface in various shapes at different stages were obtained by experimental measurements, and a numerical simulation of frost formation and growth was carried out based on Diffusion Limited Aggregation (DLA) model of fractal theory in this paper. Based on the frost structure obtained by experiment, the fractal dimension of pore area distribution and porosity of frost layer on the cryogenic finned-tube?vaporizer were calculated by using fractal method, and combined with heat conduction model of frost layer obtained by thermal resistance method, the thermal conductivity of frost on the cryogenic surface was calculated. The result shows that the thermal conductivity calculated by the fractal model coincides with the range of the experimental data. Additionally, comparison with other heat conduction models indicated that it is feasible to introduce the fractal dimension of pore area distribution into heat conduction model to deduce the thermal conductivity of frost.
文摘In this study it is demonstrated that oxygen-plasma-generated CuOx can enhance the holes injection from ITO anode into polymer layer in single-layer polymer EL devices. The possible reason for this enhancement is because the ITO anode modified with CuOx possesses much higher work function than pure ITO anode, which reduces the barrier for hole-injection and further lowers the operational voltage of the polymer EL devices. The work function shift is probable due to the oxygen-plasma-generated CuOx can store more releasable oxygen, and the releasable oxygen in turn changes the oxygen concentration just near ITO surface, which will shift the work function of ITO anode.