期刊文献+
共找到1,479篇文章
< 1 2 74 >
每页显示 20 50 100
Fin formation model during pre-roll ploughing of copper 3D outside fin tube 被引量:15
1
作者 汤勇 夏伟 +2 位作者 曾志新 刘树道 叶帮彦 《中国有色金属学会会刊:英文版》 CSCD 2001年第5期712-716,共5页
The mechanism of pre roll ploughing for 3D fins on the outside surface of copper tube was studied systematically, and especially the process and conditions of 3D fin formation were analyzed. The right mathematical mod... The mechanism of pre roll ploughing for 3D fins on the outside surface of copper tube was studied systematically, and especially the process and conditions of 3D fin formation were analyzed. The right mathematical model was also established. Based on the volume of fin ploughed out is equal to the volume of the metal extruded up by the extruding face of the tool, the relations between fin height, pre roll ploughing feed and pre roll ploughing depth have been achieved. With the increase of pre roll ploughing depth which must be equal to groove depth, the fin height gradually becomes larger. There are different critical feeds with the various depths of pre roll ploughing. The pre roll ploughing feed is the critical one, the height of fin is largest. And when the feed is above the critical one, the fin height will reduce with the increase of feed. The theoretical analysis basically accords with experimental results. 展开更多
关键词 pre roll ploughing copper 3D outside fin tube heat transfer
下载PDF
Surface treatment of 3D outside serrated integral-fin tube manufactured by rolling and extrusion
2
作者 白鹏飞 刘小康 +1 位作者 燕辉 唐彪 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2010年第5期844-848,共5页
The outside serrated integral-fin tubes fabricated by rolling-plowing-extrusion processing were surface-treated through different processes of annealing in hydrogen atmosphere,electrochemical corrosion or sandblasting... The outside serrated integral-fin tubes fabricated by rolling-plowing-extrusion processing were surface-treated through different processes of annealing in hydrogen atmosphere,electrochemical corrosion or sandblasting.The purpose was to eliminate residual stress,clear secondary micro-fins and enhance heat transfer performance.By comparing the surface characteristics,it is found that the finned tubes treated by electrochemical corrosion have the most glabrous surfaces where the fins are almost perfectly reserved.Clear layer cracks can be observed on the top of the fins.These structures are effective in enhancing heat transfer performance when being applied to flow heat exchange.Therefore,the finned tubes treated by electrochemical corrosion are proper for the tubular exchanger with water coolant.The finned tubes treated by sandblasting have rougher surfaces with layer cracks and micro gaps removed.As these structures are useful to clearing adhesive feculence,the tubes are more suitable for the tubular heat exchanger with oil coolant. 展开更多
关键词 表面处理 挤压加工 翅片管 锯齿 电化学腐蚀 电化学治疗 结构胶粘剂 管式换热器
下载PDF
Convective Boiling of Near-Azeotropic Refrigerant R410A in the Horizontal Micro-fin Tube
3
作者 段雪涛 马虎根 +1 位作者 邬志敏 王芳 《Journal of Shanghai Jiaotong university(Science)》 EI 2007年第1期73-75,80,共4页
Using near-azeotropic refrigerant R410A as the working fluid, the experimental studies on the horizontal micro-fin tubes were conducted. Several factors affecting heat transfer coefficients were analyzed, and the char... Using near-azeotropic refrigerant R410A as the working fluid, the experimental studies on the horizontal micro-fin tubes were conducted. Several factors affecting heat transfer coefficients were analyzed, and the characteristics of flow boiling of the refrigerant in the horizontal micro-fin tubes were discussed. The local heat transfer coefficients increase with mass flux, heat flux and quality. And the heat transfer enhancement factor of those testing tubes is about 1.6 to 2.2. 展开更多
关键词 水平微鳍显象管 蒸发转移 制冷剂 热传递
下载PDF
Heat transfer characteristics in micro-fin tube equipped with double twisted tapes: Effect of twisted tape and micro-fin tube arrangements 被引量:5
4
作者 EIAMSA-ARD S. WONGCHAREE K. 《Journal of Hydrodynamics》 SCIE EI CSCD 2013年第2期205-214,共10页
An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of ... An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of the compound devices in the following configurations: (1) twisted tapes acted in the same direction (for co-swirl) while MF and twisted tapes acted in the same (parallel) direction (MF-CoDTs:P), (2) twisted tapes acted in the same direction (for co-swirl) while micro-fin tube and twisted tapes acted in opposite directions (MF-CoDTs:O) and (3) twisted tapes acted in opposite directions for counter swirl (MF-CDTs). The MF alone and the MF equipped with a single twisted tape in parallel/opposite arrangement were also considered for comparison. The experiments were conducted for the flows with the Reynolds numbers between 5 650 and 17 000, under uniform heat flux condition. The experimental results indicate that MF-CDTs induce stronger swirl/turbulence flow, resulting in higher heat transfer rate, friction factor and thermal performance factor than other combined devices. The thermal performance factors associated with the use of MF-CDTs were found to be higher than those associated with the uses of MF-CoDTs:P, MF-CoDTs:O and MF alone up to 9.3%, 6.5% and 56.4%, respectively. The empirical correlations developed using the present experimental data for the Nusselt number, friction factor and thermal performance factor are also reported. 展开更多
关键词 micro-fin tube (MF) double twisted-tapes (DTs) co-swirl counter-swirl heat transfer enhancement
原文传递
Experimental Research on Resistance Characteristics of H-type Elliptical Finned Tube Bundles 被引量:7
5
作者 LI Fei SHI Yuetao SUN Fengzhong 《中国电机工程学报》 EI CSCD 北大核心 2013年第32期I0006-I0006,8,共1页
阻力特性是换热器的基本特性之一,流体横掠换热管产生的绕流扰动是换热器阻力恶化的主要因素。为分析前排绕流对后排阻力的影响规律,分别对管排数2-10不等的换热管进行阻力特性试验研究,同时为定量分析管排数对阻力特性的影响规律,... 阻力特性是换热器的基本特性之一,流体横掠换热管产生的绕流扰动是换热器阻力恶化的主要因素。为分析前排绕流对后排阻力的影响规律,分别对管排数2-10不等的换热管进行阻力特性试验研究,同时为定量分析管排数对阻力特性的影响规律,定义了管排阻力修正系数,并根据实验数据给出了其在不同管排数下的取值,具有重要的工程意义;同时基于冷态阻力特性试验台进行实验研究,得到κ=1及κ=1.6的经典椭圆管的阻力特性公式Eu,并研究不同管型及布置方式对其的影响规律。 展开更多
关键词 翅片管束 阻力特性 H型 试验 椭圆 传热性能 灰分沉积 矩形翅片
下载PDF
Formation mechanism of external finned tubes by extrusion-plough method 被引量:4
6
作者 汤勇 陆龙生 +2 位作者 潘敏强 刘小康 刘晓晴 《中国有色金属学会会刊:英文版》 CSCD 2006年第A02期283-288,共6页
关键词 挤压-犁切法 外翅管 成型 机理
下载PDF
Compound forming technology of outside 3D integral fin of copper tubes 被引量:3
7
作者 向建化 汤勇 +3 位作者 叶邦彦 周伟 燕辉 胡志华 《中国有色金属学会会刊:英文版》 EI CSCD 2009年第2期335-340,共6页
Using rolling-ploughing-extrusion compound processing methods,a 3D integral-fin structure on outside surface of red copper tube with diameter of 16.0 mm and wall thickness of 1.5 mm was obtained. When both rolling dep... Using rolling-ploughing-extrusion compound processing methods,a 3D integral-fin structure on outside surface of red copper tube with diameter of 16.0 mm and wall thickness of 1.5 mm was obtained. When both rolling depth and ploughing-extrusion(P-E) depth were 0.2 mm,rotating speed was 50 r/min,feed speed was 0.16 mm/r,3D fin structures with height of 0.25 mm were gotten. Two different fin structures were obtained in grooves formed with rolling-ploughing-extrusion compound forming technology and observed by scanning electron microscope(SEM). One is the compound structure with V-shaped groove and U-shaped groove,and the other is the single structure with V-shaped grooves. Two kinds of groove structures obtained by rolling processing and ploughing extrusion processing are restricted together by groove interval and rolling depth,and pitch and P-E depth,respectively. Based on the analysis of interaction of rolling and P-E processing,it is found from the result that the outside 3D integral-fin can be achieved by rolling-ploughing-extrusion compound processing when single V-shaped groove structures are formed by both rolling and P-E processing. 展开更多
关键词 整体翅片 挤出复合 成形技术 三维 铜管 扫描电子显微镜 复合结构 挤压工艺
下载PDF
Analysis of Thermal Conductivity of Frost on Cryogenic Finned-tube Vaporizer Using Fractal Method 被引量:1
8
作者 Shuping Chen Shuting Yao Fushou Xie 《Energy and Power Engineering》 2013年第4期109-115,共7页
Thermal conductivity of frost is not only related to density, but also affected by its microstructure and environmental conditions, and it will continuously change with the formation and growth of frost. Images of fro... Thermal conductivity of frost is not only related to density, but also affected by its microstructure and environmental conditions, and it will continuously change with the formation and growth of frost. Images of frost formation and growth on the cryogenic surface in various shapes at different stages were obtained by experimental measurements, and a numerical simulation of frost formation and growth was carried out based on Diffusion Limited Aggregation (DLA) model of fractal theory in this paper. Based on the frost structure obtained by experiment, the fractal dimension of pore area distribution and porosity of frost layer on the cryogenic finned-tube?vaporizer were calculated by using fractal method, and combined with heat conduction model of frost layer obtained by thermal resistance method, the thermal conductivity of frost on the cryogenic surface was calculated. The result shows that the thermal conductivity calculated by the fractal model coincides with the range of the experimental data. Additionally, comparison with other heat conduction models indicated that it is feasible to introduce the fractal dimension of pore area distribution into heat conduction model to deduce the thermal conductivity of frost. 展开更多
关键词 CRYOGENIC finned-tube VAPORIZER Thermal Conductivity FROST Layer FRACTAL
下载PDF
A Numerical Study on Fully Developed Fluid Flow and Heat Transfer in a Spiral Finned Tube
9
作者 张建文 张政 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1999年第1期56-66,共11页
In this paper, the standard k-εtwo-equation model is adopted to numerically simulate fully developed fluid flow and heat transfer in a spiral finned tube within a cracking furnace for ethylene manufacturing. By varia... In this paper, the standard k-εtwo-equation model is adopted to numerically simulate fully developed fluid flow and heat transfer in a spiral finned tube within a cracking furnace for ethylene manufacturing. By variable transformation, the orlglnal 3-D problem is converted into a 2-D problem in spiral coordinates. The algorithm of SIMPLEC is used to study the fully developed fluld flow and heat transfer in the spiral finned tube at constant periphery temperature and constant axial heat flux, The computed results agree pretty well with the experimental data obtained from the industry, Further studies on the fluid flows and temperature profiles at different Reynolds numbers within straight and spiral finned tubes are conducted and the mechanisms involved are explored. It is found that with the spiral finned tube, pressure drop increases to a great extent whereas heat transfer tends to be decreased. 展开更多
关键词 数字模拟 螺旋管 流体流动 传热 流体力学 化工过程
下载PDF
A Prediction Model for Condensation on Single Horizontal Rectangular Fin Tube
10
作者 LiuXijuan MaTongze 《Journal of Thermal Science》 SCIE EI CAS CSCD 1997年第1期27-34,共8页
A model was established to predict condensation heat transfer coefficient on horizontal rectangular-finned tube. Drop-Off zone at the tube bottom was considered and determined, the known Honda(and owen) expression of ... A model was established to predict condensation heat transfer coefficient on horizontal rectangular-finned tube. Drop-Off zone at the tube bottom was considered and determined, the known Honda(and owen) expression of retention angle was also modified as a result of considering drop-off zone.Heat flux on fin tips in the unflooded region, fin fianks, fin spacings and fin tips in the flooded regionwere analyzed respectively. Condensation on fin tips is emphasized by considering the variation of filmthickness along circumference as well as horizootally. Fin efficiency was considered in calculation. Theprediction results were compared with several researchers’ experimental data for three kinds of workingfluids on seven different tube geometries and for various temperature differences. These data underabout 60 test conditions were predicted with discrepancy of ±10%. Prediction by the present modelfor steam and R-113 condensation were compared with previous models. 展开更多
关键词 冷凝器 单水平矩形散热管 设计模型
原文传递
Experimental investigation of enhanced heat transfer for fined circular tube heat exchanger with rectangular fins
11
作者 李永星 杨冬 陈听宽 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2006年第4期385-390,共6页
Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4×4 (columns×rows) finned-tube heat exchanger with rec... Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4×4 (columns×rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50.2 m/s, the heat transfer rate ranged from 21.8 to 47.1 kW, and the air temperatures increase ranged from 10.9 to 19.8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlauions. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are proposed based on the experimental results. 展开更多
关键词 热交换器 矩形翅片管 强化传热 摩擦因数 矩形肋
下载PDF
强制对流下翅片管蒸发器表面结霜实验
12
作者 陈清华 陆育 +2 位作者 关维娟 季家东 王建刚 《河南科技大学学报(自然科学版)》 CAS 北大核心 2024年第1期19-26,34,M0003,共10页
翅片管蒸发器表面结霜是阻碍制冷系统高效运行的主要不利因素之一。利用恒温恒湿箱搭建强制对流下蒸发器翅片管表面结霜可视化实验平台,在环境温度0~8℃、相对湿度55%~75%及迎面风速0.8~2.4 m/s时,实时记录霜层动态生长过程,研究了环境... 翅片管蒸发器表面结霜是阻碍制冷系统高效运行的主要不利因素之一。利用恒温恒湿箱搭建强制对流下蒸发器翅片管表面结霜可视化实验平台,在环境温度0~8℃、相对湿度55%~75%及迎面风速0.8~2.4 m/s时,实时记录霜层动态生长过程,研究了环境温度、相对湿度和迎面风速对霜层生长特性及蒸发器换热性能的影响规律。结果表明:环境温度和迎面风速是影响蒸发器结霜的主要因素,结霜50 min,环境温度为0℃的霜层厚度比环境温度为8℃的提高了12.78%,迎面风速为2.4 m/s的霜层厚度比迎面风速为0.8 m/s的提高了14.66%,结霜量与换热量提高趋势相同。在结霜初期,相对湿度越大,换热量越大;结霜后期,相对湿度越小,换热量越大,并得到了换热量关于环境参数与时间的相关关系。 展开更多
关键词 翅片管蒸发器 可视化 结霜 霜层生长 强制对流
下载PDF
基于响应面法的矿用翅片管空冷器参数优化
13
作者 王义江 孙莉 +2 位作者 刘梦涵 杨金宏 王国元 《化工学报》 EI CSCD 北大核心 2024年第1期279-291,共13页
矿用空冷器是矿井降温系统常用的末端设备,优化矿用空冷器换热性能对提升矿井降温系统能效具有重要意义。采用Fluent建立了平直翅片管矿用空冷器模型,研究了翅片间距、翅片厚度、横向管间距和纵向管间距对传热因子、阻力因子和综合性能... 矿用空冷器是矿井降温系统常用的末端设备,优化矿用空冷器换热性能对提升矿井降温系统能效具有重要意义。采用Fluent建立了平直翅片管矿用空冷器模型,研究了翅片间距、翅片厚度、横向管间距和纵向管间距对传热因子、阻力因子和综合性能评价指标的影响规律;采用Box-Behnken响应面法,分析了双参数协同作用下传热因子、阻力因子和综合性能评价指标变化规律。结果表明:随着翅片间距、横向管间距的减小,以及翅片厚度增加,传热因子、阻力因子和综合性能评价指标逐渐增加;综合性能评价指标则随纵向管间距的增加而先增加后降低;横向管间距、翅片厚度是影响空冷器传热及流动性能最显著的两个参数,而翅片间距、纵向管间距的影响最小;得到了平直翅片管矿用空冷器的最优参数,传热因子提升16.3%、阻力因子增加26.3%、综合性能评价指标提升8.3%。研究结果可为矿用翅片空冷器设计参数优化提供指导。 展开更多
关键词 平直翅片管空冷器 传热 流动 数值模拟 Box-Behnken响应面
下载PDF
振动作用下平直翅片管结霜初期微液滴运动过程数值模拟
14
作者 关维娟 陈清华 +3 位作者 张斌 季家东 王建刚 刘萍 《振动与冲击》 EI CSCD 北大核心 2024年第8期155-161,共7页
平直翅片管换热器在低温高湿环境中工作极易发生结霜现象,造成能耗增加、故障率升高,而对结霜初期的微液滴施加振动作用可以加速微液滴的滑落过程从而达到抑制结霜的效果。对结霜前期微液滴的生长过程进行数值模拟分析,并通过文献值验... 平直翅片管换热器在低温高湿环境中工作极易发生结霜现象,造成能耗增加、故障率升高,而对结霜初期的微液滴施加振动作用可以加速微液滴的滑落过程从而达到抑制结霜的效果。对结霜前期微液滴的生长过程进行数值模拟分析,并通过文献值验证了数值模拟的可靠性,然后利用不同时刻的微液滴数据,通过数值模拟的方式,研究不同振动频率作用下微液滴的运动特性,最后搭建试验平台进行验证。研究结果发现,不同体积的微液滴对应的最优振动频率有所不同,当微液滴体积较小时,较高的振动频率使微液滴在基管壁面来回振荡,不易滑落,当微液滴体积较大时,较高的振动频率有利于微液滴克服壁面摩擦力,有利于液滴滑落。 展开更多
关键词 制冷系统 平直翅片管 微液滴生长 振动抑霜
下载PDF
矩形翅片管糖醇相变储热器传热性能分析
15
作者 程昊天 贺明飞 +3 位作者 原郭丰 王艳 高蓬辉 王志峰 《太阳能学报》 EI CAS CSCD 北大核心 2024年第2期244-250,共7页
对糖醇基矩形翅片管相变储热器传热性能进行数值模拟与实验研究,利用数值模型研究传热流体入口温度、流量以及储热器翅片间距、管间距等参数对充放热性能的影响。研究表明:从运行参数看,由于相变材料导热系数的影响,翅片强化区外流体入... 对糖醇基矩形翅片管相变储热器传热性能进行数值模拟与实验研究,利用数值模型研究传热流体入口温度、流量以及储热器翅片间距、管间距等参数对充放热性能的影响。研究表明:从运行参数看,由于相变材料导热系数的影响,翅片强化区外流体入口温度与材料相变温度的温差对充放热速率呈正相关;在管内湍流条件下,管内流速在高于0.53 m/s时,不能显著提升储热器的充放热速率;从结构参数看,增加翅片可显著提升翅片区内充放热速率,翅片间距小于10 mm和管间距小于52.5 mm对充放热速率影响不明显。 展开更多
关键词 相变储热 共晶糖醇 数值模拟 太阳能建筑 翅片管储热器
下载PDF
房间空调器小管径室外换热器流路优化
16
作者 马迪 谭裕锋 +3 位作者 吕根贵 陈旗 吴红霞 晏刚 《西安交通大学学报》 EI CAS CSCD 北大核心 2024年第5期179-189,共11页
随着空调器的快速发展和国际铜价的持续升高,制冷空调行业采用的换热器在向着小体积、低成本发展的过程中往往面临着性能衰减的技术瓶颈。为突破此瓶颈,以一款冷暖型房间空调器翅片管式室外换热器为研究对象,将其换热管外径由7 mm减小至... 随着空调器的快速发展和国际铜价的持续升高,制冷空调行业采用的换热器在向着小体积、低成本发展的过程中往往面临着性能衰减的技术瓶颈。为突破此瓶颈,以一款冷暖型房间空调器翅片管式室外换热器为研究对象,将其换热管外径由7 mm减小至5 mm并在此基础上优化其流路,最终实现Φ5 mm换热器性能达到初始样机水平并有效降低换热器成本。首先,分别在5种标准工况下测试初始样机性能;然后,利用CoilDesigner软件来分析小管径化对换热器性能的影响,仿真结果表明,在不改变流路布置的情况下,Φ5 mm换热器的换热能力略有提升,但制冷剂侧压降增大4~7倍;进一步地,有针对性地设计了5种流路布置方案来探究分路数、分路汇合位置等因素对换热器传热及压降特性的影响规律,总结了小管径翅片管式换热器流路优化的思路,并设计了3种Φ5 mm管径室外换热器流路优化方案。仿真评估3种方案的可行性后制作样机进行性能测试,实验结果表明:方案(3)性能与原换热器相当,同时其材料成本可降低34.6%。 展开更多
关键词 房间空调器 翅片管式换热器 小管径 流路优化
下载PDF
Numerical analysis of heat transfer enhancement on steam condensation in the presence of air outside the tube 被引量:2
17
作者 Wen-Tao Li Xian-Ke Meng +1 位作者 Hao-Zhi Bian Ming Ding 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第8期55-68,共14页
In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat trans... In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%. 展开更多
关键词 Air–steam condensation Numerical simulation Heat transfer enhancement fin tube
下载PDF
多通道平行流扁管-紧凑式翅片相变蓄热器蓄/放热性能
18
作者 杜慧婷 刁彦华 +2 位作者 赵耀华 王泽宇 王国珍 《新能源进展》 CSCD 北大核心 2024年第2期141-150,共10页
工业余热浪费严重、利用率较低且实际应用过程中受到时间和空间的限制,需要高效蓄热技术和装置来解决此类问题。提出一种将多通道平行流扁管与紧凑式翅片相结合的新型相变蓄热器,以水为载热流体,月桂酸为相变材料。实验研究了载热流体... 工业余热浪费严重、利用率较低且实际应用过程中受到时间和空间的限制,需要高效蓄热技术和装置来解决此类问题。提出一种将多通道平行流扁管与紧凑式翅片相结合的新型相变蓄热器,以水为载热流体,月桂酸为相变材料。实验研究了载热流体注入方式、流量、入口温度对蓄热器蓄/放热性能的影响,并分析小温差下蓄热器的传热特性。结果显示,该蓄热器相变材料填充率为82.5%,紧凑式翅片的采用极大强化了相变材料侧换热过程,蓄/放热性能优良。当载热流体入口温度分别为45℃和41℃时,相变材料约在270 min和75 min完成相变,最小蓄/放热温差可达2℃,最小温差时的平均蓄热比功率为25.18 W/kg,平均取热比功率为20.23 W/kg。 展开更多
关键词 相变蓄热 多通道平行流扁管 紧凑式翅片 小温差
下载PDF
燃气-蒸汽联合循环机组余热锅炉尾部受热面锈蚀对烟道阻力的影响
19
作者 张卫 俞哲锋 +5 位作者 施子福 陶振涛 李宏梅 黄岳 闫凤平 周永刚 《发电设备》 2024年第3期138-143,156,共7页
在某燃气 蒸汽联合循环机组长期停机备用期间,针对其余热锅炉尾部受热面开齿螺旋鳍片管锈蚀导致烟气流动阻力升高,影响燃气轮机带负荷的问题,通过现场数据监测、数值模拟及小型试验台试验,研究鳍片管表面锈蚀状态对流动阻力特性的影响... 在某燃气 蒸汽联合循环机组长期停机备用期间,针对其余热锅炉尾部受热面开齿螺旋鳍片管锈蚀导致烟气流动阻力升高,影响燃气轮机带负荷的问题,通过现场数据监测、数值模拟及小型试验台试验,研究鳍片管表面锈蚀状态对流动阻力特性的影响。结果表明:余热锅炉尾部模块5、模块6的阻力上升明显;鳍片管背风侧的锈蚀堆积不会导致流动阻力的上升,两侧锈蚀厚度增加是流动阻力上升的主要原因;鳍片管除锈后鳍片减薄,流通截面积增大,阻力特性优于新鳍片管。 展开更多
关键词 燃气蒸汽联合循环机组 余热锅炉 鳍片管 锈蚀 流动阻力
下载PDF
某高压空冷器翅片管的泄漏原因
20
作者 文耀华 梁斌 +2 位作者 张伯君 崔强 方学锋 《腐蚀与防护》 CAS CSCD 北大核心 2024年第4期111-114,共4页
某化工企业加氢裂化装置的高压空冷器中部翅片管发生介质泄漏,通过宏微观形貌观察、微观形貌观察、能谱分析和化学成分分析等对泄漏原因进行了分析。结果表明:翅片管内壁受含有硫氢化铵的碱式酸性水腐蚀,形成了含铁的氧化物和硫化物垢物... 某化工企业加氢裂化装置的高压空冷器中部翅片管发生介质泄漏,通过宏微观形貌观察、微观形貌观察、能谱分析和化学成分分析等对泄漏原因进行了分析。结果表明:翅片管内壁受含有硫氢化铵的碱式酸性水腐蚀,形成了含铁的氧化物和硫化物垢物;结垢物堆积引起局部流场和流速发生变化,且管内介质呈气液两相状态,加剧了结垢物分布不均,引发严重的垢下腐蚀,管壁局部腐蚀减薄并最终导致穿孔。建议定期检查空冷器注水量、水质以及是否有偏流现象,控制介质流速,化验分析硫氢化铵质量分数或计算Kp系数,预防事故再次发生。 展开更多
关键词 翅片管 泄漏 垢下腐蚀 减薄 穿孔
下载PDF
上一页 1 2 74 下一页 到第
使用帮助 返回顶部