Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient a...Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient and pressure drop of a diamond-shaped fin-array with water flow in this study, which had been reported to have a self-induced flip-flop flow phenomenon. Although the flip-flop flow phenomenon occurred in calculations, it was not observed in experiments. The heat transfer and pressure drop of the diamond-shaped fin-array could be estimated with equations for turbulent flow in tubes.展开更多
This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissi...This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissipation rate is compared to that of an equivalent solid one. The parameters considered are geometrical dimensions and thermal properties of the fin and the perforations. The gain in the heat transfer enhancement and the fin weight reduction due to the perforations are considered. The study shows that the heat dissipation from the perforated fin for a certain range of triangular perforation dimensions and spaces between perforations result in improvement in the heat transfer over the equivalent solid fin. The heat transfer enhancement of the perforated fin increases as the fin thermal conductivity and its thickness are increased.展开更多
Fins are used for enhancement of heat transfer. Triangular fins are arranged in form of nozzle and heat transfer coefficient is calculated. Angle of taper of nozzle is changed i.e. angles of triangles are varied and t...Fins are used for enhancement of heat transfer. Triangular fins are arranged in form of nozzle and heat transfer coefficient is calculated. Angle of taper of nozzle is changed i.e. angles of triangles are varied and then heat transfer coefficient is calculated. Total finned area of all fins is almost the same. Number of fins and orientation of fins are different. In this study to calculate heat transfer coefficient of unfinned area open channel is considered where density and pressure are constant. This study shows that heat transfer is enhanced by 213%, 268% and 339% using 30°, 45° and 60° fins. Computational results show that heat transfer is enhanced by 108%, 130%, 146% using 30°, 45° and 60° fins.展开更多
Experimental investigation is conducted to investigate the flow and heat transfer performances of jet impingement cooling inside a semi-confined smooth channel.Effects of jet Reynolds number(varied from 10 000to 45000...Experimental investigation is conducted to investigate the flow and heat transfer performances of jet impingement cooling inside a semi-confined smooth channel.Effects of jet Reynolds number(varied from 10 000to 45000),orifice-to-target spacing(zn=1d—4d)and jet-to-jet pitches(xn=3d—5d,yn=3d—5d)on the convective heat transfer coefficient and discharge coefficient are revealed.For a single-row jets normal impingement,the impingement heat transfer is enhanced with the increase of impingement Reynolds number or the decrease of spanwise jet-to-jet pitch.The highest local heat transfer is achieved when zn/dis 2.For the double-row jets normal impingement,the laterally-averaged Nusselt number distributions in the vicinity of the first row jets impinging stagnation do not fit well with the single-row case.The highest local heat transfer is obtained when zn/dis 1.A smaller jetto-jet pitch generally results in a lower discharge coefficient.The discharge coefficient in the double-row case is decreased relative to the single-row case at the same impingement Reynolds number.展开更多
Considering the limitation in current manufacturing technology of commercial pin fin heat sinks,a new fabric heat sink has been designed. However,it is lack of an understanding of the heat transferring performance of ...Considering the limitation in current manufacturing technology of commercial pin fin heat sinks,a new fabric heat sink has been designed. However,it is lack of an understanding of the heat transferring performance of this new kind of heat sink. In this study,the finite element method (FEM) was used to predict the heat transferring performance of fabric heat sink under the condition of natural convection and forced convection, and its heat transferring performance was compared with that of pin fin heat sink. The results showed that in the condition of natural convection the heat transferring performance of pin fin heat sink was better than that of fabric heat sink, and vice versa under the forced convection condition.展开更多
Development and use of nuclear energy is currently growing very rapidly, in order to achieve increasingly advanced technology, both in terms of design, economic factors and safety factors. Thermal-hydraulics aspects o...Development and use of nuclear energy is currently growing very rapidly, in order to achieve increasingly advanced technology, both in terms of design, economic factors and safety factors. Thermal-hydraulics aspects of nuclear reactors should be done with calculation and near-perfect condition. Including today began development of a nuclear reactor with low power below 300 MW, or commonly called the Small Modular Reactor (SMR). One is CAREM-25 developed by Argentina with a power of 25 MW, where in CAREM already using natural circulation system and the use of nanofluid as coolant fluid. In this research, analytic modeling of thermal-hydraulics nuclear reactor SMR CAREM-25, when the nanofluid Al<sub>2</sub>O<sub>3</sub>-Water used as cooling fluid in the cooling system of a nuclear reactor. Further to this analytic modeling will be done on CFD. Analytic modeling with CFD to determine the flow phenomena and distribution as well as the effect of nano-particles of Al<sub>2</sub>O<sub>3</sub>-Water based on the volume fraction (1% and 3%) of the coefficient of heat transfer by natural convection.展开更多
Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfe...Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.展开更多
The special formulation that allows an accurate and efficient solution to the heat transfer problems within fin assemblies with very large aspect ratios has been developed in this paper Numerically,it consists of the ...The special formulation that allows an accurate and efficient solution to the heat transfer problems within fin assemblies with very large aspect ratios has been developed in this paper Numerically,it consists of the boundary element method in the wall region and the analytical solution in the fin region This modified BEM makes tractable a large class of heat transfer problems in the long and thin domains which are frequently encountered in practice.展开更多
Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4×4 (columns×rows) finned-tube heat exchanger with rec...Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4×4 (columns×rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50.2 m/s, the heat transfer rate ranged from 21.8 to 47.1 kW, and the air temperatures increase ranged from 10.9 to 19.8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlauions. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are proposed based on the experimental results.展开更多
A simple and highly accurate semi-analytical method, called the differential transformation method(DTM), was used for solving the nonlinear temperature distribution equation in solid and porous longitudinal fin with t...A simple and highly accurate semi-analytical method, called the differential transformation method(DTM), was used for solving the nonlinear temperature distribution equation in solid and porous longitudinal fin with temperature dependent internal heat generation. The problem was solved for two main cases. In the first case, heat generation was assumed variable by fin temperature for a solid fin and in second heat generation varied with temperature for a porous fin. Results are presented for the temperature distribution for a range of values of parameters appearing in the mathematical formulation(e.g. N, εG, and G). Results reveal that DTM is very effective and convenient. Also, it is found that this method can achieve more suitable results in comparison to numerical methods.展开更多
A parabolic trough solar collector(PTSC)converts solar radiation into thermal energy.However,low thermal efficiency of PTSC poses a hindrance to the deployment of solar thermal power plants.Thermal performance of PTSC...A parabolic trough solar collector(PTSC)converts solar radiation into thermal energy.However,low thermal efficiency of PTSC poses a hindrance to the deployment of solar thermal power plants.Thermal performance of PTSC is enhanced in this study by incorporating magnetic nanoparticles into the working fluid.The circular receiver pipe,with dimensions of 66 mm diameter,2 mm thickness,and 24 m length,is exposed to uniform temperature and velocity conditions.The working fluid,Therminol-66,is supplemented with Fe3O4 magnetic nanoparticles at concentrations ranging from 1%to 4%.The findings demonstrate that the inclusion of nanoparticles increases the convective heat transfer coefficient(HTC)of the PTSC,with higher nanoparticle volume fractions leading to greater heat transfer but increased pressure drop.The thermal enhancement factor(TEF)of the PTSC is positively affected by the volume fraction of nanoparticles,both with and without a magnetic field.Notably,the scenario with a 4%nanoparticle volume fraction and a magnetic field strength of 250 G exhibits the highest TEF,indicating superior thermal performance.These findings offer potential avenues for improving the efficiency of PTSCs in solar thermal plants by introducing magnetic nanoparticles into the working fluid.展开更多
Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy s...Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy storage unit.In this study,the novel unequal-length fins are designed from the perspective of synergistic benefits of heat transfer and energy storage performance,and the effects of arrangement,number and total length of unequal-length fins are numerically investigated.Results show that utilization of fins with ascending length,when short and long fins are located in the inlet and outlet of heat transfer fluid respectively,can further promote the heat transfer and energy storage performance compared with equal length fins,and a maximum 6.17%and 0.43%increment of heat transfer performance and stored energy is achieved in full melting time,respectively.The number of unequal-length fins plays a major role in the energy storage,and 18.95%and 0.91%improvement of heat transfer performance and stored energy is realized when equipped with 2 unequal-length fins.A 21.17%improvement of the heat transfer performance is obtained when the total length of unequal-length fins is 18 mm.The present study is helpful to make further efforts to enhance heat transfer and energy storage of shell-and-tube latent heat thermal energy storage unit with unequal-length fins.展开更多
The present work relates to a numerical investigation of double diffusive mixed convection around a horizontal annulus with a finned inner cylinder.The solutal and thermal buoyancy forces are sustained by maintaining ...The present work relates to a numerical investigation of double diffusive mixed convection around a horizontal annulus with a finned inner cylinder.The solutal and thermal buoyancy forces are sustained by maintaining the inner and outer cylinders at uniform temperatures and concentrations.Buoyancy effects are also considered,with the Boussinesq approximation.The forced convection effect is induced by the outer cylinder rotating with an angular velocity(ω)in an anti-clockwise direction.The studies are made for various combinations of dimensionless numbers;buoyancy ratio number(N),Lewis number(Le),Richardson number(Ri)and Grashof number(Gr).The isotherms,isoconcentrations and streamlines as well as both average and local Nusselt and Sherwood numbers were studied.A finite volume scheme is adopted to solve the transport equations for continuity,momentum,energy and mass transfer.The results indicate that the use of fins on the inner cylinder with outer cylinder rotation,significantly improves the heat and mass transfer in the annulus.展开更多
Various enhanced surfaces have been proposed over the years to improve boiling heat transfer. This paper introduces an experimental setup designed for boiling demonstration in the graduate-level Heat Transfer course. ...Various enhanced surfaces have been proposed over the years to improve boiling heat transfer. This paper introduces an experimental setup designed for boiling demonstration in the graduate-level Heat Transfer course. The pool boiling performance of water under atmospheric pressure of 1.025 bar is investigated by using several structured surfaces at heat fluxes of 28 and 35 kW/m<sup>2</sup>. Surfaces with holes, rectangular grooves, and mushroom fins are manufactured by an NC-controlled vertical milling machine. The heat flux versus excess temperature graph is plotted by using thermocouple measurements of water and base temperatures of the boiling vessel. The separation, rise, and growth of individual vapor bubbles from the surface during boiling were recorded with a digital camera. The results for the plain surface are compared to the Rohsenow correlation. The enhancement of heat transfer coefficient (h) ranged between 15% - 44.5% for all structured surfaces. The highest heat transfer coefficient enhancement is observed between 41% - 56.5% for holed surface-3 (405 holes) compared to the plain surface. The excess temperature dropped around 29% - 34% for holed surface-3 (405 holes) compared to the plain surface. The heat transfer coefficient increases as the spacing between channels or holes decreases. While the bubbles on holed and mushroomed surfaces were spherical, the bubbles on the flat and grooved surfaces were observed as formless. The suggested economical test design could be appropriate to keep students focused and participating in the classroom.展开更多
This paper presents an experimental analysis of a single pass solar air collector with, and without using baffle fin. The heat transfer coefficient between the absorber plate and air can be considerably increased by u...This paper presents an experimental analysis of a single pass solar air collector with, and without using baffle fin. The heat transfer coefficient between the absorber plate and air can be considerably increased by using artificial roughness on the bottom plate and under the absorber plate of a solar air heater duct. An experimental study has been conducted to investigate the effect of roughness and operating parameters on heat transfer. The investigation has covered the range of Reynolds number Re from 1259 to 2517 depending on types of the configuration of the solar collectors. Based on the experimental data, values of Nusselt number Nu have been determined for different values of configurations and operating parameters. To determine the enhancement in heat transfer and increment in thermal efficiency, the values of Nusselt have been smooth duct under similar flow compared with those of conditions.展开更多
The typical configuration adopted by air-cooled condenser(ACC) in coal-fired power generating unit is the wave finned flat tube. The development of boundary layer between wave fins along long axis of flat tube can sup...The typical configuration adopted by air-cooled condenser(ACC) in coal-fired power generating unit is the wave finned flat tube. The development of boundary layer between wave fins along long axis of flat tube can suppress the air-side heat transfer enhancement to a great extent. It has been proved that the serrated fins can enhance heat transfer obviously by breaking the development of boundary layer periodically. In the present study,the discontinuous short wave fin was introduced to the flat tube to enhance the air-side heat transfer of ACC. Two different types of arrangements,i.e. staggered and in-line for discontinuous short wave fins on the flat tube,were designed. By numerical simulation,the heat transfer and flow performances of short wave fins were studied under different arrangements(in-line,staggered) ,and the influences on heat transfer and flow characteristics of rows of short wave fin and interrupted distance between discontinuous short wave fins were revealed numerically. The results indicated that,compared with the original continuous wave fin,the discontinuous short wave fin effectively improved the air-side heat transfer of flat tube under the air flow velocities in the practical application of engineering. Moreover,the increment of pressure loss of air-side flow was restricted for the discontinuous short wave fins because of the reduction of contact areas between the air flow and fin surface.展开更多
The design of thermal conductivity enhancers(TCE) is quite critical to overcoming the disadvantage of the poor thermal conductivity of phase change materials(PCM).The main contribution of this study is firstly to disc...The design of thermal conductivity enhancers(TCE) is quite critical to overcoming the disadvantage of the poor thermal conductivity of phase change materials(PCM).The main contribution of this study is firstly to discuss how to actively enhance natural convection of the melted PCM in cellular structure by the fin formed in the structure under the condition of the same metal mass,apart from simultaneously improving heat conduction,which can boost the heat transfer performance.Also,a tailored hybrid fin-lattice structure(HFS) as TCE is designed and fabricated by additive manufacturing(AM).A two-equation numerical method is applied to study the heat transfer of the PCM,and its feasibility is validated with the experimental data.The numerical results indicate that enhanced natural convection and improved heat conduction can be obtained simultaneously when a well-designed fin is embedded into a lattice structure.The enhanced natural convection results in the improved melting rate and the decreased wall temperature;e.g.,the complete melting time and the wall temperature are reduced by 11.6% and 19.7%,respectively,because of the fin for metal aluminum.Moreover,the parameters of HFS including the porosity,pore density,and fin dimension have a great impact on the heat transfer.The enhancement effect of the fin for HFS on the melting rate of the PCM increases as the thermal conductivity of the base material decreases.For example,when the fin is introduced into the lattice structure,the complete melting time is reduced by 24.1% for metal titanium.In summary,this study enables us to obtain a good understanding of the mechanism of the heat transfer and provides necessary experimental data for the structural design of HFS fabricated by AM.展开更多
In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat trans...In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.展开更多
An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of ...An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of the compound devices in the following configurations: (1) twisted tapes acted in the same direction (for co-swirl) while MF and twisted tapes acted in the same (parallel) direction (MF-CoDTs:P), (2) twisted tapes acted in the same direction (for co-swirl) while micro-fin tube and twisted tapes acted in opposite directions (MF-CoDTs:O) and (3) twisted tapes acted in opposite directions for counter swirl (MF-CDTs). The MF alone and the MF equipped with a single twisted tape in parallel/opposite arrangement were also considered for comparison. The experiments were conducted for the flows with the Reynolds numbers between 5 650 and 17 000, under uniform heat flux condition. The experimental results indicate that MF-CDTs induce stronger swirl/turbulence flow, resulting in higher heat transfer rate, friction factor and thermal performance factor than other combined devices. The thermal performance factors associated with the use of MF-CDTs were found to be higher than those associated with the uses of MF-CoDTs:P, MF-CoDTs:O and MF alone up to 9.3%, 6.5% and 56.4%, respectively. The empirical correlations developed using the present experimental data for the Nusselt number, friction factor and thermal performance factor are also reported.展开更多
文摘Forced convection cooling of fins on a high-temperature wall has been used to cool high-power electronic devices. We numerically calculated and experimentally measured the forced convection heat transfer coefficient and pressure drop of a diamond-shaped fin-array with water flow in this study, which had been reported to have a self-induced flip-flop flow phenomenon. Although the flip-flop flow phenomenon occurred in calculations, it was not observed in experiments. The heat transfer and pressure drop of the diamond-shaped fin-array could be estimated with equations for turbulent flow in tubes.
文摘This study examines the heat transfer enhancement from a horizontal rectangular fin embedded with triangular perforations (their bases parallel and toward the fin tip) under natural convection. The fin's heat dissipation rate is compared to that of an equivalent solid one. The parameters considered are geometrical dimensions and thermal properties of the fin and the perforations. The gain in the heat transfer enhancement and the fin weight reduction due to the perforations are considered. The study shows that the heat dissipation from the perforated fin for a certain range of triangular perforation dimensions and spaces between perforations result in improvement in the heat transfer over the equivalent solid fin. The heat transfer enhancement of the perforated fin increases as the fin thermal conductivity and its thickness are increased.
文摘Fins are used for enhancement of heat transfer. Triangular fins are arranged in form of nozzle and heat transfer coefficient is calculated. Angle of taper of nozzle is changed i.e. angles of triangles are varied and then heat transfer coefficient is calculated. Total finned area of all fins is almost the same. Number of fins and orientation of fins are different. In this study to calculate heat transfer coefficient of unfinned area open channel is considered where density and pressure are constant. This study shows that heat transfer is enhanced by 213%, 268% and 339% using 30°, 45° and 60° fins. Computational results show that heat transfer is enhanced by 108%, 130%, 146% using 30°, 45° and 60° fins.
基金Supported by the National Natural Science Foundation of China(51276090)
文摘Experimental investigation is conducted to investigate the flow and heat transfer performances of jet impingement cooling inside a semi-confined smooth channel.Effects of jet Reynolds number(varied from 10 000to 45000),orifice-to-target spacing(zn=1d—4d)and jet-to-jet pitches(xn=3d—5d,yn=3d—5d)on the convective heat transfer coefficient and discharge coefficient are revealed.For a single-row jets normal impingement,the impingement heat transfer is enhanced with the increase of impingement Reynolds number or the decrease of spanwise jet-to-jet pitch.The highest local heat transfer is achieved when zn/dis 2.For the double-row jets normal impingement,the laterally-averaged Nusselt number distributions in the vicinity of the first row jets impinging stagnation do not fit well with the single-row case.The highest local heat transfer is obtained when zn/dis 1.A smaller jetto-jet pitch generally results in a lower discharge coefficient.The discharge coefficient in the double-row case is decreased relative to the single-row case at the same impingement Reynolds number.
基金The Fundamental Research Funds for the Central Universities,China
文摘Considering the limitation in current manufacturing technology of commercial pin fin heat sinks,a new fabric heat sink has been designed. However,it is lack of an understanding of the heat transferring performance of this new kind of heat sink. In this study,the finite element method (FEM) was used to predict the heat transferring performance of fabric heat sink under the condition of natural convection and forced convection, and its heat transferring performance was compared with that of pin fin heat sink. The results showed that in the condition of natural convection the heat transferring performance of pin fin heat sink was better than that of fabric heat sink, and vice versa under the forced convection condition.
文摘Development and use of nuclear energy is currently growing very rapidly, in order to achieve increasingly advanced technology, both in terms of design, economic factors and safety factors. Thermal-hydraulics aspects of nuclear reactors should be done with calculation and near-perfect condition. Including today began development of a nuclear reactor with low power below 300 MW, or commonly called the Small Modular Reactor (SMR). One is CAREM-25 developed by Argentina with a power of 25 MW, where in CAREM already using natural circulation system and the use of nanofluid as coolant fluid. In this research, analytic modeling of thermal-hydraulics nuclear reactor SMR CAREM-25, when the nanofluid Al<sub>2</sub>O<sub>3</sub>-Water used as cooling fluid in the cooling system of a nuclear reactor. Further to this analytic modeling will be done on CFD. Analytic modeling with CFD to determine the flow phenomena and distribution as well as the effect of nano-particles of Al<sub>2</sub>O<sub>3</sub>-Water based on the volume fraction (1% and 3%) of the coefficient of heat transfer by natural convection.
基金Project(50976022) supported by the National Natural Science Foundation of ChinaProject(BY2011155) supported by the Provincial Science and Technology Innovation and Transformation of Achievements of Special Fund Project of Jiangsu Province,China
文摘Numerical computation models of air cooling heat transfer and flow behaviors in triangular wavy fin channels(TWFC) were established with structural parameters of fins considered.The air side properties of heat transfer coefficient and pressure drop are displayed with variable structural parameters of fins and inlet velocities of cooling air.Within the range of simulation,TWFC has the best comprehensive performance when inlet velocity vin=4-10 m/s.Compared with those of straight fins,the simulation results reveal that the triangular wavy fin channels are of higher heat transfer performances especially with the fin structural parameters of fin-height Fh=9.0 mm,fin-pitch Fp=2.5-3.0 mm,fin-wavelength λ=14.0-17.5 mm and fin-wave-amplitude A=1.0-1.2 mm.The correlations of both heat transfer factor and friction factor are presented,and the deviations from the experimental measurements are within 20%.
文摘The special formulation that allows an accurate and efficient solution to the heat transfer problems within fin assemblies with very large aspect ratios has been developed in this paper Numerically,it consists of the boundary element method in the wall region and the analytical solution in the fin region This modified BEM makes tractable a large class of heat transfer problems in the long and thin domains which are frequently encountered in practice.
基金Sponsored by the National Natural Science Special Foundation of China(Grant No.50323001)Xi'an Jiaotong University Doctoral Foundation forTeacher.
文摘Presents a set of data for flow and heat transfer of finned-tube bundle under the condition of high air flow velocity. Air flow and heat transfer over a 4×4 (columns×rows) finned-tube heat exchanger with rectangular fins was investigated experimentally in a wind tunnel with constant wall temperatures condition. The air flow velocity based on the minimum flow cross-section area over flow channel ranged from 13.8 to 50.2 m/s, the heat transfer rate ranged from 21.8 to 47.1 kW, and the air temperatures increase ranged from 10.9 to 19.8 ℃. The present results were compared with results calculated from correlations proposed by CSPE. For air flow velocity less than 25 m/s, these two results of heat transfer agreed well with each other, whereas for larger velocity, our test data disagreed with the CSPE correlauions. For the friction factor, present data are much higher than the predicted results in the whole range. Finally, correlations for friction factors and heat transfer coefficients are proposed based on the experimental results.
文摘A simple and highly accurate semi-analytical method, called the differential transformation method(DTM), was used for solving the nonlinear temperature distribution equation in solid and porous longitudinal fin with temperature dependent internal heat generation. The problem was solved for two main cases. In the first case, heat generation was assumed variable by fin temperature for a solid fin and in second heat generation varied with temperature for a porous fin. Results are presented for the temperature distribution for a range of values of parameters appearing in the mathematical formulation(e.g. N, εG, and G). Results reveal that DTM is very effective and convenient. Also, it is found that this method can achieve more suitable results in comparison to numerical methods.
文摘A parabolic trough solar collector(PTSC)converts solar radiation into thermal energy.However,low thermal efficiency of PTSC poses a hindrance to the deployment of solar thermal power plants.Thermal performance of PTSC is enhanced in this study by incorporating magnetic nanoparticles into the working fluid.The circular receiver pipe,with dimensions of 66 mm diameter,2 mm thickness,and 24 m length,is exposed to uniform temperature and velocity conditions.The working fluid,Therminol-66,is supplemented with Fe3O4 magnetic nanoparticles at concentrations ranging from 1%to 4%.The findings demonstrate that the inclusion of nanoparticles increases the convective heat transfer coefficient(HTC)of the PTSC,with higher nanoparticle volume fractions leading to greater heat transfer but increased pressure drop.The thermal enhancement factor(TEF)of the PTSC is positively affected by the volume fraction of nanoparticles,both with and without a magnetic field.Notably,the scenario with a 4%nanoparticle volume fraction and a magnetic field strength of 250 G exhibits the highest TEF,indicating superior thermal performance.These findings offer potential avenues for improving the efficiency of PTSCs in solar thermal plants by introducing magnetic nanoparticles into the working fluid.
基金This investigation was financially supported by the National Science Foundation of China(NSFC)(No.52078110)the Natural Science Foundation of Heilongjiang Province(No.LH2019E015)the Scientific Project of Ministry of Housing and Urban-Rural Development of China(No.2020-K-184,No.2021-K-160).
文摘Previous studies in literatures adequately emphasized that inserting fins into phase change material is among the most promising techniques to augment thermal performance of shell-and-tube latent heat thermal energy storage unit.In this study,the novel unequal-length fins are designed from the perspective of synergistic benefits of heat transfer and energy storage performance,and the effects of arrangement,number and total length of unequal-length fins are numerically investigated.Results show that utilization of fins with ascending length,when short and long fins are located in the inlet and outlet of heat transfer fluid respectively,can further promote the heat transfer and energy storage performance compared with equal length fins,and a maximum 6.17%and 0.43%increment of heat transfer performance and stored energy is achieved in full melting time,respectively.The number of unequal-length fins plays a major role in the energy storage,and 18.95%and 0.91%improvement of heat transfer performance and stored energy is realized when equipped with 2 unequal-length fins.A 21.17%improvement of the heat transfer performance is obtained when the total length of unequal-length fins is 18 mm.The present study is helpful to make further efforts to enhance heat transfer and energy storage of shell-and-tube latent heat thermal energy storage unit with unequal-length fins.
文摘The present work relates to a numerical investigation of double diffusive mixed convection around a horizontal annulus with a finned inner cylinder.The solutal and thermal buoyancy forces are sustained by maintaining the inner and outer cylinders at uniform temperatures and concentrations.Buoyancy effects are also considered,with the Boussinesq approximation.The forced convection effect is induced by the outer cylinder rotating with an angular velocity(ω)in an anti-clockwise direction.The studies are made for various combinations of dimensionless numbers;buoyancy ratio number(N),Lewis number(Le),Richardson number(Ri)and Grashof number(Gr).The isotherms,isoconcentrations and streamlines as well as both average and local Nusselt and Sherwood numbers were studied.A finite volume scheme is adopted to solve the transport equations for continuity,momentum,energy and mass transfer.The results indicate that the use of fins on the inner cylinder with outer cylinder rotation,significantly improves the heat and mass transfer in the annulus.
文摘Various enhanced surfaces have been proposed over the years to improve boiling heat transfer. This paper introduces an experimental setup designed for boiling demonstration in the graduate-level Heat Transfer course. The pool boiling performance of water under atmospheric pressure of 1.025 bar is investigated by using several structured surfaces at heat fluxes of 28 and 35 kW/m<sup>2</sup>. Surfaces with holes, rectangular grooves, and mushroom fins are manufactured by an NC-controlled vertical milling machine. The heat flux versus excess temperature graph is plotted by using thermocouple measurements of water and base temperatures of the boiling vessel. The separation, rise, and growth of individual vapor bubbles from the surface during boiling were recorded with a digital camera. The results for the plain surface are compared to the Rohsenow correlation. The enhancement of heat transfer coefficient (h) ranged between 15% - 44.5% for all structured surfaces. The highest heat transfer coefficient enhancement is observed between 41% - 56.5% for holed surface-3 (405 holes) compared to the plain surface. The excess temperature dropped around 29% - 34% for holed surface-3 (405 holes) compared to the plain surface. The heat transfer coefficient increases as the spacing between channels or holes decreases. While the bubbles on holed and mushroomed surfaces were spherical, the bubbles on the flat and grooved surfaces were observed as formless. The suggested economical test design could be appropriate to keep students focused and participating in the classroom.
文摘This paper presents an experimental analysis of a single pass solar air collector with, and without using baffle fin. The heat transfer coefficient between the absorber plate and air can be considerably increased by using artificial roughness on the bottom plate and under the absorber plate of a solar air heater duct. An experimental study has been conducted to investigate the effect of roughness and operating parameters on heat transfer. The investigation has covered the range of Reynolds number Re from 1259 to 2517 depending on types of the configuration of the solar collectors. Based on the experimental data, values of Nusselt number Nu have been determined for different values of configurations and operating parameters. To determine the enhancement in heat transfer and increment in thermal efficiency, the values of Nusselt have been smooth duct under similar flow compared with those of conditions.
基金supported by the National Basic Research Program of China ("973" Program) (Grant No.2009CB219804)
文摘The typical configuration adopted by air-cooled condenser(ACC) in coal-fired power generating unit is the wave finned flat tube. The development of boundary layer between wave fins along long axis of flat tube can suppress the air-side heat transfer enhancement to a great extent. It has been proved that the serrated fins can enhance heat transfer obviously by breaking the development of boundary layer periodically. In the present study,the discontinuous short wave fin was introduced to the flat tube to enhance the air-side heat transfer of ACC. Two different types of arrangements,i.e. staggered and in-line for discontinuous short wave fins on the flat tube,were designed. By numerical simulation,the heat transfer and flow performances of short wave fins were studied under different arrangements(in-line,staggered) ,and the influences on heat transfer and flow characteristics of rows of short wave fin and interrupted distance between discontinuous short wave fins were revealed numerically. The results indicated that,compared with the original continuous wave fin,the discontinuous short wave fin effectively improved the air-side heat transfer of flat tube under the air flow velocities in the practical application of engineering. Moreover,the increment of pressure loss of air-side flow was restricted for the discontinuous short wave fins because of the reduction of contact areas between the air flow and fin surface.
基金the National Natural Science Foundation of China (Grant No.11972105,U1808215 and 11821202)the 111 Project (B14013)the Fundamental Research Funds for the Central Universities of China。
文摘The design of thermal conductivity enhancers(TCE) is quite critical to overcoming the disadvantage of the poor thermal conductivity of phase change materials(PCM).The main contribution of this study is firstly to discuss how to actively enhance natural convection of the melted PCM in cellular structure by the fin formed in the structure under the condition of the same metal mass,apart from simultaneously improving heat conduction,which can boost the heat transfer performance.Also,a tailored hybrid fin-lattice structure(HFS) as TCE is designed and fabricated by additive manufacturing(AM).A two-equation numerical method is applied to study the heat transfer of the PCM,and its feasibility is validated with the experimental data.The numerical results indicate that enhanced natural convection and improved heat conduction can be obtained simultaneously when a well-designed fin is embedded into a lattice structure.The enhanced natural convection results in the improved melting rate and the decreased wall temperature;e.g.,the complete melting time and the wall temperature are reduced by 11.6% and 19.7%,respectively,because of the fin for metal aluminum.Moreover,the parameters of HFS including the porosity,pore density,and fin dimension have a great impact on the heat transfer.The enhancement effect of the fin for HFS on the melting rate of the PCM increases as the thermal conductivity of the base material decreases.For example,when the fin is introduced into the lattice structure,the complete melting time is reduced by 24.1% for metal titanium.In summary,this study enables us to obtain a good understanding of the mechanism of the heat transfer and provides necessary experimental data for the structural design of HFS fabricated by AM.
基金supported by the National Key R&D Program of China(No. 2020YFB1901405)
文摘In loss-of-coolant accidents,a passive containment heat removal system protects the integrity of the containment by condensing steam.As a large amount of air exists in the containment,the steam condensation heat transfer can be significantly reduced.Based on previous research,traditional methods for enhancing pure steam condensation may not be applicable to steam–air condensation.In the present study,new methods of enhancing condensation heat transfer were adopted and several potentially enhanced heat transfer tubes,including corrugated tubes,spiral fin tubes,and ring fin tubes were designed.STAR-CCM+was used to determine the effect of enhanced heat transfer tubes on the steam condensation heat transfer.According to the calculations,the gas pressure ranged from 0.2 to 1.6 MPa,and air mass fraction ranged from 0.1 to 0.9.The effective perturbation of the high-concentration air layer was identified as the key factor for enhancing steam–air condensation heat transfer.Further,the designed corrugated tube performed well at atmospheric pressure,with a maximum enhancement of 27.4%,and performed poorly at high pressures.In the design of spiral fin tubes,special attention should be paid to the locations that may accumulate high-concentration air.Nonetheless,the ring-fin tubes generally displayed good performance under all conditions of interest,with a maximum enhancement of 24.2%.
基金the Thailand Research Fund (TRF),Office of Higher Education Commission and Mahanakorn University of Technology (MUT) for financial support of this research(Grant No.MRG5480026)
文摘An experimental study was carried out to investigate the influence of double twisted-tape inserts (DTs) in micro-fin tubes (MFs) on heat transfer, friction factor and thermal performance factor characteristics of the compound devices in the following configurations: (1) twisted tapes acted in the same direction (for co-swirl) while MF and twisted tapes acted in the same (parallel) direction (MF-CoDTs:P), (2) twisted tapes acted in the same direction (for co-swirl) while micro-fin tube and twisted tapes acted in opposite directions (MF-CoDTs:O) and (3) twisted tapes acted in opposite directions for counter swirl (MF-CDTs). The MF alone and the MF equipped with a single twisted tape in parallel/opposite arrangement were also considered for comparison. The experiments were conducted for the flows with the Reynolds numbers between 5 650 and 17 000, under uniform heat flux condition. The experimental results indicate that MF-CDTs induce stronger swirl/turbulence flow, resulting in higher heat transfer rate, friction factor and thermal performance factor than other combined devices. The thermal performance factors associated with the use of MF-CDTs were found to be higher than those associated with the uses of MF-CoDTs:P, MF-CoDTs:O and MF alone up to 9.3%, 6.5% and 56.4%, respectively. The empirical correlations developed using the present experimental data for the Nusselt number, friction factor and thermal performance factor are also reported.