期刊文献+
共找到52,622篇文章
< 1 2 250 >
每页显示 20 50 100
Finite Element Analysis of Coronal Shear Fractures of the Femoral Neck: Displacement of the Femoral Head and Effect of Osteosynthetic Implants
1
作者 Yukino Mori Hiroaki Kijima +2 位作者 Mei Terashi Takehiro Iwami Naohisa Miyakoshi 《World Journal of Engineering and Technology》 2024年第3期651-664,共14页
Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynt... Coronal shear fractures of the femoral neck (CSFF) are the most challenging to treat among proximal femur fractures, directly affecting the life expectancy of patients with osteoporosis. However, an adequate osteosynthesis method has not been elucidated yet. This study investigated the displacement direction of the femoral head fragment and its effect on the bone using finite element method. A finite element model for CSFF was developed from CT image data of a patient with osteoporosis using Mechanical Finder (ver. 11). Subsequently, finite element analyses were performed on six osteosynthesis models under maximum load applied during walking. The compressive stresses, tensile stresses, and compressive strains of each model were examined. The results suggested that the compressive and tensile stress distributions were concentrated on the anterior side of the femoral neck. Compressive strain distribution in the femoral head and neck was concentrated in four areas: at the tip of the blade or lag screw, the anteroinferior side of the blade or lag screw near the fracture site, and the upper right and lower left near the junction of the blade or lag screw and nail. Thus, the distribution of both these stresses revealed that the femoral head fragment was prone to anterior and inferior displacement. Distribution of compressive strains revealed the direction of the stress exerted by the osteosynthetic implant on the bone. The same results were observed in all osteosynthetic implants;thus, the findings could lay the foundation for developing methods for placing osteosynthetic implants less prone to displacement and the osteosynthetic implants themselves. In particular, the study provides insight into the optimal treatment of CSFF. 展开更多
关键词 finite element analysis Proximal femur Fractures Intramedullary Fixation Coronal Shear Fractures femoral Neck
下载PDF
Collapse Behavior of Pipe-Framed Greenhouses with and without Reinforcement under Snow Loading:A 3-D Finite Element Analysis
2
作者 Yasushi Uematsu Kazuya Takahashi 《Journal of Civil Engineering and Architecture》 2024年第2期51-59,共9页
The present paper first investigates the collapse behavior of a conventional pipe-framed greenhouse under snow loading based on a 3-D finite element analysis,in which both geometrical and material non-linearities are ... The present paper first investigates the collapse behavior of a conventional pipe-framed greenhouse under snow loading based on a 3-D finite element analysis,in which both geometrical and material non-linearities are considered.Three snow load distribution patterns related to the wind-driven snow particle movement are used in the analysis.It is found that snow load distribution affects the deformation and collapse behavior of the pipe-framed greenhouse significantly.The results obtained in this study are consistent with the actual damage observed.Next,discussion is made of the effects of reinforcements by adding members to the basic frame on the strength of the whole structure,in which seven kinds of reinforcement methods are examined.A buckling analysis is also carried out.The results indicate that the most effective reinforcement method depends on the snow load distribution pattern. 展开更多
关键词 Pipe-framed greenhouse snow loading COLLAPSE BUCKLING finite element analysis
下载PDF
Stress Distributions Created by Short and Regular Implants Placed in the Anterior Maxilla at Different Angles: A Finite Element Analysis
3
作者 Mehmet Fatih Özmen Funda Bayındır 《Open Journal of Stomatology》 2023年第1期32-49,共18页
Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The... Although short implants are seen as alternative treatments that require additional surgical techniques in posterior region, they can be applied to anterior maxilla and various studies are required on this subject. The purpose of this study was to examine and compare the peak von Mises stress distributions in the crown, implant and abutment by using finite element analysis (FEA). Besides, a comparison of the implant-abutment connection types in the short implant with the FEA method was established. A short implant (4 × 5 mm) with a taper-lock connection and a regular implant (4 × 9 mm) with a screw connection were used in maxillary central incisor tooth area. Three different titanium abutments with 0?, 15? and 25? angles were used for abutments. In addition, in order to determine whether the stress change in short implants is due to the length of the implant-abutment connection, a screw was designed for a short implant and it was also evaluated in the same three angles. A total of three groups and nine models were generated. 114.6N load was applied to the cingulum area of the crown at an angle of 135? to the long axis of the crowns. A torque load of 25 Ncm was applied to the regular and short implant screw. Von Mises stress distributions of implants, abutments and crowns were evaluated by using FEA. Increased angle in implants increased von Mises stress values of implant, abutment and crown. Screw connection was found higher at all angles in short implants. Close values were found at different angles in taper-lock short implant crowns. The length and the angle in the bone of implant with the type of implant-abutment connection results in the accumulated stress values. Clinical Implications Taper implant-abutment connection system was found to be more promising in terms of stress accumulation in crowns. Although the amount of stress on the abutment increased due to the length of the implant in short implants, taper implant-abutment connection system slightly reduced related to this increase. 展开更多
关键词 Anterior Maxilla finite element analysis Von Mises Short Implant
下载PDF
Modal and Thermal Analysis of a Modified Connecting Rod of an Internal Combustion Engine Using Finite Element Method
4
作者 Nkrumah Jacob Kwaku Baba Ziblim +1 位作者 Sulemana Yahaya Sherry Kwabla Amedorme 《Modeling and Numerical Simulation of Material Science》 2023年第3期29-49,共21页
The connecting rod is one of the most important moving components in an internal combustion engine. The present work determined the possibility of using aluminium alloy 7075 material to design and manufacture a connec... The connecting rod is one of the most important moving components in an internal combustion engine. The present work determined the possibility of using aluminium alloy 7075 material to design and manufacture a connecting rod for weight optimisation without losing the strength of the connecting rod. It considered modal and thermal analyses to investigate the suitability of the material for connecting rod design. The parameters that were considered under the modal analysis were: total deformation, and natural frequency, while the thermal analysis looked at the temperature distribution, total heat flux and directional heat flux of the four connecting rods made with titanium alloy, grey cast iron, structural steel and aluminium 7075 alloy respectively. The connecting rod was modelled using Autodesk inventor2017 software using the calculated parameters. The steady-state thermal analysis was used to determine the induced heat flux and directional heat flux. The study found that Aluminium 7075 alloy deformed more than the remaining three other materials but has superior qualities in terms of vibrational natural frequency, total heat flux and lightweight compared to structural steel, grey cast iron and titanium alloy. 展开更多
关键词 Connecting Rod Steady-State Thermal analysis DEFORMATION Heat Flux Thermal and Modal finite element Method
下载PDF
Study on Development of Light Aluminum Step by Using Finite Element Analysis
5
作者 WU Jianlong 《International Journal of Plant Engineering and Management》 2023年第4期232-248,共17页
In order to ensure the safe operation of the escalator,the step as a part of transporting passengers,the design will consider a high safety factor,which will increase the weight,the manufacturing cost,and the energy c... In order to ensure the safe operation of the escalator,the step as a part of transporting passengers,the design will consider a high safety factor,which will increase the weight,the manufacturing cost,and the energy consumption of the steps band operation.Therefore,in order to reduce the weight and ensure the strength and stiffness of the step,through the optimization design,the number of reinforcing rib supports of the step tread plate and riser plate is increased,and the thickness of the step tread plate and riser plate is moderately reduced,so as to achieve the purpose of reducing the weight of the step and reducing the manufacturing cost and operating energy consumption.Through the finite element analysis and testing of the new type step design,Its strength and stiffness fully meet the requirements of GB 16899-2011 and EN 115-1:2017 standards,and the breaking force also meets the industry standards,so that the manufacturing and operating costs of the product can be reduced to improve the competitiveness of the product market. 展开更多
关键词 light aluminum step DEVELOPMENT finite element analysis
下载PDF
Cracking analysis of fracture mechanics by the finite element method of lines(FEMOL) 被引量:2
6
作者 Shaowei Hu Brian Moran 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2005年第5期495-502,共8页
The Finite Element Method of Lines (FEMOL) is a semi-analytic approach and takes a position between FEM and analytic methods. First, FEMOL in Fracture Mechanics is presented in detail. Then, the method is applied to... The Finite Element Method of Lines (FEMOL) is a semi-analytic approach and takes a position between FEM and analytic methods. First, FEMOL in Fracture Mechanics is presented in detail. Then, the method is applied to a set of examples such as edge-crack plate, the central-crack plate, the plate with cracks emanating from a hole under tensile or under combination loads of tensile and bending. Their dimensionless stress distribution, the stress intensify factor (SIF) and crack opening displacement (COD) are obtained, and comparison with known solutions by other methods are reported. It is found that a good accuracy is achieved by FEMOL. The method is successfully modified to remarkably increase the accuracy and reduce convergence difficulties. So it is a very useful and new tool in studying fracture mechanics problems. 展开更多
关键词 The finite element method of lines femOL) .Cracking analysis . Application
下载PDF
Optimal Design Strategies of Femur Tumor Hyperthermia Based on Finite Element Analysis of Temperature Field
7
作者 Monan Wang Lei Sun 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2015年第4期121-128,共8页
A 3D femoral model was built to obtain the three-dimensional temperature distribution of femur and its surrounding tissues and provide references for clinical applications. According to the relationship between gray-v... A 3D femoral model was built to obtain the three-dimensional temperature distribution of femur and its surrounding tissues and provide references for clinical applications. According to the relationship between gray-value and material properties,the model was assigned with various materials to make sure that it is more similar to the real femur in geometry and physical properties. 3D temperature distribution is obtained by using finite element analysis software ANSYS 11. 0 on the basis of heat conduction theory,Laplace equation,Pennes bio-heat transfer equation,thermo physical parameters of bone tissues,the boundary condition,and initial conditions. Taken the asymmetry of the 3D distribution of temperature into account,it is necessary to adopt the heating method with multiple heat sources. This method can ensure that the temperature fields match well with the tumor tissues and kill the tumor cells efficiently under the condition of protecting the normal tissues from damage. The analysis results supply important guidance for determining the needle position and the needle number and controlling the intensity of heating. 展开更多
关键词 femUR tumor hyperthermia 3D temperature fields finite element analysis
下载PDF
Relationships between femoral strength evaluated by nonlinear finite element analysis and BMD,material distribution and geometric morphology
8
作者 He Gong1,Linwei Lv1,Rui Zhang1,Dong Zhu3,Ming Zhang2(1.Department of Engineering Mechanics,Jilin University,Changchun 130025,P.R.China 2.Department of Health Technology and Informatics,The Hong Kong Polytechnic University,Hong Kong,China 3.Department of Orthopedic Surgery,No.1 Hospital,Jilin University,Changchun 130021,China) 《医用生物力学》 EI CAS CSCD 2009年第S1期66-66,共1页
Precisely quantifying the strength of the proximal femur and accurately assessing hip fracture risk would enable those at high risk to be identified so that preventive interventions could be taken.Development of bette... Precisely quantifying the strength of the proximal femur and accurately assessing hip fracture risk would enable those at high risk to be identified so that preventive interventions could be taken.Development of better measures of femoral strength using the clinically 展开更多
关键词 BMD Relationships between femoral strength evaluated by nonlinear finite element analysis and BMD material distribution and geometric morphology FEA
下载PDF
Finite element failure analysis of continuous prestressed concrete box girders 被引量:4
9
作者 张峰 李术才 +2 位作者 李树忱 叶见曙 雷笑 《Journal of Southeast University(English Edition)》 EI CAS 2009年第2期236-240,共5页
In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a... In order to analyze the load carrying capacity of prestressed concrete box girders, failure behaviors of in-situ deteriorated continuous prestressed concrete box girders under loading are experimentally observed and a finite failure analysis method for predicting behaviors of box girders is developed. A degenerated solid shell element is used to simulate box girders and material nonlinearity is considered. Since pre-stressed concrete box girders usually have a large number of curve prestressed tendons, a type of combined element is presented to simulate the prestressed tendons of box girders, and then the number of elements can be significantly reduced. The analytical results are compared with full-scale failure test results. The comparison shows that the presented method can be effectively applied to the failure analysis of in-situ continuous prestressed concrete box girders, and it also shows that the studied old bridge still has enough load carrying capacity. 展开更多
关键词 full-scale failure test prestressed concrete box girder finite element analysis combined element prestressed tendon load carrying capacity
下载PDF
Finite element analysis of stress at implant-bone interface of dental implants with different structures 被引量:3
10
作者 陈良建 何浩 +3 位作者 李益民 李挺 郭小平 汪瑞芳 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2011年第7期1602-1610,共9页
The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element model... The effect of structure,elastic modulus and thickness of lower modulus layer in porous titanium implants on the stress distribution at the implant-bone interface was investigated.Three-dimensional finite element models of different titanium implants were constructed.The structures of the implants included the whole lower modulus style (No.1),bio-mimetic style (No.2),the whole lower modulus style in cancellous bone (No.3) and the whole dense style No.4.The stress distributions at bone-implant interface under static loading were analyzed using Ansys Workbench 10.0 software.The results indicated that the distribution of interface stress is strongly depended on the structure of the implants.The maximum stresses in cancellous bone and root region of implant No.2 are lower than those in the other three implants.A decrease in the modulus of the low modulus layer facilitates the interface stress transferring.Increasing the thickness of the low modulus layer can reduce the stress and induce a more uniform stress distribution at the interface.Among the four implants,biomimetic style implant No.2 is superior in transferring implant-bone interface stress to surrounding bones. 展开更多
关键词 titanium implant elastic modulus finite element analysis porous structure
下载PDF
3D Finite Element Analysis of a Man Hip Joint Femur under Impact Loads
11
作者 YU Xue-zhong GUO Yi-mu +2 位作者 LI Jun ZHANG Yun-qiu HE Rong-xin 《Chinese Journal of Biomedical Engineering(English Edition)》 2007年第1期1-7,共7页
Objective: The biomechanical characters of the bone fracture of the man femoral hip joint under impact loads are explored. Methods :A biosystem model of the man femoral hip joint by using the GE ( General Electric... Objective: The biomechanical characters of the bone fracture of the man femoral hip joint under impact loads are explored. Methods :A biosystem model of the man femoral hip joint by using the GE ( General Electric) lightspeed multi-lay spiral CT is conducted. A 3D finite element model is established by employing the finite element software ANSYS. The FE analysis mainly concentrates on the effects of the impact directions arising from intense movements and the parenchyma on the femoral hip joint on the stress distributions of the proximal femur. Results:The parenchyma on the hip joint has relatively large relaxation effect on the impact loads. Conclusion:Effects of the angle δ of the impact load to the anterior direction and the angle γ of the impact load to the femur shaft on the bone fracture are given;δ has larger effect on the stress and strain distributions than the angle γ,which mainly represents the fracture of the upper femur including the femoral neck fracture when the posterolateral femur is impacted, consistent with the clinical resuits. 展开更多
关键词 femoral hip joint Impact loading 3 D finite element analysis
下载PDF
Finite element simulation and optimal analysis of surfacing on steel orthotropic bridge deck 被引量:2
12
作者 谭积青 徐伟 张肖宁 《Journal of Southeast University(English Edition)》 EI CAS 2006年第4期539-543,共5页
To analyze the stress state of steel orthotropic deck pavement and provide reference for the design of the overlay, the inner stress state and strain distribution of surfacing under the load of the deformation of the ... To analyze the stress state of steel orthotropic deck pavement and provide reference for the design of the overlay, the inner stress state and strain distribution of surfacing under the load of the deformation of the whole bridge structure and tyre load are analyzed by the finite element method of submodeling. Influence of surfacing modulus on the strain state of the overlay is analyzed for the purpose of the optimal design of the overlay structure. Analysis results show that the deformation of the whole bridge structure has no evident influence on the stress state of the overlay. The key factor of the overlay design is the transverse tensile strain in the overlay above the upper edge of web plate of rib. The stress state of the overlay is influenced evidently by the modulus of rigidity transform overlay. And the stress state of the overlay can be optimized and lowered by increasing the modulus and thickness of rigidity transform overlay, The fatigue test has been done to evaluate the fatigue performance and modulus of different deck pavement materials such as epoxy asphalt, SBS modified asphalt, rosphalt asphalt which can provide reference for deck pavement structure design. 展开更多
关键词 steel orthotropic deck bridge deck overlay finite element submodeling optimal analysis fatigue test
下载PDF
Finite element analysis of the Taizhou Water Station Site 被引量:2
13
作者 潘建伍 淳庆 《Journal of Southeast University(English Edition)》 EI CAS 2013年第3期289-293,共5页
The Taizhou Water Station Site is an ancient masonry structure ruin built in the Southern Song Dynasty. The main structure was severely damaged. In order to understand its current structural properties and provide a s... The Taizhou Water Station Site is an ancient masonry structure ruin built in the Southern Song Dynasty. The main structure was severely damaged. In order to understand its current structural properties and provide a scientific basis for protection design nonlinear finite element analysis and parameter analysis are carried out.The crack patterns deformations and stresses of the main structure under four load cases are analyzed by nonlinear finite element analysis and the effect of the backfill bulk density and modulus on the maximum principal tensile stress and maximum compressive stress are studied by parameter analysis.The results show that the most unfavorable condition for the foundation is the combination of weight+backfill soil pressure+additional load the most unfavorable load case to the main structure is weight +backfill soil pressure +water pressure+additional heap load the maximum principal tensile stress of the main structure is very sensitive to the changes in the bulk density of the backfill soil. 展开更多
关键词 finite element analysis Taizhou Water StationSite ancient masonry structure
下载PDF
Modeling Technology in Finite Element Analysis of Electrostatic Proximity Fuze Problem 被引量:2
14
作者 李银林 施聚生 《Journal of Beijing Institute of Technology》 EI CAS 2000年第3期286-290,共5页
In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object a... In order to analyze the electrostatic field concerned with electrostatic proximity fuze problem using the available finite analysis software package, the technology to model the problem with a scale reduction object and boundary was presented. The boundary is determined by the maximum distance the sensor can detect. The object model is obtained by multiplying the terms in Poisson's equation with a scale reduction factor and the real value can be reconstructed with the same reverse process after software calculation. Using the finite element analysis program, the simulation value is close to the theoretical value with a little error. The boundary determination and scale reduction method is suitable to modeling the irregular electrostatic field around air targets, such as airplane, missile and so on, which is based on commonly used personal computer (PC). The technology reduces the calculation and storage cost greatly. 展开更多
关键词 electrostatic proximity fuze finite element analysis boundary condition scale reduction method
下载PDF
ALE FINITE ELEMENT ANALYSIS OF NONLINEAR SLOSHING PROBLEMS BASED ON F LUID VELOCITY POTENTIAL 被引量:1
15
作者 陈建平 周儒荣 万水 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第1期23-29,共7页
Base d on fluid velocity potential, an ALE finite element formulation for the analysi s of nonlinear sloshing problems has been developed. The ALE kinemat ical description is introduced to move the computational mesh... Base d on fluid velocity potential, an ALE finite element formulation for the analysi s of nonlinear sloshing problems has been developed. The ALE kinemat ical description is introduced to move the computational mesh independently of f luid motion, and the container fixed noninertial coordinate system is employed to establish the governing equations so that the mesh is needed to be updated in this coordinate system only. This leads to a very simple mesh moving algorithm which makes it easy to trace the motion of the moving boundaries and the free su rface without producing undesirable distortion of the computational mesh. The fi nite element method and finite difference method are used spacewise and timewise , respectively. A numerical example involving either forced horizontal oscillati on or forced pitching oscillation of the fluid filled container is presented to illustrate the effectiveness and the robustness of the method. In additi on, this work can be extended for the fluid structure interaction problems. 展开更多
关键词 nonlinear sloshing ar bitrary Lagrangian Eulerian (ALE) description finite element method (fem) n umerical simulation moving boundary
下载PDF
Analysis of Si/GaAs Bonding Stresses with the Finite Element Method
16
作者 何国荣 杨国华 +5 位作者 郑婉华 吴旭明 王小东 曹玉莲 王青 陈良惠 《Journal of Semiconductors》 EI CAS CSCD 北大核心 2006年第11期1906-1910,共5页
In conjunction with ANSYS,we use the finite element method to analyze the bonding stresses of Si/ GaAs. We also apply a numerical model to investigate a contour map and the distribution of normal stress,shearing stres... In conjunction with ANSYS,we use the finite element method to analyze the bonding stresses of Si/ GaAs. We also apply a numerical model to investigate a contour map and the distribution of normal stress,shearing stress, and peeling stress, taking into full consideration the thermal expansion coefficient as a function of temperature. Novel bonding structures are proposed for reducing the effect of thermal stress as compared with conventional structures. Calculations show the validity of this new structure. 展开更多
关键词 BONDING thermal stress finite element analysis
下载PDF
Computer model of the human head-neck and finite element analysis 被引量:3
17
作者 薛强 卢晓艳 《微计算机信息》 北大核心 2008年第6期262-264,共3页
The difficulty in establishing the finite element model of head and cervical spine is interpreted in the study. A head-neck 3D model is constructed accurately and quickly by the technology of CT scan,the automatically... The difficulty in establishing the finite element model of head and cervical spine is interpreted in the study. A head-neck 3D model is constructed accurately and quickly by the technology of CT scan,the automatically modeling of Mimics software and the RE technology of Geomagic software. Then the finite element model of the head-neck which is close to the real one is set up by the preprocessor of the FEM soft ware ANSYS. After the transient finite element analysis is performed on the model,the historical response of the displacement of the head is obtained. The result is validated by the result of the existed experiment. The stress,as well as the deformation,of nodes in the head and the cervical spine at any time benefits a lot to the clinic study on the injure to the head and neck caused by the impacts. And all the analysis is done by limited computer available. 展开更多
关键词 头颈椎 计算机模型 生物力学 有限元分析
下载PDF
Seismic performance of double-skin steel-concrete composite box piers: Part Ⅱ—Nonlinear finite element analysis
18
作者 夏坚 宗周红 +1 位作者 徐焯然 李明鸿 《Journal of Southeast University(English Edition)》 EI CAS 2016年第3期346-355,共10页
An accurate finite element ( FE) model was constructed to examine the hysteretic behavior of double-skin steel-concrete composite box ( DSCB) piers for further understanding the seismic performance of DSCB piers;... An accurate finite element ( FE) model was constructed to examine the hysteretic behavior of double-skin steel-concrete composite box ( DSCB) piers for further understanding the seismic performance of DSCB piers; where the local buckling behavior of steel tubes, the confinement of the in-filled concrete and the interface action between steel tube and in-filled concrete were considered. The accuracy of the proposed FE model was verified by the bidirectional cyclic loading test results. Based on the validated FE model, the effects of some key parameters, such as section width to steel thickness ratio, slenderness ratio, aspect ratio and axial load ratio on the hysteretic behavior of DSCB piers were investigated. Finally, the skeleton curve model of DSCB piers was proposed. The numerical simulation results reveal that the peak strength and elastic stiffness decrease with the increase of the section width to steel thickness ratio. Moreover, the increase of the slenderness ratio may result in a significant reduction in the peak strength and elastic stiffness while the ultimate displacement increases. The proposed skeleton curve model can be taken as a reference for seismic performance analyses of the DSCB piers. 展开更多
关键词 double-skin steel-concrete composite box(DSCB) pier finite element analysis local buckling hysteretic behavior skeleton curve model
下载PDF
STIFFNESS ANALYSIS OF THE MAIN MODULE FOR PARALLEL MACHINE TOOLS BY FINITE ELEMENT ANALYSIS 被引量:2
19
作者 周立华 王玉茹 +1 位作者 黄田 Modler K H 《Transactions of Tianjin University》 EI CAS 2001年第1期30-35,共6页
With the aid of commercial finite element analysis software package ANSYS,investigations are made on the contributions of main components to stiffness of the main module for parallel machine tools,and it is found that... With the aid of commercial finite element analysis software package ANSYS,investigations are made on the contributions of main components to stiffness of the main module for parallel machine tools,and it is found that the frame is the main contributor.Then,influences of constraints,strut length and working ways of the main module have also been investigated.It can be concluded that when one of the main planes of the frame without linear drive unit is constrained,the largest whole stiffness can be acquired.And,the stiffness is much better when the main module is used in a vertical machine tool instead of a horizontal one.Finally,the principle of stiffness variation is summarized when the mobile platform reaches various positions within its working space and when various loads are applied.These achievements have provided critical instructions for the design of the main module for parallel machine tools. 展开更多
关键词 parallel machine tool main module STIFFNESS finite element analysis
全文增补中
面向FEM快速建模的船体模型数据处理算法
20
作者 李瑞 王明发 +2 位作者 孟昭闯 刘国磊 邱永添 《中国舰船研究》 CSCD 北大核心 2024年第5期49-56,共8页
[目的]为提高船体有限元几何建模效率,解决船舶设计软件导出的船体模型无法直接应用于有限元几何建模的问题,提出一种基于XML文件数据的几何模型处理方法。[方法]以AVEVA Marine(AM)软件导出的船体XML文件为研究对象,通过对文件的数据... [目的]为提高船体有限元几何建模效率,解决船舶设计软件导出的船体模型无法直接应用于有限元几何建模的问题,提出一种基于XML文件数据的几何模型处理方法。[方法]以AVEVA Marine(AM)软件导出的船体XML文件为研究对象,通过对文件的数据结构解析,明确几何模型的数据表达规则,依据船体有限元几何建模规范,通过修改模型数据实现对船体模型的几何修正,包括对角隅、开孔等构件的删除、简化处理,对球扁钢和肘板的转化处理,对型材和板缝的移动处理。[结果]实际运用结果表明,处理后的船体几何模型可直接导入有限元软件HyperMesh中,符合有限元实体几何建模规范,保留了原模型材料、板架厚度等相关属性。[结论]与人工建模相比,测试分段实体几何建模效率显著提高,所提方法有助于船体设计模型复用、提高有限元几何建模效率。 展开更多
关键词 快速有限元分析 船体模型 模型数据 数据转换 XML格式 AVEVA Marine软件
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部