According the to the model of single tank fire control system, this paper makes use of decomposition-coordination theory of large-scale systems to discuss the shooting problem of multiple tank the control systems, and...According the to the model of single tank fire control system, this paper makes use of decomposition-coordination theory of large-scale systems to discuss the shooting problem of multiple tank the control systems, and alalyzes specifically the three-tank the control systems and models.the process was imitated in computer, and the optimal shooting element of 3TS system was got. In addition, probability of hitting the target was calculated.展开更多
A method of accuracy assignment based on fuzzy comprehensive judgment method (FCJM) in tank fire control system is proposed. From the flowing route of the error sources and their respective correlative signals, the tr...A method of accuracy assignment based on fuzzy comprehensive judgment method (FCJM) in tank fire control system is proposed. From the flowing route of the error sources and their respective correlative signals, the transfer functions of several sources are analysed by means of mathematic simulation, and FCJM is applied to obtain the cost comprehensive factor for each part of system, combining its error sensitivity factor the mathematical model is built to solve the accuracy assignment problem. Simulation result shows the proposed method can help designer of tank fire control system work out an optimal system more efficiently and more economically.展开更多
A method of accuracy assignment based on value analysis method (VAM) in tank fire control system (TFCS) is proposed. From the analysis of primary error sources and their error transfer relationships, the mathemati...A method of accuracy assignment based on value analysis method (VAM) in tank fire control system (TFCS) is proposed. From the analysis of primary error sources and their error transfer relationships, the mathematical model is built on the basis of VAM to solve the accuracy assignment problem. Simulation results show the validation and feasibility of the proposed method. It can help designer of tank fire control system work out an optimal system more efficiently and more economically.展开更多
Missile fire control system is the core of ship-based missile weapon system, whose safeguard level has direct relation with the attack ability of naval vessels. After a long period of deep investigation and research, ...Missile fire control system is the core of ship-based missile weapon system, whose safeguard level has direct relation with the attack ability of naval vessels. After a long period of deep investigation and research, it was found that, in one missile fire control system, there are such problems as single safeguard system, low ratio of cost to efficiency, etc. By adopting intelligent control techniques and many measures to multiple securities, the new type of assistant system is designed, some difficult problems are solved, such as fixed project channel and unitary means of missiles, which can make the equipment carry out combat mission reliably and continuously.展开更多
A fire control system of artillery includes a photo-tracker, a computing subsystem and a servomechanism. The photo-tracker outputs moving characteristics of the target during the tracking process, and basing upon this...A fire control system of artillery includes a photo-tracker, a computing subsystem and a servomechanism. The photo-tracker outputs moving characteristics of the target during the tracking process, and basing upon this, the computing subsystem makes the computation and outputs shooting elements, and the servo-mechanism controls this piece of artillery to point to the foregoing position of its target in terms of the latter elements.展开更多
This paper introduces a hierarchical real-time environment for developing ship-bornefire-control system. Advanced computer networks are used to simulate the system with the requiredengagement scenario, including own-s...This paper introduces a hierarchical real-time environment for developing ship-bornefire-control system. Advanced computer networks are used to simulate the system with the requiredengagement scenario, including own-ship and parameters, and data processing and transmission,mission calculation, graphical supervision and gunnery ballistics outputting. The simulation systemis able to receive instruction from, or send information to the command-control center. Furthermore,the system can also be used to compare various designed schemes and analyze the accuracy andeffectiveness of the system.展开更多
Erwinia amylovora species were isolated from the blossoms, exudates, infected fruits, leaves and bent branches of diseased apple, pear and hawthorn trees, selected in the Chy, Osh and Jalal Abad regions. Biochemical a...Erwinia amylovora species were isolated from the blossoms, exudates, infected fruits, leaves and bent branches of diseased apple, pear and hawthorn trees, selected in the Chy, Osh and Jalal Abad regions. Biochemical and pathogenicity tests, alongside PCR analyses, were conducted to identify the local isolates of Erwinia amylovora. The alternative antagonistic microorganisms which combat bacterium E. amylovora were tested within in vitro and in vivo conditions. The results revealed the ability of Streptomyces antagonistic bacteria to decrease fire blight severity on pear and apple trees during the first stage of the fire blight disease in leaf tissues. Streptomyces strain C1-4 suppressed E. amylovora disease symptoms in the leaf tissues and excised apple and pear shoots. The incidence of fire blight on leaves was reduced by about 70% with two applications of bacterial antagonists. Further studies at different locations in Kyrgyzstan, using large scale application, would allow for stronger recommendations to be made, including studies and recommendations on their ability to prevent disease and to use them as main components in an integrated pest management program.展开更多
The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-...The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics(CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.展开更多
The fire causes water pollution, air pollution and toxic gas pollution to our surrounding environment, and it seriously affects our living environment. People's awareness of environmental protection is increasing ...The fire causes water pollution, air pollution and toxic gas pollution to our surrounding environment, and it seriously affects our living environment. People's awareness of environmental protection is increasing year by year, and environmental pollution caused by the fire is also being controlled. This article briefly introduces the fire accident's impact on the environment, the systematic analysis of the fire accident in the source of pollution and its harm. Combined with the existing way of fire fighting and rescue fire accident, the pollution control method is proposed.展开更多
A modified method of design of no-steady-error and anti-disturbance controller is proposed for the design of tank stabilizers. Using a reduced-order observer to estimate its mode, disturbance can be compensated. This ...A modified method of design of no-steady-error and anti-disturbance controller is proposed for the design of tank stabilizers. Using a reduced-order observer to estimate its mode, disturbance can be compensated. This enables the system to resist sinusoidal disturbance with any magnitude. Estimate of angular velocity is used as the state feedback to replace the expensive gyro and tachometer generator. The modified method excels the traditional, and provides a new way for the design of tank fire control system. It can also be applied for the design of other servo systems in vehicle and aircraft.展开更多
To counter BTT guidance mode, new relative motion equations of the targetaircraft and the attack aircraft are proposed. The inverse system theory of the nonlinearcontrol is used, and the direct BTT-180 guidance comman...To counter BTT guidance mode, new relative motion equations of the targetaircraft and the attack aircraft are proposed. The inverse system theory of the nonlinearcontrol is used, and the direct BTT-180 guidance command is solved, which can operatethe attack aircraft to automatically complete the flight mission of the preceding stage ofthe terminal weapon delivery, and thus the automatic attack is extended from the stage ofthe terminal weapon delivery to the preceding stage of the terminal weapon delivery.展开更多
2-tridecanone is a major constitute of defensive secretion in tawny crazy ants, Nylanderia fulva that is an ant species reported to be able to displace red imported fire ants, Solenopsis invicta in the field. 2-tridec...2-tridecanone is a major constitute of defensive secretion in tawny crazy ants, Nylanderia fulva that is an ant species reported to be able to displace red imported fire ants, Solenopsis invicta in the field. 2-tridecanone was proven to be toxic to S. invicta. Although 2-tridecanone is commercially available, utilization of this naturally occurring compound in fire ant management has received little attention. In this study, toxicity and efficacy of two 2-tridecanone formulations were assessed against S. invicta. Two emulsifiable concentrates were prepared using 2-tridecanone as an active ingredient, vegetable oil as a solvent and polyoxyethylene tridecyl ether as a surfactant. Piperonyl butoxide (PBO) was used as a synergist in one formulation. Both formulations showed significant toxicity in laboratory bioassays. In a field trial, at application rate of 5.28 mL/L and 14 days after mound drench treatment, 100% control was achieved for formulation with PBO and 90% control for the formulation without PBO. In conclusion, both formulations had significant efficacy against S. invicta. Due to the low mammalian toxicity of 2-tridecanone, no involvement of hazardous synthetic organic solvents, no phytotoxicity at applied concentrations, and relatively low cost, both formulations are promising alternatives to commercial insecticide products for fire ant mound drench. The outstanding efficacy of both formulations observed in this study warrants further research on their efficacy against other pest insects.展开更多
In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale p...In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.展开更多
Fire blight, caused by Erwinia amylovora, is a devastating disease of apples and pears, causing enormous economic losses around the world. The disease is indigenous to North America and has spread to more than 50 coun...Fire blight, caused by Erwinia amylovora, is a devastating disease of apples and pears, causing enormous economic losses around the world. The disease is indigenous to North America and has spread to more than 50 countries since its discovery in 1870 s. Recent reports of the disease in China's neighboring countries, including South Korea, Kyrgyzstan, and Kazakhstan, pose great threat to the world's leading producer of apples and pears. This mini-review intends to provide an update on the disease, pathogen biology, epidemiology, and control. It will also provide some perspectives and suggestions for the apple and pear industry and growers in China, which will face the imminent threat of this devastating disease.展开更多
In this paper, intrinsic safety and positive security distance control for an up/down elevator which extracts the materials from an underground coal mine is approached. For a better understanding of intrinsic safety a...In this paper, intrinsic safety and positive security distance control for an up/down elevator which extracts the materials from an underground coal mine is approached. For a better understanding of intrinsic safety and positive security, the first part of the paper describes the potential risk the workers are facing while working in dangerous environments like coal mining with “grisou” atmospheres and what the conditions of an unfortunate event to take place are. We presented the diagram and working principle for intrinsic safety equipment used in potential explosive areas based on which we modeled and simulated the intrinsic and positive security distance control in order to get a software solution for it. We created an algorithm and simulated the process in Matlab Simulink. The simulation results done in Matlab Simulink were then entered into a Moeller PLC using a ladder-type programming language. For protection against explosive atmospheres, the PLC is inserted into a metal housing with intrinsic protection and Positive Security.展开更多
According to the data of historical climate passed 100 years, the comprehensive effect of various factors, including seawater temperature,sunspots activities, volcanic explosion, co2 concentration,o3 con centration an...According to the data of historical climate passed 100 years, the comprehensive effect of various factors, including seawater temperature,sunspots activities, volcanic explosion, co2 concentration,o3 con centration and atmospheric circulation index,climate change of Heilong jiang province,was analyzed.The tendency of climate change of Heilong jiang province in the next ten years was predicted. The influence of climate change on forest fire was put forward and response strategy was briefly discussed.展开更多
Mathematical model of forest fire was based on an analysis of known experimental data and using concept and methods from reactive media mechanics. In this paper the assignment and theoretical investigations of the pro...Mathematical model of forest fire was based on an analysis of known experimental data and using concept and methods from reactive media mechanics. In this paper the assignment and theoretical investigations of the problems of crown forest fire spread in windy condition were carried out. In this context, a study—mathematical modeling—of the conditions of forest fire spreading that would make it possible to obtain a detailed picture of the change in the temperature and component concentration fields with time, and determine as well as the limiting condition of fire propagation in forest with fire break.展开更多
文摘According the to the model of single tank fire control system, this paper makes use of decomposition-coordination theory of large-scale systems to discuss the shooting problem of multiple tank the control systems, and alalyzes specifically the three-tank the control systems and models.the process was imitated in computer, and the optimal shooting element of 3TS system was got. In addition, probability of hitting the target was calculated.
文摘A method of accuracy assignment based on fuzzy comprehensive judgment method (FCJM) in tank fire control system is proposed. From the flowing route of the error sources and their respective correlative signals, the transfer functions of several sources are analysed by means of mathematic simulation, and FCJM is applied to obtain the cost comprehensive factor for each part of system, combining its error sensitivity factor the mathematical model is built to solve the accuracy assignment problem. Simulation result shows the proposed method can help designer of tank fire control system work out an optimal system more efficiently and more economically.
文摘A method of accuracy assignment based on value analysis method (VAM) in tank fire control system (TFCS) is proposed. From the analysis of primary error sources and their error transfer relationships, the mathematical model is built on the basis of VAM to solve the accuracy assignment problem. Simulation results show the validation and feasibility of the proposed method. It can help designer of tank fire control system work out an optimal system more efficiently and more economically.
基金Sponsored by Major Task Financially-aided for Military Equipment Maintenance Safeguard
文摘Missile fire control system is the core of ship-based missile weapon system, whose safeguard level has direct relation with the attack ability of naval vessels. After a long period of deep investigation and research, it was found that, in one missile fire control system, there are such problems as single safeguard system, low ratio of cost to efficiency, etc. By adopting intelligent control techniques and many measures to multiple securities, the new type of assistant system is designed, some difficult problems are solved, such as fixed project channel and unitary means of missiles, which can make the equipment carry out combat mission reliably and continuously.
文摘A fire control system of artillery includes a photo-tracker, a computing subsystem and a servomechanism. The photo-tracker outputs moving characteristics of the target during the tracking process, and basing upon this, the computing subsystem makes the computation and outputs shooting elements, and the servo-mechanism controls this piece of artillery to point to the foregoing position of its target in terms of the latter elements.
文摘This paper introduces a hierarchical real-time environment for developing ship-bornefire-control system. Advanced computer networks are used to simulate the system with the requiredengagement scenario, including own-ship and parameters, and data processing and transmission,mission calculation, graphical supervision and gunnery ballistics outputting. The simulation systemis able to receive instruction from, or send information to the command-control center. Furthermore,the system can also be used to compare various designed schemes and analyze the accuracy andeffectiveness of the system.
文摘Erwinia amylovora species were isolated from the blossoms, exudates, infected fruits, leaves and bent branches of diseased apple, pear and hawthorn trees, selected in the Chy, Osh and Jalal Abad regions. Biochemical and pathogenicity tests, alongside PCR analyses, were conducted to identify the local isolates of Erwinia amylovora. The alternative antagonistic microorganisms which combat bacterium E. amylovora were tested within in vitro and in vivo conditions. The results revealed the ability of Streptomyces antagonistic bacteria to decrease fire blight severity on pear and apple trees during the first stage of the fire blight disease in leaf tissues. Streptomyces strain C1-4 suppressed E. amylovora disease symptoms in the leaf tissues and excised apple and pear shoots. The incidence of fire blight on leaves was reduced by about 70% with two applications of bacterial antagonists. Further studies at different locations in Kyrgyzstan, using large scale application, would allow for stronger recommendations to be made, including studies and recommendations on their ability to prevent disease and to use them as main components in an integrated pest management program.
文摘The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics(CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.
文摘The fire causes water pollution, air pollution and toxic gas pollution to our surrounding environment, and it seriously affects our living environment. People's awareness of environmental protection is increasing year by year, and environmental pollution caused by the fire is also being controlled. This article briefly introduces the fire accident's impact on the environment, the systematic analysis of the fire accident in the source of pollution and its harm. Combined with the existing way of fire fighting and rescue fire accident, the pollution control method is proposed.
文摘A modified method of design of no-steady-error and anti-disturbance controller is proposed for the design of tank stabilizers. Using a reduced-order observer to estimate its mode, disturbance can be compensated. This enables the system to resist sinusoidal disturbance with any magnitude. Estimate of angular velocity is used as the state feedback to replace the expensive gyro and tachometer generator. The modified method excels the traditional, and provides a new way for the design of tank fire control system. It can also be applied for the design of other servo systems in vehicle and aircraft.
文摘To counter BTT guidance mode, new relative motion equations of the targetaircraft and the attack aircraft are proposed. The inverse system theory of the nonlinearcontrol is used, and the direct BTT-180 guidance command is solved, which can operatethe attack aircraft to automatically complete the flight mission of the preceding stage ofthe terminal weapon delivery, and thus the automatic attack is extended from the stage ofthe terminal weapon delivery to the preceding stage of the terminal weapon delivery.
文摘2-tridecanone is a major constitute of defensive secretion in tawny crazy ants, Nylanderia fulva that is an ant species reported to be able to displace red imported fire ants, Solenopsis invicta in the field. 2-tridecanone was proven to be toxic to S. invicta. Although 2-tridecanone is commercially available, utilization of this naturally occurring compound in fire ant management has received little attention. In this study, toxicity and efficacy of two 2-tridecanone formulations were assessed against S. invicta. Two emulsifiable concentrates were prepared using 2-tridecanone as an active ingredient, vegetable oil as a solvent and polyoxyethylene tridecyl ether as a surfactant. Piperonyl butoxide (PBO) was used as a synergist in one formulation. Both formulations showed significant toxicity in laboratory bioassays. In a field trial, at application rate of 5.28 mL/L and 14 days after mound drench treatment, 100% control was achieved for formulation with PBO and 90% control for the formulation without PBO. In conclusion, both formulations had significant efficacy against S. invicta. Due to the low mammalian toxicity of 2-tridecanone, no involvement of hazardous synthetic organic solvents, no phytotoxicity at applied concentrations, and relatively low cost, both formulations are promising alternatives to commercial insecticide products for fire ant mound drench. The outstanding efficacy of both formulations observed in this study warrants further research on their efficacy against other pest insects.
基金Sponsored by the National Natural Science Foundation of China(Grant No.50678050)
文摘In order to validate the accuracy of nonlinear fire simulation programs,comparison analysis is carried out between simulation and experiment induced from small-scale specimens,and then fire resistance of large-scale prestressed concrete slabs is further investigated through parameter expansion.The influences on fire resistance ratings controlled by deflection are explored and discussed,including effective span,concrete cover thickness,load level,prestress degree,effective prestress,composite reinforcement index and other factors.The calculated results indicate that fire resistance ratings of large-scale bonded prestressed concrete simply supported slabs are bigger than those of small-scale ones.Finally,the calculation formulas of fire resistance ratings controlled by deflection are established,which rationally consider the influence of effective span,concrete cover thickness,load level,composite reinforcement index and so on key factors.
基金supported by the National Key R&D Program of China(2016YFC1201200)the National Natural Science Foundation of China(31500107 and 31772231)
文摘Fire blight, caused by Erwinia amylovora, is a devastating disease of apples and pears, causing enormous economic losses around the world. The disease is indigenous to North America and has spread to more than 50 countries since its discovery in 1870 s. Recent reports of the disease in China's neighboring countries, including South Korea, Kyrgyzstan, and Kazakhstan, pose great threat to the world's leading producer of apples and pears. This mini-review intends to provide an update on the disease, pathogen biology, epidemiology, and control. It will also provide some perspectives and suggestions for the apple and pear industry and growers in China, which will face the imminent threat of this devastating disease.
文摘In this paper, intrinsic safety and positive security distance control for an up/down elevator which extracts the materials from an underground coal mine is approached. For a better understanding of intrinsic safety and positive security, the first part of the paper describes the potential risk the workers are facing while working in dangerous environments like coal mining with “grisou” atmospheres and what the conditions of an unfortunate event to take place are. We presented the diagram and working principle for intrinsic safety equipment used in potential explosive areas based on which we modeled and simulated the intrinsic and positive security distance control in order to get a software solution for it. We created an algorithm and simulated the process in Matlab Simulink. The simulation results done in Matlab Simulink were then entered into a Moeller PLC using a ladder-type programming language. For protection against explosive atmospheres, the PLC is inserted into a metal housing with intrinsic protection and Positive Security.
文摘According to the data of historical climate passed 100 years, the comprehensive effect of various factors, including seawater temperature,sunspots activities, volcanic explosion, co2 concentration,o3 con centration and atmospheric circulation index,climate change of Heilong jiang province,was analyzed.The tendency of climate change of Heilong jiang province in the next ten years was predicted. The influence of climate change on forest fire was put forward and response strategy was briefly discussed.
文摘Mathematical model of forest fire was based on an analysis of known experimental data and using concept and methods from reactive media mechanics. In this paper the assignment and theoretical investigations of the problems of crown forest fire spread in windy condition were carried out. In this context, a study—mathematical modeling—of the conditions of forest fire spreading that would make it possible to obtain a detailed picture of the change in the temperature and component concentration fields with time, and determine as well as the limiting condition of fire propagation in forest with fire break.