This paper introduces a new-developed mine fire-resistant optical fiber cable (OFC)KL5004,its structural characteristics, main feature, the theory about fire resistance and its application in high output and efficienc...This paper introduces a new-developed mine fire-resistant optical fiber cable (OFC)KL5004,its structural characteristics, main feature, the theory about fire resistance and its application in high output and efficiency mine.展开更多
The development of the sensor suitable for measuring large load stress to the anchor cable becomes an important task in bridge construction and maintenance. Therefore, a new type of optical fiber sensor was developed ...The development of the sensor suitable for measuring large load stress to the anchor cable becomes an important task in bridge construction and maintenance. Therefore, a new type of optical fiber sensor was developed in the laboratory - optical fiber grating sensor for force measurement of anchor cable (OFBFMAC). No similar report about this kind of sensor has been found up to now in China and other countries. This sensor is proved to be an effective way of monitoring in processes of anchor cable installation, cable cutting, cable force regulation, etc, with the accurate and repeatable measuring results. Its successful application in the tie bar cable force safety monitoring for Wuhan Qingchuan bridge is a new exploration of optical fiber grating sensing technology in bridge tie bar monitoring system.展开更多
Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected...Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected by lightning, sometimes lightning damaging optical cable and flashover discharge accidents of optical cable port occurred. In this paper, the amplitude spectrum of lightning wave, the breakdown depth and breakdown distance of lightning wave to soil, the metal components of optical cable port and the impedance characteristics of grounding wire are systematically analyzed, and the prevention methods of directly buried optical cable in wind farm to avoid lightning damage are proposed.展开更多
1. Southern Coastal Optical Cable Engineering Project. The cable was completed and put into operation in 1992, and has a total length of 2,800km, starting from Nanjing in the north, via Shanghai, Hangzhou, Fuzhou, Xia...1. Southern Coastal Optical Cable Engineering Project. The cable was completed and put into operation in 1992, and has a total length of 2,800km, starting from Nanjing in the north, via Shanghai, Hangzhou, Fuzhou, Xiamen, Huizhou, leading to Guangzhou in the south, covering Jiangsu, Shanghai, Zhejiang, Fujian and Guangdong. The whole line has展开更多
A key project of the state, the Beijing-Taiyuan-Xi’an optical cable communications trunk, is one of the 22 optical cables planned to be laid by the Ministry of Post and Telecommunications during the Eighth Five Year....A key project of the state, the Beijing-Taiyuan-Xi’an optical cable communications trunk, is one of the 22 optical cables planned to be laid by the Ministry of Post and Telecommunications during the Eighth Five Year. Plan. This communication cable trunk covers a distance of 1771 km, starting from Beijing and going via Hebei and Shanxi to Xi’an in Shaanxi, linking two provincial capitals, one municipality directly under the jurisdiction of the central government, seven other cities and 32 counties.展开更多
Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables hav...Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content.In this paper,the performances of two heated cables,i.e.the carbon-fiber heated cable(CFHC)and the metalnet heated cable(MNHC),are studied in the laboratory.Their structures,uniformity in the axial direction,measurement accuracy and suitability are evaluated.The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC.Both CFHC and MNHC have high measurement accuracy.The CFHC is more suitable for short-distance measurement(500 m),while the MNHC can be used for longdistance measurement(>500 m).展开更多
文摘This paper introduces a new-developed mine fire-resistant optical fiber cable (OFC)KL5004,its structural characteristics, main feature, the theory about fire resistance and its application in high output and efficiency mine.
基金Supported by the National Natural Science Foundation ofChina (60537050)
文摘The development of the sensor suitable for measuring large load stress to the anchor cable becomes an important task in bridge construction and maintenance. Therefore, a new type of optical fiber sensor was developed in the laboratory - optical fiber grating sensor for force measurement of anchor cable (OFBFMAC). No similar report about this kind of sensor has been found up to now in China and other countries. This sensor is proved to be an effective way of monitoring in processes of anchor cable installation, cable cutting, cable force regulation, etc, with the accurate and repeatable measuring results. Its successful application in the tie bar cable force safety monitoring for Wuhan Qingchuan bridge is a new exploration of optical fiber grating sensing technology in bridge tie bar monitoring system.
基金Supported by Regional Lightning Protection Engineering Technology Research and Development Project in Guangdong Yuedian Dianbai Wind Farm (GDW-PK-21022 Phase II)。
文摘Directly buried metal optical cable is a form of erecting optical fiber ring network communication system in wind farms. Although the directly buried optical cable is much less than the overhead optical cable affected by lightning, sometimes lightning damaging optical cable and flashover discharge accidents of optical cable port occurred. In this paper, the amplitude spectrum of lightning wave, the breakdown depth and breakdown distance of lightning wave to soil, the metal components of optical cable port and the impedance characteristics of grounding wire are systematically analyzed, and the prevention methods of directly buried optical cable in wind farm to avoid lightning damage are proposed.
文摘1. Southern Coastal Optical Cable Engineering Project. The cable was completed and put into operation in 1992, and has a total length of 2,800km, starting from Nanjing in the north, via Shanghai, Hangzhou, Fuzhou, Xiamen, Huizhou, leading to Guangzhou in the south, covering Jiangsu, Shanghai, Zhejiang, Fujian and Guangdong. The whole line has
文摘A key project of the state, the Beijing-Taiyuan-Xi’an optical cable communications trunk, is one of the 22 optical cables planned to be laid by the Ministry of Post and Telecommunications during the Eighth Five Year. Plan. This communication cable trunk covers a distance of 1771 km, starting from Beijing and going via Hebei and Shanxi to Xi’an in Shaanxi, linking two provincial capitals, one municipality directly under the jurisdiction of the central government, seven other cities and 32 counties.
基金The financial supports provided by the National Natural Science Foundation of China(Grant Nos.41230636,41372265,41427801)National Basic Research Program of China(973 Project)(Grant No.2011CB710605)
文摘Distributed temperature sensing(DTS)using heated cables has been recently developed for distributed monitoring of in-situ soil moisture content.In this method,the thermal and electrical properties of heated cables have a significant influence on the measurement accuracy of soil moisture content.In this paper,the performances of two heated cables,i.e.the carbon-fiber heated cable(CFHC)and the metalnet heated cable(MNHC),are studied in the laboratory.Their structures,uniformity in the axial direction,measurement accuracy and suitability are evaluated.The test results indicate that the MNHC has a better uniformity in the axial direction than CFHC.Both CFHC and MNHC have high measurement accuracy.The CFHC is more suitable for short-distance measurement(500 m),while the MNHC can be used for longdistance measurement(>500 m).