Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is ap...Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.展开更多
In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) k-ε ...In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) k-ε model and a new method for cell face velocity interpolation based on a non-staggered grid system are employed. To avoid pseudo-diffusion that is significant in modeling tangentially fired furnaces, attempts are made at improving the differential volume scheme. Some new developments on turbulent diffusion of particles are also taken into account. Thus, computational accuracy is improved substantially.展开更多
Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportio...Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.展开更多
The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along ...The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.展开更多
This work presents a computational investigation of hydrodynamics,coal combustion and NOx emissions in a tangentially fired pulverized coal boiler at different loads(630,440 and 300 MW;relative loads of 100%,70%and 48...This work presents a computational investigation of hydrodynamics,coal combustion and NOx emissions in a tangentially fired pulverized coal boiler at different loads(630,440 and 300 MW;relative loads of 100%,70%and 48%)to clarify the effect of load change on the furnace processes.A computational fluids dynamics model was established;the flow field,temperature profile,species concentration and NOx emissions were predicted numerically;and the influence of burner tilt angles was evaluated.Simulation results indicate that a decrease in boiler load decreases the gas velocity,attenuates the airflow rotations,and increases the tangent circle size.The high-temperature zone and flame moved toward the side walls.Such behaviors impair air-fuel mixing,heat transfer and steady combustion in the furnace.In terms of species concentrations,a decrease in boiler load increased the O2 content,decreased the CO content,and decreased the char burnout rates only slightly.A change in boiler load from 630 to 440 and 300 MW increased the NOx emissions from 202 to 234 and 247 mg/m^(3),respectively.Burner tilt angles are important in coal combustion and NOx emissions.A burner angle of-15°favors heat transfer and low NOx emissions(<185 mg/m^(3))for the current tangentially fired boiler.展开更多
文摘Based on the porosity method and the improved non uniform QUICK scheme, this paper describes a three dimensional computer simulation to predict the flow characteristics in a tangentially fired boiler. The model is applied to a 600?MW boiler modeling under different operating conditions of reverse swirl of secondary air. The numerical results achieve reasonable agreement with experimental data. The calculated results of flow field, the pressure distribution, the relative diameter of tangential circle, angular momentum flux in furnace and the velocity distribution index in horizontal gas pass are analyzed in detail. And then the effects of the reverse swirl of secondary air on flue gas imbalance are discussed. Finally a reasonable operating condition of the reverse swirl of secondary air is presented.
基金Supported by the National Science Foundation of Zhejiang Province
文摘In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) k-ε model and a new method for cell face velocity interpolation based on a non-staggered grid system are employed. To avoid pseudo-diffusion that is significant in modeling tangentially fired furnaces, attempts are made at improving the differential volume scheme. Some new developments on turbulent diffusion of particles are also taken into account. Thus, computational accuracy is improved substantially.
基金Supported by the National Natural Science Foundation of China (61174059, 60934007, 61233004)the National Basic Research Program of China (2013CB035406)Shanghai Rising-Star Tracking Program (11QH1401300)
文摘Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.
基金Supported by the National Science Foundation of Zhejiang Province.
文摘The paper describes numerical and experimental study on reduction of NOx emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOX formation mechanism model, along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.
基金The authors acknowledge the support from the National Nature Science Foundation of China(No.51476058)and SINOPEC project(No.318015-6).
文摘This work presents a computational investigation of hydrodynamics,coal combustion and NOx emissions in a tangentially fired pulverized coal boiler at different loads(630,440 and 300 MW;relative loads of 100%,70%and 48%)to clarify the effect of load change on the furnace processes.A computational fluids dynamics model was established;the flow field,temperature profile,species concentration and NOx emissions were predicted numerically;and the influence of burner tilt angles was evaluated.Simulation results indicate that a decrease in boiler load decreases the gas velocity,attenuates the airflow rotations,and increases the tangent circle size.The high-temperature zone and flame moved toward the side walls.Such behaviors impair air-fuel mixing,heat transfer and steady combustion in the furnace.In terms of species concentrations,a decrease in boiler load increased the O2 content,decreased the CO content,and decreased the char burnout rates only slightly.A change in boiler load from 630 to 440 and 300 MW increased the NOx emissions from 202 to 234 and 247 mg/m^(3),respectively.Burner tilt angles are important in coal combustion and NOx emissions.A burner angle of-15°favors heat transfer and low NOx emissions(<185 mg/m^(3))for the current tangentially fired boiler.