A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-orde...A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-order derivative spectrum were obtained from the original spectrum. The values of derivative selected at 995 nm were used for determination. It was proved that Vc could quickly react with Folin-Ciocalteau reagent within 5 min and the product was quite stable for a long time. The conditions required for this method is not very complicated, its precision and accuracy are similar to those of the iodometric titration described in Chinese Pharmacopoeia, and the limit of detection is 0.312 μg/mL. The determination of the results of vitamin C tablet, pill, and injection demonstrates that this method has wide pharmaceutical applications.展开更多
A rapid, reliable and accurate method for the determination of hexavalent chromium in Portland cement is developed. The proposed method includes direct spectrophotometric determination of Cr (VI) in Portland cement wi...A rapid, reliable and accurate method for the determination of hexavalent chromium in Portland cement is developed. The proposed method includes direct spectrophotometric determination of Cr (VI) in Portland cement with 1, 2, 5, 8 Tetrahydroxyanthraquinone, (Quinalizarin, QINZ) at pH 1.5. The European Directive (2003/53/EC) limits the use of cements so that it contains no more than 2 mg.Kg-1 of water-soluble Cr (VI). The absorbance at 565 nm due to Cr (VI)-QINZ complex is recommended for the determination of water-soluble Cr (VI) in Portland cement. The quantification of Cr (VI) released from cement when mixed with water is performed according to TRGS 613 (Technical Rules of Hazardous Substances). The validity of the method is thoroughly examined and the proposed method gives satisfactory results. A derivative spectrophotometric method has been developed for the determination of total Cr (VI) in Portland cement in the presence of Fe (III) and Ti (IV). The hexavalent chromium complex formed at pH 1.5 allows precise and accurate determination of chromium (VI) over the concentration range 0.05 to 3.0 mg.L-1of chromium (VI). The validity of the method was examined by analyzing several Standard Reference Material (SRM) Portland cement samples. The MDL (at 95% confidence level) was found to be 25 ng/mL for chromium (VI) in National Institute of Standards and Technology (NIST) cement samples using the proposed method.展开更多
Two simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for the determination of galanthamine hydrobromide (GH) in bulk and pharmaceutical formulation. First method ...Two simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for the determination of galanthamine hydrobromide (GH) in bulk and pharmaceutical formulation. First method is zero order UV spectrophotometry and second is 1st derivative zero crossing spectrophotometry. The developed methods have shown best results in terms of linearity, accuracy, precision, LOD and LOQ for bulk drugs and marketed formulations. Absorbance was measured at 287 nm for zero order and 277.4 nm for first derivative. It obeyed Lambert-Beer’s law in the range of 30-80 μg mL-1. Both methods have good linearity (r2 = 0.9997) and accuracy found to be 100.5% and 101.2% for both methods respectively.展开更多
A novel simple, sensitive, rapid, direct, and spectrophotometry-based procedure was investigated to determine Th(IV) at trace amounts. The new method is based on Th(IV) chelation with 3,6-dichloro-2,5-dihydroxy-l,4-be...A novel simple, sensitive, rapid, direct, and spectrophotometry-based procedure was investigated to determine Th(IV) at trace amounts. The new method is based on Th(IV) chelation with 3,6-dichloro-2,5-dihydroxy-l,4-benzoquinone(DDBQ). The reagent reacts with Th(IV) in 0.1 M HCl to form an orange 1:2 complex. The stability constant value is 6.62×10~4 for the Th(IV)complex. The Th(IV)-DDBQ obtained shows one peak with a maximum at about 346 nm. The chelate forms immediately and the absorbance remains stable for over24 h. Beer's law was obeyed in the concentration range0–10 μg mL^(-1). The molar absorptivity and Sandell's sensitivity were 4.4×10~4 L mol^(-1)cm^(-1) and 0.0053 μg cm^(-2), respectively. Different analytical parameters were tested in detail. Interfering ion(cations and anions) effects were tested. Methods for Th(IV) determination by second and third-derivative spectrophotometry were also introduced at about 344 and 341 nm, respectively. These two derivative orders offer the feature of sensitivity without the necessity for solvent extraction,heating, or pre-concentration steps. Finally, the methods were successfully utilized for Th(IV) determination in monazite, environmental water, and wastewater samples.展开更多
The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 8-hydroxyquinoline-5-sulphonic acid in the presence of diethylamine and ethanol have been measured by normal and third-de...The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 8-hydroxyquinoline-5-sulphonic acid in the presence of diethylamine and ethanol have been measured by normal and third-derivative spectrophotometry. Their molar absorptivities are 70.7 l.mol^(-1).cm^(-1) for Nd and 62.5 l.mol^(-1).cm^(-1) for Er. They are 7.6 times and 14.9 times greater than those of corresponding chlorides, respectively. Use of the third-derivative spectra both eliminates the interference of Ce(Ⅳ) and increases the sensitivity for Nd and Er. Beer,s Law was obeyed from 0-10 ug/ml of Nd and Er. The method has been applied to the determination of neodymium and erbium in rare earth mixtures.展开更多
基金Natural Science Foundation of Jilin Province, China(No.200305502)
文摘A novel method for the determination of vitamin C(Vc) is proposed in this article. After the reaction with Folin-Ciocalteau reagent at ambient temperature, Vc solution was scanned at 750--1100 nm, and its first-order derivative spectrum were obtained from the original spectrum. The values of derivative selected at 995 nm were used for determination. It was proved that Vc could quickly react with Folin-Ciocalteau reagent within 5 min and the product was quite stable for a long time. The conditions required for this method is not very complicated, its precision and accuracy are similar to those of the iodometric titration described in Chinese Pharmacopoeia, and the limit of detection is 0.312 μg/mL. The determination of the results of vitamin C tablet, pill, and injection demonstrates that this method has wide pharmaceutical applications.
文摘A rapid, reliable and accurate method for the determination of hexavalent chromium in Portland cement is developed. The proposed method includes direct spectrophotometric determination of Cr (VI) in Portland cement with 1, 2, 5, 8 Tetrahydroxyanthraquinone, (Quinalizarin, QINZ) at pH 1.5. The European Directive (2003/53/EC) limits the use of cements so that it contains no more than 2 mg.Kg-1 of water-soluble Cr (VI). The absorbance at 565 nm due to Cr (VI)-QINZ complex is recommended for the determination of water-soluble Cr (VI) in Portland cement. The quantification of Cr (VI) released from cement when mixed with water is performed according to TRGS 613 (Technical Rules of Hazardous Substances). The validity of the method is thoroughly examined and the proposed method gives satisfactory results. A derivative spectrophotometric method has been developed for the determination of total Cr (VI) in Portland cement in the presence of Fe (III) and Ti (IV). The hexavalent chromium complex formed at pH 1.5 allows precise and accurate determination of chromium (VI) over the concentration range 0.05 to 3.0 mg.L-1of chromium (VI). The validity of the method was examined by analyzing several Standard Reference Material (SRM) Portland cement samples. The MDL (at 95% confidence level) was found to be 25 ng/mL for chromium (VI) in National Institute of Standards and Technology (NIST) cement samples using the proposed method.
文摘Two simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for the determination of galanthamine hydrobromide (GH) in bulk and pharmaceutical formulation. First method is zero order UV spectrophotometry and second is 1st derivative zero crossing spectrophotometry. The developed methods have shown best results in terms of linearity, accuracy, precision, LOD and LOQ for bulk drugs and marketed formulations. Absorbance was measured at 287 nm for zero order and 277.4 nm for first derivative. It obeyed Lambert-Beer’s law in the range of 30-80 μg mL-1. Both methods have good linearity (r2 = 0.9997) and accuracy found to be 100.5% and 101.2% for both methods respectively.
文摘A novel simple, sensitive, rapid, direct, and spectrophotometry-based procedure was investigated to determine Th(IV) at trace amounts. The new method is based on Th(IV) chelation with 3,6-dichloro-2,5-dihydroxy-l,4-benzoquinone(DDBQ). The reagent reacts with Th(IV) in 0.1 M HCl to form an orange 1:2 complex. The stability constant value is 6.62×10~4 for the Th(IV)complex. The Th(IV)-DDBQ obtained shows one peak with a maximum at about 346 nm. The chelate forms immediately and the absorbance remains stable for over24 h. Beer's law was obeyed in the concentration range0–10 μg mL^(-1). The molar absorptivity and Sandell's sensitivity were 4.4×10~4 L mol^(-1)cm^(-1) and 0.0053 μg cm^(-2), respectively. Different analytical parameters were tested in detail. Interfering ion(cations and anions) effects were tested. Methods for Th(IV) determination by second and third-derivative spectrophotometry were also introduced at about 344 and 341 nm, respectively. These two derivative orders offer the feature of sensitivity without the necessity for solvent extraction,heating, or pre-concentration steps. Finally, the methods were successfully utilized for Th(IV) determination in monazite, environmental water, and wastewater samples.
文摘The absorption spectra of 4f electron transitions of the complexes of neodymium and erbium with 8-hydroxyquinoline-5-sulphonic acid in the presence of diethylamine and ethanol have been measured by normal and third-derivative spectrophotometry. Their molar absorptivities are 70.7 l.mol^(-1).cm^(-1) for Nd and 62.5 l.mol^(-1).cm^(-1) for Er. They are 7.6 times and 14.9 times greater than those of corresponding chlorides, respectively. Use of the third-derivative spectra both eliminates the interference of Ce(Ⅳ) and increases the sensitivity for Nd and Er. Beer,s Law was obeyed from 0-10 ug/ml of Nd and Er. The method has been applied to the determination of neodymium and erbium in rare earth mixtures.