The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor(GECAM)mission is designed to monitor the Gamma-Ray Bursts(GRBs)associated with gravitational waves and other high-energy transient sources...The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor(GECAM)mission is designed to monitor the Gamma-Ray Bursts(GRBs)associated with gravitational waves and other high-energy transient sources.The mission consists of two microsatellites which are planned to operate at the opposite sides of the Earth.Each GECAM satellite could detect and localize GRBs in about 8 keV-5 MeV with its 25 Gamma-Ray Detectors(GRDs).In this work,we report the in-flight energy calibration of GRDs using the characteristic gamma-ray lines in the background spectra,and show their performance evolution during the commissioning phase.Besides,a preliminary cross-calibration of energy response with Fermi GBM data is also presented,validating the energy response of GRDs.展开更多
POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polar...POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area.展开更多
Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors ...Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.展开更多
Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such...Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of <sup>241</sup>Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time.展开更多
The Gamma-ray Transient Monitor(GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A(DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 ke V to 1 MeV. The GTM...The Gamma-ray Transient Monitor(GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A(DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 ke V to 1 MeV. The GTM was equipped with five Gamma-ray Transient Probe(GTP) detector modules utilizing a NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP uses a dedicated dual-channel coincident readout design. In this work, we first studied the impact of different coincidence times on the detection efficiency and ultimately selected a 0.5 μs time coincidence window for offline data processing. To test the performance of the GTPs and validate the Monte-Carlo-simulated energy response, we conducted comprehensive ground calibration tests using the Hard X-ray Calibration Facility(HXCF) and radioactive sources, including the energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively present the ground calibration results and validate the design and mass model of the GTP detector, thus providing the foundation for in-flight observations and scientific data analysis.展开更多
Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS de...Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS detector,the large-scale modular BGO detection array(LAMBDA),tailored for measuringβ-decay intensity distributions of fission products.The modular design allows the LAMBDA detectors to be assembled in various configurations.The final version of LAMBDA consists of 102 identical 60 mm×60 mm×120 mm BGO crystals and exhibits a high full-energy peak efficiency exceeding 80%at 0.5∼8 MeV based on a Monte Carlo simulation.Currently,approximately half of the LAMBDA modules have been manufactured.Tests usingγ-ray sources and nuclear reactions demonstrated favorable energy resolution,energy linearity,and efficiency uniformity across the modules.Forty-eight modules have been integrated into the prototype LAMBDA-I.The capability of LAMBDA-I inβ-delayed-decay experiments was evaluated by commissioning measurements using the ^(152)Eu source.展开更多
The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi m...The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.展开更多
In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of...In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993.展开更多
The spatial resolution of the gamma-rays camera was measured on a60Co gamma-rays source with edge method. The gamma-rays camera is consisting with rays-fluorescence convertor, optical imaging system, MCP image intensi...The spatial resolution of the gamma-rays camera was measured on a60Co gamma-rays source with edge method. The gamma-rays camera is consisting with rays-fluorescence convertor, optical imaging system, MCP image intensifier, CCD camera, electronic control system and other devices, and is mainly used in the image diagnostics of the intense pulse radiation sources [1]. Due to the relatively big quantum detective efficiency (DQE) and quantum gain of the gamma-rays, etc., the experimental data were processed by averaging multiple images and fitting curves. According to the experimental results, the spatial resolution MTF (modulation transfer function) at the 10% intensity was about 2lp/mm. Meanwhile, because of the relatively big dispersion effects of the fluorescence transmissions in the scintillator and the optical imaging system, the maximal single-noise ratio (SNR) of the camera was found to be about 5:1. In addition, the spatial resolution of the camera was measured with pulse X-rays with 0.3MeV in average energy and exclusion of the effects of secondary electrons from consideration. Accordingly, the spatial resolution MTF at the 10% intensity was about 5lp/mm. This could be an additional evidence to verify the effects of secondary electrons induced by the 1.25MeV gamma-rays in the scintillator upon the spatial resolution. Based on our analysis, the dispersion sizes of the secondary electrons in the scintillator are about 0.4mm-0.6mm. Comparatively, as indicated by the detailed analysis of the spatial resolutions of the MCP image intensifier and CCD devices, both of them have little effect on the spatial resolution of the gamma-rays camera that could be well neglected.展开更多
Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of gr...Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10<sup>10</sup> Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of <sup>241</sup>Am.展开更多
In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating...In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.展开更多
基金supported by the Strategic Priority Program on Space Science,the Chinese Academy of Sciences,grant Nos.XDA15360102,XDA15360300 and E02212A02Sthe National Natural Science Foundation of China(Project:12061131007)。
文摘The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor(GECAM)mission is designed to monitor the Gamma-Ray Bursts(GRBs)associated with gravitational waves and other high-energy transient sources.The mission consists of two microsatellites which are planned to operate at the opposite sides of the Earth.Each GECAM satellite could detect and localize GRBs in about 8 keV-5 MeV with its 25 Gamma-Ray Detectors(GRDs).In this work,we report the in-flight energy calibration of GRDs using the characteristic gamma-ray lines in the background spectra,and show their performance evolution during the commissioning phase.Besides,a preliminary cross-calibration of energy response with Fermi GBM data is also presented,validating the energy response of GRDs.
基金supported by Department of Physics and GXUNAOC Center for Astrophysics and Space Sciences,Guangxi UniversityThe National Natural Science Foundation of China(Nos.12027803,U1731239,12133003,12175241,U1938201,U1732266)the Guangxi Science Foundation(Nos.2018GXNSFGA281007,2018JJA110048).
文摘POLAR-2 is a gamma-ray burst(GRB)polarimeter that is designed to study the polarization in GRB radiation emissions,aiming to improve our knowledge of related mechanisms.POLAR-2 is expected to utilize an on-board polarimeter that is sensitive to soft X-rays(2-10 keV),called low-energy polarization detector.We have developed a new soft X-ray polari-zation detector prototype based on gas microchannel plates(GMCPs)and pixel chips(Topmetal).The GMCPs have bulk resistance,which prevents charging-up effects and ensures gain stability during operation.The detector is composed of low outgassing materials and is gas-sealed using a laser welding technique,ensuring long-term stability.A modulation factor of 41.28%±0.64% is obtained for a 4.5 keV polarized X-ray beam.A residual modulation of 1.96%±0.58% at 5.9 keV is observed for the entire sensitive area.
基金supported by the Tsinghua University Initiative Scientific Research Program,the National Natural Science Foundation of China(Nos.11633003,12025301,and 11821303)the National Key R&D Program of China(Nos.2018YFA0404502 and 2016YFA040080X).
文摘Gamma-Ray Integrated Detectors(GRID)mis-sion is a student project designed to use multiple gamma-ray detectors carried by nanosatellites(CubeSats),forming a full-time all-sky gamma-ray detection network that monitors the transient gamma-ray sky in the multi-mes-senger astronomy era.A compact CubeSat gamma-ray detector,including its hardware and firmware,was designed and implemented for the mission.The detector employs four Gd 2 Al 2 Ga 3 O 12:Ce(GAGG:Ce)scintillators coupled with four silicon photomultiplier(SiPM)arrays to achieve a high gamma-ray detection efficiency between 10 keV and 2 MeV with low power and small dimensions.The first detector designed by the undergraduate student team onboard a commercial CubeSat was launched into a Sun-synchronous orbit on October 29,2018.The detector was in a normal observation state and accumulated data for approximately one month after on-orbit functional and performance tests,which were conducted in 2019.
文摘Cadmium zinc telluride selenide (CdZnTeSe) is a new semiconductor material for gamma-ray detection and spectroscopy applications at room temperature. It has very high crystal quality compared to similar materials such as cadmium telluride and cadmium zinc telluride. The consistency of peak position in radiation detection devices is important to practical applications. In this paper, we have characterized a CdZnTeSe planar detector for bias voltages in the range of -20 V to -200 V and amplifier shaping time of 2, 3 and 6 μs. The peak position of the 59.6-keV gamma line of <sup>241</sup>Am becomes more stable as the absolute value of the applied voltage increases. The best energy resolution of 8.5% was obtained for the 59.6-keV gamma peak at -160 V bias voltage and 3-μs shaping time. The energy resolution was relatively stable in the -120 V to -200 V range for a 6-μs shaping time. Future work will be focused on the study of the peak position and energy resolution over time.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Sciences (Grant Nos.XDA30050100 and XDA30030000)the National Natural Science Foundation of China (Grant Nos.12173038,11775251,12273042,and 12075258)funded by the Strategic Priority Research Program on Space Science (Grant No.XDA15360000) of the Chinese Academy of Sciences (CAS)。
文摘The Gamma-ray Transient Monitor(GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A(DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 ke V to 1 MeV. The GTM was equipped with five Gamma-ray Transient Probe(GTP) detector modules utilizing a NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP uses a dedicated dual-channel coincident readout design. In this work, we first studied the impact of different coincidence times on the detection efficiency and ultimately selected a 0.5 μs time coincidence window for offline data processing. To test the performance of the GTPs and validate the Monte-Carlo-simulated energy response, we conducted comprehensive ground calibration tests using the Hard X-ray Calibration Facility(HXCF) and radioactive sources, including the energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively present the ground calibration results and validate the design and mass model of the GTP detector, thus providing the foundation for in-flight observations and scientific data analysis.
基金supported by the National Key R&D Program of China(Nos.2022YFA1603300,2018YFA0404401,2023YFA1606701,2022YFA1602301)National Natural Science Foundation of China(Nos.U1867211,12275026,12222514)the CAS Light of West China Program(No.2020-82).
文摘Total absorption gamma-ray spectroscopy(TAGS)is a powerful tool for measuring complexγ transitions,which has been effectively applied to the study of reactor decay heat.This paper presents the design of a new TAGS detector,the large-scale modular BGO detection array(LAMBDA),tailored for measuringβ-decay intensity distributions of fission products.The modular design allows the LAMBDA detectors to be assembled in various configurations.The final version of LAMBDA consists of 102 identical 60 mm×60 mm×120 mm BGO crystals and exhibits a high full-energy peak efficiency exceeding 80%at 0.5∼8 MeV based on a Monte Carlo simulation.Currently,approximately half of the LAMBDA modules have been manufactured.Tests usingγ-ray sources and nuclear reactions demonstrated favorable energy resolution,energy linearity,and efficiency uniformity across the modules.Forty-eight modules have been integrated into the prototype LAMBDA-I.The capability of LAMBDA-I inβ-delayed-decay experiments was evaluated by commissioning measurements using the ^(152)Eu source.
文摘The present study focuses on determination of alpha particles concentration in different samples of toothpaste by using nuclear track detector (CR-39). Nine samples of toothpaste have been collected from local Iraqi markets in Babylon Province. These samples have been chosen according to their most commonly use in Babylon Province. The samples were kept with CR-39 detector for six weeks period and then etched by 6.25 N of NaOH solution at temperature of 60°C for 5 hours. The results of the present work show that Sample 3 (Frosty) found to have a high alpha concentration about four times compared with Sample 4 (Aquafresh) and about 2 - 3 times compared with other samples.
文摘In the present work, uranium concentrations were measured in twenty surface soil samples forselected regions in AI-Anbargovernorate using fission track etch technique, CR-39 track detector was used for registration of induced fission tracks. The results show that, the uranium concentrations ranged from 4.61 ppm, 56.93 Bq/kg (AL-Falluja AL-Jolan District) to 1.81 ppm 22.35 Bq/kg (Anah)with an average 3.42±0.79 ppm, 41.76±9.04 Bq/kg. The present results have shown that the uranium concentrations in the studied surface soil samples were less than the allowed limit 11.7 ppm recommended by UNSCEAR, 1993.
文摘The spatial resolution of the gamma-rays camera was measured on a60Co gamma-rays source with edge method. The gamma-rays camera is consisting with rays-fluorescence convertor, optical imaging system, MCP image intensifier, CCD camera, electronic control system and other devices, and is mainly used in the image diagnostics of the intense pulse radiation sources [1]. Due to the relatively big quantum detective efficiency (DQE) and quantum gain of the gamma-rays, etc., the experimental data were processed by averaging multiple images and fitting curves. According to the experimental results, the spatial resolution MTF (modulation transfer function) at the 10% intensity was about 2lp/mm. Meanwhile, because of the relatively big dispersion effects of the fluorescence transmissions in the scintillator and the optical imaging system, the maximal single-noise ratio (SNR) of the camera was found to be about 5:1. In addition, the spatial resolution of the camera was measured with pulse X-rays with 0.3MeV in average energy and exclusion of the effects of secondary electrons from consideration. Accordingly, the spatial resolution MTF at the 10% intensity was about 5lp/mm. This could be an additional evidence to verify the effects of secondary electrons induced by the 1.25MeV gamma-rays in the scintillator upon the spatial resolution. Based on our analysis, the dispersion sizes of the secondary electrons in the scintillator are about 0.4mm-0.6mm. Comparatively, as indicated by the detailed analysis of the spatial resolutions of the MCP image intensifier and CCD devices, both of them have little effect on the spatial resolution of the gamma-rays camera that could be well neglected.
文摘Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10<sup>10</sup> Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of <sup>241</sup>Am.
文摘In this paper full-energy peak (photopeak) efficiency and photopeak attenuation coefficient of 3'' × 3'' NaI(Tl) well-type scintillation detector were calculated using gamma-rayisotropic radiating point sources (with photon energy: 0.245, 0.344, 0.662, 0.779, 0.964, 1.1732, 1.333 and 1.408 MeV) placed outside the detector well. These energies were obtained from <sup>152</sup>Eu, <sup>137</sup>Cs and <sup>60</sup>Co. The relations between the full energy peak efficiency and photopeak attenuation coefficients, were plotted vs. photon energy at different sources to detector distance, and it found that the full energy peak efficiency decreased by increasing the distance between the source and the detector.