期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Fish-Eye Image Distortion Correction Based on Adaptive Partition Fitting 被引量:2
1
作者 Yibin He Wenhao Xiong +3 位作者 Hanxin Chen Yuchen Chen Qiaosen Dai Panpan Tuand Gaorui Hu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2021年第1期379-396,共18页
The acquisition of images with a fish-eye lens can cause serious image distortion because of the short focal length of the lens.As a result,it is difficult to use the obtained image information.To make use of the effe... The acquisition of images with a fish-eye lens can cause serious image distortion because of the short focal length of the lens.As a result,it is difficult to use the obtained image information.To make use of the effective information in the image,these distorted imagesmust first be corrected into the perspective of projection images in accordance with the human eye’s observation abilities.To solve this problem,this study presents an adaptive classification fitting method for fish-eye image correction.The degree of distortion in the image is represented by the difference value of the distances fromthe distorted point and undistorted point to the center of the image.The target points selected in the image are classified by the difference value.In the areas classified by different distortion differences,different parameter curves were used for fitting and correction.The algorithm was verified through experiments.The results showed that this method has a substantial correction effect on fish-eye images taken by different fish-eye lenses. 展开更多
关键词 Fish-eye lens image distortion distortion difference adaptive partition fitting
下载PDF
Central RF frequency measurement of the HLS-Ⅱ storage ring
2
作者 郑佳俊 杨永良 +4 位作者 孙葆根 吴芳芳 程超才 唐凯 韦隽昊 《Chinese Physics C》 SCIE CAS CSCD 2016年第4期125-130,共6页
Central RF frequency is a key parameter of storage rings. This paper presents the measurement of central RF frequency of the HLS-Ⅱ storage ring with the sextupole modulation method. Firstly, the basis of central RF f... Central RF frequency is a key parameter of storage rings. This paper presents the measurement of central RF frequency of the HLS-Ⅱ storage ring with the sextupole modulation method. Firstly, the basis of central RF frequency measurement of the electron storage ring is briefly introduced. Then, the error sources and the optimized measurement method for the HLS-Ⅱ storage ring are discussed. The workflow of a self-compiled Matlab script used in central RF frequency measurement is also described. Finally, the results achieved by using two data processing methods to cross-check each other are shown. The measured value of the central RF frequency demonstrates that the circumference deviation of the HLS-Ⅱ storage ring is less than 1 mm. 展开更多
关键词 deviation briefly workflow circumference directions storage ring sections partition fitting shaking
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部