The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-to...The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.展开更多
In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-Syn...In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-SynRM).This estimator is utilized for estimating the rotor speed and the load torque as well as can solve the speed sensor fault problem,as the feedback speed information is obtained directly from the virtual sensor.In addition,this technique is able to enhance the 5-phase PMa-SynRM performance by estimating the load torque for the real time compensation.The stability analysis of the proposed estimator is performed via Schur complement along with Lyapunov analysis.Furthermore,for improving the 5-phase PMa-SynRM performance,five super-twisting sliding mode controllers(ST-SMCs)are employed with providing a robust response without the impacts of high chattering problem.A super-twisting sliding mode speed controller(ST-SMSC)is employed for controlling the PMa-SynRM rotor speed,and four super-twisting sliding mode current controllers(ST-SMCCs)are employed for controlling the 5-phase PMa-SynRM currents.The stability analysis and the experimental results indicate the effectiveness along with feasibility of the proposed RTSE and the ST-SMSC with ST-SMCCs approach for a 750-W 5-phase PMa-SynRM under load disturbance,parameters variations,single open-phase fault,and adjacent two-phase open circuit fault conditions.展开更多
Based on the principle of direct torque control,a DTC(Direct Torque Control)system with five-phase induction motor has been studied.Providing direct control of stator flux and electromagnetic torque by optimized volta...Based on the principle of direct torque control,a DTC(Direct Torque Control)system with five-phase induction motor has been studied.Providing direct control of stator flux and electromagnetic torque by optimized voltage vector,five-phase induction motor enhances flexibility of the invert states selection by increasing the number of voltage vectors,resulting in more precise control of stator flux and electromagnetic torque.The model of DTC for five-phase induction motor is constructed on equations and the method of approximate circle of torque track is used to conduct the simulation analysis of the system.The simulation results demonstrate that the DTC for five-phase induction motor control has merits of little calculation compared with vector control,simple structure,fast response and greater dynamic performance.展开更多
Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control ...Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control of multiphase motor drives.To explore the inherent link,the pros and cons of two strategies,the performance analysis and comparative investigation of MPCC and MPTC are conducted through a five-phase permanent magnet synchronous motor with open-phase fault.In MPCC,the currents of fundamental and harmonic subspaces are simultaneously employed and constrained for a combined regulation of the open-circuit fault drive.In MPTC,apart from the torque and the stator flux related to fundamental subspace,the x-y currents are also considered and predicted to achieve the control of harmonic subspace.The principles of two methods are demonstrated in detail and the link is explored in terms of the cost function.Besides,the performance by two methods is experimentally assessed in terms of steady-state,transition,and dynamic tests.Finally,the advantages and disadvantages of each method are concluded.展开更多
In addition to the characteristics of a conventional motor, a novel direct-drive double-stator permanent-magnet brushless motor proposed can operate in the state of either a generator or a motor as appropriate. Throug...In addition to the characteristics of a conventional motor, a novel direct-drive double-stator permanent-magnet brushless motor proposed can operate in the state of either a generator or a motor as appropriate. Through numerical calculation and analysis, the output torque of double-stator permanent-magnet brushless motor of the same volume as the traditional machine is discussed, and the reduction of torque ripple by using the structure features of this motor is investigated. The results indicate that lower torque ripple under the condition of ideal effective torque can be obtained by the rational design of motor. The prototype motors tested show that this kind of motor structure has a higher power density.展开更多
This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM)motor for high-reliability applications under the two most popular control schemes,name...This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM)motor for high-reliability applications under the two most popular control schemes,namely,field-oriented control(FOC)and direct torque control(DTC)based on stator-flux orientation.Firstly,the new motor topology and structural characteristics are briefly presented.Secondly,the d-and q-axis for the FT-FSPM motor are defined,which is crucial to the mathematical model and control scheme,and the mathematical models are derived.Then,two control schemes,i.e.,FOC and DTC,and the main system are proposed.The operational principles of the two control schemes are presented,and space vector pulse width modulation(SVPWM)based on four neighboring vectors is adopted to reduce current harmonics and torque ripples.Finally,the simulated and experimental results are given,and performance analysis of the two control schemes are compared and discussed.The results reveal that FOC scheme has the sinusoidal phase current and low torque ripples,while the DTC scheme has fast dynamic response,verifying the effectiveness of the two proposed control schemes.This paper is a primary investigation for more possible improvements in the control schemes of the five-phase FS-FTPM motor.展开更多
Transverse-flux with high efficiency has been applied in Stirling engine and permanent magnet synchronous linear generator system,however it is restricted for large application because of low and complex process.A nov...Transverse-flux with high efficiency has been applied in Stirling engine and permanent magnet synchronous linear generator system,however it is restricted for large application because of low and complex process.A novel type of cylindrical,non-overlapping,transverse-flux,and permanent-magnet linear motor(TFPLM) is investigated,furthermore,a high power factor and less process complexity structure research is developed.The impact of magnetic leakage factor on power factor is discussed,by using the Finite Element Analysis(FEA) model of stirling engine and TFPLM,an optimization method for electro-magnetic design of TFPLM is proposed based on magnetic leakage factor.The relation between power factor and structure parameter is investigated,and a structure parameter optimization method is proposed taking power factor maximum as a goal.At last,the test bench is founded,starting experimental and generating experimental are performed,and a good agreement of simulation and experimental is achieved.The power factor is improved and the process complexity is decreased.This research provides the instruction to design high-power factor permanent-magnet linear generator.展开更多
This paper deals with the design of high power – low dimensions axial-flux permanent-magnet motor intended for trac-tion application. First, two motor configurations are analytically designed and compared using finit...This paper deals with the design of high power – low dimensions axial-flux permanent-magnet motor intended for trac-tion application. First, two motor configurations are analytically designed and compared using finite element calcula-tion. Then, the configuration yielding the best performances is integrated and modelled with the whole traction chain under MATLAB/SIMULINK environment in order to demonstrate the motor operation on a large speed band.展开更多
A novel dual-side primary permanent-magnet vernier linear(DS-PPMVL)motors is proposed.The novelty of the proposed motors is the design of asymmetric consequent poles on the mover,which can effectively enforce the flux...A novel dual-side primary permanent-magnet vernier linear(DS-PPMVL)motors is proposed.The novelty of the proposed motors is the design of asymmetric consequent poles on the mover,which can effectively enforce the flux-modulation effect and improve the thrust force performance.First,the topologies and operation principle are introduced.Subsequently,the structure relationships between the existing and proposed motors are discussed.Then,a unified analytical model is built.Accordingly,the magnetic field generated by the consequent pole is calculated.Meanwhile,the performance improvement mechanism with the asymmetric consequent pole is analyzed.To improve the efficiency of motor optimization,multi-objective optimization method is adopted to obtain the global optimal solution combination of structure parameters.The proposed motors exhibit higher thrust force,higher force density,less PM consumption,and better overload performance than the existing DS-PPMVL motor.Finally,experiments are conducted based on the existing prototype to verify the accuracy of the design and analysis.展开更多
When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and p...When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results.展开更多
Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor fault...Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor faults occur. But there is scarcely any research focusing on fault diagnosis and fault-tolerant control of Hall sensor used in PMSM. From this standpoint, the Hall sensor faults which may occur during the PMSM operating are theoretically analyzed. According to the analysis results, the fault diagnosis algorithm of Hall sensor, which is based on three rules, is proposed to classify the fault phenomena accurately. The rotor phase estimation algorithms, based on one or two Hall sensor(s), are initialized to engender the fault-tolerant control algorithm. The fault diagnosis algorithm can detect 60 Hall fault phenomena in total as well as all detections can be fulfilled in 1/138 rotor rotation period. The fault-tolerant control algorithm can achieve a smooth torque production which means the same control effect as normal control mode (with three Hall sensors). Finally, the PMSM bench test verifies the accuracy and rapidity of fault diagnosis and fault-tolerant control strategies. The fault diagnosis algorithm can detect all Hall sensor faults promptly and fault-tolerant control algorithm allows the PMSM to face failure conditions of one or two Hall sensor(s). In addition, the transitions between health-control and fault-tolerant control conditions are smooth without any additional noise and harshness. Proposed algorithms can deal with the Hall sensor faults of PMSM in real applications, and can be provided to realize the fault diagnosis and fault-tolerant control of PMSM.展开更多
A primary permanent-magnet linear motor (PPMLM) has a robust secondary structure and high force density and is appropriate for direct-drive mechanical press. The structure of a four-side PPMLM drive press is presented...A primary permanent-magnet linear motor (PPMLM) has a robust secondary structure and high force density and is appropriate for direct-drive mechanical press. The structure of a four-side PPMLM drive press is presented based on our previous research. The entire press control system is constructed to realize various flexible forming processes. The control system scheme is determined in accordance with the mathematical model of PPMLM, and active disturbance rejection control is implemented in the servo controller. Field-circuit coupling simulation is applied to estimate the system’s performance. Then, a press prototype with 6 kN nominal force is fabricated, and the hardware platform of the control system is constructed for experimental study. Punch strokes with 0.06 m displacement are implemented at trapezoidal speeds of 0.1 and 0.2 m/s;the dynamic position tracking errors are less than 0.45 and 0.82 mm, respectively. Afterward, continuous reciprocating strokes are performed, and the positioning errors at the bottom dead center are less than 0.015 mm. Complex pulse trajectories are also achieved. The proposed PPMLM drive press exhibits a fast dynamic response and favorable tracking precision and is suitable for various forming processes.展开更多
In this study,a composite strategy based on sliding-mode control( SMC) is employed in a permanent-magnet synchronous motor vector control system to improve the system robustness performance against parameter variation...In this study,a composite strategy based on sliding-mode control( SMC) is employed in a permanent-magnet synchronous motor vector control system to improve the system robustness performance against parameter variations and load disturbances. To handle the intrinsic chattering of SMC,an adaptive law and an extended state observer( ESO) are utilized in the speed SMC controller design. The adaptive law is used to estimate the internal parameter variations and compensate for the disturbances caused by model uncertainty. In addition,the ESO is introduced to estimate the load disturbance in real time. The estimated value is used as a feed-forward compensator for the speed adaptive sliding-mode controller to further increase the system's ability to resist disturbances. The proposed composite method,which combines adaptive SMC( ASMC) and ESO,is compared with PI control and ASMC. Both the simulation and experimental results demonstrate that the proposed method alleviates the chattering of SMC systems and improves the dynamic response and robustness of the speed control system against disturbances.展开更多
In this paper,a novel bipolar transverse flux motor with stator permanent magnet excitation is proposed based on the summary and analysis of the transverse flux motor and stator permanent magnet motor research achieve...In this paper,a novel bipolar transverse flux motor with stator permanent magnet excitation is proposed based on the summary and analysis of the transverse flux motor and stator permanent magnet motor research achievements in recent years.It has been shown that the motor realizes the bipolar winding flux through the detailed analysis.The motor can be used as an inwheel motor in electric vehicles because of its external rotor and permanent magnets mounted on the stator radial surface.Secondly the basic structure and working principle of the motor are introduced.Then the relationship between the motor power and its dimensions is deduced.Thirdly the 3 dimensional finite element method(3D FEM)is used to analyze the static and transient characteristics,including the no-load magnetic field distribution and winding back EMF.Finally a three-phase 600W prototype has been made and the experimental analysis is carried out.展开更多
This paper focuses on modeling and perfor- mance predetermination of a photovoltaic (PV) system with a boost converter fed permanent magnet direct current (PMDC) motor-centrifugal pump load, taking the con- verter...This paper focuses on modeling and perfor- mance predetermination of a photovoltaic (PV) system with a boost converter fed permanent magnet direct current (PMDC) motor-centrifugal pump load, taking the con- verter losses into account. Sizing is done based on the maximum power generated by the PV array at the average irradiation. Hence optimum sizing of the PV array for the given irradiation at the geographical location of interest is obtained using the predetermined values. The analysis presented here involves systems employing maximum power point tracking (MPPT) as they are more efficient than directly coupled systems. However, the voltage and power of the motor might rise above rated values for irradiations greater than the average when employing MPPT, hence a control scheme has been proposed to protect the PMDC motor from being damaged during these conditions. This control scheme appropriately chooses the optimum operating point of the system, ensuring long-term sustained operation. The numerical simulation of the system is performed in Matlab/Simulink and is validated with experimental results obtained from a 180 V, 0.5 hp PMDC motor coupled to a centrifugal pump. The operation of the system with the proposed control scheme is verified by varying the irradiation levels and the relevant results are presented.展开更多
文摘The multi-phase motor drive system with multiple H-bridge power supply has high fault tolerance,which is widely used in aerospace,electric vehicle,ship integrated power system and other fields.In this paper,a fault-tolerant control strategy based on decoupling control and stator current compensation is proposed for the propulsion system of five-phase PMSM with independent neutrals.Firstly,the mathematical model of PMSM is established by using vector space decoupling method;Secondly,a stator current compensation method is adopted to carry out fault-tolerant control after the motor has single-phase and two-phase open-circuit faults and the fault-tolerant control system based on decoupling control is established;Finally,the decoupling control model and the fault-tolerant control of stator current compensation are verified by the simulation and experiment.The simulation and experiment results show that the method can reduce the torque ripple caused by the stator winding open-circuit fault,and the operation performance of the motor under fault condition is significantly improved.
文摘In this paper,a robust torque speed estimator(RTSE)for linear parameter changing(LPC)system is proposed and designed for an encoderless five-phase permanent magnet assisted synchronous reluctance motor(5-phase PMa-SynRM).This estimator is utilized for estimating the rotor speed and the load torque as well as can solve the speed sensor fault problem,as the feedback speed information is obtained directly from the virtual sensor.In addition,this technique is able to enhance the 5-phase PMa-SynRM performance by estimating the load torque for the real time compensation.The stability analysis of the proposed estimator is performed via Schur complement along with Lyapunov analysis.Furthermore,for improving the 5-phase PMa-SynRM performance,five super-twisting sliding mode controllers(ST-SMCs)are employed with providing a robust response without the impacts of high chattering problem.A super-twisting sliding mode speed controller(ST-SMSC)is employed for controlling the PMa-SynRM rotor speed,and four super-twisting sliding mode current controllers(ST-SMCCs)are employed for controlling the 5-phase PMa-SynRM currents.The stability analysis and the experimental results indicate the effectiveness along with feasibility of the proposed RTSE and the ST-SMSC with ST-SMCCs approach for a 750-W 5-phase PMa-SynRM under load disturbance,parameters variations,single open-phase fault,and adjacent two-phase open circuit fault conditions.
文摘Based on the principle of direct torque control,a DTC(Direct Torque Control)system with five-phase induction motor has been studied.Providing direct control of stator flux and electromagnetic torque by optimized voltage vector,five-phase induction motor enhances flexibility of the invert states selection by increasing the number of voltage vectors,resulting in more precise control of stator flux and electromagnetic torque.The model of DTC for five-phase induction motor is constructed on equations and the method of approximate circle of torque track is used to conduct the simulation analysis of the system.The simulation results demonstrate that the DTC for five-phase induction motor control has merits of little calculation compared with vector control,simple structure,fast response and greater dynamic performance.
基金supported in part by the Fundamental Research Funds for Central Universities under Grant JUSRP121020the Natural Science Foundation of Jiangsu Province under Grant BK20210475。
文摘Model predictive current control(MPCC)and model predictive torque control(MPTC)are two derivatives of model predictive control.These two control methods have demonstrated their strengths in the fault-tolerant control of multiphase motor drives.To explore the inherent link,the pros and cons of two strategies,the performance analysis and comparative investigation of MPCC and MPTC are conducted through a five-phase permanent magnet synchronous motor with open-phase fault.In MPCC,the currents of fundamental and harmonic subspaces are simultaneously employed and constrained for a combined regulation of the open-circuit fault drive.In MPTC,apart from the torque and the stator flux related to fundamental subspace,the x-y currents are also considered and predicted to achieve the control of harmonic subspace.The principles of two methods are demonstrated in detail and the link is explored in terms of the cost function.Besides,the performance by two methods is experimentally assessed in terms of steady-state,transition,and dynamic tests.Finally,the advantages and disadvantages of each method are concluded.
文摘In addition to the characteristics of a conventional motor, a novel direct-drive double-stator permanent-magnet brushless motor proposed can operate in the state of either a generator or a motor as appropriate. Through numerical calculation and analysis, the output torque of double-stator permanent-magnet brushless motor of the same volume as the traditional machine is discussed, and the reduction of torque ripple by using the structure features of this motor is investigated. The results indicate that lower torque ripple under the condition of ideal effective torque can be obtained by the rational design of motor. The prototype motors tested show that this kind of motor structure has a higher power density.
基金Supported by Key Research and Development Program of Jiangsu Province under Grant BE2018107,Natural Science Foundation of Jiangsu Province under Grant BK20171298Natural Science Foundation of Jiangsu Higher Education Institutions under Grant 18KJB470008.
文摘This paper presents a comparative performance analysis of a new five-phase fault-tolerant flux-switching permanent-magnet(FT-FSPM)motor for high-reliability applications under the two most popular control schemes,namely,field-oriented control(FOC)and direct torque control(DTC)based on stator-flux orientation.Firstly,the new motor topology and structural characteristics are briefly presented.Secondly,the d-and q-axis for the FT-FSPM motor are defined,which is crucial to the mathematical model and control scheme,and the mathematical models are derived.Then,two control schemes,i.e.,FOC and DTC,and the main system are proposed.The operational principles of the two control schemes are presented,and space vector pulse width modulation(SVPWM)based on four neighboring vectors is adopted to reduce current harmonics and torque ripples.Finally,the simulated and experimental results are given,and performance analysis of the two control schemes are compared and discussed.The results reveal that FOC scheme has the sinusoidal phase current and low torque ripples,while the DTC scheme has fast dynamic response,verifying the effectiveness of the two proposed control schemes.This paper is a primary investigation for more possible improvements in the control schemes of the five-phase FS-FTPM motor.
基金Supported by National Natural Science Foundation of China(Grant No.50877013)
文摘Transverse-flux with high efficiency has been applied in Stirling engine and permanent magnet synchronous linear generator system,however it is restricted for large application because of low and complex process.A novel type of cylindrical,non-overlapping,transverse-flux,and permanent-magnet linear motor(TFPLM) is investigated,furthermore,a high power factor and less process complexity structure research is developed.The impact of magnetic leakage factor on power factor is discussed,by using the Finite Element Analysis(FEA) model of stirling engine and TFPLM,an optimization method for electro-magnetic design of TFPLM is proposed based on magnetic leakage factor.The relation between power factor and structure parameter is investigated,and a structure parameter optimization method is proposed taking power factor maximum as a goal.At last,the test bench is founded,starting experimental and generating experimental are performed,and a good agreement of simulation and experimental is achieved.The power factor is improved and the process complexity is decreased.This research provides the instruction to design high-power factor permanent-magnet linear generator.
文摘This paper deals with the design of high power – low dimensions axial-flux permanent-magnet motor intended for trac-tion application. First, two motor configurations are analytically designed and compared using finite element calcula-tion. Then, the configuration yielding the best performances is integrated and modelled with the whole traction chain under MATLAB/SIMULINK environment in order to demonstrate the motor operation on a large speed band.
基金Supported in part by the National Natural Science Foundation of China under Grant 51977099in part by the Natural Science Foundation of Jiangsu Province under Grant BK20191225.
文摘A novel dual-side primary permanent-magnet vernier linear(DS-PPMVL)motors is proposed.The novelty of the proposed motors is the design of asymmetric consequent poles on the mover,which can effectively enforce the flux-modulation effect and improve the thrust force performance.First,the topologies and operation principle are introduced.Subsequently,the structure relationships between the existing and proposed motors are discussed.Then,a unified analytical model is built.Accordingly,the magnetic field generated by the consequent pole is calculated.Meanwhile,the performance improvement mechanism with the asymmetric consequent pole is analyzed.To improve the efficiency of motor optimization,multi-objective optimization method is adopted to obtain the global optimal solution combination of structure parameters.The proposed motors exhibit higher thrust force,higher force density,less PM consumption,and better overload performance than the existing DS-PPMVL motor.Finally,experiments are conducted based on the existing prototype to verify the accuracy of the design and analysis.
基金the National Natural Science Foundation of China(52077097,52025073,and 51991383)in part by the Natural Science Research Project of Higher Education Institutions of Jiangsu Province(20KJA470003)in part by the Priority Academic Program Development of Jiangsu Higher Education Institutions.
文摘When a short-circuit fault occurs in a phase,the faulty phase needs to be removed artificially from the system because of the loss of the capability to generate torque.In this case,both the short-circuit current and phase-loss fault would generate additional torque ripples.In this study,a novel fault-tolerant control strategy is introduced to achieve low torque ripple operation of five-phase fault-tolerant permanent magnet synchronous motors with trapezoidal back electromotive force(FTPMSM-TEMF)in the event of a short-circuit fault.The key concept of this method is to compensate for the torque ripples caused by the short-circuit current and the adverse effect of the phase-loss.Based on the torque expression under fault conditions,the torque ripple caused by the short-circuit current can be offset by injecting a certain pulsating component into the torque expression in the phase-loss condition.This would result in smooth operation under fault conditions.Moreover,to track the fault-tolerant alternating currents,the model of the deadbeat current predictive control is extended and restructured for the fault condition.The effectiveness and feasibility of the proposed fault-tolerant strategy are verified by experimental results.
基金supported by National Natural Science Foundation of China(Grant No. 51275264)National Hi-tech Research and Development Program of China(863 Program, Grant No. 2011AA11A269)
文摘Hall sensor is widely used for estimating rotor phase of permanent magnet synchronous motor(PMSM). And rotor position is an essential parameter of PMSM control algorithm, hence it is very dangerous if Hall senor faults occur. But there is scarcely any research focusing on fault diagnosis and fault-tolerant control of Hall sensor used in PMSM. From this standpoint, the Hall sensor faults which may occur during the PMSM operating are theoretically analyzed. According to the analysis results, the fault diagnosis algorithm of Hall sensor, which is based on three rules, is proposed to classify the fault phenomena accurately. The rotor phase estimation algorithms, based on one or two Hall sensor(s), are initialized to engender the fault-tolerant control algorithm. The fault diagnosis algorithm can detect 60 Hall fault phenomena in total as well as all detections can be fulfilled in 1/138 rotor rotation period. The fault-tolerant control algorithm can achieve a smooth torque production which means the same control effect as normal control mode (with three Hall sensors). Finally, the PMSM bench test verifies the accuracy and rapidity of fault diagnosis and fault-tolerant control strategies. The fault diagnosis algorithm can detect all Hall sensor faults promptly and fault-tolerant control algorithm allows the PMSM to face failure conditions of one or two Hall sensor(s). In addition, the transitions between health-control and fault-tolerant control conditions are smooth without any additional noise and harshness. Proposed algorithms can deal with the Hall sensor faults of PMSM in real applications, and can be provided to realize the fault diagnosis and fault-tolerant control of PMSM.
基金This research was financially supported by the National Natural Science Foundation of China(Grant No.51605363)China Postdoctoral Science Foundation(Grant No.2016M590922)Shaanxi Postdoctoral Research Project Funding.
文摘A primary permanent-magnet linear motor (PPMLM) has a robust secondary structure and high force density and is appropriate for direct-drive mechanical press. The structure of a four-side PPMLM drive press is presented based on our previous research. The entire press control system is constructed to realize various flexible forming processes. The control system scheme is determined in accordance with the mathematical model of PPMLM, and active disturbance rejection control is implemented in the servo controller. Field-circuit coupling simulation is applied to estimate the system’s performance. Then, a press prototype with 6 kN nominal force is fabricated, and the hardware platform of the control system is constructed for experimental study. Punch strokes with 0.06 m displacement are implemented at trapezoidal speeds of 0.1 and 0.2 m/s;the dynamic position tracking errors are less than 0.45 and 0.82 mm, respectively. Afterward, continuous reciprocating strokes are performed, and the positioning errors at the bottom dead center are less than 0.015 mm. Complex pulse trajectories are also achieved. The proposed PPMLM drive press exhibits a fast dynamic response and favorable tracking precision and is suitable for various forming processes.
基金Supported by the National Natural Science Foundation of China(No.11603024)
文摘In this study,a composite strategy based on sliding-mode control( SMC) is employed in a permanent-magnet synchronous motor vector control system to improve the system robustness performance against parameter variations and load disturbances. To handle the intrinsic chattering of SMC,an adaptive law and an extended state observer( ESO) are utilized in the speed SMC controller design. The adaptive law is used to estimate the internal parameter variations and compensate for the disturbances caused by model uncertainty. In addition,the ESO is introduced to estimate the load disturbance in real time. The estimated value is used as a feed-forward compensator for the speed adaptive sliding-mode controller to further increase the system's ability to resist disturbances. The proposed composite method,which combines adaptive SMC( ASMC) and ESO,is compared with PI control and ASMC. Both the simulation and experimental results demonstrate that the proposed method alleviates the chattering of SMC systems and improves the dynamic response and robustness of the speed control system against disturbances.
基金Supported by the Anhui Natural Science Foundation of China(1508085ME87)Natural Science Foundation of Hefei University(06KY010ZR).
文摘In this paper,a novel bipolar transverse flux motor with stator permanent magnet excitation is proposed based on the summary and analysis of the transverse flux motor and stator permanent magnet motor research achievements in recent years.It has been shown that the motor realizes the bipolar winding flux through the detailed analysis.The motor can be used as an inwheel motor in electric vehicles because of its external rotor and permanent magnets mounted on the stator radial surface.Secondly the basic structure and working principle of the motor are introduced.Then the relationship between the motor power and its dimensions is deduced.Thirdly the 3 dimensional finite element method(3D FEM)is used to analyze the static and transient characteristics,including the no-load magnetic field distribution and winding back EMF.Finally a three-phase 600W prototype has been made and the experimental analysis is carried out.
文摘This paper focuses on modeling and perfor- mance predetermination of a photovoltaic (PV) system with a boost converter fed permanent magnet direct current (PMDC) motor-centrifugal pump load, taking the con- verter losses into account. Sizing is done based on the maximum power generated by the PV array at the average irradiation. Hence optimum sizing of the PV array for the given irradiation at the geographical location of interest is obtained using the predetermined values. The analysis presented here involves systems employing maximum power point tracking (MPPT) as they are more efficient than directly coupled systems. However, the voltage and power of the motor might rise above rated values for irradiations greater than the average when employing MPPT, hence a control scheme has been proposed to protect the PMDC motor from being damaged during these conditions. This control scheme appropriately chooses the optimum operating point of the system, ensuring long-term sustained operation. The numerical simulation of the system is performed in Matlab/Simulink and is validated with experimental results obtained from a 180 V, 0.5 hp PMDC motor coupled to a centrifugal pump. The operation of the system with the proposed control scheme is verified by varying the irradiation levels and the relevant results are presented.