期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Carbon Dioxide Fixation Method for Electrosynthesis of Benzoic Acid from Chlorobenzene
1
作者 A.J.Aishah M.A.Hartini +4 位作者 S.Normala A.M.Norhuda H.H.N Hanis H.M.Razif T.Sugeng 《Journal of Natural Gas Chemistry》 EI CAS CSCD 2007年第3期273-277,共5页
Carbon dioxide fixation technique was developed as an alternative dechlorination method of chlorobenzenes. Electrolysis of chlorobenzene was carried out in a one-compartment cell fitted with an aluminium anode and a p... Carbon dioxide fixation technique was developed as an alternative dechlorination method of chlorobenzenes. Electrolysis of chlorobenzene was carried out in a one-compartment cell fitted with an aluminium anode and a platinum cathode. Electrolysis in N, N-dimethylformamide (DMF) solution containing 0.1 M of tetrapropylammonium bromide (TPAB) at 0 ℃, 100 ml/min of CO2 flow rate and 120 mA/cm^2 of current density was found to be the optimum conditions of this electrocarboxylation, which gave 72% yield of benzoic acid from chlorobenzene. These conditions were then applied to 1,2-dichlorobenzene and 1,3-dichlorobenzene in order to convert them to their corrcsponding benzoic acids. 展开更多
关键词 carbon dioxide fixation method ELECTROSYNTHESIS CHLOROBENZENE benzoic acid
下载PDF
Effect of Wafer Size on the Film Internal Stress Measurement by Wafer Curvature Method 被引量:1
2
作者 江帆 CHEN Shang +1 位作者 冷永祥 HUANG Nan 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2016年第1期93-99,共7页
Wafer curvature method has been applied to determine the internal stress in the films using Stoney's equation.During the film deposition,the wafer fixation on the sample holder will restrict the deformation of the re... Wafer curvature method has been applied to determine the internal stress in the films using Stoney's equation.During the film deposition,the wafer fixation on the sample holder will restrict the deformation of the rectangle-shaped wafer,which may result in the stress datum difference along length and width direction.In this paper,the effect of wafer size and the wafer fixation on the TiN film internal stress measured by wafer curvature method was discussed.The rectangle-shaped wafers with different length/width ratios(L/W=1:1,2:1,3:1 and 4:1) were fixed as a cantilever beam.After the TiN films deposition,the profiles of the film/wafer were measured using a stylus profilometer and then the internal stress was calculated using the Stoney equation in the film.The results showed that the fixed end of the wafers limited to some degree the curvature of the wafers along the width direction.For film internal stress measured by wafer curvature method,the wafer profile should be scanned along the length direction and the scan distance should be greater than or equal to half of wafer length.When the length/width ratio of the wafer reached 3:1,the wafer curvature and the calculated stress were basically the same at different positions along the length direction.For film internal stress measured by wafer curvature method,it was recommended that the length/width ratio of wafer should be considered to be greater than or equal to 3:1,and the deformed profile was scanned along the length direction. 展开更多
关键词 film internal stress wafer curvature method wafer size wafer fixation
下载PDF
Postoperative Fracture Healing Effects of Locking Compression Plate for the Treatment of Limb Fractures
3
作者 Bin Zhao Jingli Dou +1 位作者 Rongcai Zhang Mingming Wang 《Journal of Clinical and Nursing Research》 2021年第3期24-27,共4页
Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in ou... Objectives To study the effects of applying locking compression plates in the treatment of patients with limb fractures on postoperative fracture healing.Methods:115 patients with limb fractures who were treated in our hospital from November 2019 to November 2020 were selected.In order to study the effective treatment method,the random-number table method was used in this study to divide the patients into two groups,namely the experimental group and the control group,and the locking compression plate treatment method and the pure plate and screw internal fixation treatment method were administered respectively to study their clinical application effects.Results:Compared with the control group,patients in the experimental group had a lower incidence of complications,shorter hospitalizations and shorter recovery time.Meanwhile,the experimental group had a better quality of recovery,and all data were significantly different from those of the control group,P<0.05,the intervention effect of the experimental group was better.Conclusion:The application of the locking compression plate in the treatment of patients with limb fractures is more conducive to promoting the postoperative healing of the patients'fractures,reducing the incidence of postoperative complications,and promoting the rapid recovery of patients,which has positive significance for clinical development. 展开更多
关键词 Locking compression plate treatment method Simple plate and screw internal fixation treatment method Patients with limb fractures
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部