Correlation between current and cross-sectional area of parallel fixed-movable dual electrodes in ESC
1
作者 Li-ting Zhao Yun-long Xiong +2 位作者 Rui Chen Zeng-rui Wang An-guo Wang 《China Foundry》 SCIE 2020年第3期245-249,共5页
Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to desc... Electroslag casting with parallel fixed-movable dual electrodes is a new method for achieving better quality of castings in complex mold cavities.In this work,a mathematical model,y=kx^2+(k+1)x,was established to describe the ideal correlation between the current ratio(y)and the cross-sectional area ratio(x)of the dual electrodes,where k is the filling ratio.Investigation was conducted on the electroslag casting process with dual electrodes of various cross-sectional areas,but at a constant k value.The experimental results indicated that the ideal correlation was obtained at the stable casting stage,and the fitting results were consistent with the experimental results at certain k values.The experimental findings show that better castings can be obtained when the current ratio is greater than 1.536 and the cross-sectional area ratio is greater than 0.5. 展开更多
关键词 electroslag casting fixed-movable dual electrode current ratio cross-sectional area ratio