Improving Heat Transfer in Parabolic Trough Solar Collectors by Magnetic Nanofluids
1
作者 Ritesh Singh Abhishek Gupta +2 位作者 Akshoy Ranjan Paul Bireswar Paul Suvash C.Saha 《Energy Engineering》 EI 2024年第4期835-848,共14页
A parabolic trough solar collector(PTSC)converts solar radiation into thermal energy.However,low thermal efficiency of PTSC poses a hindrance to the deployment of solar thermal power plants.Thermal performance of PTSC... A parabolic trough solar collector(PTSC)converts solar radiation into thermal energy.However,low thermal efficiency of PTSC poses a hindrance to the deployment of solar thermal power plants.Thermal performance of PTSC is enhanced in this study by incorporating magnetic nanoparticles into the working fluid.The circular receiver pipe,with dimensions of 66 mm diameter,2 mm thickness,and 24 m length,is exposed to uniform temperature and velocity conditions.The working fluid,Therminol-66,is supplemented with Fe3O4 magnetic nanoparticles at concentrations ranging from 1%to 4%.The findings demonstrate that the inclusion of nanoparticles increases the convective heat transfer coefficient(HTC)of the PTSC,with higher nanoparticle volume fractions leading to greater heat transfer but increased pressure drop.The thermal enhancement factor(TEF)of the PTSC is positively affected by the volume fraction of nanoparticles,both with and without a magnetic field.Notably,the scenario with a 4%nanoparticle volume fraction and a magnetic field strength of 250 G exhibits the highest TEF,indicating superior thermal performance.These findings offer potential avenues for improving the efficiency of PTSCs in solar thermal plants by introducing magnetic nanoparticles into the working fluid. 展开更多
关键词 Parabolic trough solar collector(PTSC) magnetic nanofluid(MNF) heat transfer convective heat transfer coefficient(HTC) thermal enhancement factor(TEF)
下载PDF
Application of entransy theory in the heat transfer optimization of flat-plate solar collectors 被引量:5
2
作者 LI QinYi CHEN Qun 《Chinese Science Bulletin》 SCIE CAS 2012年第2期299-306,共8页
The flat-plate solar collector is an important component in solar-thermal systems,and its heat transfer optimization is of great significance in terms of the efficiency of energy utilization.However,most existing flat... The flat-plate solar collector is an important component in solar-thermal systems,and its heat transfer optimization is of great significance in terms of the efficiency of energy utilization.However,most existing flat-plate collectors adopt metallic absorber plates with uniform thickness,which often works against energy conservation.In this paper,to achieve the optimal heat transfer performance,we optimized the thickness distribution of the absorber with the constraint of fixed total material volume employing entransy theory.We first established the correspondence between the collector efficiency and the loss of entransy,and then proposed the constrained extreme-value problem and deduced the optimization criterion,namely a uniform temperature gradient,employing a variational method.Finally,on the basis of the optimization criterion,we carried out numerical simulations,with the results showing remarkable optimization effects.When irradiation,the ambient temperature and the wind speed are 800 W/m2,300 K and 3 m/s,respectively,the collector efficiency is enhanced by 8.8% through optimization,which is equivalent to a copper saving of 30%.We also applied the thickness distribution optimized for wind speed of 3 m/s in heat transfer analysis with different wind speed conditions,and the collector efficiency was remarkably better than that for an absorber with uniform thickness. 展开更多
关键词 太阳能集热器 耗散理论 热优化 平板型 厚度分布 应用 能源利用效率 集热效率
原文传递
Heat Transfer Optimization in Air Flat Plate Solar Collectors Integrated with Baffles 被引量:2
3
作者 Ramadhani Bakari 《Journal of Power and Energy Engineering》 2018年第1期70-84,共15页
This paper presents an experimental analysis for comparisons of conventional flat plate solar collectors and collectors integrated with different numbers of baffles. Heat transfer between absorber plate and drying flu... This paper presents an experimental analysis for comparisons of conventional flat plate solar collectors and collectors integrated with different numbers of baffles. Heat transfer between absorber plate and drying fluid (air) has been one of the major challenges in the design and operations of the indirect solar dryer systems. In this experiment, efficiency of air flat plate solar collector integrated with 2, 3, 4 and 8 baffles was studied and compared with the ordinary collector. The results showed that integrating solar collector with baffles significantly increased the efficiency of the system. It was noted that collector with 2, 3, 4 and 8 baffles had a mean efficiency of 29.2%, 31.3%, 33.1% and 33.7% respectively while with no baffles was 28.9%. The analysis showed that when there were less than four baffles in the collector, heat transfer was dominant over pressure drop and hence high efficiency. However, when the number of baffles exceeded four, the effect associated with an increase in pressure drop highly observed compared to heat transfer coefficient, thus resulted to insignificant increase in efficiency. Therefore, the optimum number of four baffles was commended for the designed model for optimum efficiency. 展开更多
关键词 solar collector solar DRYER SUN DRYING collector Efficiency Heat TRANSFER
下载PDF
Thermal performance of integration of solar collectors and building envelopes
4
作者 于国清 龚小辉 曹双华 《Journal of Central South University》 SCIE EI CAS 2009年第S1期255-258,共4页
The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studie... The integration of building with solar collector was studied. The theoretical model of integration of building envelopes and flat plate solar collectors was set up and the thermal performance of integration was studied in winter and summer,and compared to envelopes without solar collectors. The results show that the solar collection efficiency is raised in the integration of building envelopes and solar collectors with the air layer doors closed. This is true whether in winter or summer. The increment is higher as the inlet water temperature increases or the ambient temperature is low. In winter,the heat loss is significantly reduced through integration of the building envelopes and solar collectors with the closed air layer doors. The integration with the open air layer door is worse than that without collectors. In summer,the heat gains of the integration of envelopes and solar collectors are more obviously reduced than envelopes without collectors,the integration with the open air layer door is a little better than the closed one,but the difference is very small. 展开更多
关键词 solar collector building ENVELOPES solar COLLECTION efficiency heat TRANSFER INTEGRATION
下载PDF
Proposal of a Solar Thermal Power Plant at Low Temperature Using Solar Thermal Collectors
5
作者 Patrick Lindecker 《Energy and Power Engineering》 CAS 2022年第8期343-386,共44页
To this day, only two types of solar power plants have been proposed and built: high temperature thermal solar one and photovoltaic one. It is here proposed a new type of solar thermal plant using glass-top flat surfa... To this day, only two types of solar power plants have been proposed and built: high temperature thermal solar one and photovoltaic one. It is here proposed a new type of solar thermal plant using glass-top flat surface solar collectors, so working at low temperature (i.e., below 100°C). This power plant is aimed at warm countries, i.e., the ones mainly located between -40° and 40° latitude, having available space along their coast. This land based plant, to install on the seashore, is technologically similar to the one used for OTEC (Ocean Thermal Energy Conversion). This plant, apart from supplying electricity with a much better thermodynamic efficiency than OTEC plants, has the main advantage of providing desalinated water for drinking and irrigation. This plant is designed to generate electricity (and desalinated water) night and day and all year round, by means of hot water storage, with just a variation of the power delivered depending on the season. 展开更多
关键词 Power Plant solar Thermal solar Energy Renewable Energy Low Temperature solar collectors Electric Power Generation Desalinated Water
下载PDF
Optimum Design of Tilt Angle and Horizontal Direction of Solar Collectors under Obstacle’s Shadow for Building Applications
6
作者 Shaoning Wang Bo Hong 《Journal of Building Construction and Planning Research》 2015年第2期60-67,共8页
Solar collectors can provide clean, renewable, and domestic energy. The tilt angle and horizontal direction of solar collectors significantly affect its efficiency. There are many good methods to search the optimum ti... Solar collectors can provide clean, renewable, and domestic energy. The tilt angle and horizontal direction of solar collectors significantly affect its efficiency. There are many good methods to search the optimum tilt angle and horizontal direction to realize the maximum total radiation on the solar collector within a particular day or a specific period. However, it is hard to realize it when solar collectors are placed under obstacle’s shadows;especially when some obstacles, such as trees, have irregular shapes. This paper presents algorithms to achieve the best tilt angle and horizontal direction for solar collector’s performance under the free-form surfaces 3D obstacle’s shadow. The solution process is composed of 4 steps. First, it creates a 3D scene, in which a unique color is given to the solar collector. Second, it employs orthographic projection from the point of view to get an image of the scene. Third, the number of pixels is used to represent the efficiency of the solar collector by counting the pixels of the unique color. Fourth, the efficiency of solar collector in each direction in a period of time is calculated with many images to further select the best direction. 展开更多
关键词 solar collector TILT Angle HORIZONTAL Direction solar Radiation OPTIMUM Design Orthographic Projection
下载PDF
Energy and Cost Analysis of Processing Flat Plate Solar Collectors
7
作者 Mamdouh El Haj Assad Ali Khosravi +2 位作者 Mohammad AlShabi Bassam Khuwaileh Abdul-Kadir Hamid 《Energy Engineering》 EI 2021年第3期447-458,共12页
In this work,a life cycle analysis is accomplished for flat plate solar collectors.The purpose of this investigation is to predict the energy consumption during the manufacturing processes that results in carbon dioxi... In this work,a life cycle analysis is accomplished for flat plate solar collectors.The purpose of this investigation is to predict the energy consumption during the manufacturing processes that results in carbon dioxide emissions.Energy consumption and system efficiency enhancement will be studied and predicted.CES EduPack software is used to perform the analysis of the currently commercial system,and the suggested changes are implemented to increase the efficiency and make the comparison.Even though cost analysis is done,the priority of selection is given to the most energy conserving and environmentally friendly alternative.However,if the compared alternatives result in the same energy consumption and CO_(2)emissions,the cost analysis would be a better approach.It can be stated that flat plate solar collectors are sustainable and renewable energy systems that do not produce CO_(2)emissions during their active usage,but the manufacturing processes they undergo during the design contribute to the greenhouse gasses emission. 展开更多
关键词 Life cycle solar collector renewable energy solar thermal CO_(2)emission economic analysis
下载PDF
Solar Thermal Systems Performances versus Flat Plate Solar Collectors Connected in Series
8
作者 Khaled Zelzouli Amenallah Guizani +1 位作者 Ramzi Sebai Chakib Kerkeni 《Engineering(科研)》 2012年第12期881-893,共13页
This paper shows the modeling of a solar collective heating system in order to predict the system performances. Two systems are proposed: 1) the first, Solar Direct Hot Water, which is composed of flat plate collector... This paper shows the modeling of a solar collective heating system in order to predict the system performances. Two systems are proposed: 1) the first, Solar Direct Hot Water, which is composed of flat plate collectors and thermal storage tank, 2) the second, a Solar Indirect Hot Water in which we added an external heat exchanger of constant effectiveness to the first system. The mass flow rate by a collector is fixed to 0.04 Kg·s–1 and the total number of collectors is adjusted to 60. For the first system, the maximum average water temperature within the tank in a typical day in summer and annual performances are calculated by varying the number of collectors connected in series. For the second, this paper shows the detailed analysis of water temperature within the storage and annual performances by varying the mass flow rate on the cold side of the heat exchanger and the number of collectors in series on the hot side. It is shown that the stratification within the storage is strongly influenced by mass flow rate and the connections between collectors. It is also demonstrated that the number of collectors that can be connected in series is limited. The optimization of the mass flow rate on cold side of the heat exchanger is seen to be an important factor for the energy saving. 展开更多
关键词 Thermal Energy FLAT Plate collectors STRATIFICATION solar HEATING Systems
下载PDF
Ponceau 2R Doped Poly (ST/MMA) as Fluorescent Solar Collectors and Evaluation Effect of Matrix on Their Field Performance
9
作者 S. M. Reda Asla A. Al-Zahrani 《Open Journal of Energy Efficiency》 2012年第3期62-74,共13页
Luminescent solar concentrators (LSCs) with styrene (ST) and methylmethacrylate (MMA) of different percentage as the matrix were prepared by a casting method using ponceau 2R. DSC has been used to compare the thermal ... Luminescent solar concentrators (LSCs) with styrene (ST) and methylmethacrylate (MMA) of different percentage as the matrix were prepared by a casting method using ponceau 2R. DSC has been used to compare the thermal stability of the different LSCs. FTIR spectroscopy shows that appearance of -N=N- for ponceau 2R in all ST/MMA matrixes indicating that the highest stability of this kind of dye in these matrixes. The values of the optical band gap (Eg) have been obtained from direct allowed transition before and after the samples have been exposed to sunlight for 9 weeks. Photodegradation studies revealed that the more photostable dye doped in PMMA matrix than in other matrixes. The results showed that the homo PMMA/ponceau 2R system has the highest fluorescence quantum yield (Qf). Therefore this sample can be selected for field performance of fluorescent solar collectors. The photovoltaic cell coupled with homo PMMA/2R LSC shows a maximum efficiency, 2% compared to the normal one. 展开更多
关键词 LUMINESCENT solar collectors Ponceau 2R POLYMETHYLMETHACRYLATE POLYSTYRENE PHOTODEGRADATION Fluorescence Quantum Yield
下载PDF
Developments of solar collectors in China
10
作者 Yin Zhiqiang 《Engineering Sciences》 EI 2009年第2期80-85,共6页
China has abundant solar energy resource. Solar thermal collectors, particularly all-glass evacuated tubular collectors, have been studied and developed for 30 years, and solar thermal industry has developed rapidly f... China has abundant solar energy resource. Solar thermal collectors, particularly all-glass evacuated tubular collectors, have been studied and developed for 30 years, and solar thermal industry has developed rapidly for 15 years. There are various solar thermal systems, with an operation area of around 108 million m2 in 2007. These systems mainly provide domestic hot water, but some other applications are under extensive study and development as well. 展开更多
关键词 太阳能资源 太阳热能 真空管式 产业发展 生活热水 应用程序 收集器 热系统
下载PDF
Fabrication of Multilayer Optical interference Filter as Colored Glazed Buildings Fa(;ades for Thermal Solar Collectors Using MgF2/SiO2
11
作者 Abdul- Hussain Kh. Elttayef Zainab I. Al-Assadi 《Journal of Physical Science and Application》 2016年第1期49-55,共7页
关键词 太阳能集热器 干涉滤光片 建筑立面 光学模型 MGF2 二氧化硅 设计 射频磁控溅射技术
下载PDF
Solar Collectors of Buildings Facade Based on Aluminum Heat Pipes with Colored Coating
12
作者 Sergii Khaimasov Boris Rassamakin +1 位作者 Rostyslav Musiy Andrii Rassamakin 《Journal of Civil Engineering and Architecture》 2013年第4期403-408,共6页
关键词 太阳能集热器 建筑物 铝合金 彩色涂层 热管 建筑外墙装饰 模块开发 阳极氧化处理
下载PDF
Thermal performance of solar air collector with slit-like perforations
13
作者 李宪莉 由世俊 +1 位作者 张欢 尤占平 《Journal of Central South University》 SCIE EI CAS 2009年第S1期145-149,共5页
To offer a potentially low-cost and high-efficiency option for once-through applications,the unglazed transpired solar collector was studied. The semi-empirical correlation of overall heat exchange effectivenessε for... To offer a potentially low-cost and high-efficiency option for once-through applications,the unglazed transpired solar collector was studied. The semi-empirical correlation of overall heat exchange effectivenessε for UTC with circular holes was proposed to verify whether it being fit for this kind of absorber with slit-like perforations. The results show that in certain parameters,the predicted values of ε are very close to measured values,and the root mean square difference in betweens about 0.10,so the modle is suitable. Based on experimental results,this kind of absorber is proved to be feasible,with highest value of ε,up to 0.81. In addition,with the increase of γ,overall heat exchange effectiveness ε will decrease,i.e.,the value of ε will decrease with the increase of suction velocity vs or the decrease of wind velocity uw. However,the actual value of solar radiation intensity G and ambient temperature T∞ have little influence on ε. 展开更多
关键词 unglazed transpired solar collector overall heat EXCHANGE EFFECTIVENESS slit-like PERFORATIONS
下载PDF
Multi-factor Effects on Layout of Solar Collector
14
作者 SHI Hong MA Suning +1 位作者 GAO Zhigang GENG Shanshan 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第3期500-509,共10页
Considering the influencing factors of the layout of solar collectors such as the tilt angles,azimuth angles,spacing between collectors and the number of collector rows,a mathematical model of the collected energy of ... Considering the influencing factors of the layout of solar collectors such as the tilt angles,azimuth angles,spacing between collectors and the number of collector rows,a mathematical model of the collected energy of the solar collector with limited area on the horizontal plane is established.Two different optimized models including the cost benefit model and the minimum annual auxiliary heating energy model are conducted in this paper.The results show that,the collected energy in a year could increase with the increase of the number of collector rows.And the collected solar radiation in a year increases firstly and then decreases with the increase of the collector tilt angles.Furthermore,the collected solar radiation in a year increases firstly and then decreases with the continuous increase of the azimuth angles from -90° to 90°.Taking Nanjing city of China as an example,based on the optimized objective of maximum benefit,the optimal layout of the solar collector array in the area of 200 m2 should include:the number of collector rows is 8,the tilt angle is 40° and the azimuth angle is 0°.Meanwhile,the optimal methods for the optimized objective of minimum annual auxiliary heating energy should include:the number of collector rows is 9,the tilt angle is 50°,and the azimuth angle is 0°. 展开更多
关键词 solar collectors layout ECONOMIC analysis ANNUAL AUXILIARY HEATING RELATIVE SHADOW area
下载PDF
Solar Desalination with Latent Heat Storage Materials and Solar Collector 被引量:1
15
作者 Gowtham Mohan Hari Narayanan Soundararajan 《Journal of Mechanics Engineering and Automation》 2011年第2期126-134,共9页
关键词 太阳能集热器 海水淡化 储能材料 潜热 储存方法 空气加热器 热储存 接触面积
下载PDF
Experimentation of a Plane Solar Integrated Collector Storage Water Heater
16
作者 Romdhane Ben Slama 《Energy and Power Engineering》 2012年第2期67-76,共10页
In order to popularize the use of the solar-water heaters, especially in the residential and tertiary sectors with the third world, it appears to be necessary to reduce their cost while improving their performances. I... In order to popularize the use of the solar-water heaters, especially in the residential and tertiary sectors with the third world, it appears to be necessary to reduce their cost while improving their performances. It is the object of this integrated storage collector thus created and tested in the south of Tunisia. It is simply made up of a tank playing the double part of solar absorber and storage tank of warm water, of a glazing to profit from the greenhouse effect and of an insulating case. Its measured energy performances, by the method of input-output proves its effectiveness to produce hot water, in spite of its simplicity of manufacture, usage and maintenance. Indeed a temperature of water exceeding 70?C is reached towards the afternoon True Solar Time, and for an efficiency of 7%. Thus, this type of collector with integrated storage is entirely satisfactory and could be available to larger mass. 展开更多
关键词 HEATING of Water solar Energy STORAGE collector Tests
下载PDF
Arrangement of Multirow Solar Collector Array on Limited Roof Width
17
作者 PU Shaoxuan XIA Chaofeng 《Journal of Northeast Agricultural University(English Edition)》 CAS 2010年第4期76-82,共7页
At the limited roof north-south (N-S) width of a building, for the array with multirow collectors based on no shading at winter solstice noon and sloped at latitude, this paper studied the shading and the radiant en... At the limited roof north-south (N-S) width of a building, for the array with multirow collectors based on no shading at winter solstice noon and sloped at latitude, this paper studied the shading and the radiant energy striking on solar collector array. Based on Kunming solar radiation data, the annual and monthly solar radiant energy striking on multi-array collectors was analyzed and estimated, from no shading to partial shading by adding 1-3 collector row, at the slopes of 10°, 15°, 20°, 25°, 30°, 35° and 40°, respectively. The results showed that properly increasing the row number by reducing the slope of collectors was reasonable in order to get more annual radiant energy. Adding 1 row at 10° of slope was economical for Kunming, based on the 5-row array at 25°. And adding collector row by 20% at 10° of slope could increase the radiant energy striking on the array by 19%. 展开更多
关键词 limited roof width solar water heating system multirow collector array optimizing design
下载PDF
Enhanced efficiency in Concentrated Parabolic Solar Collector(CPSC) with a porous absorber tube filled with metal nanoparticle suspension
18
作者 Mohammad Hatami Jiafeng Geng Dengwei Jing 《Green Energy & Environment》 SCIE 2018年第2期129-137,共9页
In this study, effects of different nanoparticles and porosity of absorber tube on the performance of a Concentrating Parabolic Solar Collector(CPSC) were investigated. A section of porous-filled absorber tube was mod... In this study, effects of different nanoparticles and porosity of absorber tube on the performance of a Concentrating Parabolic Solar Collector(CPSC) were investigated. A section of porous-filled absorber tube was modeled as a semi-circular cavity under the solar radiation which is filled by nanofluids and the governing equations were solved by FlexPDE numerical software. The effect of four physical parameters, nanoparticles type, nanoparticles volume fraction(φ), Darcy number(Da) and Rayleigh number(Ra), on the Nusselt number(Nu) was discussed. It turns out that Cu nanoparticle is the most suitable one for such solar collectors, compared to the commonly used Fe_3O_4, Al_2O_3, TiO_2.With the increased addition of Cu nanoparticles all the parameters φ, Da and Ra shows a significant increase against the Nu, indicates the enhanced heat transfer in such cases. As a result, low concentration of Cu nanoparticle suspension combined with porous matrix was supposed to be beneficial for the performance enhancement of concentrating parabolic solar collector. 展开更多
关键词 Concentrating parabolic solar collector Porous absorber tube NANOFLUID Nusselt number Finite Element Method
下载PDF
Thermal Analysis and Experimental Validation of Parabolic Trough Collector for Solar Adsorption Refrigerator
19
作者 Mariella Mateo Rodolfo Echarri Inna Samsón 《Energy and Power Engineering》 2017年第11期687-702,共16页
This work presents an algorithm able to simulate the heating of a solar collector throughout the day. The discussed collector is part of a solar adsorption refrigerator, and is used to regenerate the activated carbon ... This work presents an algorithm able to simulate the heating of a solar collector throughout the day. The discussed collector is part of a solar adsorption refrigerator, and is used to regenerate the activated carbon contained inside a cylindrical recipient (absorber), which is located in the focal line of a parabolic trough concentrator. The developed algorithm takes into account all the transfer mechanisms when analyzing the heat transfers taking place between the collector’s components and the environment, as well as the transfer mechanisms towards the absorber’s interior. The temperature evolution for the collector’s elements is obtained, and the model is validated by comparing the experimentally measured surface temperature of the absorber with the one determined by the algorithm. The experimental data were gathered from similar collectors in two different scenarios: Santo Domingo (Dominican Republic) and Buenos Aires (Argentina). The model is satisfactorily validated with experimental data. 展开更多
关键词 Mathematical Model Heat Transfer PARABOLIC TROUGH collector solar ADSORPTION REFRIGERATOR
下载PDF
Theoretical and Experimental Study of a Double Air-Pass Solar Thermal Collector with an Insulating Rod of Millet
20
作者 Mame Mor Diarra Ndiaye Babacar Diallo +1 位作者 Said Abboudi Dorothé Azilinon 《Energy and Power Engineering》 2018年第3期106-119,共14页
In this article, we present the study of a double-pass air insulated by crushed millet stem mixed with gum arabic. The study is carried out based on mathematical models obtained by writing energy conservation laws in ... In this article, we present the study of a double-pass air insulated by crushed millet stem mixed with gum arabic. The study is carried out based on mathematical models obtained by writing energy conservation laws in the various components of the system, which made it possible to determine the evolution of the air temperature as a function of the length of the absorber and to make a comparison with the experimental results. After comparing the results obtained with those found in the literature, the influence of some physical and geometrical parameters on the performance of the solar thermal collector is presented. 展开更多
关键词 solar collector DOUBLE Air-Pass MILLET ROD Modeling Performance