This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power osci...This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.展开更多
With advances in modern agricultural parks,the rural energy structure has undergone profound change,leading to the emergence of an agricultural energy internet.This integrated system combines agricultural energy utili...With advances in modern agricultural parks,the rural energy structure has undergone profound change,leading to the emergence of an agricultural energy internet.This integrated system combines agricultural energy utilization,the information internet,and agricultural production.Accordingly,this study proposes a regulation flexibility assessment approach and optimal aggregation strategy of greenhouse loads(GHLs)for modern agricultural parks.First,taking into account the operational characteristics of typical GHLs,refined load demand models for lighting,humidification,and temperature-controlled loads are established.Secondly,the recursive least squares method-based parameter identification method is designed to accurately determine key GHL model parameters.Finally,based on the regulation flexibility of quantitatively evaluated GHLs,GHLs are optimally aggregated into multiple flexible aggregators considering minimal operational cost and greenhouse environmental constraints.The results indicate that the proposed regulation flexibility assessment approach and optimal aggregation strategy of GHLs can alleviate the peak regulation pressure on power grids by flexibly shifting the load demands of GHLs.展开更多
In this paper, a non-isolated stacked bidirectional DC-DC converter with zero-voltage-switching(ZVS) is introduced for the high step-up/step-down conversion systems. The extremely narrow turn-on and/or turn-off duty c...In this paper, a non-isolated stacked bidirectional DC-DC converter with zero-voltage-switching(ZVS) is introduced for the high step-up/step-down conversion systems. The extremely narrow turn-on and/or turn-off duty cycle existing in the conventional bidirectional buck-boost converters can be extended due to the stacked module configuration for large voltage conversion ratio applications. Furthermore, the switch voltage stress is halved because of the series connection of half bridge modules. The PWM plus phase-shift control strategy is employed, where the duty cycle is adopted to regulate the voltages between the input and output sides and the phaseshift angle is applied to achieve the power flow regulation.This decoupled control scheme can not only realize seamless bidirectional transition operation, but also achieve adaptive voltage balance for the power switches. In addition, ZVS soft-switching operation for all active switches is realized to minimize the switching losses. Finally, a prototype of 1 kW operating at 100 kHz is built and tested to demonstrate the effectiveness of the proposed converter and the control strategy.展开更多
基金This work is supported by the National Key Research and Development Program of China under Project 2021YFB2601600。
文摘This paper develops a flexible power regulation and limitation strategy of voltage source inverters(VSIs)under unbalanced grid faults.When the classical power theory is used under unbalanced grid faults,the power oscillations and current distortions are inevitable.In the proposed strategy,the extended power theory is introduced to compute the power feedbacks together with the classical power theory.Based on the combination of the classical and extended power theory,the proposed strategy can achieve the sinusoidal current provision and the flexible regulation between three common targets,i.e.,constant active power,balanced current,and constant reactive power.Meanwhile,the proposed strategy is associated with a power limiter,which is capable to keep the currents under the pre-defined threshold and to compute the maximum apparent power for better utilization of the inverter capacity.With this power limiter,the rated inverter capacity is fully used for both the active and reactive power provisions under unbalanced grid faults.Using the proposed power regulation and limitation,the VSI can avoid overcurrent tripping and flexibly regulate its power under unbalanced grid faults.All the conclusions are verified by the real-time hardware-in-loop tests.
基金the Science and Technology Project of State Grid Corporation of China(No.1400-202224249A-1-1-ZN)the National Natural Science Foundation of China(No.52077075 and No.72271068)+2 种基金the Foundations of Shenzhen and Technology Committee(No.GJHZ20210705141811036 and No.GXWD20220811151845006)the Major Science and Technology Special Projects in Xinjiang Autonomous Region(No.2022A01007)the Fundamental Research Funds for the Central Universities(No.2023JC001).
文摘With advances in modern agricultural parks,the rural energy structure has undergone profound change,leading to the emergence of an agricultural energy internet.This integrated system combines agricultural energy utilization,the information internet,and agricultural production.Accordingly,this study proposes a regulation flexibility assessment approach and optimal aggregation strategy of greenhouse loads(GHLs)for modern agricultural parks.First,taking into account the operational characteristics of typical GHLs,refined load demand models for lighting,humidification,and temperature-controlled loads are established.Secondly,the recursive least squares method-based parameter identification method is designed to accurately determine key GHL model parameters.Finally,based on the regulation flexibility of quantitatively evaluated GHLs,GHLs are optimally aggregated into multiple flexible aggregators considering minimal operational cost and greenhouse environmental constraints.The results indicate that the proposed regulation flexibility assessment approach and optimal aggregation strategy of GHLs can alleviate the peak regulation pressure on power grids by flexibly shifting the load demands of GHLs.
基金supported by National Natural Science Foundation of China(No.51277195)
文摘In this paper, a non-isolated stacked bidirectional DC-DC converter with zero-voltage-switching(ZVS) is introduced for the high step-up/step-down conversion systems. The extremely narrow turn-on and/or turn-off duty cycle existing in the conventional bidirectional buck-boost converters can be extended due to the stacked module configuration for large voltage conversion ratio applications. Furthermore, the switch voltage stress is halved because of the series connection of half bridge modules. The PWM plus phase-shift control strategy is employed, where the duty cycle is adopted to regulate the voltages between the input and output sides and the phaseshift angle is applied to achieve the power flow regulation.This decoupled control scheme can not only realize seamless bidirectional transition operation, but also achieve adaptive voltage balance for the power switches. In addition, ZVS soft-switching operation for all active switches is realized to minimize the switching losses. Finally, a prototype of 1 kW operating at 100 kHz is built and tested to demonstrate the effectiveness of the proposed converter and the control strategy.