Flight simulator is an important device and a typical high performanceposition servo system used in the hardware-in-the-loop simulation of flight control system. Withoutusing the future desired output, zero phase erro...Flight simulator is an important device and a typical high performanceposition servo system used in the hardware-in-the-loop simulation of flight control system. Withoutusing the future desired output, zero phase error controller makes the overall system's frequencyresponse exhibit zero phase shift for all frequencies and a very small gain error at low frequencyrange can be achieved. A new algorithm to design the feed forward controller is presented, in orderto reduce the phase error, the design of proposed feed forward controller uses a modified plantmodel, which is a closed loop transfer function, through which the system tracking precisionperformance can be improved greatly. Real-time control results show the effectiveness of theproposed approach in flight simulator servo system.展开更多
To improve the robustness of high-precision servo systems, quantitative feedback theory (QFT) which aims to achieve a desired robust design over a specified region of plant uncertainty is proposed. The robust design...To improve the robustness of high-precision servo systems, quantitative feedback theory (QFT) which aims to achieve a desired robust design over a specified region of plant uncertainty is proposed. The robust design problem can be solved using QFT but it fails to guarantee a high precision tracking. This problem is solved by a robust digital QFT control scheme based on zero phase error (ZPE) feed forward compensation. This scheme consists of two parts: a QFT controller in the closed-loop system and a ZPE feed-forward compensator. Digital QFT controller is designed to overcome the uncertainties in the system. Digital ZPE feed forward controller is used to improve the tracking precision. Simulation and real-time examples for flight simulator servo system indicate that this control scheme can guarantee both high robust performance and high position tracking precision.展开更多
An innovative in-flight glass melting technology with a multi-phase AC arc plasma was developed to save energy and reduce emissions for the glass industry. The effect of the injection position on the in-flight melting...An innovative in-flight glass melting technology with a multi-phase AC arc plasma was developed to save energy and reduce emissions for the glass industry. The effect of the injection position on the in-flight melting behavior of granulated powders was investigated. Results show that the injection position has a strong effect on the melting behavior of alkali-free glass raw material. With the increase in injection distance, the vitrification, decomposition, and particle shrinkage of initial powders are improved. Longer injection distance causes much energy to transfer to particles due to a longer residence time of powder in the high temperature zone. The high vitrification and decomposition degrees indicate that the new in-flight melting technology with 12-phase AC arc can substantially reduce the melting and refining time for glass production.展开更多
Using the future desired input value, zero phase error controller enables the overall system's frequency response exhibit zero phase shift for all frequencies and a small gain error at low frequency range, and based ...Using the future desired input value, zero phase error controller enables the overall system's frequency response exhibit zero phase shift for all frequencies and a small gain error at low frequency range, and based on this, a new algorithm is presented to design the feedforward controller. However, zero phase error controller is only suitable for certain linear system. To reduce the tracking error and improve robustness, the design of the proposed feedforward controller uses a neural compensation based on diagonal recurrent neural network. Simulation and real-time control results for flight simulator servo system show the effectiveness of the proposed approach.展开更多
The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC ...The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.展开更多
In the non-inertial coordinates attached to the model wing, the two-dimensional unsteady flow field triggered by the motion of the model wing, similar to the flapping of the insect wings, was numerically simulated. On...In the non-inertial coordinates attached to the model wing, the two-dimensional unsteady flow field triggered by the motion of the model wing, similar to the flapping of the insect wings, was numerically simulated. One of the advantages of our method is that it has avoided the difficulty related to the moving-boundary problem. Another advantage is that the model has three degrees of freedom and can be used to simulate arbitrary motions of a two-dimensional wing in plane only if the motion is known. Such flexibility allows us to study how insects control their flying. Our results show that there are two parameters that are possibly utilized by insects to control their flight: the phase difference between the wing translation and rotation, and the lateral amplitude of flapping along the direction perpendicular to the average flapping plane.展开更多
The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ...The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.展开更多
SPAD阵列的规模不断扩大对读出电路(Read-out Integrated Circuit,ROIC)提出了更高的要求,时间数字转换器(Time to Digital Converter,TDC)是ROIC的核心电路,完成对光子飞行时间(Time-of-Flight,TOF)高精度量化。为避免大规模阵列中高...SPAD阵列的规模不断扩大对读出电路(Read-out Integrated Circuit,ROIC)提出了更高的要求,时间数字转换器(Time to Digital Converter,TDC)是ROIC的核心电路,完成对光子飞行时间(Time-of-Flight,TOF)高精度量化。为避免大规模阵列中高频时钟信号长距离走线而引起的串扰和噪声干扰,抑制初相误差引起的检测精度退化,设计了一种基于内置时钟的ROIC阵列电路,阵列像素间距均为100μm,内置于各像素内的门控环形振荡器(Gated Ring Oscillator,GRO)独立提供像素TDC所需的高频分相时钟信号,各像素GRO均由像素外置锁相环(Phase Locked Loop,PLL)产生的压控信号控制。由于采用一种基于事件驱动的检测策略,只量化光子事件有效触发的TOF,有效降低了系统功耗。该芯片采用TSMC 0.18μm 1.8 V标准CMOS工艺制造,测试结果表明:TDC的时间分辨率和量程分别为102 ps和100 ns,微分非线性DNL低于0.8 LSB,积分非线性INL低于1.3 LSB,系统功耗小于59.3 mW。展开更多
Aristolochic acid (AA) is a known nephrotoxin and potential carcinogen, which can form covalent DNA adducts after metabolic activation in vivo and in vitro. A simple method for preparation and characterization of ar...Aristolochic acid (AA) is a known nephrotoxin and potential carcinogen, which can form covalent DNA adducts after metabolic activation in vivo and in vitro. A simple method for preparation and characterization of aristolochic acid-DNA adducts was developed. Four AA-adducts were synthesized by a direct reaction of AAI/AAII with 2′-deoxynucleosides. The reaction mixture was first cleaned-up and pre-concentrated using solid phase extraction (SPE), and further purified by a reversed-phase high performance liquid chromatography (HPLC). By the application of developed SPE procedure, matrices and byproducts in reaction mixture could be greatly reduced and adducts of high purity (more than 94% as indicated by HPLC) were obtained. The purified AA-DNA adducts were identified and characterized with liquid-electrospray ionization-quadrupole-time of flight-mass spectrometry (LC-ESI-Q-TOF-MS/MS) and LC-Diode array detector-fluorescence (LC-DAD-FL) analysis. This work provides a robust tool for possible large-scale preparation of AA-DNA adduct standards, which can promote the further studies on carcinogenic and mutagenic mechanism of aristolochic acids.展开更多
基于顶空固相微萃取(head space solid phase microextraction,HS-SPME)结合全二维气相色谱-飞行时间质谱(comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry,GC×GC-TOFMS)建立了一种准确定量...基于顶空固相微萃取(head space solid phase microextraction,HS-SPME)结合全二维气相色谱-飞行时间质谱(comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry,GC×GC-TOFMS)建立了一种准确定量白酒中氨基甲酸乙酯(ethyl carbamate,EC)的方法。实验对HS-SPME方法进行了优化,在酒精度12%vol、加NaCl 3 g、萃取温度70℃,萃取时间40 min的条件下,能够显著提高目标物的响应值。实验以D_(5)-氨基甲酸乙酯(D_(5)-EC)为内标,对不同浓度的样品溶液进行GC×GC-TOFMS定量分析。结果表明,EC在10~500μg/L范围内线性关系良好,回归系数(R^(2))>0.998,检出限为0.19μg/L,定量限为0.64μg/L,平均回收率为97.57%,精密度为8.66%。测定结果与国标方法相比无显著性差异(P>0.05)。该方法前处理简单,检测灵敏度更高,为白酒中EC自动化定量测定提供了新思路。展开更多
基金This project is supported by Aeronautics Foundation of China (No.00- E51022).
文摘Flight simulator is an important device and a typical high performanceposition servo system used in the hardware-in-the-loop simulation of flight control system. Withoutusing the future desired output, zero phase error controller makes the overall system's frequencyresponse exhibit zero phase shift for all frequencies and a very small gain error at low frequencyrange can be achieved. A new algorithm to design the feed forward controller is presented, in orderto reduce the phase error, the design of proposed feed forward controller uses a modified plantmodel, which is a closed loop transfer function, through which the system tracking precisionperformance can be improved greatly. Real-time control results show the effectiveness of theproposed approach in flight simulator servo system.
基金This project was supported by the Aeronautics Foundation of China (00E51022).
文摘To improve the robustness of high-precision servo systems, quantitative feedback theory (QFT) which aims to achieve a desired robust design over a specified region of plant uncertainty is proposed. The robust design problem can be solved using QFT but it fails to guarantee a high precision tracking. This problem is solved by a robust digital QFT control scheme based on zero phase error (ZPE) feed forward compensation. This scheme consists of two parts: a QFT controller in the closed-loop system and a ZPE feed-forward compensator. Digital QFT controller is designed to overcome the uncertainties in the system. Digital ZPE feed forward controller is used to improve the tracking precision. Simulation and real-time examples for flight simulator servo system indicate that this control scheme can guarantee both high robust performance and high position tracking precision.
基金supported by the New Energy and Industrial Technology Development Organization of Japan and the Scientific Research Foundation for the Returned Overseas Chinese Scholars,State Education Ministry of China
文摘An innovative in-flight glass melting technology with a multi-phase AC arc plasma was developed to save energy and reduce emissions for the glass industry. The effect of the injection position on the in-flight melting behavior of granulated powders was investigated. Results show that the injection position has a strong effect on the melting behavior of alkali-free glass raw material. With the increase in injection distance, the vitrification, decomposition, and particle shrinkage of initial powders are improved. Longer injection distance causes much energy to transfer to particles due to a longer residence time of powder in the high temperature zone. The high vitrification and decomposition degrees indicate that the new in-flight melting technology with 12-phase AC arc can substantially reduce the melting and refining time for glass production.
基金The project was supported by Aeronautics Foundation of China (00E51022).
文摘Using the future desired input value, zero phase error controller enables the overall system's frequency response exhibit zero phase shift for all frequencies and a small gain error at low frequency range, and based on this, a new algorithm is presented to design the feedforward controller. However, zero phase error controller is only suitable for certain linear system. To reduce the tracking error and improve robustness, the design of the proposed feedforward controller uses a neural compensation based on diagonal recurrent neural network. Simulation and real-time control results for flight simulator servo system show the effectiveness of the proposed approach.
基金the Medical Program of Scientific & Technical Foundation in Xiamen in 2008, No. 3502Z20084028
文摘The optimal velocity encoding of phase-contrast magnetic resonance angiography (PC MRA) in measuring cerebral blood flow volume (BFV) ranges from 60 to 80 cm/s. To verify the accuracy of two-dimensional (2D) PC MRA, the present study localized the region of interest at blood vessels of the neck using PC MRA based on three-dimensional time-of-flight sequences, and the velocity encoding was set to 80 cm/s. Results of the measurements showed that the error rate was 7.0±6.0% in the estimation of BFV in the internal carotid artery, the external carotid artery and the ipsilateral common carotid artery. There was no significant difference, and a significant correlation in BFV between internal carotid artery + external carotid artery and ipsilateral common carotid artery. In addition, the BFV of the common carotid artery was correlated with that of the ipsilateral internal carotid artery. The main error was attributed to the external carotid artery and its branches. Therefore, after selecting the appropriate scanning parameters and protocols, 2D PC MRA is more accurate in the determination of BFV in the carotid arteries.
文摘In the non-inertial coordinates attached to the model wing, the two-dimensional unsteady flow field triggered by the motion of the model wing, similar to the flapping of the insect wings, was numerically simulated. One of the advantages of our method is that it has avoided the difficulty related to the moving-boundary problem. Another advantage is that the model has three degrees of freedom and can be used to simulate arbitrary motions of a two-dimensional wing in plane only if the motion is known. Such flexibility allows us to study how insects control their flying. Our results show that there are two parameters that are possibly utilized by insects to control their flight: the phase difference between the wing translation and rotation, and the lateral amplitude of flapping along the direction perpendicular to the average flapping plane.
文摘The 13-MeV proton linac of the Compact Pulsed Hadron Source(CPHS) at Tsinghua University, China,is composed of a 50-keV electron cyclotron resonance proton source, a 3-MeV four-vane-type radio-frequency quadrupole(RFQ) accelerator, and a drift tube linac(DTL). Precise measurement of the beam energies at the exit of the RFQ and the DTL is critical for DTL commissioning. Two button-type beam position monitors(BPMs) installed downstream of the RFQ are used to perform the measurement using a time-of-flight method. The effects of several factors on phase measurement accuracy are analyzed. The phase measurement accuracy of the BPMs at CPHS is better than ± 1.03° at 325 MHz after corrections,corresponding to an energy measurement error of± 0.07%. The beam energy measured at the exit of the RFQ is 2.994 ± 0.0022 MeV,which is consistent with the design value.
基金supported by the National Basic Research Program (973) of China (No. 2007CB407305,2008CB417201)the National High Technology Research and Development Program (863) of China (No.2007AA06A407)the National Natural Science Foundation of China (No. 20737003, 20621703, 20805057)
文摘Aristolochic acid (AA) is a known nephrotoxin and potential carcinogen, which can form covalent DNA adducts after metabolic activation in vivo and in vitro. A simple method for preparation and characterization of aristolochic acid-DNA adducts was developed. Four AA-adducts were synthesized by a direct reaction of AAI/AAII with 2′-deoxynucleosides. The reaction mixture was first cleaned-up and pre-concentrated using solid phase extraction (SPE), and further purified by a reversed-phase high performance liquid chromatography (HPLC). By the application of developed SPE procedure, matrices and byproducts in reaction mixture could be greatly reduced and adducts of high purity (more than 94% as indicated by HPLC) were obtained. The purified AA-DNA adducts were identified and characterized with liquid-electrospray ionization-quadrupole-time of flight-mass spectrometry (LC-ESI-Q-TOF-MS/MS) and LC-Diode array detector-fluorescence (LC-DAD-FL) analysis. This work provides a robust tool for possible large-scale preparation of AA-DNA adduct standards, which can promote the further studies on carcinogenic and mutagenic mechanism of aristolochic acids.
文摘基于顶空固相微萃取(head space solid phase microextraction,HS-SPME)结合全二维气相色谱-飞行时间质谱(comprehensive two-dimensional gas chromatography-time-of-flight mass spectrometry,GC×GC-TOFMS)建立了一种准确定量白酒中氨基甲酸乙酯(ethyl carbamate,EC)的方法。实验对HS-SPME方法进行了优化,在酒精度12%vol、加NaCl 3 g、萃取温度70℃,萃取时间40 min的条件下,能够显著提高目标物的响应值。实验以D_(5)-氨基甲酸乙酯(D_(5)-EC)为内标,对不同浓度的样品溶液进行GC×GC-TOFMS定量分析。结果表明,EC在10~500μg/L范围内线性关系良好,回归系数(R^(2))>0.998,检出限为0.19μg/L,定量限为0.64μg/L,平均回收率为97.57%,精密度为8.66%。测定结果与国标方法相比无显著性差异(P>0.05)。该方法前处理简单,检测灵敏度更高,为白酒中EC自动化定量测定提供了新思路。