The present paper presents a device to test flow meters under an arbitrary pressure pulsation in a gas pipeline with a laminar flow containing frequency components up to 50 Hz, with the amplitude reaching hundreds of ...The present paper presents a device to test flow meters under an arbitrary pressure pulsation in a gas pipeline with a laminar flow containing frequency components up to 50 Hz, with the amplitude reaching hundreds of pascals. In order to reduce flow noise, the device has a strainer-like element connected to a pipeline under test and uses an open-loop control law based on the frequency response test. The control signal is calculated by adding the inputs to obtain each of the sinusoidal waves included in the original wave, which was decomposed by Fourier analysis. The validity of the developed method is demonstrated through the generation tests of superimposed pressure waves containing frequency components up to 50 Hz. Analysis of the relative uncertainty demonstrated the relative uncertainty to be less than 10% when the generated pressure is larger than 360 Pa.展开更多
New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in...New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in “Raskhod-RU” CAD system for computer aided design and calculation of differential pressure flow meters. “Raskhod-RU” CAD meets the requirements of new Standards implemented in CIS countries (GOST 8.586.1,2,3,4,5-2005) and provides accomplishment of the following tasks: verification of conditions (constraints) for application of the differential pressure method according to the requirements of new Standards;calculation of parameters of primary device, pipe straight lengths and flow meter in general according to the requirements of new Standards;calculation of uncertainty of results of fluid flow rate and volume measurement.展开更多
Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification perce...Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.展开更多
This study aimed to obtain the production profiles of oil-in-water flow under low flow rate and high water-cut conditions in oil wells.A combination production profile logging composed of an arc-type conductance senso...This study aimed to obtain the production profiles of oil-in-water flow under low flow rate and high water-cut conditions in oil wells.A combination production profile logging composed of an arc-type conductance sensor(ATCS)and a cross-correlation flow meter(CFM)with a center body is proposed and experimentally evaluated.The ATCS is designed for water holdup measurement,whereas the CFM with a center body is proposed to obtain the mixture velocity.Then,a drift-flux model based on flow patterns is established to predict the individual-phase superficial velocity of oil-in-water flows.Results show that the ATCS possesses high resolution in water holdup measurement and that flow pattern information can be deduced from its signal through nonlinear time series analysis.The CFM can enhance the correlation of upstream and downstream signals and simplify the relationship between the cross-correlation velocity and mixture velocity.On the basis of the drift-flux model,individual-phase superficial velocities can be predicted with high accuracy for different flow patterns.展开更多
The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied...The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.展开更多
An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic conv...An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic convergence of the traffic density to the desired one. Thecontrol scheme is applied to a freeway model, and simulation results confirm the efficacy of theproposed approach.展开更多
Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocesso...Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.展开更多
文摘The present paper presents a device to test flow meters under an arbitrary pressure pulsation in a gas pipeline with a laminar flow containing frequency components up to 50 Hz, with the amplitude reaching hundreds of pascals. In order to reduce flow noise, the device has a strainer-like element connected to a pipeline under test and uses an open-loop control law based on the frequency response test. The control signal is calculated by adding the inputs to obtain each of the sinusoidal waves included in the original wave, which was decomposed by Fourier analysis. The validity of the developed method is demonstrated through the generation tests of superimposed pressure waves containing frequency components up to 50 Hz. Analysis of the relative uncertainty demonstrated the relative uncertainty to be less than 10% when the generated pressure is larger than 360 Pa.
文摘New methodology of designing the differential pressure flow meters for fluid energy carriers is developed in order to provide minimum uncertainty of results of flow rate measurement. This methodology is implemented in “Raskhod-RU” CAD system for computer aided design and calculation of differential pressure flow meters. “Raskhod-RU” CAD meets the requirements of new Standards implemented in CIS countries (GOST 8.586.1,2,3,4,5-2005) and provides accomplishment of the following tasks: verification of conditions (constraints) for application of the differential pressure method according to the requirements of new Standards;calculation of parameters of primary device, pipe straight lengths and flow meter in general according to the requirements of new Standards;calculation of uncertainty of results of fluid flow rate and volume measurement.
基金Supported by the Youth Science Foundation of Heilongjiang(QC2010119,QC2010028)the Science and Technology Innovation Person with Ability Study Special Foundation Project of Harbin(2011RFQXN054)+1 种基金the Graduate Student Innovative Scientific Research Project of Heilongjiang(YJSCX2011-064JHL)Division of Soybean Machinery,CARS(nycytx-004)
文摘Vacuum precision seed metering is the key part of vacuum seed planter. Planting performance of planter is affected by vacuum and air flow which are important parameters for choosing fan. Effects of qualification percent and miss percent on air chamber vacuum 3, 4, 5 and 6 kPa were studied at different operating speeds. The results showed that operating performance of the seed metering was excellent when air chamber vacuum was 5 and 6 kPa, which air flow was 7.4-8.0 m3·s-1 and 8.0-8.8 m3·s-1 , respectively.
基金supported by the National Natural Science Foundation of China(Nos.51527805 and 11572220)
文摘This study aimed to obtain the production profiles of oil-in-water flow under low flow rate and high water-cut conditions in oil wells.A combination production profile logging composed of an arc-type conductance sensor(ATCS)and a cross-correlation flow meter(CFM)with a center body is proposed and experimentally evaluated.The ATCS is designed for water holdup measurement,whereas the CFM with a center body is proposed to obtain the mixture velocity.Then,a drift-flux model based on flow patterns is established to predict the individual-phase superficial velocity of oil-in-water flows.Results show that the ATCS possesses high resolution in water holdup measurement and that flow pattern information can be deduced from its signal through nonlinear time series analysis.The CFM can enhance the correlation of upstream and downstream signals and simplify the relationship between the cross-correlation velocity and mixture velocity.On the basis of the drift-flux model,individual-phase superficial velocities can be predicted with high accuracy for different flow patterns.
基金supported by the Industrial Infrastructure Program through The Korea Institute for Advancement of Technology(KIAT) Grant funded by the Korea government Ministry of Trade,Industry and Energy(Grant N0000502)
文摘The venturi meter has an advantage in its use,because it can measure flow without being much affected by the type of the measured fluid or flow conditions.Hence,it has excellent versatility and is being widely applied in many industries.The flow of a liquid containing air is a representative example of a multiphase flow and exhibits complex flow characteristics.In particular,the greater the gas volume fraction(GVF),the more inhomogeneous the flow becomes.As a result,using a venturi meter to measure the rate of a flow that has a high GVF generates an error.In this study,the cause of the error occurred in measuring the flow rate for the multiphase flow when using the venturi meter for analysis by CFD.To ensure the reliability of this study,the accuracy of the multiphase flow models for numerical analysis was verified through comparison between the calculated results of numerical analysis and the experimental data.As a result,the Grace model,which is a multiphase flow model established by an experiment with water and air,was confirmed to have the highest reliability.Finally,the characteristics of the internal flow Held about the multiphase flow analysis result generated by applying the Grace model were analyzed to find the cause of the uncertainty occurring when measuring the flow rate of the multiphase flow using the venturi meter.A phase separation phenomenon occurred due to a density difference of water and air inside the venturi,and flow inhomogeneity happened according to the flow velocity difference of each phase.It was confirmed that this flow inhomogeneity increased as the GVF increased due to the uncertainty of the flow measurement.
文摘An iterative learning control scheme is developed to the traffic densitycontrol in a macroscopic level freeway environment. With rigorous analysis, the proposed intelligentcontrol scheme guarantees the asymptotic convergence of the traffic density to the desired one. Thecontrol scheme is applied to a freeway model, and simulation results confirm the efficacy of theproposed approach.
文摘Flowing with the reform of the hot water heating method in China, heat meter will enter into households in the near future. A portable ultrasonic heat meter is designed in this paper. The meter uses chip microprocessor MSP430F437 as the data process core, and uses ultrasonic flow sensor to measure flow rate of the hot water, and capture input and output temperatures of the hot water using the thermal resistance sensor Ptl000, and then household energy consumption is calculated via temperature difference between input temperature and output temperature of the hot water multiplied by volume of hot water that is calculated though flow rate integration of hot water. In order to test the performance of the proposed heat meter, experiments is carried out. Both the temperature and flow measurement results satisfy the requirements of accuracy and the heat meter is effective in the heat measurement.