A filtering method of aero-engine load spectrum based on the rain flow counting is proposed in this paper.Firstly,the original load spectrum is counted through the rain flow method to get the peak and valley values.Th...A filtering method of aero-engine load spectrum based on the rain flow counting is proposed in this paper.Firstly,the original load spectrum is counted through the rain flow method to get the peak and valley values.Then,some data points in the original load spectrum are added between the peak and valley values.Finally,the filtering spectrum is obtained.The proposed method can reflect the path information of the original load spectrum.In addition,it can also eliminate the noise in the signal and improve the efficiency of signal processing,which is of practical significance for the research of aero-engine.展开更多
The fatigue of concrete structures will gradually appear after being subjected to alternating loads for a long time,and the accidents caused by fatigue failure of bridge structures also appear from time to time.Aiming...The fatigue of concrete structures will gradually appear after being subjected to alternating loads for a long time,and the accidents caused by fatigue failure of bridge structures also appear from time to time.Aiming at the problem of degradation of long-span continuous rigid frame bridges due to fatigue and environmental effects,this paper suggests a method to analyze the fatigue degradation mechanism of this type of bridge,which combines long-term in-site monitoring data collected by the health monitoring system(HMS)and fatigue theory.In the paper,the authors mainly carry out the research work in the following aspects:First of all,a long-span continuous rigid frame bridge installed with HMS is used as an example,and a large amount of health monitoring data have been acquired,which can provide efficient information for fatigue in terms of equivalent stress range and cumulative number of stress cycles;next,for calculating the cumulative fatigue damage of the bridge structure,fatigue stress spectrum got by rain flow counting method,S-N curves and damage criteria are used for fatigue damage analysis.Moreover,it was considered a linear accumulation damage through the Palmgren-Miner rule for the counting of stress cycles.The health monitoring data are adopted to obtain fatigue stress data and the rain flow counting method is used to count the amplitude varying fatigue stress.The proposed fatigue reliability approach in the paper can estimate the fatigue damage degree and its evolution law of bridge structures well,and also can help bridge engineers do the assessment of future service duration.展开更多
BACKGROUND Bivalirudin,a direct thrombin inhibitor,is used in anticoagulation therapies as a substitute for heparin,especially during cardiovascular procedures such as percutaneous coronary intervention.AIM To explore...BACKGROUND Bivalirudin,a direct thrombin inhibitor,is used in anticoagulation therapies as a substitute for heparin,especially during cardiovascular procedures such as percutaneous coronary intervention.AIM To explore the effect of bivalirudin on myocardial microcirculation following an intervention and its influence on adverse cardiac events in elderly patients with acute coronary syndrome(ACS).METHODS In total,165 patients diagnosed with acute myocardial at our hospital between June 2020 and June 2022 were enrolled in this study.From June 2020 to June 2022,elderly patients with ACS with complete data were selected and treated with interventional therapy.The study cohort was randomly divided into a study group(n=80,administered bivalirudin)and a control group(n=85,administered unfractionated heparin).Over a 6-mo follow-up period,differences in emergency processing times,including coronary intervention,cardiac function indicators,occurrence of cardiovascular events,and recurrence rates,were analyzed.RESULTS Significant differences were observed between the study cohorts,with the observation group showing shorter emergency process times across all stages:Emergency classification;diagnostic testing;implementation of coronary intervention;and conclusion of emergency treatment(P<0.05).Furthermore,the left ventricular ejection fraction in the observation group was significantly higher(P<0.05),and the creatine kinase-MB and New York Heart Association scores were CONCLUSION In elderly patients receiving interventional therapy for ACS,bivalirudin administration led to increased activated clotting time achievement rates,enhanced myocardial reperfusion,and reduced incidence of bleeding complications and adverse cardiac events.展开更多
Flow cytometry(FCM)is a powerful technique for single-bacteria analysis via simultaneous light-scattering and fluorescence measurements.By offering high-throughput,quantitative,and multiparameter analysis at the singl...Flow cytometry(FCM)is a powerful technique for single-bacteria analysis via simultaneous light-scattering and fluorescence measurements.By offering high-throughput,quantitative,and multiparameter analysis at the single-cell level,FCM has gained an increased popularity in microbiological research,food safety monitoring,water quality control,and clinical diagnosis.Here we will review the recent applications of flow cytometry in areas such as(1)total bacterial cell count,(2)bacterial viability analysis,(3)specific bacterial detection and identification,(4)characterization of physiological changes under environmental perturbations,and(5)biological function studies.Nevertheless,despite these widespread applications,challenges still remain for the detection of small sizes of bacteria and biochemical features that cannot be brightly stained via fluorescence.Recent improvement in FCM instrumentation will be discussed,and particularly the development of high sensitivity flow cytometry for advanced analysis of single bacterial cells will be highlighted.展开更多
As the outfield load spectrum is so complicated that it cannot be used directly for test study in laboratory.This paper presents a method to determine load spectrum for high and low cycle combined fatigue of turbine m...As the outfield load spectrum is so complicated that it cannot be used directly for test study in laboratory.This paper presents a method to determine load spectrum for high and low cycle combined fatigue of turbine mortise at elevated temperature through experimental and numerical method.First of all,the low cycle load spectrum with duration time is determined through cumulative damage rule.The rain flow counting method is applied to obtain main cycles and sub cycles,and then the stress cycle is converted into pulsation cycle(stress ratio=0)based on the S-N curve and the Goodman curve;Secondly,three groups of different amplitudes tests are established to determine the high cycle amplitude.Finally,another three groups of the high-low combined cycle fatigue(HLCCF)tests for turbine mortise of a certain type engine are carried out.The results show that the macro and micro failure modes are identical with outfield's,which verifies the accuracy of the conversion method.展开更多
Understanding the spatial and temporal dynamics of microbial communities in drinking water systems is vital to securing the microbial safety of drinking water.The objective of this study was to comprehensively charact...Understanding the spatial and temporal dynamics of microbial communities in drinking water systems is vital to securing the microbial safety of drinking water.The objective of this study was to comprehensively characterize the dynamics of microbial biomass and bacterial communities at each step of a full-scale drinking water treatment plant in Beijing,China.Both bulk water and biofilm samples on granular activated carbon(GAC) were collected over 9 months.The proportion of cultivable cells decreased during the treatment processes,and this proportion was higher in warm season than cool season,suggesting that treatment processes and water temperature probably had considerable impact on the R2 A cultivability of total bacteria.16 s rRNA gene based 454 pyrosequencing analysis of the bacterial community revealed that Proteobacteria predominated in all samples.The GAC biofilm harbored a distinct population with a much higher relative abundance of Acidobactena than water samples.Principle coordinate analysis and one-way analysis of similarity indicated that the dynamics of the microbial communities in bulk water and biofilm samples were better explained by the treatment processes rather than by sampling time,and distinctive changes of the microbial communities in water occurred after GAC filtration.Furthermore,20 distinct OTUs contributing most to the dissimilarity among samples of different sampling locations and 6 persistent OTUs present in the entire treatment process flow were identified.Overall,our findings demonstrate the significant effects that treatment processes have on the microbial biomass and community fluctuation and provide implications for further targeted investigation on particular bacteria populations.展开更多
基金This work was supported by the National Basic Research Program of China,National Nature Science Foundation of China(No.51675266)the Foundation Research Funds for the Center in NUAA(Nos.NJ20160038,NS2017011)Foundation of Graduate Innovation Center in NUAA(No.kfjj20170220)。
文摘A filtering method of aero-engine load spectrum based on the rain flow counting is proposed in this paper.Firstly,the original load spectrum is counted through the rain flow method to get the peak and valley values.Then,some data points in the original load spectrum are added between the peak and valley values.Finally,the filtering spectrum is obtained.The proposed method can reflect the path information of the original load spectrum.In addition,it can also eliminate the noise in the signal and improve the efficiency of signal processing,which is of practical significance for the research of aero-engine.
文摘The fatigue of concrete structures will gradually appear after being subjected to alternating loads for a long time,and the accidents caused by fatigue failure of bridge structures also appear from time to time.Aiming at the problem of degradation of long-span continuous rigid frame bridges due to fatigue and environmental effects,this paper suggests a method to analyze the fatigue degradation mechanism of this type of bridge,which combines long-term in-site monitoring data collected by the health monitoring system(HMS)and fatigue theory.In the paper,the authors mainly carry out the research work in the following aspects:First of all,a long-span continuous rigid frame bridge installed with HMS is used as an example,and a large amount of health monitoring data have been acquired,which can provide efficient information for fatigue in terms of equivalent stress range and cumulative number of stress cycles;next,for calculating the cumulative fatigue damage of the bridge structure,fatigue stress spectrum got by rain flow counting method,S-N curves and damage criteria are used for fatigue damage analysis.Moreover,it was considered a linear accumulation damage through the Palmgren-Miner rule for the counting of stress cycles.The health monitoring data are adopted to obtain fatigue stress data and the rain flow counting method is used to count the amplitude varying fatigue stress.The proposed fatigue reliability approach in the paper can estimate the fatigue damage degree and its evolution law of bridge structures well,and also can help bridge engineers do the assessment of future service duration.
文摘BACKGROUND Bivalirudin,a direct thrombin inhibitor,is used in anticoagulation therapies as a substitute for heparin,especially during cardiovascular procedures such as percutaneous coronary intervention.AIM To explore the effect of bivalirudin on myocardial microcirculation following an intervention and its influence on adverse cardiac events in elderly patients with acute coronary syndrome(ACS).METHODS In total,165 patients diagnosed with acute myocardial at our hospital between June 2020 and June 2022 were enrolled in this study.From June 2020 to June 2022,elderly patients with ACS with complete data were selected and treated with interventional therapy.The study cohort was randomly divided into a study group(n=80,administered bivalirudin)and a control group(n=85,administered unfractionated heparin).Over a 6-mo follow-up period,differences in emergency processing times,including coronary intervention,cardiac function indicators,occurrence of cardiovascular events,and recurrence rates,were analyzed.RESULTS Significant differences were observed between the study cohorts,with the observation group showing shorter emergency process times across all stages:Emergency classification;diagnostic testing;implementation of coronary intervention;and conclusion of emergency treatment(P<0.05).Furthermore,the left ventricular ejection fraction in the observation group was significantly higher(P<0.05),and the creatine kinase-MB and New York Heart Association scores were CONCLUSION In elderly patients receiving interventional therapy for ACS,bivalirudin administration led to increased activated clotting time achievement rates,enhanced myocardial reperfusion,and reduced incidence of bleeding complications and adverse cardiac events.
基金the National Key Basic Research Program of China(2013CB933703)the National Natural Science Foundation of China(91313302,21105082,21225523,21472158,21027010,21521004)the Program for Changjiang Scholars and Innovative Research Team in University(IRT13036)
文摘Flow cytometry(FCM)is a powerful technique for single-bacteria analysis via simultaneous light-scattering and fluorescence measurements.By offering high-throughput,quantitative,and multiparameter analysis at the single-cell level,FCM has gained an increased popularity in microbiological research,food safety monitoring,water quality control,and clinical diagnosis.Here we will review the recent applications of flow cytometry in areas such as(1)total bacterial cell count,(2)bacterial viability analysis,(3)specific bacterial detection and identification,(4)characterization of physiological changes under environmental perturbations,and(5)biological function studies.Nevertheless,despite these widespread applications,challenges still remain for the detection of small sizes of bacteria and biochemical features that cannot be brightly stained via fluorescence.Recent improvement in FCM instrumentation will be discussed,and particularly the development of high sensitivity flow cytometry for advanced analysis of single bacterial cells will be highlighted.
基金This work is supported by National Natural Science Foundation of China(51305012)Doctoral Fund of Ministry of Education of China(20111102120011)National Natural Science Foundation of China(51375031).The writers are grateful。
文摘As the outfield load spectrum is so complicated that it cannot be used directly for test study in laboratory.This paper presents a method to determine load spectrum for high and low cycle combined fatigue of turbine mortise at elevated temperature through experimental and numerical method.First of all,the low cycle load spectrum with duration time is determined through cumulative damage rule.The rain flow counting method is applied to obtain main cycles and sub cycles,and then the stress cycle is converted into pulsation cycle(stress ratio=0)based on the S-N curve and the Goodman curve;Secondly,three groups of different amplitudes tests are established to determine the high cycle amplitude.Finally,another three groups of the high-low combined cycle fatigue(HLCCF)tests for turbine mortise of a certain type engine are carried out.The results show that the macro and micro failure modes are identical with outfield's,which verifies the accuracy of the conversion method.
基金supported by the China Major Science and Technology Program for Water Pollution Control and Treatment(No.2012ZX07404-002)the Special Fund of State Key Joint Laboratory of Environment Simulation and Pollution Control(No.14K09ESPCT)
文摘Understanding the spatial and temporal dynamics of microbial communities in drinking water systems is vital to securing the microbial safety of drinking water.The objective of this study was to comprehensively characterize the dynamics of microbial biomass and bacterial communities at each step of a full-scale drinking water treatment plant in Beijing,China.Both bulk water and biofilm samples on granular activated carbon(GAC) were collected over 9 months.The proportion of cultivable cells decreased during the treatment processes,and this proportion was higher in warm season than cool season,suggesting that treatment processes and water temperature probably had considerable impact on the R2 A cultivability of total bacteria.16 s rRNA gene based 454 pyrosequencing analysis of the bacterial community revealed that Proteobacteria predominated in all samples.The GAC biofilm harbored a distinct population with a much higher relative abundance of Acidobactena than water samples.Principle coordinate analysis and one-way analysis of similarity indicated that the dynamics of the microbial communities in bulk water and biofilm samples were better explained by the treatment processes rather than by sampling time,and distinctive changes of the microbial communities in water occurred after GAC filtration.Furthermore,20 distinct OTUs contributing most to the dissimilarity among samples of different sampling locations and 6 persistent OTUs present in the entire treatment process flow were identified.Overall,our findings demonstrate the significant effects that treatment processes have on the microbial biomass and community fluctuation and provide implications for further targeted investigation on particular bacteria populations.