Rheological Behaviour for Polymer Melts and Concentrated SolutionsPart Ⅱ: Material Function with Nagai Chain Constraints and Determination of Their Parameters from Flow Curves 被引量:3
1
作者 Mingshi SONG Sizhu WU and Xiuyun DU(Research Institute of Polymeric Materials, Beijing University of Chemical Technology, Beijing, 100029, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 1995年第2期141-152,共12页
An integral constitutive equation and a set of material functions for describing the strain history of polymer melts were formulated in terms of the Cauchy-Green and Finger tensors. A simple memory function and the de... An integral constitutive equation and a set of material functions for describing the strain history of polymer melts were formulated in terms of the Cauchy-Green and Finger tensors. A simple memory function and the dependence of ηo and τt on M3.4 were derived from the theory of non-linear viscoelasticity with constraints of entanglements for polymer melts and substituted into the Oldroye-Walters-Fredickson constitutive equation. An integral constitutive equation for polymer melts was consequently obtained. Some material functions of the constitutive equation related to certain 'test flow' are examined as follows : (1) simple steady shear flow; (2) steady elongation flow; (3) small-amplitude oscillatory shear flow; (4) stress growth upon the inception of steady shear elongation flow; (5) stress relaxation (modulus and compllance). These theoretical relations for simple steady shear flow were compared with experimental data from our laboratory and references for various polymer melts and concentrated solutions. A good agreement between the theory and experiment was achieved. 展开更多
关键词 LDPE Material Function with Nagai Chain Constraints and determination of Their Parameters from flow Curves Rheological Behaviour for Polymer Melts and Concentrated SolutionsPart flow GR
下载PDF
Determination of Slip Length in Couette Flow Based on an Analytical Simulation Incorporating Surface Interaction 被引量:1
2
作者 赵欣 魏超 苑士华 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第3期77-81,共5页
An analytical simulation based on a new model incorporating surface interaction is conducted to study the slip phenomenon in the Couette flow at different scales. The velocity profile is calculated by taking account o... An analytical simulation based on a new model incorporating surface interaction is conducted to study the slip phenomenon in the Couette flow at different scales. The velocity profile is calculated by taking account of the micro-force between molecules and macro-force from the viscous shearing effect, as they contribute to the achieve- ment of the slip length. The calculated results are compared with those obtained from the molecular dynamics simulation, showing an excellent agreement. Further, the effect of the shear rate on the slip is investigated. The results can well predict the fluid flow behaviors on a solid substrate, but has to be proved by experiment. 展开更多
关键词 MD determination of Slip Length in Couette flow Based on an Analytical Simulation Incorporating Surface Interaction
下载PDF
A Novel Flow Injection Chemiluminescence System for the Determination of Reserpine
3
作者 庄惠生 王琼娥 +1 位作者 魏巧华 吴言林 《Journal of Donghua University(English Edition)》 EI CAS 2004年第6期7-9,共3页
A novel flow injection cheminescence (FICL) system for the determination of reserpine is presented in this paper. It is based on the CL reaction of reserpine, IO - 4 and H 2O 2 in H 2SO 4 medium. The CL intensity was ... A novel flow injection cheminescence (FICL) system for the determination of reserpine is presented in this paper. It is based on the CL reaction of reserpine, IO - 4 and H 2O 2 in H 2SO 4 medium. The CL intensity was correlated with concentration of reserpine in the range of 1.0×10 -6~1.0×10 -4 g/mL with a detection limit of 1.35×10 -7 g/ mL. The relative standard deviation is 2.63% for 11 measurements of 2×10 -5 g/mL reserpine standard solution. The method has been applied to the determination of reserpine in pharmaceutical preparations and the results are in good agreement with that of the standard method. 展开更多
关键词 Reserpine flow INJECTION Chemiluminescence determination
下载PDF
Simultaneous Determination of Gold and Platinum by Double Artificial Neural Network Analysis with Flow-injection Chemiluminescence 被引量:1
4
作者 Ming Yang LIU Hai Tao ZHANG Jun Feng LI Shu Gui CHEN Hong Yan WANG 《Chinese Chemical Letters》 SCIE CAS CSCD 2006年第10期1343-1346,共4页
A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simula... A highly sensitive double artificial neural network (DANN) analysis with flow-injection chemiluminescence (FI-CL) has been developed to simultaneously determine the trace amounts of the gold and platinum in simulated mixed samples, without the boring process. 展开更多
关键词 Double artificial neural networks flow-INJECTION CHEMILUMINESCENCE simultaneous determination gold and platinum.
下载PDF
SELECTIVE SULFUR DIOXIDE DETERMINATION BY GAS DIFFUSION FLOW INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION
5
作者 Yong He BAO Qi Jun SONG Department of Chemistry,XingJiang University,Urumchi,830046 《Chinese Chemical Letters》 SCIE CAS CSCD 1991年第4期313-314,共2页
Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffu... Sulfur dioxide has been found to decrease the chemiluminescence of luminol-iodine system.A new determination method for sulfur dioxide in atmosphere is developed by applying this reaction to a flow injection gas diffusion separation system.This permits the determination of sulfur dioxide selectively and rapidly. 展开更多
关键词 flow SELECTIVE SULFUR DIOXIDE determination BY GAS DIFFUSION flow INJECTION ANALYSIS WITH CHEMILUMINESCENT DETECTION GAS
下载PDF
Flow-Injection Microcolumn on-Line Preconcentration for theDetermination of Chromium(Ⅵ) 被引量:1
6
作者 Ma Wanhong Cat Ruxiu Lin Zhixin(College of Chemistry, Wuhan University. Wuhan 430072, China) 《Wuhan University Journal of Natural Sciences》 CAS 1998年第4期464-468,共5页
A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast a... A rapid and sensitive on-line preconcentration method for spectrophotometric determination of chromium (VI) in nature water is described. Preconcentration and determination are based on (i) the quantitative and fast adsorption of chromium (VI) on the high surface area nanometer-size TiO2 (anatase) powders, which prepared by a sol-gel method from hydrolysis of TiCI4 and (ii) the quantitative and reproducible elution of Cr (VI) by 2. 0 mol. L-1 HCI. A mini-column system for preconcentration is developed, Cr(VI)on the mini-column is eluted and merged with a stream water and DPCB (1, 5-diphenylcarbazide ) as the chromogenic reagent. The Proposed system permits throughputs of 6 sample h--l (0. 001 μg mL-1 Cr(VI) ) or 20 sample h-1 (0. 1 μg mL-1Cr (VI) . The preconcentration factor is 55. The detection limit is 0. 8 ng·mL-1 Cr(VI). The reproducibility is satisfactory with a relative standard deviation of less than 3. 35% (0. Of μg'mL-1Cr (VI), n = 5). 展开更多
关键词 anometer-size TiO2 Cr (Ⅵ) determination on-line preconcentration flow-injection spectrophotometric detection
下载PDF
Determination of platelet antigens and antidodies by antigen capture ELISA and flow cyto metry immunoassay
7
《中国输血杂志》 CAS CSCD 2001年第S1期362-,共1页
关键词 ELISA determination of platelet antigens and antidodies by antigen capture ELISA and flow cyto metry immunoassay flow
下载PDF
Experimental Acoustic Determination of the Void Fraction in Two-Phase Flow in Horizontal Pipelines
8
作者 Fernando Augusto de Noronha Castro Pinto Thiago de Campos Negrelly Alexandre Silva de Lima 《Journal of Mechanics Engineering and Automation》 2014年第8期625-631,共7页
In multi-phase flows, the phases can flow and arranged in different spatial configurations in the pipe, which called flow patterns. This type of flow is found in the oil, chemical and nuclear industries. For example, ... In multi-phase flows, the phases can flow and arranged in different spatial configurations in the pipe, which called flow patterns. This type of flow is found in the oil, chemical and nuclear industries. For example, in the production and transport of oil and gas, the identification of the flow patterns are essential for answering those questions which are related to the economic return of the field, such as, measuring the volumetric flow, determining the pressure drop along the flow lines, production management and supervision. In offshore production, these factors are very important. This paper presents a new method for measuring the void fraction in horizontal pipelines, taking the air as gas in water-air two-phase flow. Through acoustic analysis of the frequency response of the pipe, the method gets the parameters to changes in runoff regime, in an experimental arrangement constructed on a small scale. The main advantages are the non-intrusive characteristic and easy to implement. The paper is composed of a qualitative experimental evaluation and transducers (microphone) which are used to analyze variations in the response accompanying variations in void and flow pattern changes. Changes are imposed and controlled by a two-phase flow experimental simulation rig, including a measurement cell constituted of an external casing that can isolate the measurement from the environmental background noise fitted with acoustic pressure transducers radially arranged, and the impact of a monitored excitation mechanism. The signals which captured by the microphones are processed and analyzed by checking their frequency contents changes according to the amount of air in the mixture. 展开更多
关键词 Experimental method two-phase flow determination of void fraction horizontal pipelines.
下载PDF
Simultaneous Biparametric Determination of Total Calcium and Potassium in Biological Fluids by Flow Injection Analysis──Use of Powell's Method in the System Optimization
9
《Chemical Research in Chinese Universities》 SCIE CAS CSCD 1994年第1期5-15,共11页
SimultaneousBiparametricDeterminationofTotalCalciumandPotassiuminBiologicalFluidsbyFlowInjectionAnalysis──Us... SimultaneousBiparametricDeterminationofTotalCalciumandPotassiuminBiologicalFluidsbyFlowInjectionAnalysis──UseofPowell'sMethod... 展开更多
关键词 flow-injection analysis Two-component determination Potassiumand calcium Blood serum Powell's optimization
下载PDF
Comparison of two different methods for determining flow direction in catchment hydrological modeling
10
作者 Guang-ju ZHAO Jun-feng GAO +1 位作者 Peng TIAN Kun TIAN 《Water Science and Engineering》 EI CAS 2009年第4期1-15,共15页
Digital elevation models (DEMs) are widely used to define the flow direction in distributed hydrological models for simulation of streamflow. In recent decades, numerous methods for flow direction determination have... Digital elevation models (DEMs) are widely used to define the flow direction in distributed hydrological models for simulation of streamflow. In recent decades, numerous methods for flow direction determination have been applied successfully to mountainous regions. Nevertheless, some problems still exist when those methods are used for flat or gently sloped areas The present study reviews the conventional methods of determining flow direction for such landscapes and analyzes the problems of these methods. Two different methods of determining flow direction are discussed and were applied to the Xitiaoxi Catchment, located in the Taihu Basin in southern China, which has both mountainous and flat terrain. Both the agree method and the shortest path method use drainage networks derived from a remote sensing image to determine the correct location of the stream. The results indicate that the agree method provides a better fit with the DEM for the hilly region than the shortest path method. For the flat region where the flow has been diverted and rerouted by land managers, both methods require observation of the drainage network to determine the flow direction. In order to clarify the applicability of the two methods, both are employed in catchment hydrological models conceptually based on the Xinanjiang model and implemented with PCRaster. The simulation results show that both methods can be successfully applied in hydrological modeling. There are no evident differences in the modeled discharge when using the two methods at different spatial scales. 展开更多
关键词 DEM flow direction determination agree method shortest path method hydrological modeling Taihu Basin
下载PDF
Hydralazine Hydrochloride:An Alternative Complexometric Reagent for Total Iron Spotometric Determination
11
作者 Arlan de Assis Gonsalves Cleonia Roberta Melo Araujo +2 位作者 Cristiane Xavier Galhardo Marilia Oliveira Fonseca Goulart Fabiane Caxico de Abreu 《American Journal of Analytical Chemistry》 2011年第7期776-782,共7页
An alternative spectrophotometric method has been developed for total iron determination using flow injection analysis (FIA). The procedure is based on the coordination reaction between hydralazine and Fe2+ ions, whic... An alternative spectrophotometric method has been developed for total iron determination using flow injection analysis (FIA). The procedure is based on the coordination reaction between hydralazine and Fe2+ ions, which results in the formation of a purple complex monitored at 538 nm. For determination of total iron, Fe3+ ions were reduced using ascorbic acid. Under optimized conditions, a linear calibration graph (0.1 - 6.0 ?g?ml–1;n = 6) was obtained. The method allows LOD (3? of blank/slope = 0.06 ?g?ml–1) and LOQ (10? of blank/slope = 0.22 ?g?ml–1). The RSD ((s/ ) × 100) for a mixed standard containing 0.60 ?g?ml–1 Fe2+ and Fe3+ was 0.10% (n = 10). Recoveries of spiked samples were 94.3% - 106.0%. The analytical frequency was 60 h–1. The effect of possible interferences has been studied. The procedure was successfully applied for analysis of environmental samples. The real samples results were comparable with those obtained by the official method considering a paired t-test and 95% of confidence level. 展开更多
关键词 HYDRALAZINE Total Iron determination SPECTROPHOTOMETRY flow Injection Analysis
下载PDF
加速老化的无铬鞣革中游离苯胺的FIA-UV法分析
12
作者 马玉洁 秦丹 单志华 《四川师范大学学报(自然科学版)》 CAS 2024年第5期650-655,共6页
采用流动注射分析-紫外光谱法(FIA-UV),基于苯胺与亚硝酸盐在酸性条件下发生的重氮化反应及其在碱性条件下的偶合显色反应,实现苯胺的有效检测.通过实验参数的优化,确定495 nm为最大吸收波长,建立了苯胺质量浓度在0.002~2.0 mg/L范围内... 采用流动注射分析-紫外光谱法(FIA-UV),基于苯胺与亚硝酸盐在酸性条件下发生的重氮化反应及其在碱性条件下的偶合显色反应,实现苯胺的有效检测.通过实验参数的优化,确定495 nm为最大吸收波长,建立了苯胺质量浓度在0.002~2.0 mg/L范围内与峰高具有良好线性关系的模型(R^(2)=0.9997),检出限为1.62μg/L,重复性(RSD)为0.71%.该方法在加速老化后皮革萃取液中的应用表现出97.8%~103.8%的加标回收率,相较国标法具有更优的抗干扰能力和更高的检测精度.成功建立的苯胺检测新方法,为无铬鞣革产品的质量控制及环境监测提供了重要的技术支持,有助于提高公共健康和环境保护水平. 展开更多
关键词 无铬鞣革 苯胺 流动注射 分光光度法 含量测定
下载PDF
被害人自我答责的理论诠释与本土建构——正当性、构成要件及具体适用规则
13
作者 王晓 李心蕊 《青海师范大学学报(社会科学版)》 2024年第5期72-80,共9页
被害人自我答责理论需要刑法教义学的进一步诠释。在正当性层面,自我决定是自我答责的根本依据,以主体为视角,自我答责分为行为人的自我答责与被害人的自我答责,在刑事责任领域表现为行为人刑事责任的归属及程度问题。被害人自我答责的... 被害人自我答责理论需要刑法教义学的进一步诠释。在正当性层面,自我决定是自我答责的根本依据,以主体为视角,自我答责分为行为人的自我答责与被害人的自我答责,在刑事责任领域表现为行为人刑事责任的归属及程度问题。被害人自我答责的构成要件包括行为人实施了法律不允许的危险行为、被害人具备风险认识能力及自由意志、被害人的危险接受行为四个方面。针对具体的适用规则,基于因果流程考察,以被害人对法益侵害结果自我答责为原则,分为阻却行为人的刑事责任和减轻行为人的刑事责任两种方式;以行为人的自我答责为例外,被害人危险接受行为具有社会相当性,或行为人支配因果流程时,行为人承担全部责任,以保障个人自治与国家干预的平衡。 展开更多
关键词 被害人自我答责 自我决定 危险接受 因果流程支配 社会相当性
下载PDF
流式细胞仪对甘蓝花粉倍性的测定
14
作者 杨鼎 李崇娟 +4 位作者 吕凤仙 和江明 兰梅 胡靖峰 徐学忠 《湖北农业科学》 2024年第4期78-81,117,共5页
利用流式细胞仪测定甘蓝(Brassica oleracea var.capitata)花粉的倍性,以甘蓝GL21028的花粉为材料,以叶片为对照,比较花粉2种处理方式、3种不同细胞裂解液、2种核酸染料的效果差异。通过B缓冲液处理后获取的花粉细胞可以直接染色,为最... 利用流式细胞仪测定甘蓝(Brassica oleracea var.capitata)花粉的倍性,以甘蓝GL21028的花粉为材料,以叶片为对照,比较花粉2种处理方式、3种不同细胞裂解液、2种核酸染料的效果差异。通过B缓冲液处理后获取的花粉细胞可以直接染色,为最简便处理方式;采用“Aru”buffer和Y 2种裂解液,染色剂DAPI,处理甘蓝叶片和花粉,通过流式细胞仪检测,样本细胞DNA成峰集中,细胞碎片很少;配制的Y裂解液能够适用甘蓝材料流式细胞仪的观察。甘蓝花粉通过B缓冲液处理后,可以直接作为流式细胞仪倍性鉴定的材料,不再需要其他处理,配制的Y裂解液可以得到较好的试验结果。 展开更多
关键词 甘蓝(Brassica oleracea var.capitata) 流式细胞仪 花粉 测定 倍性 裂解液
下载PDF
连续流动分析法测定磷酸铁中的磷 被引量:1
15
作者 桂素萍 孙丽丽 +1 位作者 张淑娟 毛红祥 《云南化工》 CAS 2024年第3期97-99,共3页
采用连续流动分析仪测定磷酸铁中的磷,并与HG/T 4701-2021中的重量法进行了比对,结果表明,磷质量浓度在0~200μg/mL范围内与峰高具有良好的线性关系,相关系数r=1.0000,加标回收率在99%~101%之间。分析结果与HG/T 4701-2021标准方法无显... 采用连续流动分析仪测定磷酸铁中的磷,并与HG/T 4701-2021中的重量法进行了比对,结果表明,磷质量浓度在0~200μg/mL范围内与峰高具有良好的线性关系,相关系数r=1.0000,加标回收率在99%~101%之间。分析结果与HG/T 4701-2021标准方法无显著性差异。方法具有操作简便、结果准确、试剂消耗量少等优点。 展开更多
关键词 连续流动分析仪 磷酸铁 测定
下载PDF
烟气流速与流量手工监测方法现状与探讨 被引量:1
16
作者 李小龙 李军状 +4 位作者 郑成强 周道斌 段玖祥 朱法华 魏晗 《化工进展》 EI CAS CSCD 北大核心 2024年第7期4032-4042,共11页
“双碳”背景下,随着国家对碳排放监测准确度要求的提高,作为参比方法的烟气流速与流量手工监测标准方法急需进一步完善。针对此情况,从烟道测量位置要求、测量点的布置及测量方法等方面,综述了当前国内外烟气流速与流量手工监测方法的... “双碳”背景下,随着国家对碳排放监测准确度要求的提高,作为参比方法的烟气流速与流量手工监测标准方法急需进一步完善。针对此情况,从烟道测量位置要求、测量点的布置及测量方法等方面,综述了当前国内外烟气流速与流量手工监测方法的现状,并在此基础上提出了我国监测方法面临的问题及完善方向。关于测量位置,各国标准均对测量位置与流动扰动的距离有具体要求,细节方面存在一定差异,与美国、欧洲和ISO标准相比,我国标准缺少对测量位置气流方向及流场均匀性检查验证的具体规定。关于测量点,美国标准中测量点数的确定方法与各国标准差别较大,我国标准则与欧洲和ISO标准相似,各国标准中测量点的布置均采用网格法。关于流速与流量测量方法,我国标准制定方面存在明显差距,尤其缺少如提高测量结果准确度的三维或二维皮托管法、降低测量误差的壁面调整系数测量法及评价结果准确度的针对性测量不确定度评定方法等。有鉴于此,我国有必要从多方面加快完善烟气流速与流量手工监测标准方法的制定。 展开更多
关键词 烟气流速与流量 手工监测 测量位置 测量点 测量方法
下载PDF
牛庄地区沙三中亚段重力流沉积储层预测技术与应用
17
作者 刘旭锋 李凤磊 +1 位作者 刘华 徐杰 《石油地球物理勘探》 EI CSCD 北大核心 2024年第6期1362-1377,共16页
断陷湖盆重力流沉积砂体相变快、规模相对较小、形成机制及分布规律复杂,决定了该类储层地震响应特征复杂。通过有针对性地分析现有三维地震资料品质,优选适合进行目标处理的地震数据体开展研究。利用沙四段油页岩地震响应特征、多井正... 断陷湖盆重力流沉积砂体相变快、规模相对较小、形成机制及分布规律复杂,决定了该类储层地震响应特征复杂。通过有针对性地分析现有三维地震资料品质,优选适合进行目标处理的地震数据体开展研究。利用沙四段油页岩地震响应特征、多井正负极性子波分别标定等手段,判断资料极性,为目标处理打下基础。针对牛庄油田沙三中亚段地球物理特征、浊积砂岩体发育特征,设计不同砂体组合的理论正演模型和实际砂体正演模型,确定合理的参数完成三参数小波高分辨率目标处理方法,效果显著。获得以下认识:(1)处理后地震数据体高频成分较老资料明显拓宽,且实现了复波分离,波组特征清楚,合成记录标定显示,处理后资料品质明显优于原纯波资料;(2)处理后资料波组连续性提高,能量关系清晰,有利于浊积砂体等的识别;(3)处理后资料利于标定,通过多井标定,建立精细构造模型与井约束模型完成地震反演,预测结果与实钻吻合度较高,在详细地层划分对比、地质研究基础上,采用地层切片技术,完成对沙三中亚段第5~第8砂层组主力含油砂岩体纵向发育、平面分布研究,确定砂体边界,为断陷湖盆重力流砂体储层精细刻画提供了新的思路。 展开更多
关键词 极性判断 三参数小波 重力流 复波分离 井约束模型反演
下载PDF
全自动流动注射分光光度法测定锰厂排放水中的总氮
18
作者 石金雨 董黎 +1 位作者 刘晓芳 黎国兰 《绵阳师范学院学报》 2024年第5期53-57,共5页
探讨了全自动流动注射分光光度法测定锰厂排放水质总氮含量的方法.在0~6.000 mg·L^(-1)浓度范围内呈线性关系,其回归方程为y=134.86x+116.7,相关系数R达到1.000 0,方法检出限为0.006 7 mg·L^(-1),加标回收率在98.6%~109%之间... 探讨了全自动流动注射分光光度法测定锰厂排放水质总氮含量的方法.在0~6.000 mg·L^(-1)浓度范围内呈线性关系,其回归方程为y=134.86x+116.7,相关系数R达到1.000 0,方法检出限为0.006 7 mg·L^(-1),加标回收率在98.6%~109%之间,实验结果表明线性关系良好,方法准确可靠.并采用全自动流动注射分光光度法和碱性过硫酸钾消解-紫外分光光度法对质控样品进行了对比测试,两种方法测定结果无显著差异,测定值均在标准值范围内.该法应用于电解锰厂排放废水水质总氮测定,具有操作简单、测试快速、准确度高、精密度好、检出限低的优点,能快速完成大批量样品测定. 展开更多
关键词 全自动流动注射 测定 总氮
下载PDF
Clinical and biological relevance of flow cytometric determination of P-glycoprotein expression in acute non-lymphocytic leukemia 被引量:1
19
作者 李建勇 夏学鸣 +3 位作者 华东 王玮 陈子兴 阮长耿 《Chinese Medical Journal》 SCIE CAS CSCD 1997年第12期21-24,共4页
This study was supported by grants from Science and Technology Committee of Jiangsu and Health Bureau of Jiangsu. Objective To evaluate the characteristics of P glycoprotein(P gp) expression of acute non lym... This study was supported by grants from Science and Technology Committee of Jiangsu and Health Bureau of Jiangsu. Objective To evaluate the characteristics of P glycoprotein(P gp) expression of acute non lymphocytic leukemia (ANLL) at different status and the prognostic and biological features in ANLL at diagnosis. Methods Monoclonal antibody UIC2 and indirect immunofluorescence assay by flow cytometry were used to determine P gp expression of 169 patients with ANLL, including 152 previously untreated, 7 refractory and 10 at remission. Results P gp was expressed in 28.9% of the previously untreated ANLL cases and P gp was lower than that in 71.4% of the refractory cases (P<0.05). No P gp expression was found in the patients at remission. For previously untreated ANLL, P gp was highly expressed in hybrid acute leukemia (66.7%) and acute monoblastic leukemia (47.4%). P gp expression was highly associated with surface markers [cluster of differentiation (CD) 34, CD7, CD14, CD42b and CD61] and unfavorable cytogenetic abnormalities. About 23% of P gp +ANLL obtained complete remission, which was significantly lower than that (76%) in P gp - cases. Conclusions P gp expression is higher in refractory ANLL cases than that in cases at diagnosis or at remission. P gp is an index of poor prognosis in adults with ANLL. P gp +ANLL cases have unique clinical and biological characteristics. 展开更多
关键词 Clinical and biological relevance of flow cytometric determination of P-glycoprotein expression in acute non-lymphocytic leukemia
原文传递
基于大流量止回阀实验系统的快速预测模型
20
作者 王江坤 赵晶 +3 位作者 查洒洒 王剑 曲洺剑 张俊飞 《机电工程》 CAS 北大核心 2024年第4期659-665,共7页
针对传感器在数据获取中的局限性和无法用于对实验系统进行全面的数据收集问题,对大流量止回阀实验系统的快速预测模型技术进行了研究,建立了实验系统的快速预测模型,进行了快速预测模型的结果分析。首先,搭建了实体模型,根据大流量止... 针对传感器在数据获取中的局限性和无法用于对实验系统进行全面的数据收集问题,对大流量止回阀实验系统的快速预测模型技术进行了研究,建立了实验系统的快速预测模型,进行了快速预测模型的结果分析。首先,搭建了实体模型,根据大流量止回阀实验系统的结构,结合实验系统的工作原理对其进行了简化,并进行了有限元分析;然后,利用快速预测模型的关键技术构建了实验系统数据库,进行了实验系统的样本采集;通过比对不同机器学习算法的预测准确率,选择了随机森林算法,并建立了实验系统内压与应力应变的关系;最后,进行了快速预测模型的结果分析,并完成了实验系统整体预测实验和实验系统部件单独预测实验。研究结果表明:采用随机森林(RF)算法建立的快速预测模型,拟合优度(R 2)达到了0.99,相较于深度神经网络(DNN)算法和梯度提升树(GBDT)算法,拟合优度(R 2)提高了68.97%和51.47%。实验系统整体预测与实验系统部件单独预测的对比试验结果表明:整体预测模型的预测速度更快,且精度可以达到97.43%。 展开更多
关键词 大流量旋启式止回阀 单向阀 随机森林算法 响应时间 深度神经网络 梯度提升树 决定系数