针对强迫导向油循环风冷(oir directrd air forced,ODAF)结构变压器负荷能力受温升约束影响的问题,提出了3种负荷类型情况下变压器负荷能力评估方法。首先,考虑风扇与油泵的运行状态以及油粘度变化对热阻的影响等因素,基于热电类比法建...针对强迫导向油循环风冷(oir directrd air forced,ODAF)结构变压器负荷能力受温升约束影响的问题,提出了3种负荷类型情况下变压器负荷能力评估方法。首先,考虑风扇与油泵的运行状态以及油粘度变化对热阻的影响等因素,基于热电类比法建立了变压器热路模型,以计算绕组热点与顶部油温度;其次,采用粒子群优化(particle swarm optimization,PSO)算法拟合热路模型参数,并基于2台不同型号变压器的运行数据,对热路模型的计算精度与拟合参数适用性进行有效性验证;最后,参考GB/T1094.7负载导则给出的温升限值,基于温升特性提出了负荷能力评估模型。分析结果表明,该研究所提热路模型计算热点温度的误差不大于2.35℃,在工程允许范围内;正常周期性负荷下当环境温度低于1℃时,关闭1组子散热器后仍满足温升约束。展开更多
To avoid the nonuniform phenomena of heat and mass transfer of metallurgical powdery materials caused by conventional heating method,the temperature rise characteristics of carbon-containing chromite ore fines in the ...To avoid the nonuniform phenomena of heat and mass transfer of metallurgical powdery materials caused by conventional heating method,the temperature rise characteristics of carbon-containing chromite ore fines in the microwave field were investigated using microwave heating in a microwave metallurgical furnace.The experimental results show that the carbon-containing chromite ore fines have better temperature rise characteristics in the microwave field at a frequency of 2.45 GHz.After heated in the microwave field of 10 kW,the temperature of 1 kg carbon-containing chromite ore fines rose up to 1 100 ℃ in 7 min,at a temperature rise rate of 157.1(℃·min-1·kg-1),whereas the temperature of 1 kg carbon-containing magnetite ore fines rose only up to 1 000 ℃ in 10 min,at a temperature rise rate of 100(℃·min-1·kg-1).With increasing carbon-fitting ratios and by adding calcic lime,their heating effects changed regularly.展开更多
High speed on/off valve(HSV)is an essential component in aerospace digital hydraulic systems(ADHS).Dynamic performance and temperature rising characteristic are two important features,which determine the performance o...High speed on/off valve(HSV)is an essential component in aerospace digital hydraulic systems(ADHS).Dynamic performance and temperature rising characteristic are two important features,which determine the performance of HSV,and affect the response speed and reliability of ADHS.Increasing the driving voltage is an effective method for improving the dynamic performance of HSV.However,continuous high voltage excitation will lead to more wasted energy,higher temperature rising and lower reliability.To solve this problem,a pre-excitation control algorithm(PECA)is proposed in this paper based on the theoretical model of the influence of electrical parameters on dynamic performance and temperature rising characteristics.In PECA,an appropriate initial coil current is generated by pre-excitation instead of increasing driving voltage,which significantly shortens the switching delay time.Then,based on real-time current online calculation and feedback mechanism,the adaptive switching of five equivalent voltages is realized.Consequently,the coil current can be rapidly kept at the expected state without consuming more energy and generating more heat.Results indicate that compared with conventional PWM control algorithm,the PECA can improve dynamic performance of HSV,shorten the total switching time by 71.5%,and increase the maximum operation frequency.Therefore,the linear area of flow characteristic is expended by 80.0%,the adjusting time of HSV-controlled system is reduced by 23%,while shortening steady error by 46.7%.Moreover,the temperature rising characteristics of HSV are better,the maximum operation temperature is reduced by 68.6%,and the time to reach the steady state temperature is shortened by 20%.From the results,it can be concluded that the PECA is not only an effective and practical control algorithm for improving the performance of HSVs and HSV-controlled systems while reducing the heat generation and decreasing the temperature rising of HSV,but also can be a potential solution in ADHS.展开更多
In this paper,the subdomain analysis model of the eddy current brake(ECB)is established.By comparing with the finite element method,the accuracies of the subdomain model and the finite element model are verified.Furth...In this paper,the subdomain analysis model of the eddy current brake(ECB)is established.By comparing with the finite element method,the accuracies of the subdomain model and the finite element model are verified.Furthermore,the resistance characteristics of radial,axial,andHalbach arrays under impact load are calculated and compared.The axial array has a large braking force coefficient but low critical velocity.The radial array has a low braking force coefficient but high critical velocity.The Halbach array has the advantages of the first two arrays.Not only the braking force coefficient is large,but also the critical speed is high.The parameter analysis of the Halbach array is further carried out.The inner tube thickness and air gap length are the sensitive factors of resistance characteristics.The demagnetization effect is significantly enhanced by the increase of the inner tube thickness.In order to ensure that the ECB does not overheat,the electromagnetic-thermal coupling model is established based on the heat transfer theory.The temperature rise of the inner tube is obvious while that of the permanentmagnet is small.The temperature rise of the inner tube is more than 20 K each time,and that of the permanent magnet is less than 1 K each time.展开更多
基金Item Sponsored by National Natural Science Foundation of China and Baoshan Iron and Steel Group Co(50474083)
文摘To avoid the nonuniform phenomena of heat and mass transfer of metallurgical powdery materials caused by conventional heating method,the temperature rise characteristics of carbon-containing chromite ore fines in the microwave field were investigated using microwave heating in a microwave metallurgical furnace.The experimental results show that the carbon-containing chromite ore fines have better temperature rise characteristics in the microwave field at a frequency of 2.45 GHz.After heated in the microwave field of 10 kW,the temperature of 1 kg carbon-containing chromite ore fines rose up to 1 100 ℃ in 7 min,at a temperature rise rate of 157.1(℃·min-1·kg-1),whereas the temperature of 1 kg carbon-containing magnetite ore fines rose only up to 1 000 ℃ in 10 min,at a temperature rise rate of 100(℃·min-1·kg-1).With increasing carbon-fitting ratios and by adding calcic lime,their heating effects changed regularly.
基金the National Natural Science Foundation of China(No.52005441)Young Elite Scientist Sponsorship Program by CAST(No.2022QNRC001)+3 种基金Natural Science Foundation of Zhejiang Province(No.LQ21E050017)“Pioneer”and“Leading Goose”R&D Program of Zhejiang Province(Nos.2022C01122 and 2022C01132)Postdoctoral Science Foundation(Nos.2021M692777 and 2021T140594)State Key Laboratory of Mechanical System and Vibration(No.MSV202316).
文摘High speed on/off valve(HSV)is an essential component in aerospace digital hydraulic systems(ADHS).Dynamic performance and temperature rising characteristic are two important features,which determine the performance of HSV,and affect the response speed and reliability of ADHS.Increasing the driving voltage is an effective method for improving the dynamic performance of HSV.However,continuous high voltage excitation will lead to more wasted energy,higher temperature rising and lower reliability.To solve this problem,a pre-excitation control algorithm(PECA)is proposed in this paper based on the theoretical model of the influence of electrical parameters on dynamic performance and temperature rising characteristics.In PECA,an appropriate initial coil current is generated by pre-excitation instead of increasing driving voltage,which significantly shortens the switching delay time.Then,based on real-time current online calculation and feedback mechanism,the adaptive switching of five equivalent voltages is realized.Consequently,the coil current can be rapidly kept at the expected state without consuming more energy and generating more heat.Results indicate that compared with conventional PWM control algorithm,the PECA can improve dynamic performance of HSV,shorten the total switching time by 71.5%,and increase the maximum operation frequency.Therefore,the linear area of flow characteristic is expended by 80.0%,the adjusting time of HSV-controlled system is reduced by 23%,while shortening steady error by 46.7%.Moreover,the temperature rising characteristics of HSV are better,the maximum operation temperature is reduced by 68.6%,and the time to reach the steady state temperature is shortened by 20%.From the results,it can be concluded that the PECA is not only an effective and practical control algorithm for improving the performance of HSVs and HSV-controlled systems while reducing the heat generation and decreasing the temperature rising of HSV,but also can be a potential solution in ADHS.
基金supported by the National Natural Science Foundation of China(Grant No.51705253).
文摘In this paper,the subdomain analysis model of the eddy current brake(ECB)is established.By comparing with the finite element method,the accuracies of the subdomain model and the finite element model are verified.Furthermore,the resistance characteristics of radial,axial,andHalbach arrays under impact load are calculated and compared.The axial array has a large braking force coefficient but low critical velocity.The radial array has a low braking force coefficient but high critical velocity.The Halbach array has the advantages of the first two arrays.Not only the braking force coefficient is large,but also the critical speed is high.The parameter analysis of the Halbach array is further carried out.The inner tube thickness and air gap length are the sensitive factors of resistance characteristics.The demagnetization effect is significantly enhanced by the increase of the inner tube thickness.In order to ensure that the ECB does not overheat,the electromagnetic-thermal coupling model is established based on the heat transfer theory.The temperature rise of the inner tube is obvious while that of the permanentmagnet is small.The temperature rise of the inner tube is more than 20 K each time,and that of the permanent magnet is less than 1 K each time.