期刊文献+
共找到37篇文章
< 1 2 >
每页显示 20 50 100
Mountain Glacier Flow Velocities Analyzed from Satellite Optical Images
1
作者 Lei Huang Zhen Li 《Research in Cold and Arid Regions》 2010年第1期59-66,共8页
Mountain glaciers are sensitive to environment. It is important to acquire ice flow velocities over time for glacier research and hazard forecast. For this paper, cross-correlating of optical images is used to monitor... Mountain glaciers are sensitive to environment. It is important to acquire ice flow velocities over time for glacier research and hazard forecast. For this paper, cross-correlating of optical images is used to monitor ice flow velocities, and an improvement, which is called "moving grid," is made to this method. For this research, two remote-sensing images in a certain glacier area, dur-ing different times are selected. The first image is divided into grids, and we calculated the correlation coefficient of each window in the grid with the window on the second image. The window with the highest correlation coefficient is considered the counter-part one on the first image. The displacement of the two corresponding windows is the movement of the glacier, and it is used to calculate glacier surface velocity. Compared to the traditional way of dividing an image with ascertain grid, this method uses small steps to move the grid from one location to another adjacent location until the whole glacier area is covered in the image, thus in-creasing corresponding point density. We selected a glacier in the Tianshan Mountains for this experiment and used two re-mote-sensing images with a 10-year interval to determine this method. 展开更多
关键词 glacier flow satellite optical image correlation grid
下载PDF
Unsaturated flow conditioned on 3D images of soil moisture
2
《Global Geology》 1998年第1期80-80,共1页
关键词 FLOW SOIL Unsaturated flow conditioned on 3D images of soil moisture
下载PDF
Application and prospects of AI-based radiomics in ultrasound diagnosis 被引量:1
3
作者 Haoyan Zhang Zheling Meng +2 位作者 Jinyu Ru Yaqing Meng Kun Wang 《Visual Computing for Industry,Biomedicine,and Art》 EI 2023年第1期288-303,共16页
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora... Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis. 展开更多
关键词 Radiomics Ultrasound imaging Artificial intelligence Deep learning B-mode ultrasound Color Doppler flow imaging Ultrasound elastography Contrast-enhanced ultrasound Multimodal ultrasound
下载PDF
Clinical Value of Ultrosound in the Diagnosis of Testicular Tumor
4
作者 罗冬喜 杨为民 +3 位作者 叶章群 刘继红 孟磊 周四维 《The Chinese-German Journal of Clinical Oncology》 CAS 2003年第4期231-233,253,共4页
Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography... Objective: To summarize the clinical experience of diagnosis and treatment of the testicular tumors.Methods: Retrospective analysis of 42 adult patients with testicular cancers was carried out.Results: Ultrasonography (B-ultrasound and color Doppler flow imaging) was performed on 37 cases. One case was misdiagnosed. Surgical management was carried out in 42 cases and postoperational radiation therapy or chemotherapy was performed. The 1–5 year postoperative survival rate was totally 100%.Conclusion: B-ultrasound, especially color Doppler flow imaging, with the advantages of noninvasiveness and inexpensiveness was most useful and should be firstly employed in diagnosing the testicular tumor. The favorable prognosis can be obtained if an early diagnosis is made and the early treatment is performed. Key words testicular tumor - B-ultrasound - color Doppler flow imaging 展开更多
关键词 testicular tumor B-ULTRASOUND color Doppler flow imaging
下载PDF
Orbital decompression surgery and horse chestnut seed extract improved superior orbital vein blood flow in patients with thyroid-associated ophthalmopathy 被引量:5
5
作者 Yu-Jie Wu Xin Wei +1 位作者 Man-Yi Xiao Wei Xiong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第6期869-875,共7页
AIM: To evaluate the efficacy and safety of orbital decomposition (OD) surgery in combination with horse chestnut seed extract (HCSE), as compared to OD atone, in patients with thyroid-associated ophthalmopathy ... AIM: To evaluate the efficacy and safety of orbital decomposition (OD) surgery in combination with horse chestnut seed extract (HCSE), as compared to OD atone, in patients with thyroid-associated ophthalmopathy (TAO). METHODS: Sixty-two orbits from 62 TAO patients were randomly assigned to OD or OD+HCSE at 1:1 ratio (31 received OD alone, 31 received OD +HCSE). Forty-two orbits from 21 healthy subjects were used as controls. Complete ophthalmic examination and color Doppler flow imaging (CDFI) were performed before surgery and 3mo post-surgery on all 62 orbits from the TAO patients. CDFI were also performed on the 42 control orbits, The effect of OD +HCSE and OD alone on TAO orbits was compared on several endpoints, including superior ophthalmic vein blood flow (SOVBF) parameters, subjective assessment, soft tissue involvement, lid retraction, diplopia, eye movement restriction, degree of exophthalmos, and intraocular pressure. The control orbits were used as reference for the SOVBF parameters. RESULTS: OD surgery with or without HCSE improved SOVBF, symptoms and soft tissue involvement, decreased degree of exophthalmos and intraocular pressure in orbits of TAO patients. The OD +HCSE combination led to significantly better improvement of SOVBF than OD alone. The differences between the reductions of SOVBF in the two groups are 1.26 cmls in max-volecity and 0.52 cm/s in min-voiecity (P〈0.0001). CONCLUSION: SOVBF is significantly reduced in the orbits affected with TAO, indicating that congestion may be an important factor contributing to TAO pathogenesis. OD surgery improves the SOVBF, and combination of HCSE medication and OD surgery further improved venous return than OD surgery alone. 展开更多
关键词 thyroid-associated ophthalmopathy colorDoppler flow imaging superior orbital vein orbitaldecompression horse chestnut seed extract
下载PDF
Real-time Three-Dimensional Color Doppler Flow Imaging: An Improved Technique for Quantitative Analysis of Aortic Regurgitation 被引量:3
6
作者 吕清 刘夏天 +3 位作者 谢明星 王新房 王静 庄磊 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2006年第1期148-152,共5页
The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT... The recently introduced real-time three-dimensional color Doppler flow imaging (RT-3D CDFI) technique provides a quick and accurate calculation of regurgitant jet volume (RJV) and fraction. In order to evaluate RT-3D CDFI in the noninvasive assessment of aortic RJV and regurgitant jet fraction (RJF) in patients with isolated aortic regurgitation, real-time three-dimensional echocardiographic studies were performed on 23 patients with isolated aortic regurgitation to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV) and RJV, and then RJF could be calculated. The regurgitant volume (RV) and regurgitant fraction (RF) calculated by two-dimensional pulsed Doppler (2D-PD) method served as reference values. The results showed that aortic RJV measured by the RT-3D CDFI method showed a good correlation with the 2D-PD measurements (r= 0.93, Y=0.89X+ 3.9, SEE= 8.6 mL, P〈0.001 ); the mean (SD) difference between the two methods was - 1.5 (9.8) mL. % RJF estimated by the RT-3D CDFI method was also correlated well with the values obtained by the 2D-PD method (r=0.88, Y=0.71X+ 14.8, SEE= 6.4 %, P〈0. 001); the mean (SD) difference between the two methods was -1.2 (7.9) %. It was suggested that the newly developed RT-3D CDFI technique was feasible in the majority of patients. In patients with eccentric aortic regurgitation, this new modality provides additional information to that obtained from the two-dimensional examination, which overcomes the inherent limitations of two-dimensional echocardiography by depicting the full extent of the jet trajectory. In addition, the RT-3D CDFI method is quick and accurate in calculating RJV and RJF. 展开更多
关键词 real-time three-dimensional echocardiography color Doppler flow imaging aortic regurgitation
下载PDF
Flow control of micro-ramps on supersonic forward-facing step flow 被引量:2
7
作者 张庆虎 朱涛 +1 位作者 易仕和 吴岸平 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期233-237,共5页
The effects of the micro-ramps on supersonic turbulent flow over a forward-facing step(FFS) was experimentally investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scatt... The effects of the micro-ramps on supersonic turbulent flow over a forward-facing step(FFS) was experimentally investigated in a supersonic low-noise wind tunnel at Mach number 3 using nano-tracer planar laser scattering(NPLS)and particle image velocimetry(PIV) techniques. High spatiotemporal resolution images and velocity fields of supersonic flow over the testing model were captured. The fine structures and their spatial evolutionary characteristics without and with the micro-ramps were revealed and compared. The large-scale structures generated by the micro-ramps can survive the downstream FFS flowfield. The micro-ramps control on the flow separation and the separation shock unsteadiness was investigated by PIV results. With the micro-ramps, the reduction in the range of the reversal flow zone in streamwise direction is 50% and the turbulence intensity is also reduced. Moreover, the reduction in the average separated region and in separation shock unsteadiness are 47% and 26%, respectively. The results indicate that the micro-ramps are effective in reducing the flow separation and the separation shock unsteadiness. 展开更多
关键词 flow control micro-ramps separated flows flow imaging
下载PDF
The Study of Ovarian Artery Hemodynamics in Patients with Infertility by Color Doppler Energy 被引量:2
8
作者 肖先桃 乐桂蓉 +1 位作者 张友耿 黎春蕾 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2001年第1期42-43,共2页
Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI... Seventy four cases of infertility were examined to study the hemodynamics of the bilateral ovarian arteries at 21st day during the corpus luteum phase by color Doppler energy(CDE) and color Doppler flow imaging (CDFI). All the patients were verified by laparoscopy, fallopian tube patency examination and ovarian function test. Twenty two healthy women served as controls. The results showed that the difference of resistance index(RI)and pulsatility index (PI) of bilateral ovarian arteries between the infertility and the normal controls had statistical significance ( P <0.01), and the PI showed negative correlation with the thickness of endometrium (left side: r =0.724, P <0.01; right side: r =0.756, P <0.01). The results also showed that CDE was more sensitive than CDFI in displaying the ovarian arteries. It could be concluded that the elevated resistance of ovarian artery during the corpus luteum phase was one of the important factors that resulted in infertility. 展开更多
关键词 ovarian artery color Doppler flow imaging color Doppler energy resistance index pulsatility index INFERTILITY
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
9
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color Doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
Morphological Effects of Natural Products on Schizosaccharomyces pombe Measured by Imaging Flow Cytometry 被引量:1
10
作者 Joel Heisler Lindsay Elvir +3 位作者 Farah Barnouti Erica Charles Tom D.Wolkow Radha Pyati 《Natural Products and Bioprospecting》 CAS 2014年第1期27-35,共9页
Gaining a full understanding of the mechanisms of action of natural products as therapeutic agents includes observing the effects of natural products on cellular morphology,because abnormal cellular morphology is an i... Gaining a full understanding of the mechanisms of action of natural products as therapeutic agents includes observing the effects of natural products on cellular morphology,because abnormal cellular morphology is an important aspect of cellular transformations that occur as part of disease states.In this study a set of natural products was examined in search of small molecules that influence the cylindrical morphology of fission yeast Schizosaccharomyces pombe.Imaging flow cytometry of large populations of S.pombe exposed to natural products captured cell images and revealed changes in mean length and aspect ratio of cells.Several natural products were found to alter S.pombe’s morphology relative to control,in terms of elongating cells,shrinking them,or making them more round.These results may facilitate future investigations into methods by which cells establish and maintain specific shapes. 展开更多
关键词 Schizosaccharomyces pombe MORPHOLOGY Natural products Imaging flow cytometry Aspect ratio Fission yeast
下载PDF
Demands and technical developments of clinical flow cytometry with emphasis in quantitative,spectral,and imaging capabilities 被引量:1
11
作者 Ting Zhang Mengge Gao +6 位作者 Xiao Chen Chiyuan Gao Shilun Feng Deyong Chen Junbo Wang Xiaosu Zhao Jian Chen 《Nanotechnology and Precision Engineering》 CAS CSCD 2022年第4期46-55,共10页
As the gold-standard method for single-cell analysis,flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells.This review highlights the demands for clinical flow c... As the gold-standard method for single-cell analysis,flow cytometry enables high-throughput and multiple-parameter characterization of individual biological cells.This review highlights the demands for clinical flow cytometry in laboratory hematology(e.g.,diagnoses of minimal residual disease and various types of leukemia),summarizes state-of-the-art clinical flow cytometers(e.g.,FACSLyricTMby Becton Dickinson,DxFLEX by Beckman Coulter),then considers innovative technical improvements in flow cytometry(including quantitative,spectral,and imaging approaches)to address the limitations of clinical flow cytometry in hematology diagnosis.Finally,driven by these clinical demands,future developments in clinical flow cytometry are suggested. 展开更多
关键词 Clinical demand Clinical flow cytometry Quantitative flow cytometry Spectral flow cytometry Imaging flow cytometry
下载PDF
CHARACTERISTICS OF TWO-DIMENSIONAL AND COLOR DOPPLER ULTRASONOGRAPHY IN GRAVES'DISEASE 被引量:1
12
作者 李建初 张缙熙 +3 位作者 白耀 程玉芳 蔡胜 孙宏宇 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第2期104-107,共4页
Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and ... Color Doppler flow imaging(CDFI) was performed in 24 patients with Graves' disease and the results were compared with those from 8 patients with Hashimoto's disease, 6 patients with simple diffuse goiter, and 15 normal volunteers. All cases were confirmed by clinical, laboratory tests or pathology. CDFI of Graves' disease showed diffuse or localized hypoechoes within the thyroid glands, rich flow signals in the hypoechoes, accelerated flow velocity, and decreased resistance in the superior thyroid arteries(STA) and arteries within the glands. These appearances were characteristic as compared with the controls. The rate of flow in STA of Graves' disease patients was 8 to 10 times higher than that in the normal volunteers. This study demonstrates that CDFI is convenient and efficient as compared with isotope scan and some other laboratory tests, and can be widely used in the diagnosis of Graves' disase. 展开更多
关键词 color Doppler flow imaging Graves'disease
下载PDF
COMPUTATIONAL AND EXPERI-MENTAL STUDY ON TIP LEAKAGE VORTEX OF CIRCUMFERENTIAL SKEWED BLADES 被引量:4
13
作者 LI Yang OUYANG Hua DU Zhaohui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第2期82-87,共6页
In the steady operation condition, the experiments and the numerical simulations are used to investigate the tip leakage flow fields in three low pressure axial flow fans with three kinds of circumferential skewed rot... In the steady operation condition, the experiments and the numerical simulations are used to investigate the tip leakage flow fields in three low pressure axial flow fans with three kinds of circumferential skewed rotors, including the radial rotor, the forward-skewed rotor and the back- ward-skewed rotor. The three-dimensional viscous flow fields of the fans are computed. In the experiments, the two-dimensional plane particle image velocimetry (PIV) system is used to measure the flow fields in the tip region of three different pitchwise positions of each fan. The results show that the computational results agree well with the experimental data in the flow field of the tip region of each fan. The tip leakage vortex core segments based on method of the eigenmode analysis can display clearly some characteristics of the tip leakage vortex, such as the origination position of tip leak- age vortex, the development of vortex strength, and so on. Compared with the radial rotor, the other two skewed rotors can increase the stability of the tip leakage vortex and the increment in the forward-skewed rotor is more than that in the backward-skewed one. Among the tip leakage vortices of the three rotors, the velocity of the vortex in the forward-skewed rotor is th6 highest in the circumferential direction and the lowest in the axial direction. 展开更多
关键词 Low pressure axial flow fan Tip leakage vortex Particle image velocimetry (PIV) Eigenmode analysis
下载PDF
A brief report on MRI investigation of experimental traumatic brain injury 被引量:2
14
作者 Timothy Q.Duong Lora T.Watts 《Neural Regeneration Research》 SCIE CAS CSCD 2016年第1期15-17,共3页
Traumatic brain injury is a major cause of death and disability. This is a brief report based on a symposium presentation to the 2014 Chinese Neurotrauma Association Meeting in San Francisco, USA. It covers the work f... Traumatic brain injury is a major cause of death and disability. This is a brief report based on a symposium presentation to the 2014 Chinese Neurotrauma Association Meeting in San Francisco, USA. It covers the work from our laboratory in applying multimodal MRI to study experimental traumatic brain injury in rats with comparisons made to behavioral tests and histology. MRI protocols include structural, perfusion, manganese-enhanced, diffusion-tensor MRI, and MRI of blood-brain barrier integrity and cerebrovascular reactivity. 展开更多
关键词 MRI traumatic brain injury magnetic resonance imaging diffusion tensor imaging cerebral blood flow
下载PDF
Numerical simulation of the pulsing air separation field based on CFD 被引量:12
15
作者 He Jingfeng He Yaqun +2 位作者 Zhao Yuemin Duan Chenlong Ye Cuiling 《International Journal of Mining Science and Technology》 2012年第2期201-207,共7页
The flow field of pulsing air separation is normally in an unsteady turbulence state.With the application of the basic principles of multiphase turbulent flows,we established the dynamical computational model,which sh... The flow field of pulsing air separation is normally in an unsteady turbulence state.With the application of the basic principles of multiphase turbulent flows,we established the dynamical computational model,which shows a remarkable variation of the unstable pulsing air flow field.CFD(computational fluid dynamics) was used to conduct the numerical simulation of the actual geometric model of the classifier.The inside velocity of the flowing fields was analyzed later.The simulation results indicate that the designed structure of the active pulsing air classifier provided a favorable environment for the separation of the particles with different physical characters by density.We shot the movement behaviors of the typical tracer grains in the active pulsing flow field using a high speed dynamic camera.The displacement and velocity curves of the particles in the continuous impulse periods were then analyzed.The experimental results indicate that the effective separation by density of the particles with the same settling velocity and different ranges of the density and particle size can be achieved in the active pulsing airflow field.The experimental results provide an agreement with the simulation results. 展开更多
关键词 Pulsing air separation flow fieldMultiphase turbulence flowNumerical simulationHigh-speed dynamic camera imaging
下载PDF
Tomographic PIV investigation on coherent vortex structures over shark-skin-inspired drag-reducing riblets 被引量:8
16
作者 Shao-Qiong Yang Shan Li +2 位作者 Hai-Ping Tian Qing-Yi Wang Nan Jiang 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2016年第2期284-294,共11页
Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-insp... Nature has shown us that the microstructure of the skin of fast-swimming sharks in the ocean can reduce the skin friction drag due to the well-known shark-skin effect.In the present study,the effect of shark-skin-inspired riblets on coherent vortex structures in a turbulent boundary layer(TBL) is investigated.This is done by means of tomographic particle image velocimetry(TPIV) measurements in channel fl ws over an acrylic plate of drag-reducing riblets at a friction Reynolds number of 190.The turbulent fl ws over drag-reducing riblets are verifie by a planar time-resolved particle image velocimetry(TRPIV) system initially,and then the TPIV measurements are performed.Two-dimensional(2D) experimental results with a dragreduction rate of around 4.81% are clearly visible over triangle riblets with a peak-to-peak spacing s+of 14,indicating from the drag-reducing performance that the buffer layer within the TBL has thickened;the logarithmic law region has shifted upward and the Reynolds shear stress decreased.A comparison of the spatial topological distributions of the spanwise vorticity of coherent vortex structures extracted at different wall-normal heights through the improved quadrant splitting method shows that riblets weaken the amplitudesof the spanwise vorticity when ejection(Q2) and sweep(Q4) events occur at the near wall,having the greatest effect on Q4 events in particular.The so-called quadrupole statistical model for coherent structures in the whole TBL is verified Meanwhile,their spatial conditional-averaged topological shapes and the spatial scales of quadrupole coherent vortex structures as a whole in the overlying turbulent fl w over riblets are changed,suggesting that the riblets dampen the momentum and energy exchange between the regions of near-wall and outer portion of the TBL by depressing the bursting events(Q2 and Q4),thereby reducing the skin friction drag. 展开更多
关键词 Turbulent boundary layer(TBL) Coherent vortex structure Flow control Drag reduction Shark-skininspired riblet Tomographic particle image velocimetry(TPIV)
下载PDF
Feasibility of Transabdominal Real-time CDFI and HDFI Techniques for Fetal Pulmonary Vein Display in the First Trimester
17
作者 Dong-mei LIN Yun-xiao ZHU +4 位作者 Ying TAN Yu-jun HUANG Kun YUAN Wen-fen LIU Zuo-feng XU 《Current Medical Science》 SCIE CAS 2022年第3期635-641,共7页
Objective This study aimed to assess the feasibility and usefulness of transabdominal color Doppler flow imaging(CDFI)technology and the high-definition flow imaging(HDFI)technique in detecting fetal pulmonary veins(P... Objective This study aimed to assess the feasibility and usefulness of transabdominal color Doppler flow imaging(CDFI)technology and the high-definition flow imaging(HDFI)technique in detecting fetal pulmonary veins(PVs)in the first trimester(11–13^(+6)weeks).Methods From December 2018 to October 2019,328 pregnant women with 328 normal singleton fetuses(crown-rump length:45–84 mm)who had undergone CDFI and HDFI scans for fetal heart and vessel examination were enrolled in this study.The cases were divided into three groups according to the gestational age:group A,11^(+0)−11^(+6)weeks;group B,12^(+0)−12^(+6)weeks;and group C,13^(+0)−13^(+6)weeks.Baseline sonograms and CDFI and HDFI images were analyzed by two senior radiologists independently and blindly.The abilities of CDFI and HDFI to display PVs were compared.Results Successful PV display rates via CDFI and HDFI were 2.3%and 68.2%(P<0.01),22.4%and 82.4%(P<0.01),41.5%and 91.2%(P<0.01)for group A,group B,and group C,respectively.The total successful display rates for the two methods were 28.9%(CDFI)and 84.8%(HDFI)(P<0.01).Conclusions The HDFI technique is more valuable than CDFI for detecting PVs in early pregnancy(11–13^(+6)weeks).HDFI can detect at least one PV in all cases and may be used to detect pulmonary venous anomalies early. 展开更多
关键词 pulmonary vein first trimester prenatal sonography high-definition flow imaging color Doppler flow imaging
下载PDF
COLOR FLOW IMAGING OF HEPATIC CARCINOMA
18
作者 Xu Zhizhang Wang Wenping(Department of Diagnostic Ultrasound,Zhongshan Hospital,Shanghai Medical University,Shanghai 200032) 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 1994年第1期45-50,共6页
Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by s... Color flow imaging(CFI)ultrasound technique can discover the tumor vascularity and superimposed it to convontional B-mode ultrasonogram in real-time. The flow velocity on spectral Doppler sonogram can be measured by setting the sample volume to any selected site.One hundred and thirty-six patients with solid hepatic space-occupied lesions had been admitted and 113 cases were confirmed by operation and pathology,23 patients were strongly suspected by hepatic angiography (HAA).Ninety nine patients with 109 nodules were finally diagnosed as hepatic cellular carcinoma(HCC).According to color flow distribution pattern,3 kinds of color configuation had been nominated.Tumor vascularity discovered by CFI,especially the arterial blood flow was easy to be recognized,and its emerge rate was quite different between HCC group(94.5%)and hemangioma(HCH)group(17.07%)(P<0.01).Spectral Doppler studies were also carried out in these cases and the detectability of arterial flow in HCC group(95.41%)was much higher than that to HCH group (21. 95%) (P<0. 005).Resistant index(RI)and pulsatile index(PI)could be used to differentiate HCC (>0. 50 and >0.80 respectively)from HCH (P<0.001 and P<0.001 respectively).Arterial-portal(A-P) shunt could also be detected by CFI and spectral Doppler(mostly its Vmax>0.6m/s).The detection rate of A-P shunt was 64% in HCC group,but no case could be detected in HCH group. 展开更多
关键词 Hepatic carcinoma Color flow imaging(CFI) Spectral Doppler sonogram Resistant index(RI) Pulsatile index(PI) Hepatic artery angiography(HAA).
下载PDF
Value of Acceleration Flow in the Left Anterior Descending Coronary Artery for the Detection of Coronary Artery Stenosis by Transthoracic Coronary Color Doppler Echocardiography
19
作者 陈斌 邓又斌 +4 位作者 杨好意 阮燕菲 常青 毕小军 王红英 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2005年第5期597-600,共4页
Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left... Summary: Whether the localized flow acceleration occurs in the resting stenotie left anterior descending coronary artery was explored and its value for detection of coronary stenosis estimated. Blood flow in the left anterior descending coronary arteries in 45 patients was detected by transthoratio color Doppler echocardiograph and multipoint pulse Doppler spectrums were recorded in the same segment. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was calculated. The ratio ≥1.5 was the cutoff value for the presence of localized acceleration flow. There were 23 patients with localized acceleration flow examined by eehoeardiography. Twenty of them were found to have luminal diameter stenosis (60%-98%) in the left anterior descending coronary arteries by coronary angiography and 3 patients were normal. There were 22 patients without localized acceleration flow examined by eehoeardiography. Eighteen of them had no or %60 stenosis. Four patients had serious stenosis (≥95%) or occluded segments in the left anterior descending coronary arteries on coronary angiography. The ratio of the maximal peak diastolic velocity to the minimal peak diastolic velocity was significantly higher in patients with left anterior descending coronary artery stenosis than that in those without stenosis (1.9±0.3 vs 1.3±0.2, P〈0.01) and it correlated significantly with left anterior descending coronary artery stenosis (r=0.77, P〈0.01). The specificity by using the ratio≥1. 5 for stenosis detection was 85.7% (18/ 21), and the sensitivity was 83.3% (20/24). This study demonstrated that local blood flow velocity was increased in the resting stenotie left anterior descending coronary artery. Transthoraeie color Doppler eehoeardiography is a reliable noninvasive method to detect localized acceleration flow in the left anterior descending coronary artery stenosis and it is useful in the noninvasive diagnosis of stenosis in the left anterior descending coronary artery. 展开更多
关键词 ECHOCARDIOGRAPHY coronary artery STENOSIS color Doppler flow imaging
下载PDF
PRELIMINARY APPLICATION OF COLOR DOPPLER FLOW IMAGING IN THE LOCALIZATION OF PARATHYROID ADENOMAS
20
作者 张缙熙 李建初 《Chinese Medical Sciences Journal》 CAS CSCD 1994年第3期187-189,共3页
From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vesse... From December 1991 to April 1993, we performed color Doppler flow imaging (CDFI) in 11 patients with parathyroid adenoma, and all cases were confirmed by operation and pathology. In all the parathyroid adenomas,vessels were clearly revealed at the periphery of the upper pole and/or anterior periphery, where arterial signals were elicited. These arteries had branches into the adenomas and originated from inferior thyroid arteries on the same side in most cases. The internal flow signals were increased markedly as compared to normal thyroid, and high-velocity arterial signals were detected. Because of the thyroid' s rich blood supply and landmark peripheral vessels, CDFI can distinguish parathyroid foci from thyroid nodules, lymph nodes, and normal tissues and provide a sound basis for the diagnosis of small parathyroid foci. 展开更多
关键词 color Doppler flow imaging parathyroid adenoma localization diagnosis
下载PDF
上一页 1 2 下一页 到第
使用帮助 返回顶部