期刊文献+
共找到1,656篇文章
< 1 2 83 >
每页显示 20 50 100
Dynamic grouping control of electric vehicles based on improved k-means algorithm for wind power fluctuations suppression 被引量:1
1
作者 Yang Yu Mai Liu +2 位作者 Dongyang Chen Yuhang Huo Wentao Lu 《Global Energy Interconnection》 EI CSCD 2023年第5期542-553,共12页
To address the significant lifecycle degradation and inadequate state of charge(SOC)balance of electric vehicles(EVs)when mitigating wind power fluctuations,a dynamic grouping control strategy is proposed for EVs base... To address the significant lifecycle degradation and inadequate state of charge(SOC)balance of electric vehicles(EVs)when mitigating wind power fluctuations,a dynamic grouping control strategy is proposed for EVs based on an improved k-means algorithm.First,a swing door trending(SDT)algorithm based on compression result feedback was designed to extract the feature data points of wind power.The gating coefficient of the SDT was adjusted based on the compression ratio and deviation,enabling the acquisition of grid-connected wind power signals through linear interpolation.Second,a novel algorithm called IDOA-KM is proposed,which utilizes the Improved Dingo Optimization Algorithm(IDOA)to optimize the clustering centers of the k-means algorithm,aiming to address its dependence and sensitivity on the initial centers.The EVs were categorized into priority charging,standby,and priority discharging groups using the IDOA-KM.Finally,an two-layer power distribution scheme for EVs was devised.The upper layer determines the charging/discharging sequences of the three EV groups and their corresponding power signals.The lower layer allocates power signals to each EV based on the maximum charging/discharging power or SOC equalization principles.The simulation results demonstrate the effectiveness of the proposed control strategy in accurately tracking grid power signals,smoothing wind power fluctuations,mitigating EV degradation,and enhancing the SOC balance. 展开更多
关键词 Electric vehicles Wind power fluctuation smoothing Improved k-means power allocation Swing door trending
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
2
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
Minimization of Reactive Power Fluctuation in JT-60SA Magnet Power Supply
3
作者 K. SHIMADA T. TERAKADO +5 位作者 K. YAMAUCHI M. MATSUKAWA O. BAULAIGUE R. COLETTI A. COLETTI L. NOVELLO 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第2期184-187,共4页
This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma ... This paper describes an asymmetric control method for the firing angle and a start/stop timing shift control of four thyristor converters called "Booster PS" to minimize the reactive power fluctuation during plasma initiation in JT-60SA. From the simulation using the "PSCAD/EMTDC" code, it is found that these control methods can drastically reduce the reac- tive power induced by the four units of the "Booster PS". In addition, the voltage fluctuation of the motor-generator connected to the "Booster PS" is expected to be suppressed. This can also contribute to achieve stable control of the JT-60SA magnet power supplies. 展开更多
关键词 JT-60SA power supply poroidal field coil reactive power fluctuation asym-metric control PSCAD/EMTDC
下载PDF
Influencing Factors of the Power Fluctuation on the Ultra High Voltage Transmission Line Caused by Faults at the Remote Ends of the Interconnected Grid
4
作者 Zhi An Ansi Wang +1 位作者 Huadong Sun Yong Tang 《Journal of Power and Energy Engineering》 2014年第4期624-631,共8页
After the North China grid and the Central China grid get into connection with the UHVAC demonstration, a new phenomenon is discovered according to some simulations. That is, the faults at the remote end of the UHV in... After the North China grid and the Central China grid get into connection with the UHVAC demonstration, a new phenomenon is discovered according to some simulations. That is, the faults at the remote end of the UHV interconnected grid will result in significant power fluctuation and voltage drop on the UHV transmission line and even system splitting. But the faults near the UHV line only have marginal effects. Further, the simulation results also indicate that the short-circuit current of the buses near the UHV line is larger than that of the buses far away from the UHV line. This phenomenon is divergent from the traditional view. In this paper, the detail will be introduced, and the factors influencing the system stability after faults are presented and analyzed. The results indicate that transmission power of the UHV line and of the lines between the remote end and the major grid influence the fluctuation on UHV line. The load model and the grid structure of the remote end also have effect on it. Finally, corresponding control scheme is presented to improve the operation conditions of the UHV interconnected grid and ensure its security and stability. 展开更多
关键词 Ultra High Voltage UHV Interconnected GRID FAULTS at REMOTE End power fluctuation
下载PDF
Forecast of Power Generation for Grid-Connected Photo-voltaic System Based on Grey Theory and Verification Model
5
作者 Ying-zi Li Jin-cang Niu Li Li 《Energy and Power Engineering》 2013年第4期177-181,共5页
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected... Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced. 展开更多
关键词 FORECAST of power Generation grid-connected Photovoltaic SYSTEM Data DISCRETIZATION GREEDY Algorithm Continuous Attributes ROUGH Sets
下载PDF
Influence of Control Modes of Grid-Connected Solar Photovoltaic Generation on Grid Power Flow
6
作者 Zakaria Al-Omari 《Engineering(科研)》 2014年第13期914-922,共9页
Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but... Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but it may manifest itself either positively or negatively, depending on the grid configuration, interface control modes, operation mode, and load profile. Grid-connected PV systems have three control options of the local voltage controller of the interface DC-AC converter. These control modes are Power Factor control, voltage control, and Droop Voltage control. This paper aims at evaluating and comparing the impacts of those control modes on the grid power flow. A set of evaluation criteria and indices is defined and mathematically formulated. Based on the requirements of the used program (Power Factory Dig Silent V14.1.3), a computation plan (algorithm) has been proposed. The algorithm has been applied to a typical weak network and a wide range of simulations has been carried out. Simulation results have been thoroughly discussed and important findings have been concluded. 展开更多
关键词 grid-connected PV Control MODES power Flow power FACTORY DIG SILENT Software
下载PDF
Research and Application of Probability Distribution of Wind Power Fluctuation Characteristics
7
作者 Huang Tong 《International Journal of Technology Management》 2014年第4期28-32,共5页
关键词 风电场建设 波动特征 概率分布 应用 风力发电 影响预测 实测数据 ANNS
下载PDF
Coordinated control strategy for a PV-storage grid-connected system based on a virtual synchronous generator 被引量:4
8
作者 Xing Zhang Qian Gao +3 位作者 Zixuan Guo Haizheng Zhang Ming Li Fei Li 《Global Energy Interconnection》 2020年第1期52-60,共9页
Due to the characteristics of intermittent photovoltaic power generation and power fluctuations in distributed photovoltaic power generation,photovoltaic grid-connected systems are usually equipped with energy storage... Due to the characteristics of intermittent photovoltaic power generation and power fluctuations in distributed photovoltaic power generation,photovoltaic grid-connected systems are usually equipped with energy storage units.Most of the structures combined with energy storage are used as the DC side.At the same time,virtual synchronous generators have been widely used in distributed power generation due to their inertial damping and frequency and voltage regulation.For the PV-storage grid-connected system based on virtual synchronous generators,the existing control strategy has unclear function allocation,fluctuations in photovoltaic inverter output power,and high requirements for coordinated control of PV arrays,energy storage units,and photovoltaic inverters,which make the control strategy more complicated.In order to solve the above problems,a control strategy for PV-storage grid-connected system based on a virtual synchronous generator is proposed.In this strategy,the energy storage unit implements maximum power point tracking,and the photovoltaic inverter implements a virtual synchronous generator algorithm,so that the functions implemented by each part of the system are clear,which reduces the requirements for coordinated control.At the same time,the smooth power command is used to suppress the fluctuation of the output power of the photovoltaic inverter.The simulation validates the effectiveness of the proposed method from three aspects:grid-connected operating conditions,frequency-modulated operating conditions,and illumination sudden-drop operating condition.Compared with the existing control strategies,the proposed method simplifies the control strategies and stabilizes the photovoltaic inverter fluctuation in the output power of the inverter. 展开更多
关键词 Photovoltaic power generation Energy STORAGE unit Virtual SYNCHRONOUS GENERATOR SMOOTH fluctuation COORDINATED control
下载PDF
Digitally Controlled Boost PFC Converters Operating with Large Scale Load Fluctuations 被引量:1
9
作者 刘艳丽 王清龙 +2 位作者 王宇翠 张烨 朱乐为 《Transactions of Tianjin University》 EI CAS 2014年第4期292-298,共7页
When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor... When boost power factor correction(PFC) circuit works with large scale load fluctuations, it is easy to cause a higher total harmonic distortion and a lower power factor because of traditional controllers and inductor current mode. To solve this problem, this paper proposes a PFC control system, which can operate with load fluctuations up to 1 000 W by using duty cycle feed-forward control theory to achieve smooth switching mode. The duty cycles in the next period of the control system are pre-estimated in the current cycle, which enhances the speeds of AD samplers and switching frequency, and reduces the cost and volume of the equipment to some extent. Introductions of system decoupling and feed-forward of input-voltage greatly improve the system performance. Both theoretical simulation and experimental results prove the advantage of the proposed scheme. 展开更多
关键词 PFC 升压式 负载 数字控制 转换器 功率因数校正 控制系统 电路工作原理
下载PDF
A Modified-Simplified MPPT Technique for Three-Phase Single-State Grid-Connected PV Systems
10
作者 Anuchit Aurairat Boonyang Plangklang 《Computers, Materials & Continua》 SCIE EI 2022年第8期2375-2395,共21页
Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focus... Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1. 展开更多
关键词 Single-state grid-connected model predictive control maximum power point estimation perturbation and observation
下载PDF
Measurement of Particle Velocity, Particle Size Distribution and Concentration in Particulate Suspension by Transmission Fluctuation Correlation Spectrometry
11
作者 Peng Gong 《International Journal of Clean Coal and Energy》 2022年第2期13-23,共11页
In coal-fired power generation industry, parameters such as particle size affect combustion efficiency. Especially in the application of two-phase flow clean energy, the parameters such as particle velocity, particle ... In coal-fired power generation industry, parameters such as particle size affect combustion efficiency. Especially in the application of two-phase flow clean energy, the parameters such as particle velocity, particle size distribution and concentration are very important, because the coal particle velocity, concentration or size range have an impact on the whole combustion process. This paper introduces an optical measurement setup based on the transmission fluctuation correlation spectrum measurement technique, which realizes the simultaneous measurement of particle velocity, particle size distribution and concentration. Compared with image method, ultrasonic spectrum method and other methods, the experimental device is simple and low-cost. 展开更多
关键词 On-Line Measurement Two-Phase Flow Transmission fluctuation Correlation Spectrum Energy and power
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
12
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy Photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
平抑风电波动的电-氢混合储能容量优化配置 被引量:4
13
作者 袁铁江 郭建华 +2 位作者 杨紫娟 冯亚杰 王进君 《中国电机工程学报》 EI CSCD 北大核心 2024年第4期1397-1405,I0012,共10页
针对电-氢混合系统协同平抑接入新型电力系统的新能源波动问题,提出考虑碱性电解槽运行特性的电-氢混合储能容量优化配置方案。首先,基于经验模态分解,将原始风电功率信号分解为符合波动量限值的直接并网分量和混合储能功率任务;在综合... 针对电-氢混合系统协同平抑接入新型电力系统的新能源波动问题,提出考虑碱性电解槽运行特性的电-氢混合储能容量优化配置方案。首先,基于经验模态分解,将原始风电功率信号分解为符合波动量限值的直接并网分量和混合储能功率任务;在综合考虑电化学储能和氢储能介质充放电功率约束和存储状态约束的基础上,制定计及碱性电解槽运行特性的混合储能能量管理策略。基于此策略,以综合成本最小为目标,建立用于平抑风电波动的电-氢混合储能容量配置模型,并通过实际数据进行计算分析。算例结果表明,所提策略下的容量配置方案,在满足平抑需求的前提下,可以有效提高系统经济性。 展开更多
关键词 氢储能 混合储能 波动平抑 能量管理策略
下载PDF
计及SOC自恢复的混合储能平抑风电功率波动控制 被引量:1
14
作者 林莉 林雨露 +3 位作者 谭惠丹 贾源琦 孔宪宇 曹雅裴 《电工技术学报》 EI CSCD 北大核心 2024年第3期658-671,共14页
混合储能系统能够较好地应对复杂的风电波动,有效地提高电网的稳定性和安全性。在混合储能平抑风电功率波动的典型应用场景下,该文首先提出一种计及荷电状态(SOC)自恢复的混合储能平抑风电功率波动控制方法,在满足风电平抑需求的情况下... 混合储能系统能够较好地应对复杂的风电波动,有效地提高电网的稳定性和安全性。在混合储能平抑风电功率波动的典型应用场景下,该文首先提出一种计及荷电状态(SOC)自恢复的混合储能平抑风电功率波动控制方法,在满足风电平抑需求的情况下,通过模型预测控制快速调节储能在平抑功率过程中的荷电状态,提高储能持续稳定运行能力;然后,为提高混合储能系统协调运行能力,设计了加权滑动平均(WMA)-模糊控制策略对超级电容和蓄电池功率进行动态分配;最后,结合实际风电功率数据,通过仿真验证了所提策略能有效平衡储能寿命和平抑风电波动的矛盾,能充分考虑两种储能设备的特性差异并提高功率分配的合理性。 展开更多
关键词 风电功率波动 混合储能 模型预测控制 加权滑动平均 模糊控制
下载PDF
光伏波动平抑下改进K-means的电池储能动态分组控制策略 被引量:1
15
作者 余洋 陆文韬 +3 位作者 陈东阳 刘霡 夏雨星 郑晓明 《电力系统保护与控制》 EI CSCD 北大核心 2024年第7期1-11,共11页
针对电池储能系统(battery energy storage system,BESS)进行光伏波动平抑时寿命损耗高及荷电状态(state of charge,SOC)一致性差的问题,提出了光伏波动平抑下改进K-means的BESS动态分组控制策略。首先,采用最小最大调度方法获取光伏并... 针对电池储能系统(battery energy storage system,BESS)进行光伏波动平抑时寿命损耗高及荷电状态(state of charge,SOC)一致性差的问题,提出了光伏波动平抑下改进K-means的BESS动态分组控制策略。首先,采用最小最大调度方法获取光伏并网指令。其次,设计了改进侏儒猫鼬优化算法(improved dwarf mongoose optimizer,IDMO),并利用它对传统K-means聚类算法进行改进,加快了聚类速度。接着,制定了电池单元动态分组原则,并根据电池单元SOC利用改进K-means将其分为3个电池组。然后,设计了基于充放电函数的电池单元SOC一致性功率分配方法,并据此提出BESS双层功率分配策略,上层确定电池组充放电顺序及指令,下层计算电池单元充放电指令。对所提策略进行仿真验证,结果表明,所设计的IDMO具有更高的寻优精度及更快的寻优速度。所提BESS平抑光伏波动策略在有效平抑波动的同时,降低了BESS运行寿命损耗并提高了电池单元SOC的均衡性。 展开更多
关键词 电池储能系统 波动平抑 功率分配 改进侏儒猫鼬优化算法 改进K-means聚类算法
下载PDF
平滑风电波动的飞轮协同电池混合储能系统经济性配置
16
作者 滕伟 许庆祥 +3 位作者 王亚军 秦润 武鑫 柳亦兵 《动力工程学报》 CAS CSCD 北大核心 2024年第7期1101-1108,共8页
针对风电场的有功功率波动,采用小波包分解的功率平抑算法,得到满足并网要求的低频信号分量和高频的混合储能系统参考功率,并使用低通滤波分频和信号平滑去噪方法获得飞轮储能和电池储能的参考信号,同时考虑放电深度和循环次数对电池储... 针对风电场的有功功率波动,采用小波包分解的功率平抑算法,得到满足并网要求的低频信号分量和高频的混合储能系统参考功率,并使用低通滤波分频和信号平滑去噪方法获得飞轮储能和电池储能的参考信号,同时考虑放电深度和循环次数对电池储能系统寿命的影响,构建混合储能系统在计划年限内的全生命周期经济性模型,采用多跟踪器优化算法(MTOA)得到最优的混合储能容量配置。最后,结合风电场实际功率数据,仿真分析验证混合储能系统对功率平抑的有效性和经济性。结果表明:混合储能系统既能保证风电场的有功功率波动满足并网要求,又能充分发挥不同储能形式特性,降低系统运行成本。 展开更多
关键词 有功功率波动 混合储能 容量配置 全生命周期经济性
下载PDF
基于二维动态减载和双层MPC的风储联合调频与功率优化分配
17
作者 朱瑛 石琦 +2 位作者 蔡寿国 卫志农 臧海祥 《电力自动化设备》 EI CSCD 北大核心 2024年第8期1-8,共8页
风机可以通过减载控制提供调频备用功率,但存在弃风量大的问题。为此,结合储能装置,设计了考虑风速分区与储能荷电状态(SOC)的二维动态减载策略,在提供充足调频备用功率的同时减小了弃风功率。在此基础上,结合双层模型预测控制(MPC)架构... 风机可以通过减载控制提供调频备用功率,但存在弃风量大的问题。为此,结合储能装置,设计了考虑风速分区与储能荷电状态(SOC)的二维动态减载策略,在提供充足调频备用功率的同时减小了弃风功率。在此基础上,结合双层模型预测控制(MPC)架构,提出了计及机组转矩波动的风储联合调频控制策略,上层MPC将风电场视作整体,通过协调风储出力提升调频效果;下层MPC通过风电场内的功率优化分配以抑制机组的转矩波动,保证调频性能的同时提高了机组运行稳定性。通过仿真分析验证了所提策略的有效性,结果表明该减载策略具有更高的风能利用率,且在调频过程中通过机组的功率优化分配减小了机组的转矩波动,提高了机组运行稳定性。 展开更多
关键词 动态减载 双层MPC 风储联合调频 有功功率分配 转矩波动
下载PDF
考虑生产安全的工业园区联络线功率平滑策略
18
作者 徐箭 余青芳 +2 位作者 廖思阳 柯德平 孙元章 《上海交通大学学报》 EI CAS CSCD 北大核心 2024年第6期941-953,共13页
高比例新能源接入工业园区已成为高耗能工业负荷低碳转型的主要途径,而联络线功率剧烈频繁波动是园区低碳转型的关键问题.因此,提出一种考虑生产安全的工业园区联络线功率平滑策略.首先,分析电解铝和矿热炉的可控设备控制模型,构建基于... 高比例新能源接入工业园区已成为高耗能工业负荷低碳转型的主要途径,而联络线功率剧烈频繁波动是园区低碳转型的关键问题.因此,提出一种考虑生产安全的工业园区联络线功率平滑策略.首先,分析电解铝和矿热炉的可控设备控制模型,构建基于联络线功率波动反馈的工业负荷功率闭环反馈控制模型.考虑工业生产核心影响因素,构建温度状态指标模型,形成考虑工业生产核心因素的典型工业负荷需求侧响应惩罚成本模型,并以工业生产的惩罚成本最小为优化目标,将控制目标分配至各工业负荷.最后,构建基于云南电网文山区域网架的MATLAB在线计算和RTDS仿真实时交互算例,结果表明,该算法自适应更新生产设备温度,有效降低功率调节对生产的影响,且联络线购电成本可降低36.4%. 展开更多
关键词 新能源功率波动平抑 高耗能工业负荷 生产安全边界 温度状态指标模型
下载PDF
周期性脉动源对风力机功率的影响
19
作者 李银然 杨博文 +2 位作者 赵峰 赵慧廷 李晔 《液压气动与密封》 2024年第2期10-14,共5页
针对WindPACT1.5 MW机组,通过大涡模拟探究风轮5°仰角时周期性脉动源(仰角、塔影效应、偏航、风剪切)对风力机总功率的影响,并结合逆叶素动量理论,进一步分析功率与升力系数之间的联系。结果表明,仰角、塔影效应加仰角与偏航加仰... 针对WindPACT1.5 MW机组,通过大涡模拟探究风轮5°仰角时周期性脉动源(仰角、塔影效应、偏航、风剪切)对风力机总功率的影响,并结合逆叶素动量理论,进一步分析功率与升力系数之间的联系。结果表明,仰角、塔影效应加仰角与偏航加仰角均使得风力机总功率产生“3P”的波动规律,而风剪切加仰角使得总功率产生“锯齿状”的高频率波动规律,其中偏航是总功率损失的主要因素,塔影效应是功率波动的主要因素,且发现升力系数波动规律与功率单周期内的波动规律相似。 展开更多
关键词 风力机 大涡模拟 周期性脉动源 功率波动 升力系数波动
下载PDF
带有指令滤波的电力弹簧系统反步控制
20
作者 杨成顺 韩通润 +2 位作者 许德智 戴宇辰 黄宵宁 《电力工程技术》 北大核心 2024年第2期105-112,共8页
针对新能源发电系统因间接性和不确定性导致的电压波动问题,文中首次将反步控制策略应用于电力弹簧(electric spring,ES)系统,并提出一种带有指令滤波的ES反步控制策略。根据ES的数学模型利用反步法设计控制器,并加入指令滤波器,以解决E... 针对新能源发电系统因间接性和不确定性导致的电压波动问题,文中首次将反步控制策略应用于电力弹簧(electric spring,ES)系统,并提出一种带有指令滤波的ES反步控制策略。根据ES的数学模型利用反步法设计控制器,并加入指令滤波器,以解决ES反步控制中的计算膨胀问题,同时设计误差补偿信号,并利用Lyapunov稳定性理论验证系统稳定性。通过仿真模拟新能源发电系统网侧电压波动时,ES对关键负载(critical load,CL)电压稳定的效果,以及不同系统参数对文中控制策略的敏感性分析。与传统的比例积分(proportional-integral,PI)控制对比,CL电压动态响应速度提高0.07 s,CL电压畸变率降低31%,参数敏感性分析中CL电压最大偏差率为0.318%,能承受的最大电压幅值波动范围提高52.9 V。仿真结果验证了文中所提出的控制策略具有响应速度快、谐波含量低、抗干扰能力强的优势。 展开更多
关键词 新能源发电系统 电力弹簧(ES) 指令滤波 反步控制 关键负载(CL) 电压波动 敏感性分析
下载PDF
上一页 1 2 83 下一页 到第
使用帮助 返回顶部