期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Hydrodynamics of gas-solid fluidization of a homogeneous ternary mixture in a conical bed:Prediction of bed expansion and bed fluctuation ratios 被引量:2
1
作者 D.T.K.Dora S.R.Panda +1 位作者 Y.K.Mohanty G.K.Roy 《Particuology》 SCIE EI CAS CSCD 2013年第6期681-688,共8页
Hydrodynamic characteristics of fluidization in a conical or tapered bed differ from those in a columnar bed because the superficial velocity in the bed varies in the axial direction. Fixed and fluidized regions could... Hydrodynamic characteristics of fluidization in a conical or tapered bed differ from those in a columnar bed because the superficial velocity in the bed varies in the axial direction. Fixed and fluidized regions could coexist and sharp variations in pressure drop could occur, thereby giving rise to a noticeable pressure drop-flow rate hysteresis loop under incipient fluidization conditions. To explore these unique properties, several experiments were carried out using homogeneous, well-mixed, ternary mixtures with three dif- ferent particle sizes at varying composition in gas-solid conical fluidized beds with varying cone angles. The hydrodynamic characteristics determined include the minimum fluidization velocity, bed fluctuation, and bed expansion ratios. The dependence of these quantities on average particle diameter, mass fraction of the fines in the mixture, initial static bed height, and cone angle is discussed. Based on dimensional analysis and factorial design, correlations are developed using the system parameters, i.e. geometry of the bed (cone angle), particle diameter, initial static bed height, density of the solid, and superficial velocity of the fluidizing medium. Experimental values of minimum fluidization velocity, bed fluctuation, and bed expansion ratios were found to agree well with the developed correlations. 展开更多
关键词 Gas-solid fluidization Conical bed Homogeneous ternary mixtures Bed fluctuation ratio Bed expansion ratio
原文传递
A detecting method for line-spectrum target by fusing output DC jump to fluctuations ratio of sub-band spatial spectrum and beam space 被引量:3
2
作者 DAI Wenshu CHEN Xinhua +1 位作者 SUN Changyu YU Huabing 《Chinese Journal of Acoustics》 CSCD 2015年第3期297-311,共15页
The low frequency line components of the radiated noise from an underwater target usually have both high spectrum level and sustained stability. This feature could be used to increase the detection performance of conv... The low frequency line components of the radiated noise from an underwater target usually have both high spectrum level and sustained stability. This feature could be used to increase the detection performance of conventional broadband energy integration method. The required spectrum level is theoretically discussed when the detection performance of the known line detection is better than that of broadband energy integration method. Under the condition of the target can be detected in line spectrum band, the relationship between the line spectrum level and signal to noise ratio (SNR) is also discussed. This paper proposes a line spectrum target detection method that a matrix using DC jump to fluctuations ratios of sub-band spatial spectrum and beam space output is constructed. This matrix acts as a filter that the line spectrum target with certain frequency and azimuth is passed at most. By fusing with the other sub band results, the conventional detection performance can be improved. At the same time, the applicable condition and detection performance are analyzed in the paper. The simulation and the sea trial data processing results show that the algorithm can effectively extract weak goal line spectrum target under the condition of multi-interference. The algorithm doesn't need multi-frame statistics and the detection performance is closer to the optimal line spectrum method. 展开更多
关键词 LINE than A detecting method for line-spectrum target by fusing output DC jump to fluctuations ratio of sub-band spatial spectrum and beam space DC
原文传递
Effect of promoters on dynamics of gas-solid fluidized bed——Statistical and ANN approaches
3
作者 Y.K. Mohanty K.C. Biswal +1 位作者 G.K. Roy B.P. Mohanty 《China Particuology》 SCIE EI CAS CSCD 2007年第6期401-407,共7页
In this study, a bubbling fluidized bed column, 99 mm in inside diameter and 960 mm in height, was used to investigate the effect of rod and disc promoters on fluctuation and expansion ratios. Factorial design (stati... In this study, a bubbling fluidized bed column, 99 mm in inside diameter and 960 mm in height, was used to investigate the effect of rod and disc promoters on fluctuation and expansion ratios. Factorial design (statistical approach) and artificial neural network (ANN) models were developed to predict the fluctuation and expansion ratios in this gas-solid fluidized bed with varying gas flow rates, bed heights, particle sizes and densities. The fluctuation and expansion predicted using these statistical and ANN models, for beds with and without promoters, were found to agree well with corresponding experiments. The statistical model was found to be superior to the ANN model due to its ability to take into account both individual and interactive effects. The rod promoters were found to be more effective in reducing bed fluctuation, and in increasing bed expansion at high gas mass velocities. 展开更多
关键词 Gas-solid fluidized bed fluctuation ratio Expansion ratio PROMOTER Factorial design Artificial neural network
原文传递
Experimental investigation into transient pressure pulses during pneumatic conveying of fine powders using Shannon entropy 被引量:3
4
作者 Amit Goel Anu Mittal +1 位作者 S.S. Mallick Atul Sharma 《Particuology》 SCIE EI CAS CSCD 2016年第6期143-153,共11页
This paper presents the results of an ongoing investigation into transient pressure pulses using Shan- non entropy. Pressure fluctuations (produced by gas-solid two-phase flow during fluidized dense-phase conveying)... This paper presents the results of an ongoing investigation into transient pressure pulses using Shan- non entropy. Pressure fluctuations (produced by gas-solid two-phase flow during fluidized dense-phase conveying) are recorded by pressure transducers installed at strategic locations along a pipeline. This work validates previous work on identifying the flow mode from pressure signals (Mittal, Mallick, & Wypych, 2014). Two different powders, namely fly ash (median particle diameter 45 μm, particle den- sity 1950 kg/m3. loosely poured bulk density 950 kg/m3) and cement (median particle diameter 15 p,m, particle density 3060 kg/m3, loosely poured bulk density 1070 kg/m3), are conveyed through different pipelines (51 mm I.D. × 70 m length and 63 mm I.D. × 24 m length). The transient nature of pressure fluc- tuations (instead of steady-state behavior) is considered in investigating flow characteristics. Shannon entropy is found to increase along straight pipe sections for both solids and both pipelines. However, Shannon entropy decreases after a bend. A comparison of Shannon entropy among different ranges of superficial air velocity reveals that high Shannon entropy corresponds to very low velocities (i.e. 3-5 m/s) and very high velocities (i.e. 11-14 m/s) while low Shannon entropy corresponds to mid-range velocities (i.e. 6-8 m/s). 展开更多
关键词 Transient pressure fluctuations Fluidized dense phase Shannon entropy Flow pattern Solid loading ratio Superficial air velocity
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部