With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in or...With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in order to meet the requirement of new emission standard, it's necessary to add flue gas desulfurization and denitration devices. In this paper, the choice of flue gas purification processes for CFB boiler has been discussed firstly, and then the economy and rationality of the SNCR + CFB-FGD + COA comprehensive solution to flue gas desulfurization and denitration have been analyzed.展开更多
With the revision of emission standards, deep desulphurization and DeNO X is needed in circulating fluidized bed (CFB) boilers. The operation of the first set of 300-MW CFB boiler plus limestone/gypsum wet flue gas de...With the revision of emission standards, deep desulphurization and DeNO X is needed in circulating fluidized bed (CFB) boilers. The operation of the first set of 300-MW CFB boiler plus limestone/gypsum wet flue gas desulphurization (FGD) system in the world shows that deep desulphurization and DeNO X of CFB boilers has higher SO2 removal efficiency at a lower Ca/S ratio compared with traditional inner desulphurization mode. It can meet the increasingly rigid emission standards, and is suitable for more fuels. Deep desulphurization and DeNO X can also achieve a highly-efficient high-temperature CFB boiler that can not only achieve inner desulphurization and low NO X emission, but benefits low-grade, high sulfur content fuels as well. Research of deep desulphurization and DeNO X will be a developing direction for CFB boilers.展开更多
Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat ab...Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat absorbed by the air heater is not sufficient. In Huaneng Dongfang Power Plant, the exhaust flue gas temperature is lowered through modifications to the economizer and the air heater. The experimental results reveal that every year, each boiler could save 3 850 tons of standard coal and reduce 85 tons of SO2 and 9 000 tons of CO2 respectively after retrofit.展开更多
基金Supported by the National High Technology Research and Develop-ment Program of China(863 Program)(2013AA065403)Major Sci-ence and Technology Project of Fujian Province,China(2011HZ0005-1)+1 种基金International Science and Technology CooperationProgram(2010DFB93990)Natural Science Foundation of FujianProvince,China(2014J06020)
文摘With the advantages of high combustion efficiency, wide fuel flexibility and low concentrations of discharged pollutants, circulating fluid- ized bed (CFB) boiler has been widely used in recent years. However, in order to meet the requirement of new emission standard, it's necessary to add flue gas desulfurization and denitration devices. In this paper, the choice of flue gas purification processes for CFB boiler has been discussed firstly, and then the economy and rationality of the SNCR + CFB-FGD + COA comprehensive solution to flue gas desulfurization and denitration have been analyzed.
文摘With the revision of emission standards, deep desulphurization and DeNO X is needed in circulating fluidized bed (CFB) boilers. The operation of the first set of 300-MW CFB boiler plus limestone/gypsum wet flue gas desulphurization (FGD) system in the world shows that deep desulphurization and DeNO X of CFB boilers has higher SO2 removal efficiency at a lower Ca/S ratio compared with traditional inner desulphurization mode. It can meet the increasingly rigid emission standards, and is suitable for more fuels. Deep desulphurization and DeNO X can also achieve a highly-efficient high-temperature CFB boiler that can not only achieve inner desulphurization and low NO X emission, but benefits low-grade, high sulfur content fuels as well. Research of deep desulphurization and DeNO X will be a developing direction for CFB boilers.
文摘Since the first batch of 350-MW supercritical utility boilers was put into operation, the exhaust flue gas temperature of the boilers has always been higher than the designed value. The main reason is that the heat absorbed by the air heater is not sufficient. In Huaneng Dongfang Power Plant, the exhaust flue gas temperature is lowered through modifications to the economizer and the air heater. The experimental results reveal that every year, each boiler could save 3 850 tons of standard coal and reduce 85 tons of SO2 and 9 000 tons of CO2 respectively after retrofit.