期刊文献+
共找到238篇文章
< 1 2 12 >
每页显示 20 50 100
Nitric oxide removal from flue gas coupled with the Fe^(Ⅱ)EDTA regeneration by ultraviolet irradiation
1
作者 Yuan Xu Ziwei Liu +5 位作者 Ying Dai Jinbo Ouyang Zhuyao Li Yuling Zhu Jianhua Ding Feiqiang He 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第4期133-143,共11页
During wet complexation denitrification of flue gas,Fe^(Ⅱ)EDTA regeneration,also known as reducing Fe^(Ⅱ)EDTA and Fe^(Ⅱ)EDTA-nitric oxide(NO)to Fe^(Ⅱ)EDTA,is crucial.In this paper,ultraviolet(UV)light was used for... During wet complexation denitrification of flue gas,Fe^(Ⅱ)EDTA regeneration,also known as reducing Fe^(Ⅱ)EDTA and Fe^(Ⅱ)EDTA-nitric oxide(NO)to Fe^(Ⅱ)EDTA,is crucial.In this paper,ultraviolet(UV)light was used for the first time to reduce Fe^(Ⅱ)EDTA-NO.The experimental result demonstrated that Fe^(Ⅱ)EDTA-NO reduction rate increased with UV power increasing,elevated temperature,and initial Fe^(Ⅱ)EDTA-NO concentration decreasing.Fe^(Ⅱ)EDTA-NO reduction rate increased first and then decreased as pH value increased(2.0-10.0).Fe^(Ⅱ)EDTA-NO reduction with UV irradiation presented a first order reaction with respect to Fe^(Ⅱ)EDTA-NO.Compared with other Fe^(Ⅱ)EDTA regeneration methods,Fe^(Ⅱ)EDTA regeneration with UV show more superiority through comprehensive consideration of regeneration rate and procedure.Subsequently,NO absorption experiment by Fe^(Ⅱ)EDTA solution with UV irradiation confirmed that UV can significantly promote the NO removal performance of Fe^(Ⅱ)EDTA.Appropriate oxygen concentration(3%(vol))and acidic environment(pH=4)was favorable for NO removal.With UV power increasing as well as temperature decreasing,NO removal efficiency rose.In addition,the mechanism research indicates that NO from flue gas is mostly converted to NO_(2)-,NO_(3)-,NH_(4)^(+),N_(2),and N_(2)O with Fe^(Ⅱ)EDTA absorption liquid with UV irradiation.UV strengthens NO removal in Fe^(Ⅱ)EDTA absorption liquid by forming a synergistic effect of oxidation-reduction-complexation.Finally,compared with NO removal methods with Fe^(Ⅱ)EDTA,Fe^(Ⅱ)EDTA combined UV system shows prominent technology advantage in terms of economy and secondary pollution. 展开更多
关键词 Fe^(II)EDTA ULTRAVIOLET flue gas Nitric oxide REGENERATION Absorption
下载PDF
Preparation of α-High Strength Gypsum from Flue Gas Desulfurization Gypsum Pretreated by Hydrothermal-aging Method
2
作者 苏一鑫 GAO Lili +3 位作者 陈学青 LI Zhishui 李雲 CAO Jilin 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS CSCD 2024年第1期75-81,共7页
The synthesis of α-calcium sulfate hemihydrate (α-CSH) from flue gas desulfurization (FGD)gypsum is a good way to realize the comprehensive utilization of FGD gypsum. To obtainα-CSH with the satisfactory performanc... The synthesis of α-calcium sulfate hemihydrate (α-CSH) from flue gas desulfurization (FGD)gypsum is a good way to realize the comprehensive utilization of FGD gypsum. To obtainα-CSH with the satisfactory performances, a facile hydrothermal-aging pretreatment process for FGD gypsum raw materials was proposed, where FGD gypsum was firstly hydrothermally converted to α-CSH whiskers, and α-CSH whiskers were further hydrated to synthesize CaSO4·2H2O (CSD) by aging under the regulation of N,N'-methylenebisacrylamide (MBA). The effects of aging time, MBA addition, aging temperature, and pH on the morphology of the synthesized CSD were investigated. The synthesized CSD crystals exhibit highly uniform prismatic morphology with the length of ca 100μm and the whiteness of 91.56%. The regulation mechanism of MBA was also illustrated. The synthesized CSD crystals with prismatic morphology were further used as raw materials to synthesize the short columnar α-CSH. The absolute dry compressive strength of paste prepared from the short columnar α-CSH is 40.85 MPa, which reaches α40 strength grade. 展开更多
关键词 flue gas desulphurization gypsum α-calcium sulfate hemihydrate hydrothermal-aging method N N'-methylenebisacrylamide prismatic CSD
下载PDF
Effect of integration of mechanical ball milling and flue gas desulfurization gypsum on dealkalization of bauxite residue
3
作者 Feng ZHU Xu-yao GUO +6 位作者 Jun JIANG Kai-bin CHEN Xuan-zhi ZHU Dan-dan DENG Yu-jun WU Yu-wei HUANG Sheng-guo XUE 《Transactions of Nonferrous Metals Society of China》 SCIE EI CAS CSCD 2024年第8期2702-2713,共12页
The synergistic impact of mechanical ball milling and flue gas desulfurization(FGD)gypsum on the dealkalization of bauxite residue was investigated through integrated analyses of solution chemistry,mineralogy,and micr... The synergistic impact of mechanical ball milling and flue gas desulfurization(FGD)gypsum on the dealkalization of bauxite residue was investigated through integrated analyses of solution chemistry,mineralogy,and microtopography.The results showed a significant decrease in Na_(2)O content(>30 wt.%)of FGD gypsum-treated bauxite residue after 30 min of mechanical ball milling.Mechanical ball milling resulted in differentiation of the elemental distribution,modification of the minerals in crystalline structure,and promotion in the dissolution of alkaline minerals,thus enhancing the acid neutralization capacity of bauxite residue.5 wt.%FGD gypsum combined with 30 min mechanical ball milling was optimal for the dealkalization of bauxite residue. 展开更多
关键词 bauxite residue alkalinity regulation flue gas desulfurization gypsum mechanical activation soil formation of bauxite residue
下载PDF
Study of the reaction mechanism for preparing powdered activated coke with SO_(2)adsorption capability via one-step rapid activation method under flue gas atmosphere
4
作者 Binxuan Zhou Jingcai Chang +5 位作者 Jun Li Jinglan Hong Tao Wang Liqiang Zhang Ping Zhou Chunyuan Ma 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第1期158-168,共11页
In this study,the impact of different reaction times on the preparation of powdered activated carbon(PAC)using a one-step rapid activation method under flue gas atmosphere is investigated,and the underlying reaction m... In this study,the impact of different reaction times on the preparation of powdered activated carbon(PAC)using a one-step rapid activation method under flue gas atmosphere is investigated,and the underlying reaction mechanism is summarized.Results indicate that the reaction process of this method can be divided into three stages:stage I is the rapid release of volatiles and the rapid consumption of O_(2),primarily occurring within a reaction time range of 0-0.5 s;stage II is mainly the continuous release and diffusion of volatiles,which is the carbonization and activation coupling reaction stage,and the carbonization process is the main in this stage.This stage mainly occurs at the reaction time range of 0.5 -2.0 s when SL-coal is used as material,and that is 0.5-3.0 s when JJ-coal is used as material;stage III is mainly the activation stage,during which activated components diffuse to both the surface and interior of particles.This stage mainly involves the reaction stage of CO_(2)and H2O(g)activation,and it mainly occurs at the reaction time range of 2.0-4.0 s when SL-coal is used as material,and that is 3.0-4.0 s when JJ-coal is used as material.Besides,the main function of the first two stages is to provide more diffusion channels and contact surfaces/activation sites for the diffusion and activation of the activated components in the third stage.Mastering the reaction mechanism would serve as a crucial reference and foundation for designing the structure,size of the reactor,and optimal positioning of the activator nozzle in PAC preparation. 展开更多
关键词 Reaction mechanism Powdered activated coke preparation SO_(2)adsorption One-step rapid activation flue gas atmosphere
下载PDF
Miscibility of light oil and flue gas under thermal action
5
作者 XI Changfeng WANG Bojun +7 位作者 ZHAO Fang HUA Daode QI Zongyao LIU Tong ZHAO Zeqi TANG Junshi ZHOU You WANG Hongzhuang 《Petroleum Exploration and Development》 SCIE 2024年第1期164-171,共8页
The miscibility of flue gas and different types of light oils is investigated through slender-tube miscible displacement experiment at high temperature and high pressure.Under the conditions of high temperature and hi... The miscibility of flue gas and different types of light oils is investigated through slender-tube miscible displacement experiment at high temperature and high pressure.Under the conditions of high temperature and high pressure,the miscible displacement of flue gas and light oil is possible.At the same temperature,there is a linear relationship between oil displacement efficiency and pressure.At the same pressure,the oil displacement efficiency increases gently and then rapidly to more than 90% to achieve miscible displacement with the increase of temperature.The rapid increase of oil displacement efficiency is closely related to the process that the light components of oil transit in phase state due to distillation with the rise of temperature.Moreover,at the same pressure,the lighter the oil,the lower the minimum miscibility temperature between flue gas and oil,which allows easier miscibility and ultimately better performance of thermal miscible flooding by air injection.The miscibility between flue gas and light oil at high temperature and high pressure is more typically characterized by phase transition at high temperature in supercritical state,and it is different from the contact extraction miscibility of CO_(2) under conventional high pressure conditions. 展开更多
关键词 light oil flue gas flooding thermal miscible flooding miscible law distillation phase transition minimum miscible pressure minimum miscible temperature
下载PDF
Improvement of High-efficiency Green Catalysts for Flue Gas Denitrification
6
作者 Liyan JIN Qingyi YU +3 位作者 Naixin ZHANG Yu WEI Xinlu YANG Yu GAO 《Meteorological and Environmental Research》 2024年第4期49-51,共3页
Based on the basic principle and mechanism of flue gas denitrification,the commonly used catalysts for flue gas denitrification were introduced firstly,and then the catalytic performance,stability and reaction mechani... Based on the basic principle and mechanism of flue gas denitrification,the commonly used catalysts for flue gas denitrification were introduced firstly,and then the catalytic performance,stability and reaction mechanism of catalysts in the market were analyzed.Different types of catalysts were studied to look for green catalysts with high activity,sulfur resistance,water vapor resistance and other advantages.The mechanism of denitration reaction of green catalysts was discussed,and the laws of formation,propagation and consumption of active species in the reaction process were revealed to provide theoretical basis for optimizing catalyst design and improving reaction conditions.Then the research status and problems of new catalysts for flue gas denitrification were described.Finally,the future development direction of green catalysts for flue gas denitration was discussed to improve the performance and stability of catalysts and meet the performance requirements of denitration catalysts in different industries. 展开更多
关键词 flue gas denitration Green catalyst Denitration catalyst ACTIVITY Selective catalytic reduction Catalyst activation
下载PDF
Multiobjective economic model predictive control using utopia-tracking for the wet flue gas desulphurization system 被引量:1
7
作者 Shan Liu Wenqi Zhong +2 位作者 Xi Chen Li Sun Lukuan Yang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2023年第2期343-352,共10页
Efficient control of the desulphurization system is challenging in maximizing the economic objective while reducing the SO_(2) emission concentration. The conventional optimization method is generally based on a hiera... Efficient control of the desulphurization system is challenging in maximizing the economic objective while reducing the SO_(2) emission concentration. The conventional optimization method is generally based on a hierarchical structure in which the upper optimization layer calculates the steady-state results and the lower control layer is responsible to drive the process to the target point. However, the conventional hierarchical structure does not take the economic performance of the dynamic tracking process into account. To this end, multi-objective economic model predictive control(MOEMPC) is introduced in this paper, which unifies the optimization and control layers in a single stage. The objective functions are formulated in terms of a dynamic horizon and to balance the stability and economic performance. In the MOEMPC scheme, economic performance and SO_(2) emission performance are guaranteed by tracking a set of utopia points during dynamic transitions. The terminal penalty function and stabilizing constraint conditions are designed to ensure the stability of the system. Finally, an optimized control method for the stable operation of the complex desulfurization system has been established. Simulation results demonstrate that MOEMPC is superior over another control strategy in terms of economic performance and emission reduction, especially when the desulphurization system suffers from frequent flue gas disturbances. 展开更多
关键词 Desulphurization system Economics Economic model predictive control flue gas Optimization Utopia point
下载PDF
Effect of steam spraying on a sintering bed on sinter quality and the emission of flue gas pollutants
8
作者 QI Yilong WU Hongliang +3 位作者 YU Zhengwei LONG Hongming WU Zhiyong WANG Wen 《Baosteel Technical Research》 CAS 2023年第2期37-46,共10页
The technology for spraying a sintering bed and thus improving sinter quality indicators while reducing the emission of flue gas pollutants has recently become an important research topic.The impacts on sinter quality... The technology for spraying a sintering bed and thus improving sinter quality indicators while reducing the emission of flue gas pollutants has recently become an important research topic.The impacts on sinter quality and emissions when spraying the sintering surface with different amounts and flow rates of steam were investigated in this study.The sinter quality indicators were most effectively improved by spraying 180 g of steam flow continuously at a rate of 0.02 m^(3)/min for 15 min after ignition for 8 min.The optimal effect on emission reduction was obtained by spraying 90 g of steam flow continuously at a rate of 0.01 m^(3)/min for 15 min after ignition for 8 min. 展开更多
关键词 SINTERING steam spraying emission reduction flue gas pollutants
下载PDF
In-situ measurement and distribution of flue gas mercury for a utility PC boiler system 被引量:3
9
作者 段钰锋 Cao Yan +3 位作者 Shawn Kellie Kunlei Liu John Riley Weiping Pan 《Journal of Southeast University(English Edition)》 EI CAS 2005年第1期53-57,共5页
The in-situ instrumentation technique for measuring mercury and itsspeciation downstream a utility 100 MW pulverized coal (PC) fired boiler system was developed andconducted by the use of the Ontario hydro method (OHM... The in-situ instrumentation technique for measuring mercury and itsspeciation downstream a utility 100 MW pulverized coal (PC) fired boiler system was developed andconducted by the use of the Ontario hydro method (OHM) consistent with American standard test methodtogether with the semi-continuous emissions monitoring (SCEM) system as well as a mobile laboratoryfor mercury monitoring. The mercury and its speciation concentrations including participate mercuryat three locations of before air preheater, before electrostatic precipitator (ESP) and after ESPwere measured using the OHM and SCEM methods under normal operation conditions of the boiler systemas a result of firing a bituminous coal. The vapor-phase total mercury Hg(VT) concentration declinedwith the decrease of flue gas temperature because of mercury species transformation from oxidizedmercury to particulate mercury as the flue gas moved downstream from the air preheater to the ESPand after the ESP. A good agreement for Hg°, Hg^(2+) and Hg( VT) was obtained between the twomethods in the ash-free area. But in the dense particle-laden flue gas area, there appeared to be abig bias for mercury speciation owing to dust cake formed in the filter of OHM sampling probe. Theparticulateaffinity to the flue gas mercury and the impacts of sampling condition to accuracy ofmeasure were discussed. 展开更多
关键词 coal fired flue gas mercury speciation in-situ measurement Ontario hydromethod (OHM) semi-continuous emissions monitoring (SCEM)
下载PDF
Experimental Studies on a Circulating Fluidized Bed for Flue Gas Desulfurization
10
作者 吴颖海 王文梁 +2 位作者 黄震 李大骥 肖艳艳 《Journal of Southeast University(English Edition)》 EI CAS 1998年第1期64-68,共5页
The tests of flue gas desulfurization were carried out on a circulating fluidized bed reactor in which the flue gas had different velocities at different sections. The SO 2 removal efficiency could be as high as 80% ... The tests of flue gas desulfurization were carried out on a circulating fluidized bed reactor in which the flue gas had different velocities at different sections. The SO 2 removal efficiency could be as high as 80% when Ca/S molar ratio was 1 1 and a small amount of water was sprayed into the reactor by a two phase (gas liquid) system nozzle. 展开更多
关键词 CIRCULATING fluidized bed flue gas desulfurization
下载PDF
Study on Curing Effect and the Waste Heat Recovering Equipment Design of Flue Gas of Bulk Curing Barn 被引量:3
11
作者 刘大双 徐增汉 +6 位作者 宋泽民 杨晔 马建彬 肖振杰 刘瑞峰 葛永琴 邹敏杰 《Agricultural Science & Technology》 CAS 2015年第12期2801-2804,共4页
In order to realize tobacco curing with energy saving and emission reduc- ing and lower cost, the waste heat recovering equipment was designed and built on blowing-upward type bulk curing barn. The comparative experim... In order to realize tobacco curing with energy saving and emission reduc- ing and lower cost, the waste heat recovering equipment was designed and built on blowing-upward type bulk curing barn. The comparative experiment of tobacco leaf curing was conducted between a bulk curing barn with waste heat of flue gas and conventional bulk curing barn. The results showed that the effect of saving coal in bulk curing barn with waste heat of flue gas was obvious than the contrast. The coal consumption quantity was 1.531 kg per kg of dry tobacco leaf. The saving coal in bulk curing barn with use waste heat of flue gas was 0.181 kg per kg of dry tobacco leaf than the contrast and saving coal rate was 10.57%. The electricity consumption quantity was 0.593 kWh per kg of dry tobacco leaf. The saving elec- tricity quantity in bulk curing barn with use waste heat of flue gas was 0.022 kWh/kg and the saving electricity rate was 3.58% than the contrast. The saving curing cost was 0.158 yuan per kg of dry tobacco leaf and saving cost rate 9.09% in bulk cur- ing barn with use waste heat of flue gas than the contrast. The appearance quality, grade structure and primary chemical composition had no significant difference be- tween bulk curing barn with use waste heat of flue gas and the contrast. 展开更多
关键词 Bulk curing barn Waste heat recovering equipment of flue gas Tobacco leaf Cudng effect
下载PDF
Simultaneous desulfurization and denitrification of sintering flue gas via composite absorbent 被引量:27
12
作者 Jie Wang Wenqi Zhong 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第8期1104-1111,共8页
Experiments on simultaneous absorption of SO_2 and NO_X from sintering flue gas via a composite absorbent NaClO_2/NaClO were carried out. The effects of various operating parameters such as NaClO_2 concentration(ms), ... Experiments on simultaneous absorption of SO_2 and NO_X from sintering flue gas via a composite absorbent NaClO_2/NaClO were carried out. The effects of various operating parameters such as NaClO_2 concentration(ms), NaClO concentration(mp), molar ratio of NaClO_2/NaClO(M), solution temperature(TR), initial solution pH, gas flow(Vg) and inlet concentration of SO_2(CS) and NO(CN) on the removal efficiencies of SO_2 and NO were discussed. The optimal experimental conditions were determined to be initial solution pH = 6, TR=55 °C and M = 1.3 under which the average efficiencies of desulfurization and denitrification could reach99.7% and 90.8%, respectively. Moreover, according to the analysis of reaction products, it was found that adding NaClO to NaClO_2 aqueous solution is favorable for the generation of ClO_2 and Cl_2 which have significant effect on desulfurization and denitrification. Finally, engineering experiments were performed and obtained good results demonstrating that this method is practicable and promising. 展开更多
关键词 Simultaneous DESULFURIZATION and DENITRIFICATION SINTERING flue gas COMPOSITE ABSORBENT
下载PDF
Study on the removal of NO_x from simulated flue gas using acidic NaClO_2 solution 被引量:40
13
作者 Bal Rai Deshwal Si Hyun Lee +2 位作者 Jong Hyeon Jung Byung Hyun Shon Hyung Keun Lee 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2008年第1期33-38,共6页
The study on the removal of NOx from simulated flue gas has been carded out in a lab-scale bubbling reactor using acidic solutions of sodium chlorite. Experiments were performed at various pH values and inlet NO conce... The study on the removal of NOx from simulated flue gas has been carded out in a lab-scale bubbling reactor using acidic solutions of sodium chlorite. Experiments were performed at various pH values and inlet NO concentrations in the absence or presence of SO2 gas at 45℃. The effect of SO2 on NO oxidation and NO2 absorption was critically examined. The oxidative ability of sodium chlorite was investigated at different pH values and it was found to be a better oxidant at a pH less than 4. In acidic medium, sodium chlorite decomposed into C102 gas, which is believed to participate in NO oxidation as well as in NO2 absorption. A plausible NOx removal mechanism using acidic sodium chlorite solution has been postulated. A maximum NOx removal efficiency of about 81% has been achieved. 展开更多
关键词 bubbling reactor acidic sodium chlorite flue gas NOx removal
下载PDF
Experimental and mechanism studies on seawater flue gas desulfurization 被引量:18
14
作者 ZHAOYi WANGXiao-ming 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2003年第1期123-128,共6页
Seawater flue gas desulfurization (Seawater FGD) process has a number of advantages, but the study on mechanism of seawater FGD is little. The effects of absorbing efficiency of SO 2 by the constant component and par... Seawater flue gas desulfurization (Seawater FGD) process has a number of advantages, but the study on mechanism of seawater FGD is little. The effects of absorbing efficiency of SO 2 by the constant component and part of trace transition elements in seawater are studied by the experiment. The results indicate that the effect factors of absorption of SO 2 by seawater are alkaline, ion intensity, catalysis of Cl - and transition metal ions Fe 2+ , Mn 2+ . The degree of effect is alkaline > the catalysis of Cl -, Fe 2+ and Mn 2+ >ion intensity. The mechanisms of catalysis oxidation for S(IV) by Cl -, Fe 2+ and Mn 2+ are discussed. According to the results, some measures can be used to improve the capability of desulfurization. 展开更多
关键词 seawater flue gas desulfurization CATALYSIS
下载PDF
Clathrate Hydrate Capture of CO2 from Simulated Flue Gas with Cyclopentane/Water Emulsion 被引量:11
15
作者 李士凤 樊栓狮 +2 位作者 王金渠 郎雪梅 王燕鸿 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2010年第2期202-206,共5页
Capture of CO2 by hydrate is one of the attractive technologies for reducing greenhouse effect.The primary challenges are the large energy consumption,low hydrate formation rate and separation efficiency.This work pre... Capture of CO2 by hydrate is one of the attractive technologies for reducing greenhouse effect.The primary challenges are the large energy consumption,low hydrate formation rate and separation efficiency.This work presents a new method for capture of CO2 from simulated flue gasCO2(16.60%,by mole) /N2 binary mixture by formation of cyclopentane(CP) hydrates at initial temperature of 8.1°C with the feed pressures from 2.49 to 3.95 MPa.The effect of cyclopentane and cyclopentane/water emulsion on the hydrate formation rate and CO2 separation efficiency was studied in a 1000 ml stirred reactor.The results showed the hydrate formation rate could be increased remarkably with cyclopentane/water emulsion.CO2 could be enriched to 43.97%(by mole) and 35.29%(by mole) from simulated flue gas with cyclopentane and cyclopentane/water(O/W) emulsion,respectively,by one stage hydrate separation under low feed pressure.CO2 separation factor with cyclopentane was 6.18,higher than that with cyclopentane/water emulsion(4.01) ,in the range of the feed pressure.The results demonstrated that cyclopentane/water emulsion is a good additive for efficient hydrate capture of CO2. 展开更多
关键词 CYCLOPENTANE HYDRATE CO2 capture EMULSION flue gas
下载PDF
Transformation of Flue-Gas-Desulfurization Gypsum to α-Hemihydrated Gypsum in Salt Solution at Atmospheric Pressure 被引量:18
16
作者 吴晓琴 童仕唐 +1 位作者 官宝红 吴忠标 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第2期349-355,共7页
Direct phase transformation of flue gas desulfurization gypsum in hot salt solution at atmospheric pres-sure was investigated.The effects of temperature,salt species,salt concentration,solids content,pH and modifier w... Direct phase transformation of flue gas desulfurization gypsum in hot salt solution at atmospheric pres-sure was investigated.The effects of temperature,salt species,salt concentration,solids content,pH and modifier were examined.The crystals obtained under different conditions and solubility of calcium sulfate in contact with solid gypsum were also determined.α-Calcium sulfate hemihydrate crystals of stubby columnar shape and regular pentahedral sides were obtained under the following conditions:salt concentration 20%-30%,operation tempera-ture 95-100 °C,solids mass content in the slurry 10%-30% and neutral pH.Thermodynamic analysis revealed that phase transformation of calcium sulfate dihydrate to α-calcium sulfate hemihydrate occurs because of the difference in solubilities between the two solid gypsum phases in this system. 展开更多
关键词 flue gas desulfurization gypsum crystal growth thermogravimetric analysis phase transformation
下载PDF
A novel carbon trap sampling system for coal-fired flue gas mercury measurement
17
作者 汤红健 段钰锋 +3 位作者 朱纯 周强 佘敏 蔡亮 《Journal of Southeast University(English Edition)》 EI CAS 2015年第2期244-248,共5页
A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring parti... A novel carbon trap sampling system for gas-phase mercury measurement in flue gas is developed, including the high efficient sorbents made of modified biomass cokes and high precision sorbent traps for measuring particle-bound and total vapor-phase mercury in flue gas. A dedusting device is installed to collect fine fly ash for reducing the measurement errors. The thorough comparison test of mercury concentration in flue gas is conducted between the novel sampling system and the Ontario hydro method (OHM) in a 6 kW circulating fluidized bed combustor. Mercury mass balance rates of the OHM range from 95.47% to 104.72%. The mercury breakthrough rates for the second section of the sorbent trap are all below 2%. The relative deviations in the two test cases are in the range of 15. 96% to 17. 56% under different conditions. The verified data suggest that this novel carbon trap sampling system can meet the standards of quality assurance and quality control required by EPA Method 30B and can be applied to the coal-fired flue gas mercury sampling system. 展开更多
关键词 mercury sorbent trap coal-fired flue gas mercury sampling unit
下载PDF
Hydrate capture CO_2 from shifted synthesis gas, flue gas and sour natural gas or biogas 被引量:10
18
作者 Yanhong Wang Xuemei Lang Shuanshi Fan 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2013年第1期39-47,共9页
CO2 capture by hydrate formation is a novel gas separation technology, by which CO2 is selectively engaged in the cages of hydrate and is separated with other gases, based on the differences of phase equilibrium for C... CO2 capture by hydrate formation is a novel gas separation technology, by which CO2 is selectively engaged in the cages of hydrate and is separated with other gases, based on the differences of phase equilibrium for CO2 and other gases. However. rigorous temperature and pressure, high energy cost and industrialized hydration separator dragged the development of the hydrate based CO2 capture. In this paper, the key problems in CO2 capture from the different sources such as shifted synthesis gas, flue gas and sour natural gas or biogas were analyzed. For shifted synthesis gas and flue gas, its high energy consumption is the barrier, and for the sour natural gas or biogas (CO2/CH4 system), the bottleneck is how to enhance the selectivity of CO2 hydration. For these gases, scale-up is the main difficulty. Also, this paper explored the possibility of separating different gases by selective hydrate formation and reviewed the progress of CO2 separation from shifted synthesis gas, flue gas and sour natural gas or biogas. 展开更多
关键词 clathrate hydrate: C02 capture hydrogen shifted synthesis gas flue gas sour natural gas or biogas
下载PDF
Economic Comparison of Three Gas Separation Technologies for CO2 Capture from Power Plant Flue Gas 被引量:8
19
作者 YANG Hongjun FAN Shuanshi LANG Xuemei WANG Yanhong NIE Jianghua 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2011年第4期615-620,共6页
Three gas separation technologies,chemical absorption,membrane separation and pressure swing adsorption,are usually applied for CO2 capture from flue gas in coal-fired power plants.In this work,the costs of the three ... Three gas separation technologies,chemical absorption,membrane separation and pressure swing adsorption,are usually applied for CO2 capture from flue gas in coal-fired power plants.In this work,the costs of the three technologies are analyzed and compared.The cost for chemical absorption is mainly from $30 to $60 per ton(based on CO2 avoided),while the minimum value is $10 per ton(based on CO2 avoided).As for membrane separation and pressure swing adsorption,the costs are $50 to $78 and $40 to $63 per ton(based on CO2 avoided),respectively.Measures are proposed to reduce the cost of the three technologies.For CO2 capture and storage process,the CO2 recovery and purity should be greater than 90%.Based on the cost,recovery,and purity,it seems that chemical absorption is currently the most cost-effective technology for CO2 capture from flue gas from power plants.However,membrane gas separation is the most promising alternative approach in the future,provided that membrane performance is further improved. 展开更多
关键词 CO2 capture cost flue gas chemical absorption membrane gas separation pressure swing adsorption
下载PDF
Combustion behavior and influence mechanism of CO on iron ore sintering with flue gas recirculation 被引量:9
20
作者 范晓慧 余志元 +2 位作者 甘敏 陈许玲 季志云 《Journal of Central South University》 SCIE EI CAS 2014年第6期2391-2396,共6页
The properties of circulating gas have a significant effect on sintering with flue gas recirculation,and the influence of CO in sintering process was investigated.The results show that the post-combustion of CO conduc... The properties of circulating gas have a significant effect on sintering with flue gas recirculation,and the influence of CO in sintering process was investigated.The results show that the post-combustion of CO conducts in sinter zone when flue gas passes through the sintering bed,which releases much heat and reduces the consumption of solid fuel.The ratio of coke breeze can be reduced from 5% to 4.7% with 2% CO in circulating flue gas.In addition,with the increase of CO content in circulating flue gas,the combustion efficiency of fuel is improved,and the flame front is increased slightly while still matches with the heat transfer front.These are beneficial to increasing the maximum temperature and prolonging the high temperature duration,especially in the upper layer of sintering bed.As a consequence,the productivity,vertical sintering velocity and quality of sinter are improved. 展开更多
关键词 flue gas recirculation heat transfer front flame front combustion behavior
下载PDF
上一页 1 2 12 下一页 到第
使用帮助 返回顶部