期刊文献+
共找到59,508篇文章
< 1 2 250 >
每页显示 20 50 100
NIR-II fluorescence imaging in liver tumor surgery: A narrative review
1
作者 Zihao Liu Lifeng Yan +1 位作者 Qingsong Hu Dalong Yin 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期29-44,共16页
In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpat... In liver tumor surgery,the recognition of tumor margin and radical resection of microcancer focis have always been the crucial points to reduce postoperative recurrence of tumor.However,naked-eye inspection and palpation have limited effectiveness in identifying tumor boundaries,and traditional imaging techniques cannot consistently locate tumors in real time.As an intraoperative real-time navigation imaging method,NIRfluorescence imaging has been extensively studied for its simplicity,reliable safety,and superior sensitivity,and is expected to improve the accuracy of liver tumor surgery.In recent years,the research focus of NIRfluorescence has gradually shifted from the-rst near-infrared window(NIR-I,700–900 nm)to the second near-infrared window(NIR-II,1000–1700 nm).Fluorescence imaging in NIR-II reduces the scattering effect of deep tissue,providing a preferable detection depth and spatial resolution while signi-cantly eliminating liver autofluorescence background to clarify tumor margin.Developingfluorophores combined with tumor antibodies will further improve the precision offluorescence-guided surgical navigation.With the development of a bunch offluorophores with phototherapy ability,NIR-II can integrate tumor detection and treatment to explore a new therapeutic strategy for liver cancer.Here,we review the recent progress of NIR-IIfluorescence technology in liver tumor surgery and discuss its challenges and potential development direction. 展开更多
关键词 fluorescence guided-surgery liver cancer near infrared-II optical imaging
下载PDF
Self-confocal NIR-II fluorescence microscopy for multifunctional in vivo imaging
2
作者 Jing Zhou Tianxiang Wu +5 位作者 Runze Chen Liang Zhu Hequn Zhang Yifei Li Liying Chen Jun Qian 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期105-119,共15页
Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imagi... Fluorescence imaging in the second near-infrared window(NIR-II,900–1880 nm)with less scattering background in biological tissues has been combined with the confocal microscopic system for achieving deep in vivo imaging with high spatial resolution.However,the traditional NIR-IIfluorescence confocal microscope with separate excitation focus and detection pinhole makes it possess low confocal e±ciency,as well as di±cultly to adjust.Two types of upgraded NIR-IIfluorescence confocal microscopes,sharing the same pinhole by excitation and emission focus,leading to higher confocal e±ciency,are built in this work.One type is-ber-pinhole-based confocal microscope applicable to CW laser excitation.It is constructed forfluorescence intensity imaging with large depth,high stabilization and low cost,which could replace multiphotonfluorescence microscopy in some applications(e.g.,cerebrovascular and hepatocellular imaging).The other type is air-pinhole-based confocal microscope applicable to femtosecond(fs)laser excitation.It can be employed not only for NIR-IIfluorescence intensity imaging,but also for multi-channelfluorescence lifetime imaging to recognize different structures with similarfluorescence spectrum.Moreover,it can be facilely combined with multiphotonfluorescence microscopy.A single fs pulsed laser is utilized to achieve up-conversion(visible multiphotonfluorescence)and down-conversion(NIR-II one-photonfluorescence)excitation simultaneously,extending imaging spectral channels,and thus facilitates multi-structure and multi-functional observation. 展开更多
关键词 Self-confocal fiber-pinhole air-pinhole multi-channe fluorescence lifetime imaging multi-color imaging
下载PDF
Research on a deconvolution algorithm for laser-induced fluorescence diagnosis based on the maximum entropy principle
3
作者 雷清雲 杨雄 +4 位作者 程谋森 张帆 郭大伟 李小康 肖文杰 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第7期93-107,共15页
Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvol... Laser-induced fluorescence(LIF)spectroscopy is employed for plasma diagnosis,necessitating the utilization of deconvolution algorithms to isolate the Doppler effect from the raw spectral signal.However,direct deconvolution becomes invalid in the presence of noise as it leads to infinite amplification of high-frequency noise components.To address this issue,we propose a deconvolution algorithm based on the maximum entropy principle.We validate the effectiveness of the proposed algorithm by utilizing simulated LIF spectra at various noise levels(signal-to-noise ratio,SNR=20–80 d B)and measured LIF spectra with Xe as the working fluid.In the typical measured spectrum(SNR=26.23 d B)experiment,compared with the Gaussian filter and the Richardson–Lucy(R-L)algorithm,the proposed algorithm demonstrates an increase in SNR of 1.39 d B and 4.66 d B,respectively,along with a reduction in the root-meansquare error(RMSE)of 35%and 64%,respectively.Additionally,there is a decrease in the spectral angle(SA)of 0.05 and 0.11,respectively.In the high-quality spectrum(SNR=43.96 d B)experiment,the results show that the running time of the proposed algorithm is reduced by about98%compared with the R-L iterative algorithm.Moreover,the maximum entropy algorithm avoids parameter optimization settings and is more suitable for automatic implementation.In conclusion,the proposed algorithm can accurately resolve Doppler spectrum details while effectively suppressing noise,thus highlighting its advantage in LIF spectral deconvolution applications. 展开更多
关键词 maximum entropy spectral deconvolution laser-induced fluorescence spectrum
下载PDF
Near-Infrared Fluorescence Imaging Contrast Agents for Clinical Research: Limitations and Alternatives
4
作者 Serigne Moussa Badiane Elhadji A. L. Bathily +1 位作者 Fawrou Seye Louis A.D. Diouf 《Open Journal of Biophysics》 2024年第1期73-77,共5页
Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical... Introduction: Near-infrared fluorescence imaging is a technique that will establish itself in the short term at the international level because it is recognized for its potential to improve the performance of surgical interventions, its moderate investment and operating costs and its portability. Although the technology is now mature, there is currently the problem of the availability of contrast agents to be injected IV. The aim of this methodology article is to propose an alternative solution to the need for contrast agents for clinical research, particularly in oncology. Methodology: They consist of coupling a fluorescent marker in the form of an NHS derivative, such as IR DYE manufactured in compliance with GMP, with therapeutic monoclonal antibodies having marketing authorization for molecular imaging. For a given antibody, the marking procedure must be the subject of a validation file on the final preparation filtered on a sterilizing membrane at 0.22 μm. Once the procedure has been validated, it would be unnecessary to repeat the tests before each clinical research examination. A check of the marking by thin-layer chromatography (TLC) and place it in a sample bank at +4˚C for 1 month of each injected formulation would be sufficient for additional tests if necessary. Conclusion: Molecular near-infrared fluorescence imaging is experiencing development, the process of which could be accelerated by greater availability of clinical contrast agents. Alternative solutions are therefore necessary to promote clinical research in this area. These methods must be shared to make it easier for researchers. 展开更多
关键词 fluorescence Imaging Contrast Agents Clinical Research
下载PDF
Isomeric fluorescence sensors for wide range detection of ionizing radiations
5
作者 Jimin Han Tianyu Yang +1 位作者 Li Yang Yuanjian Li 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第4期247-257,共11页
In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduce... In order to achieve a wider range of ionizing radiations detection,novel fluorescence sensing materials have been developed that utilize the fluorescence enhancement phenomenon caused by the intramolecular photoinduced electron transfer(PET)effect.Two perylene diimide isomers PDI-P and PDI-B were designed and synthesized,and their molecular structures were characterized by high-resolution Fourier transform mass spectrometry(HRMS),nuclear magnetic resonance hydrogen and carbon spectroscopy(~1H and~(13)C NMR).The interaction between ionizing radiation and fluorescent molecules was simulated by HCl titration.The results show that combining PDIs and HCl can improve fluorescence through the retro-PET process.Despite the similarities in chemical structures,the fluorescent enhancement multiple of PDI-B with aromatic amine as electron donor is much higher than that of PDI-P with alkyl amine.In the direct irradiation experiments of ionizing radiation,the emission enhancement multiples of PDI-P and PDI-B are 2.01 and 45.4,respectively.Furthermore,density functional theory(DFT)and time-dependent density functional theory(TDDFT)calculations indicate that the HOMO and HOMO-1 energy ranges of PDI-P and PDI-B are 0.54 e V and 1.13 e V,respectively.A wider energy range has a stronger driving force on electrons,which is conducive to fluorescence quenching.Both femtosecond transient absorption spectroscopy(fs-TAS)and transient fluorescence spectroscopy(TFS)tests show that PDI-B has shorter charge separation lifetime and higher electron transfer rate constant.Although both isomers can significantly reduce LOD during PET process,PDI-B with aromatic amine has a wider detection range of 0.118—240 Gy due to its larger emission enhancement,which is a leap of three orders of magnitude.It breaks through the detection range of gamma radiation reported in existing studies,and provides theoretical support for the further study of sensitive and effective new materials for ionizing radiation detection. 展开更多
关键词 Perylene imide Intramolecular PET Ionizing radiation detection fluorescence sensor ISOMERS
下载PDF
Pay attention to the application of indocyanine green fluorescence imaging technology in laparoscopic liver cancer resection
6
作者 Li-Min Kang Fu-Wei Zhang +1 位作者 Fa-Kun Yu Lei Xu 《World Journal of Clinical Cases》 SCIE 2024年第23期5288-5293,共6页
Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.... Traditional laparoscopic liver cancer resection faces challenges,such as difficultiesin tumor localization and accurate marking of liver segments,as well as theinability to provide real-time intraoperative navigation.This approach falls shortof meeting the demands for precise and anatomical liver resection.The introductionof fluorescence imaging technology,particularly indocyanine green,hasdemonstrated significant advantages in visualizing bile ducts,tumor localization,segment staining,microscopic lesion display,margin examination,and lymphnode visualization.This technology addresses the inherent limitations oftraditional laparoscopy,which lacks direct tactile feedback,and is increasinglybecoming the standard in laparoscopic procedures.Guided by fluorescenceimaging technology,laparoscopic liver cancer resection is poised to become thepredominant technique for liver tumor removal,enhancing the accuracy,safetyand efficiency of the procedure. 展开更多
关键词 Indocyanine green fluorescence imaging technology LAPAROSCOPY HEPATECTOMY Liver tumor
下载PDF
A ratiometric fluorescent probe for hypoxanthine detection in aquatic products based on the enzyme mimics and fluorescence of cobalt-doped carbon nitride
7
作者 Xin Wang Chengyi Hong +1 位作者 Zhengzhong Lin Zhiyong Huang 《Food Science and Human Wellness》 SCIE CSCD 2024年第2期879-884,共6页
A ratiometric fluorescent probe for hypoxanthine(Hx)detection was established based on the mimic enzyme and fluorescence characteristics of cobalt-doped graphite-phase carbon nitride(Co doped g-C_(3)N_(4)).In addition... A ratiometric fluorescent probe for hypoxanthine(Hx)detection was established based on the mimic enzyme and fluorescence characteristics of cobalt-doped graphite-phase carbon nitride(Co doped g-C_(3)N_(4)).In addition to emitting strong fluorescence,the peroxidase activity of Co doped g-C_(3)N_(4)can catalyze the reaction of O-phenylenediamine and H_(2)O_(2)to produce diallyl phthalate which can emit yellow fluorescence at 570 nm.Through the decomposition of Hx by xanthine oxidase,Hx can be indirectly detected by the generating hydrogen peroxide based on the measurement of fluorescent ratio I(F_(570)/F_(370)).The linear range was 1.7-272.2 mg/kg(R^(2)=0.997),and the detection limit was 1.52 mg/kg(3σ/K,n=9).The established method was applied to Hx detection in bass,grass carp,and shrimp,and the data were verified by HPLC.The result shows that the established probe is sensitive,accurate,and reliable,and can be used for Hx detection in aquatic products. 展开更多
关键词 Co doped g-C_(3)N_(4) Ratiometric fluorescent probe HYPOXANTHINE FRESHNESS Aquatic products
下载PDF
Application value of indocyanine green fluorescence imaging in guiding sentinel lymph node biopsy diagnosis of gastric cancer: Meta-analysis
8
作者 Qi-Jia Zhang Zhi-Cheng Cao +4 位作者 Qin Zhu Yu Sun Rong-Da Li Jin-Long Tong Qin Zheng 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1883-1893,共11页
BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a n... BACKGROUND Gastric cancer is a common malignant tumor of the digestive system worldwide,and its early diagnosis is crucial to improve the survival rate of patients.Indocyanine green fluorescence imaging(ICG-FI),as a new imaging technology,has shown potential application prospects in oncology surgery.The meta-analysis to study the application value of ICG-FI in the diagnosis of gastric cancer sentinel lymph node biopsy is helpful to comprehensively evaluate the clinical effect of this technology and provide more reliable guidance for clinical practice.AIM To assess the diagnostic efficacy of optical imaging in conjunction with indocya-nine green(ICG)-guided sentinel lymph node(SLN)biopsy for gastric cancer.METHODS Electronic databases such as PubMed,Embase,Medline,Web of Science,and the Cochrane Library were searched for prospective diagnostic tests of optical imaging combined with ICG-guided SLN biopsy.Stata 12.0 software was used for analysis by combining the"bivariable mixed effect model"with the"midas"command.The true positive value,false positive value,false negative value,true negative value,and other information from the included literature were extracted.A literature quality assessment map was drawn to describe the overall quality of the included literature.A forest plot was used for heterogeneity analysis,and P<0.01 was considered to indicate statistical significance.A funnel plot was used to assess publication bias,and P<0.1 was considered to indicate statistical significance.The summary receiver operating characteristic(SROC)curve was used to calculate the area under the curve(AUC)to determine the diagnostic accuracy.If there was interstudy heterogeneity(I2>50%),meta-regression analysis and subgroup analysis were performed.analysis were performed.RESULTS Optical imaging involves two methods:Near-infrared(NIR)imaging and fluorescence imaging.A combination of optical imaging and ICG-guided SLN biopsy was useful for diagnosis.The positive likelihood ratio was 30.39(95%CI:0.92-1.00),the sensitivity was 0.95(95%CI:0.82-0.99),and the specificity was 1.00(95%CI:0.92-1.00).The negative likelihood ratio was 0.05(95%CI:0.01-0.20),the diagnostic odds ratio was 225.54(95%CI:88.81-572.77),and the SROC AUC was 1.00(95%CI:The crucial values were sensitivity=0.95(95%CI:0.82-0.99)and specificity=1.00(95%CI:0.92-1.00).The Deeks method revealed that the"diagnostic odds ratio"funnel plot of SLN biopsy for gastric cancer was significantly asymmetrical(P=0.01),suggesting significant publication bias.Further meta-subgroup analysis revealed that,compared with fluorescence imaging,NIR imaging had greater sensitivity(0.98 vs 0.73).Compared with optical imaging immediately after ICG injection,optical imaging after 20 minutes obtained greater sensitivity(0.98 vs 0.70).Compared with that of patients with an average SLN detection number<4,the sensitivity of patients with a SLN detection number≥4 was greater(0.96 vs 0.68).Compared with hematoxylin-eosin(HE)staining,immunohistochemical(+HE)staining showed greater sensitivity(0.99 vs 0.84).Compared with subserous injection of ICG,submucosal injection achieved greater sensitivity(0.98 vs 0.40).Compared with 5 g/L ICG,0.5 and 0.05 g/L ICG had greater sensitivity(0.98 vs 0.83),and cT1 stage had greater sensitivity(0.96 vs 0.72)than cT2 to cT3 clinical stage.Compared with that of patients≤26,the sensitivity of patients>26 was greater(0.96 vs 0.65).Compared with the literature published before 2010,the sensitivity of the literature published after 2010 was greater(0.97 vs 0.81),and the differences were statistically significant(all P<0.05).CONCLUSION For the diagnosis of stomach cancer,optical imaging in conjunction with ICG-guided SLN biopsy is a therapeut-ically viable approach,especially for early gastric cancer.The concentration of ICG used in the SLN biopsy of gastric cancer may be too high.Moreover,NIR imaging is better than fluorescence imaging and may obtain higher sensitivity. 展开更多
关键词 Gastric neoplasms Sentinel lymph nodes Near infrared imaging fluorescence imaging Indocyanine green META-ANALYSIS
下载PDF
Determination of Benzo[a]pyrene in Edible Oil by High Performance Liquid Chromatography-Fluorescence Detector (HPLC-FL)
9
作者 Guixia YANG Jie LIU +3 位作者 Xiujuan WANG Fenglan ZHANG Kun XIN Chunli KONG 《Agricultural Biotechnology》 2024年第2期8-9,19,共3页
In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Sc... In this study, an optimized high performance liquid chromatography-fluorescence detector (HPLC-FL) method for the determination of benzo[a]pyrene in edible oil was established. HPLC was performed with Thermo Fisher Scientific C18 column (250 mm×4.6 mm, 5 μm) as the chromatographic column and acetonitrile and water as the mobile phase, and the excitation wavelength and emission wavelength of fluorescence detector were 286 and 430 nm, respectively. The response was high, and the linear range was 0.5-10.0 ng/ml. The lowest limit of detection was 0.11 ng/ml, and the average recovery was 92.5%. This method is suitable for quantitative analysis of benzo[a]pyrene content in edible oil. 展开更多
关键词 BENZO[A]PYRENE High performance liquid chromatography fluorescence detector
下载PDF
Establishment of Double-antigen Sandwich Time-resolved Fluorescence Immunoassay for Detection of Pest des Petits Ruminants Virus
10
作者 Binglei CAO Zhongyuan GE +3 位作者 Qi YANG Hang SUN Yu SUN Xiaohui SONG 《Agricultural Biotechnology》 2024年第4期21-27,共7页
[Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PP... [Objectives]This study was conducted to explore rapid and large-scale screening and detection of peste des petits ruminants(PPR),so as to provide important technical means for prevention,control and purification of PPR.[Methods]Soluble N protein and NH fusion protein were successfully obtained in an Escherichia coli expression system by optimizing E.coli codon and expression conditions.Furthermore,based on purified soluble N protein and NH fusion protein,a double-antigen sandwich time-resolved fluorescence immunoassay method for detection of peste des petits ruminants virus(PPRV)was established.[Results]The method has high sensitivity and specificity and can specifically detect the antibody against PPRV in sheep serum,and it has no cross reaction with other related diseases.The method was used to detect 292 clinical samples,and compared with French IDVET competition ELISA kit.The coincidence rates of positive samples and negative samples from the two kinds of test kits were 92.47%and 97.26%,respectively,and the overall coincidence rate was 94.86%.The intra-group and inter-group coefficients of variation in the repeatability test were less than 10%.[Conclusions]Compared with the traditional ELISA method,the double-antigen sandwich time-resolved fluorescence immunoassay for detection of PPRV has equivalent sensitivity and specificity,and simple and rapid operation,and thus high application and popularization value. 展开更多
关键词 Peste des petits ruminants N active protein NH fusion protein Soluble expression and purification Time-resolved fluorescence immunoassay
下载PDF
Dynamic Non-Invasive Detection of NADH Based on Blood Flow-Mediated Skin Fluorescence (FMSF) Method
11
作者 Peng Liu Tengfei Bi +2 位作者 Gongzhi Du Long Yan Huayi Hou 《Open Journal of Applied Sciences》 2024年第6期1437-1453,共17页
Nicotinamide adenine dinucleotide (NADH/NAD+) is involved in important biochemical reactions in human metabolism, including participation in energy production by mitochondria. The changes in fluorescence intensity as ... Nicotinamide adenine dinucleotide (NADH/NAD+) is involved in important biochemical reactions in human metabolism, including participation in energy production by mitochondria. The changes in fluorescence intensity as a function of time in response to blocking and releasing of blood flow in a forearm are used as a measure of oxygen transport with blood to the tissue, which directly correlates with the skin microcirculation status. In this paper, a non-invasive dynamic monitoring system based on blood flow-mediated skin fluorescence (FMSF) technology is developed to monitor the NADH fluorescence intensity of skin tissue during the process of blocking reactive hyperemia. Simultaneously, laser speckle contrast imaging (LSCI) and laser Doppler flowmetry (LDF) were used to observe blood flow, blood oxygen saturation (SOt2) and relative amount of hemoglobin (rHb) during the measurement process, which helped to explore NADH dynamics relevant physiological changes. A variety of parameters have been derived to describe NADH fluorescence curve based on the FMSF device. The experimental results are conducive to understanding the NADH measurement and the physiological processes related to it, which help FMSF to be a great avenue for in vivo physiological, clinical and pharmacological research on mitochondrial metabolism. 展开更多
关键词 Reduced Nicotinamide Adenine Dinucleotide (NADH) Flow-Mediated Skin fluorescence (FMSF) Laser Doppler Flowmetry (LDF) Blood Flow
下载PDF
基于双色PLIF的推进剂燃烧场定量测温方法 被引量:1
12
作者 逯勇旭 邓琥 +2 位作者 武志翔 孔锤锐 尚丽平 《传感器与微系统》 CSCD 北大核心 2024年第4期140-143,共4页
在燃烧学研究领域中,平面激光诱导荧光(PLIF)可以有效鉴别组分类型,获取火焰中微量组分的二维平面成像以及通过分子振动能级的分布测量温度。本文基于双色PLIF技术搭建PLIF测温实验系统,以推进剂燃烧作为研究对象,采用—OH基中的Q_(2)(... 在燃烧学研究领域中,平面激光诱导荧光(PLIF)可以有效鉴别组分类型,获取火焰中微量组分的二维平面成像以及通过分子振动能级的分布测量温度。本文基于双色PLIF技术搭建PLIF测温实验系统,以推进剂燃烧作为研究对象,采用—OH基中的Q_(2)(11)与P_(1)(7)2条谱线开展双色PLIF技术测温实验,结合采集到的—OH基荧光图像,获取推进剂火焰二维温度场分布。通过火焰二维温度场分布情况与热电偶的测温结果进行对比及误差分析。对比结果表明:双色PLIF测温技术的测温误差为12.2 K,不确定度小于5%。该方法具有非接触、高灵敏度等特性,适用于稳态燃烧场温度测量。 展开更多
关键词 平面激光诱导荧光 —OH基 二维温度场 推进剂
下载PDF
Indocyanine green fluorescence in gastrointestinal surgery:Appraisal of current evidence 被引量:2
13
作者 Raja Kalayarasan Murugesan Chandrasekar +1 位作者 Pothugunta Sai Krishna Dasarathan Shanmugam 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第12期2693-2708,共16页
Applying indocyanine green(ICG)fluorescence in surgery has created a new dimension of navigation surgery to advance in various disciplines.The research in this field is nascent and fragmented,necessitating academic ef... Applying indocyanine green(ICG)fluorescence in surgery has created a new dimension of navigation surgery to advance in various disciplines.The research in this field is nascent and fragmented,necessitating academic efforts to gain a comprehensive understanding.The present review aims to integrate diverse perspectives and recent advances in its application in gastrointestinal surgery.The relevant articles were selected by using the appropriate keyword search in PubMed.The angiography and cholangiography property of ICG fluorescence is helpful in various hepatobiliary disorders.In gastroesophageal and colorectal surgery,the lymphangiography and angiography property of ICG is applied to evaluate bowel vascularity and guide lymphadenectomy.The lack of objective parameters to assess ICG fluorescence has been the primary limitation when ICG is used to evaluate bowel perfusion.The optimum dose and timing of ICG administration need to be standardized in some new application areas in gastrointestinal surgery.Binding tumor-specific ligands with fluorophores can potentially widen the fluorescence application to detect primary and metastatic gastrointestinal tumors.The narrative review outlines prior contributions,limitations,and research opportunities for future studies across gastrointestinal sub-specialty.The findings of the present review would be helpful for scholars and practitioners to explore and progress in this exciting domain of gastrointestinal surgery. 展开更多
关键词 Indocyanine green fluorescence Navigation surgery ANGIOGRAPHY CHOLANGIOGRAPHY LYMPHANGIOGRAPHY
下载PDF
Monitoring the in vivo siRNA release from lipid nanoparticles based on the fluorescence resonance energy transfer principle 被引量:1
14
作者 Lei Sun Jinfang Zhang +11 位作者 Jing-e Zhou JingWang Zhehao Wang Shenggen Luo Yeying Wang Shulei Zhu Fan Yang Jie Tang Wei Lu Yiting Wang Lei Yu Zhiqiang Yan 《Asian Journal of Pharmaceutical Sciences》 SCIE CAS 2023年第1期72-85,共14页
The siRNA-loaded lipid nanoparticles have attracted much attention due to its significant gene silencing effect and successful marketization.However,the in vivo distribution and release of siRNA still cannot be effect... The siRNA-loaded lipid nanoparticles have attracted much attention due to its significant gene silencing effect and successful marketization.However,the in vivo distribution and release of siRNA still cannot be effectively monitored.In this study,based on the fluorescence resonance energy transfer(FRET)principle,a fluorescence dye Cy5-modified survivin siRNA was conjugated to nanogolds(Au-DR-siRNA),which were then wrapped with lipid nanoparticles(LNPs)for monitoring the release behaviour of siRNA in vivo.The results showed that once Au-DR-siRNA was released from the LNPs and cleaved by the Dicer enzyme to produce free siRNA in cells,the fluorescence of Cy5 would change from quenched state to activated state,showing the location and time of siRNA release.Besides,the LNPs showed a significant antitumor effect by silencing the survivin gene and a CT imaging function superior to iohexol by nanogolds.Therefore,this work provided not only an effective method for monitoring the pharmacokinetic behaviour of LNP-based siRNA,but also a siRNA delivery system for treating and diagnosing tumors. 展开更多
关键词 Survivin siRNA Lipid nanoparticles In vivo release Nanogolds fluorescence resonance energy transfer
下载PDF
用于大尺度模型发动机高频PLIF测量的脉冲串紫外激光系统
15
作者 曹振 于欣 +7 位作者 彭江波 柳强 杨顺华 张顺平 赵延辉 李沛霖 高龙 张善春 《光谱学与光谱分析》 SCIE EI CAS CSCD 北大核心 2024年第4期932-936,共5页
针对大尺度模型发动机试验台工作时间短(~百毫秒到秒量级)和激光能量要求高(>1 mJ)的特点,常规的紫外激光系统不能满足发动机燃烧流场精细化测量需求,要求用于高频平面激光诱导荧光(PLIF)测量的紫外激光系统同时满足脉冲串时间间隔... 针对大尺度模型发动机试验台工作时间短(~百毫秒到秒量级)和激光能量要求高(>1 mJ)的特点,常规的紫外激光系统不能满足发动机燃烧流场精细化测量需求,要求用于高频平面激光诱导荧光(PLIF)测量的紫外激光系统同时满足脉冲串时间间隔短和激光输出能量高,并且系统具有高可靠性和环境适应性。设计了一套用于真实发动机地面试验台高频PLIF测量的脉冲串紫外激光系统,能够获取有效的火焰动力学数据。脉冲串紫外激光系统采用自主研制的脉冲串模式激光器泵浦染料激光器,具备能量监测、波长监测和片光分布监测等功能,可以校正激光参数对测量结果的影响。其中脉冲串模式激光器采用电光调Q、脉冲串模式和MOPA技术,使输出的泵浦激光具有高脉冲能量(~50 mJ@532 nm)、短脉冲宽度(~10.8 ns)和较高的脉冲串频率(20 Hz)。脉冲串紫外激光系统的串时间间隔为50 ms,是国外激光器脉冲串间隔时间的1/200;系统整体转换效率为6%,紫外单脉冲能量为2.95 mJ@283 nm,是国外连续脉冲激光器典型能量值的7倍。为满足发动机地面试验台测量需求,自主集成了工程可用的高可靠性移动式10 kHz PLIF测量系统,具有抗震、防潮和防尘等功能,提升了高频PLIF系统的环境适应能力。国内首次在中国空气动力研究与发展中心的脉冲燃烧风洞上实现了大尺度模型发动机燃烧流场远距离大视场成像测量(~15 cm),获得了高信噪比的氢燃料及乙烯燃料高动态燃烧过程可视化结果。未来可结合光谱图像特征提取与分析方法对其燃烧状态和动态过程开展研究,为发动机复杂流动燃烧机理研究、CFD仿真和发动机设计水平提升提供支撑。 展开更多
关键词 燃烧诊断 脉冲串激光器 平面激光诱导荧光 大尺度模型发动机
下载PDF
From static to dynamic:live observation of the support system after ischemic stroke by two photon-excited fluorescence laser-scanning microscopy 被引量:1
16
作者 Xuan Wu Jia-Rui Li +3 位作者 Yu Fu Dan-Yang Chen Hao Nie Zhou-Ping Tang 《Neural Regeneration Research》 SCIE CAS CSCD 2023年第10期2093-2107,共15页
Ischemic stroke is one of the most common causes of mortality and disability worldwide.However,treatment efficacy and the progress of research remain unsatisfactory.As the critical support system and essential compone... Ischemic stroke is one of the most common causes of mortality and disability worldwide.However,treatment efficacy and the progress of research remain unsatisfactory.As the critical support system and essential components in neurovascular units,glial cells and blood vessels(including the bloodbrain barrier)together maintain an optimal microenvironment for neuronal function.They provide nutrients,regulate neuronal excitability,and prevent harmful substances from entering brain tissue.The highly dynamic networks of this support system play an essential role in ischemic stroke through processes including brain homeostasis,supporting neuronal function,and reacting to injuries.However,most studies have focused on postmortem animals,which inevitably lack critical information about the dynamic changes that occur after ischemic stroke.Therefore,a high-precision technique for research in living animals is urgently needed.Two-photon fluorescence laser-scanning microscopy is a powerful imaging technique that can facilitate live imaging at high spatiotemporal resolutions.Twophoton fluorescence laser-scanning microscopy can provide images of the whole-cortex vascular 3D structure,information on multicellular component interactions,and provide images of structure and function in the cranial window.This technique shifts the existing research paradigm from static to dynamic,from flat to stereoscopic,and from single-cell function to multicellular intercommunication,thus providing direct and reliable evidence to identify the pathophysiological mechanisms following ischemic stroke in an intact brain.In this review,we discuss exciting findings from research on the support system after ischemic stroke using two-photon fluorescence laser-scanning microscopy,highlighting the importance of dynamic observations of cellular behavior and interactions in the networks of the brain’s support systems.We show the excellent application prospects and advantages of two-photon fluorescence laser-scanning microscopy and predict future research developments and directions in the study of ischemic stroke. 展开更多
关键词 ASTROCYTES blood-brain barrier calcium signaling glymphatic system ischemic stroke MICROGLIA network remodel two-photon fluorescence laser-scanning microscopy VESSELS
下载PDF
Dual fluorescence in situ hybridization in detection of HER-2 oncogene amplification in primary hepatocellular carcinoma 被引量:5
17
作者 Tie-Jun Huang, Bi-Jun Huang, Qi-Wan Liang, Chu-Wen Huang and Yan Fang Guangzhou, China Department of Nuclear Medicine , Second Municipal Hospital of Shenzhen, Shenzhen 518035, China Research Department, Cancer Center, Sun Yat-Sen University, Guangzhou 510060 , China 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2004年第1期62-68,共7页
BACKGROUND: Molecular cytogenetics of oncogene HER-2 amplification in primary hepatocellular carcinoma (HCC) is still unknown. The aim of this study was to in vestigate the frequency of HER-2 oncogene amplification in... BACKGROUND: Molecular cytogenetics of oncogene HER-2 amplification in primary hepatocellular carcinoma (HCC) is still unknown. The aim of this study was to in vestigate the frequency of HER-2 oncogene amplification in primary HCC and its relations to clinicopathological pa rameters and prognosis. METHODS: Forty-two surgical samples from patients with primary HCC were detected for their HER-2 oncogene am plification. The number of chromosome 17 and their ratio were tested by dual fluorescence in situ hybridization (FISH) technique, and then the correlations between HER-2 amplification, clinicopathological characteristics and prog nosis were analyzed statistically. RESULTS: HER-2 oncogene amplification was detected in 9 (21.4%) of the 42 primary HCCs, including 4 patient with high copy (HC) (9.5%) and 5 patients with low copy (LC) (11.9%). HER-2 amplification was associated signifi cantly with tumor size and postoperative survival time o HCC patients (P<0.05), and the presence of HER-2 gene amplification was correlated with postoperative relapse (P— 0.257), but not related to sex, age, AFP level, HBV infec tion, histopathological grading and clinical staging of HCC patients (P>0.05). The HER-2 oncogene copy was exa mined in 31 (73.8%) of the 42 primary HCCs, consisting of 9 patients with HER-2 amplification (21.4%) and 22 pa tients with aneuploidy (52.4%). No significant relation were observed between the HER-2 oncogene copy, patien sex, tumor size, histopathological grading, clinical stag ing, postoperative relapse and survival time (P >0.05); bu the HER-2 oncogene copy was correlated significantly to age, AFP level and HBV infection (P <0.05). CONCLUSIONS: There are a lower frequency of HER-2 oncogene amplification and a higher frequency of chromo- some 17 aneuploidy in primary HCC. HER-2 oncogene amplification may be involved in the development and pro- gression of large HCC in some patients, and seems to be a valuably independent prognostic factor predicting the re- currence and poor survival in patients with large HCC. 展开更多
关键词 hepatocellular carcinoma primary HER-2 oncogene AMplifICATION dual fluorescence in situ hybridization
下载PDF
Molecular fluorescence significantly enhanced by gold nanoparticles@zeolitic imidazolate framework-8
18
作者 张钰伊 卞亚杰 +5 位作者 张炜 刘易婷 张晓磊 陈梦迪 胡炳文 金庆原 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期462-470,共9页
Noble metal nanoparticles exhibit unique surface plasmon resonance dependent optical properties.On this basis,gold nanoparticles(AuNPs)encapsulated in metal–organic frameworks(MOFs)can form AuNPs@MOFs composites to m... Noble metal nanoparticles exhibit unique surface plasmon resonance dependent optical properties.On this basis,gold nanoparticles(AuNPs)encapsulated in metal–organic frameworks(MOFs)can form AuNPs@MOFs composites to modulate the optical properties of fluorescent molecules,which is less reported.In this paper,based on the fluorescence enhancement effect of AuNPs on 2-(2-hydroxyphenyl)-1H-benzimidazole(HPBI)molecules,zeolitic imidazolate framework-8(ZIF-8)crystals with structural stability were introduced.AuNPs@ZIF-8 exhibited a significantly pronounced fluorescence enhancement of the HPBI molecules.In addition,by comparing the fluorescence characteristics of the HPBI molecules adsorbed on AuNPs@ZIF-8 and those captured in AuNPs@ZIF-8,we found that the ZIF-8 can act as a spacer layer with highly effective near-field enhancement.All our preliminary results shed light on future research on the composite structures of noble metal particles and MOFs for fluorescent probes and sensing applications. 展开更多
关键词 ZIF-8 gold nanoparticles fluorescence spectra fluorescence lifetime
下载PDF
Experimental Study on Ultrasonic Cavitation Intensity Based on Fluorescence Analysis
19
作者 Linzheng Ye Shida Chuai +1 位作者 Xijing Zhu Dong Wang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第4期196-204,共9页
The Ultrasonic cavitation effect has been widely used in mechanical engineering,chemical engineering,biomedicine,and many other fields.The quantitative characterization of ultrasonic cavitation intensity has always be... The Ultrasonic cavitation effect has been widely used in mechanical engineering,chemical engineering,biomedicine,and many other fields.The quantitative characterization of ultrasonic cavitation intensity has always been a difficulty.Based on this,a fluorescence analysis method has been adopted to explore ultrasonic cavitation intensity in this paper.In the experiment of fluorescence intensity measurement,terephthalic acid(TA)was used as the fluorescent probe,ultrasonic power,ultrasonic frequency,and irradiation time were independent variables,and fluorescence intensity and fluorescence peak area were used as experimental results.The collapse of cavitation bubble will cause molecular bond breakage and release·OH,and the non-fluorescent substance TA will form the strong fluorescent substance TAOH with·OH.The spectra of the treated samples were measured by a F-7000 fluorescence spectrophotometer.The results showed that the fluorescence intensity and fluorescence peak area increased rapidly after ultrasonic cavitation treatment,and then increased slowly with the increase of ultrasonic power,which gradually increased with the increase of irradiation time.They first decreased and then increased with the increase of ultrasonic frequency from 20 kHz to 40 kHz.The irradiation time was the most influential factor,and the cavitation intensity of low frequency was higher overall.The fluorescence intensity and fluorescence peak area of the samples increased by 2-20 times after ultrasonic treatment,which could increase from 69 and 5238 to 1387 and 95451,respectively.After the irradiation time exceeded 25 min,the growth rate of fluorescence intensity slowed down,which was caused by the decrease of gas content and TA concentration in the solution.The study quantitatively characterized the cavitation intensity,reflecting the advantages of fluorescence analysis,and provided a basis for the further study of ultra-sonic cavitation. 展开更多
关键词 Ultrasonic cavitation Cavitation intensity fluorescence intensity fluorescence peak area
下载PDF
Spectrum Correction in Study of Solvation Dynamics by Fluorescence Non-collinear Optical Parametric Amplification Spectroscopy
20
作者 党伟 白晶晶 +1 位作者 张连水 翁羽翔 《Chinese Journal of Chemical Physics》 SCIE CAS CSCD 2016年第1期147-150,I0003,共5页
Femtosecond time-resolved fluorescence non-collinear optical parametric amplification spec- troscopy can extract the curve of spectral gain from its parametric superfluorescence. This unique spectrum correction method... Femtosecond time-resolved fluorescence non-collinear optical parametric amplification spec- troscopy can extract the curve of spectral gain from its parametric superfluorescence. This unique spectrum correction method enables fluorescence non-collinear optical parametric amplification spectroscopy acquiring the genuine transient fluorescence spectrum of the studied system. In this work we employ fluorescence non-collinear optical parametric amplification spectroscopy technique to study the solvation dynamics of DCM dye in ethanol solution, and confirm that genuine solvation correlation function and shift of peak frequency can be derived from transient fluorescence spectra after the spectral gain correction. It demonstrates that fluorescence non-collinear optical parametric amplification spectroscopy can benefit the research fields, which focuses on both fluorescence intensity dynamics and fluorescence spectral shape evolution. 展开更多
关键词 Transient fluorescence spectrum Solvation dynamics Non-collinear optical parametric amplification Spectrum correction
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部