期刊文献+
共找到715篇文章
< 1 2 36 >
每页显示 20 50 100
On-site rapid detection of multiple pesticide residues in tea leaves by lateral flow immunoassay
1
作者 Junxia Gao Tianyi Zhang +7 位作者 Yihua Fang Ying Zhao Mei Yang Li Zhao Ye Li Jun Huang Guonian Zhu Yirong Guo 《Journal of Pharmaceutical Analysis》 SCIE CAS CSCD 2024年第2期276-283,共8页
The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pe... The application of pesticides (mostly insecticides and fungicides) during the tea-planting process will undoubtedly increase the dietary risk associated with drinking tea. Thus, it is necessary to ascertain whether pesticide residues in tea products exceed the maximum residue limits. However, the complex matrices present in tea samples comprise a major challenge in the analytical detection of pesticide residues. In this study, nine types of lateral flow immunochromatographic strips (LFICSs) were developed to detect the pesticides of interest (fenpropathrin, chlorpyrifos, imidacloprid, thiamethoxam, acetamiprid, carbendazim, chlorothalonil, pyraclostrobin, and iprodione). To reduce the interference of tea substrates on the assay sensitivity, the pretreatment conditions for tea samples, including the extraction solvent, extraction time, and purification agent, were optimized for the simultaneous detection of these pesticides. The entire testing procedure (including pretreatment and detection) could be completed within 30 min. The detected results of authentic tea samples were confirmed by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS), which suggest that the LFICS coupled with sample rapid pretreatment can be used for on-site rapid screening of the target pesticide in tea products prior to their market release. 展开更多
关键词 lateral flow immunoassay Rapid detection Pesticide multi-residue Tea matrix Sample rapid pretreatment
下载PDF
采用Allergy Lateral Flow Assay检测过敏原特异性IgE抗体的性能评价 被引量:3
2
作者 陈辉雄 胡海圣 +2 位作者 罗文婷 吴泽鸿 孙宝清 《国际检验医学杂志》 CAS 2020年第2期141-145,共5页
目的Allergy Lateral Flow Assay(ALFA)是一种便捷、小巧的过敏原检测新技术,本研究以荧光酶联免疫全定量ImmunoCAP法为“金标准”,旨在探讨ALFA的检验效能及在中国南方地区的应用价值。方法利用ALFA技术与ImmunoCAP技术检测100例过敏... 目的Allergy Lateral Flow Assay(ALFA)是一种便捷、小巧的过敏原检测新技术,本研究以荧光酶联免疫全定量ImmunoCAP法为“金标准”,旨在探讨ALFA的检验效能及在中国南方地区的应用价值。方法利用ALFA技术与ImmunoCAP技术检测100例过敏性疾病患者血清屋尘螨、粉尘螨、热带无爪螨、猫毛皮屑、狗毛皮屑、蟑螂和艾蒿sIgE水平。结果以ImmunoCAP法为“金标准”,结果显示,ALFA检测粉尘螨的一致性最高(κ=0.56,P<0.05),其次是屋尘螨(κ=0.43,P<0.05);同时,ALFA检测粉尘螨(87.6%)、猫毛皮屑(73.7%)和屋尘螨(87.6%)的总一致率均较高。经受试者工作特征曲线分析显示,ALFA诊断螨类过敏原的曲线下面积均大于0.90(P<0.05)。对于屋尘螨、粉尘螨和猫毛皮屑过敏原,ALFA与ImmunoCAP系统的sIgE检测结果具有强相关性(r I>0.8,P<0.05)。结论ALFA具有良好的诊断效能,可满足临床检测要求,因其无须昂贵的检测仪器和检测费用,可为基层医院临床筛查应用提供新的选择。 展开更多
关键词 ALLERGY lateral flow ASSAY IMMUNOCAP 过敏原
下载PDF
Hierarchical Nanogold Labels to Improve the Sensitivity of Lateral Flow Immunoassay 被引量:6
3
作者 Kseniya Serebrennikova Jeanne Samsonova Alexander Osipov 《Nano-Micro Letters》 SCIE EI CAS 2018年第2期67-74,共8页
Lateral flow immunoassay(LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation.However, an LFIA based on gold nanospheres lacks the desi... Lateral flow immunoassay(LFIA) is a widely used express method and offers advantages such as a short analysis time, simplicity of testing and result evaluation.However, an LFIA based on gold nanospheres lacks the desired sensitivity, thereby limiting its wide applications.In this study, spherical nanogold labels along with new types of nanogold labels such as gold nanopopcorns and nanostars were prepared, characterized, and applied for LFIA of model protein antigen procalcitonin. It was found that the label with a structure close to spherical provided more uniform distribution of specific antibodies on its surface, indicative of its suitability for this type of analysis.LFIA using gold nanopopcorns as a label allowed procalcitonin detection over a linear range of 0.5–10 ng mL^(-1) with the limit of detection of 0.1 ng mL^(-1), which was fivefold higher than the sensitivity of the assay with gold nanospheres. Another approach to improve the sensitivity of the assay included the silver enhancement method,which was used to compare the amplification of LFIA for procalcitonin detection. The sensitivity of procalcitonin determination by this method was 10 times better the sensitivity of the conventional LFIA with gold nanosphere as a label. The proposed approach of LFIA based on gold nanopopcorns improved the detection sensitivity without additional steps and prevented the increased consumption of specific reagents(antibodies). 展开更多
关键词 lateral flow immunoassay Gold nanosphere Gold nanopopcorn Gold nanostar Silver enhancement PROCALCITONIN
下载PDF
Study of Turbulent Flow of Film Cooling Holes with Lateral Expanded Exits 被引量:3
4
作者 施红辉 佐佐俊祐 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2002年第4期200-207,共8页
Hot wire measurements and flow visualization are presented for studying the turbulent flow field over a flat gas turbine film cooling blade with lateral expanded holes. Three mass flux ratios of jet to free stream, M ... Hot wire measurements and flow visualization are presented for studying the turbulent flow field over a flat gas turbine film cooling blade with lateral expanded holes. Three mass flux ratios of jet to free stream, M = 0.5, 0.89, 1.5, are tested. The streamwise velocity, the turbulent intensities and the Reynolds shear stress are measured. The effect of the lateral expanded holes on the improvement of the turbulent flow field for film cooling of gas turbines can be analyzed from the measured spatial di... 展开更多
关键词 turbulent flow film cooling lateral expanded hole hot wire anemometry flow visualization
下载PDF
Lateral Shear Layer and Its Velocity Distribution of Flow in Rectangular Open Channels 被引量:2
5
作者 Xiaonan Tang 《Journal of Applied Mathematics and Physics》 2019年第4期829-840,共12页
The lateral velocity distribution of flow in the shear layer of open channel is required to many problems in river and eco-environment engineering, e.g. distribution of pollutant dispersion, sediment transport and ban... The lateral velocity distribution of flow in the shear layer of open channel is required to many problems in river and eco-environment engineering, e.g. distribution of pollutant dispersion, sediment transport and bank erosion, and aquatic habitat. It is not well understood about how the velocity varies laterally in the wall boundary layer. This paper gives an analytical solution of lateral velocity distribution in a rectangular open channel based on the depth-averaged momentum equation proposed by Shiono & Knight. The obtained lateral velocity distributions in the wall shear layer are related to the two hydraulic parameters of lateral eddy viscosity (λ) and depth-averaged secondary flow (Γ) for given roughened channels. Preliminary relationships between the above two parameters and the aspect ratio of channel, B/H, are obtained from two sets of experimental data. The lateral width (δ) of the shear layer was investigated and found to relate to the λ and the bed friction factor (f), as described by Equation (26). This study indicates that the lateral shear layer near the wall can be very wide (δ/H = 14.6) for the extreme case (λ = 0.6 and f = 0.01). 展开更多
关键词 lateral SHEAR Layer Velocity Distribution Analytical Model lateral WIDTH Open Channel flow SECONDARY flow
下载PDF
Experimental and numerical study of the effect of pulsatile flow on wall displacement oscillation in a flexible lateral aneurysm model 被引量:2
6
作者 L.Z.Mu X.Y.Li +5 位作者 Q.Z.Chi S.Q.Yang P.D.Zhang C.J.Ji Y.He G.Gao 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2019年第5期1120-1129,共10页
This study experimentally and numerically investigated the effect of pulsatile flow of different frequencies and outflow resistance on wall deformation in a lateral aneurysm.A method for constructing a flexible aneury... This study experimentally and numerically investigated the effect of pulsatile flow of different frequencies and outflow resistance on wall deformation in a lateral aneurysm.A method for constructing a flexible aneurysm model was developed,and a self-designed piston pump was used to provide the pulsatile flow conditions.A fluid-structure interaction simulation was applied for comparison with and analysis of experimental findings.The maximum wall displacement oscillation increased as the pulsation frequency and outflow resistance increased,especially at the aneurysm dome.There is an obvious circular motion of the vortex center accompanying the periodic inflow fluctuation,and the pressure at the aneurysm dome at peak flow increased as the pulsatile flow frequency and terminal flow resistance increased.These results could explain why abnormal blood flow with high frequency and high outflow resistance is one of the risk factors for aneurysm rupture. 展开更多
关键词 lateral ANEURYSM In VITRO experiment PULSATILE flow Wall DISPLACEMENT OSCILLATION Fluid-structure interaction simulation
下载PDF
Lateral Flow Immunoassay for Quantitative Detection of Ractopamine in Swine Urine 被引量:3
7
作者 REN Mei Ling CHEN Xue Lan +4 位作者 LI Chao Hui XU Bo LIU Wen Juan XU Heng Yi XIONG Yong Hua 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2014年第2期134-137,共4页
A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT)... A strip reader based lateral flow immunoassay (LFIA) was established for the rapid and quantitative detection of ractopamine (RAC) in swine urine. The ratio of the optical densities (ODs) of the test line (AT) to that of the control line (Ac) was used to effectively minimize interference among strips and sample variations. The linear range for the quantitative detection of RAC was 0.2 ng/mL to 3.5 ng/mL with a median inhibitory concentration (IC50) of 0.59+0.06 ng/mL. The limit of detection (LOD) of the LFIA was 0.13 ng/mL. The intra-assay recovery rates were 92.97%, 97.25%, and 107.41%, whereas the inter-assay rates were 80.07%, 108.17%, and 93.7%, respectively. 展开更多
关键词 RAC lateral flow Immunoassay for Quantitative Detection of Ractopamine in Swine Urine FIGURE AT
下载PDF
Development of a Recombinase-aided Amplification Combined With Lateral Flow Dipstick Assay for the Rapid Detection of the African Swine Fever Virus 被引量:2
8
作者 LI Jiang Shuai HAO Yan Zhe +6 位作者 HOU Mei Ling ZHANG Xuan ZHANG Xiao Guang CAO Yu Xi LI Jin Ming MA Jing ZHOU Zhi Xiang 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2022年第2期133-140,共8页
Objective To establish a sensitive,simple and rapid detection method for African swine fever virus(ASFV)B646L gene.Methods A recombinase-aided amplification-lateral flow dipstick(RAA-LFD)assay was developed in this st... Objective To establish a sensitive,simple and rapid detection method for African swine fever virus(ASFV)B646L gene.Methods A recombinase-aided amplification-lateral flow dipstick(RAA-LFD)assay was developed in this study.Recombinase-aided amplification(RAA)is used to amplify template DNA,and lateral flow dipstick(LFD)is used to interpret the results after the amplification is completed.The lower limits of detection and specificity of the RAA assay were verified using recombinant plasmid and pathogenic nucleic acid.In addition,30 clinical samples were tested to evaluate the performance of the RAA assay.Results The RAA-LFD assay was completed within 15 min at 37°C,including 10 min for nucleic acid amplification and 5 minutes for LFD reading results.The detection limit of this assay was found to be 200 copies per reaction.And there was no cross-reactivity with other swine viruses.Conclusion A highly sensitive,specific,and simple RAA-LFD method was developed for the rapid detection of the ASFV. 展开更多
关键词 African swine fever virus Recombinase aided amplification lateral flow detection
下载PDF
Rapid and easy determination of morphine in chafing dish condiments with colloidal gold labeling based lateral flow strips 被引量:4
9
作者 Wei Chen Xin-ni Li +2 位作者 Qian Wu Li Yao Jianguo Xu 《Food Science and Human Wellness》 SCIE 2019年第1期40-45,共6页
In order to enhance the flavor of chafing dish and increase the attraction of consumers,the poppy shell is reported to be illegally added to the condiments of chafing dish.In this research,a rapid,simple,and convenien... In order to enhance the flavor of chafing dish and increase the attraction of consumers,the poppy shell is reported to be illegally added to the condiments of chafing dish.In this research,a rapid,simple,and convenient method based on the classic immunochromatographic lateral flow strip(LFS)with gold nanoparticles(GNPs)labeling was developed for easy monitoring of morphine(MOP),an effective component of poppy shell.Under optimized conditions,this developed LFS can well realize the detection of target MOP in the condiments of chafing dish in less than 10 min without any complicated pre-treatments.The limit of detection(LOD)can be achieved as low as 0.1 ppb for standard MOP or the MOP spiked condiments of chafing dish.All these results of the research strongly demonstrate that this established LFS method can be successfully applied in practical rapid and accurate on-site screening of poppy shell in condiments of chafing dish. 展开更多
关键词 Morphine(MOP) Gold nanoparticles(GNPs) lateral flow strip(LFS) Chafing dish condiments
下载PDF
Quantum Dot Nanobeads-Labelled Lateral Flow Immunoassay Strip for Rapid and Sensitive Detection of Salmonella Typhimurium Based on Strand Displacement Loop-Mediated Isothermal Amplification 被引量:1
10
作者 Yuting Shang Shuzhen Cai +10 位作者 Qinghua Ye Qingping Wu Yanna Shao Xiaoying Qu Xinran Xiang Baoqing Zhou Yu Ding Moutong Chen Liang Xue Honghui Zhu Jumei Zhang 《Engineering》 SCIE EI CAS 2022年第12期62-70,共9页
Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined ... Rapid,sensitive,point-of-care detection of pathogenic bacteria is important for food safety.In this study,we developed a novel quantum dot nanobeads-labelled lateral flow immunoassay strip(QBs-labelled LFIAS)combined with strand displacement loop-mediated isothermal amplification(SD-LAMP)for quantitative Salmonella Typhimurium(ST)detection.Quantum dot nanobeads(QBs)served as fluorescence reporters,providing good detection efficiency.The customizable strand displacement(SD)probe was used in LAMP to improve the specificity of the method and prevent by-product capture.Detection was based on a sandwich immunoassay.A fluorescence strip reader measured the fluorescence intensity(FI)of the test(T)line and control(C)line.The linear detection range of the strip was 10^(2)–10^(8) colony forming units(CFU)·mL^(-1).The visual limit of detection was 10^(3) CFU·mL^(-1),indicating that the system was ten-fold more sensitive than AuNPs-labelled test strips.ST specificity was analyzed in accordance with agarose gel outputs of polymerase chain reaction(PCR)and SD-LAMP.We detected ST in foods with an acceptable recovery of 85%–110%.The method is rapid,simple,almost equipment-free,and suitable for bacterial detection in foods and for clinical diagnosis. 展开更多
关键词 Salmonella Typhimurium Quantum dot nanobeads lateral flow immunoassay strip Loop-mediated isothermal amplification Strand displacement probe
下载PDF
Performance of simultaneous nitrification and denitrification in lateral flow biological aerated filter 被引量:1
11
作者 龙腾锐 《Journal of Chongqing University》 CAS 2006年第4期223-228,共6页
A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has ... A new wastewater treatment facility—lateral flow biological aerated filter (LBAF) was developed aiming at solving energy consumption and operational problems in wastewater treatment facilities in small towns. It has the function of nitrification and removing organic substrate. In this study, we focused on the denitrification performance of LBAF and its possible mechanism under thorough aeration. We identified the existence of simultaneous nitrification and denitrification (SND) by analyzing nitrogenous compounds along the flow path of LBAF and supportive microbial microscopy, and studied the effects of air/water ratio and hydraulic loading on the performance of nitrogen removal and on SND in LBAF to find out the optimal operation condition. It is found that for saving operation cost, aeration can be reduced to some degree that allows desirable removal efficiency of pollutants, and the optimal air/water ratio is 10:1. Hydraulic loading less than 0.43 m h?1 hardly affects the nitrification and denitrification performance; whereas higher hydraulic loading is unfavorable to both nitrification and denitrification, far more unfavorable to denitrification than to nitrification. 展开更多
关键词 lateral flow biological aerated filter simultaneous nitrification and denitrification air/water ratio hydraulic loading
下载PDF
Development of Lateral-flow Immunoassay for WSSV with Polyclonal Antibodies Raised against Recombinant VP (19+28) Fusion Protein 被引量:7
12
作者 Qing-yu CHENG Xiao-lin MENG Jin-ping XU Wei LU Jian WANG 《中国病毒学》 CSCD 2007年第1期61-67,共7页
我们为 WSSV 开发了敏感、快速的侧面流动的免疫分析(LFIA ) ,用象指示物的胶体的黄金。熔化蛋白质, VP (19+28 ) ,在 E 被表示。coli,净化并且过去常准备 polyclonal 抗体。净化的 anti-VP (19+28 ) IgG 与胶体的黄金被结合。Uncon... 我们为 WSSV 开发了敏感、快速的侧面流动的免疫分析(LFIA ) ,用象指示物的胶体的黄金。熔化蛋白质, VP (19+28 ) ,在 E 被表示。coli,净化并且过去常准备 polyclonal 抗体。净化的 anti-VP (19+28 ) IgG 与胶体的黄金被结合。Unconjugated anti-VP (19+28 ) IgG 和山羊反兔子 IgG 在硝化纤维素膜上被使不能调动。在汇编以后,虾样品的三个组(在每个组的 5 个单个动物) 被测试它包括了健康、垂死、死了的虾。为每个组,三不同纸巾(身体蜜汁,鳃和 hepatopancreas ) 同时被测试。在平行,所有样品也为比较用 PCR 被分析。从测试的 45 件样品,当 15 作为否定被分类时, 30 作为积极被检测。LFIA 的结果相关,那些由 PCR 分析获得了,显示这二个察觉方法有在在这初步的研究测试的样品的有限数字的一样的功效。关键词侧面流动的免疫分析 - 白点症候群病毒(WSSV )- VP19 - VP28 CLC 数字 S945. 展开更多
关键词 lateral-flow immunoassay White spot syndrome virus (WSSV) VP19 VP28
下载PDF
Rapid one-step enzyme immunoassay and lateral flow immunochromatographic assay for colistin in animal feed and food
13
作者 Jiayi Wang Jinyu Zhou +6 位作者 Yiqiang Chen Xinpei Zhang Yongpeng Jin Xiaojing Cui Dongting He Wenqing Lai Lidong He 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2020年第1期280-289,共10页
Background:Colistin(polymyxin E)is a kind of peptide antibiotic which has been approved in animal production for the purposes of disease prevention,treatment,and growth promotion.However,the wide use of colistin in an... Background:Colistin(polymyxin E)is a kind of peptide antibiotic which has been approved in animal production for the purposes of disease prevention,treatment,and growth promotion.However,the wide use of colistin in animal feed may accelerate the spread of colistin-resistance gene MCR-1 from animal production to human beings,and its residue in animal-origin food may also pose serious health hazards to humans.Thus,it is necessary to develop corresponding analytical methods to monitor the addition of colistin in animal feed and the colistin residue in animal-origin food.Results:A one-step enzyme-linked immunosorbent assay(ELISA)and a lateral flow immunochromatographic assay(LFIA)for colistin were developed based on a newly developed monoclonal antibody.The ELISA showed a 50%inhibition value(IC50)of 9.7 ng/m L with assay time less than 60 min,while the LFIA had a strip reader-based detection limit of 0.87 ng/m L in phosphate buffer with assay time less than 15 min.For reducing the non-specific adsorption of colistin onto sample vial,the components of sample extraction solution were optimized and proved to greatly improve the assay accuracy.The spiked recovery experiment showed that the recoveries of colistin from feed,milk and meat samples were in the range of 77.83%to 113.38%with coefficient of variations less than 13%by ELISA analysis and less than 18%by LFIA analysis,respectively.Furthermore,actual sample analysis indicated that the two immunoassays can produce results consistent with instrumental analysis.Conclusions:The developed assays can be used for rapid qualitative or quantitative detection of colistin in animal feed and food. 展开更多
关键词 COLISTIN ELISA Feed FOOD Gold nanoparticle lateral flow immunochromatographic ASSAY MONOCLONAL ANTIBODY
下载PDF
Numerical Study on Characteristics of Supercavitating Flow Around the Variable-Lateral-Force Cavitator
14
作者 HU Xiao GAO Ye SHI Xiao-tao 《China Ocean Engineering》 SCIE EI CSCD 2017年第1期123-129,共7页
A control scheme named the variable-lateral-force cavitator, which is focused on the control of lift force, drag force and lateral forces for underwater supercavity vehicles was proposed, and the supercavitating flow ... A control scheme named the variable-lateral-force cavitator, which is focused on the control of lift force, drag force and lateral forces for underwater supercavity vehicles was proposed, and the supercavitating flow around the cavitator was investigated numerically using the mixture multiphase flow model. It is verified that the forces of pitching, yawing, drag and lift, as well as the supercavity size of the underwater vehicle can be effectively regulated through the movements of the control element of the variable-lateral-force cavitator in the radial and circumferential directions. In addition, if the control element on either side protrudes to a height of 5% of the diameter of the front cavitator, an amount of forces of pitching and yawing equivalent to 30% of the drag force will be produced, and the supercavity section appears concave inwards simultaneously. It is also found that both the drag force and lift force of the variable-lateral-force cavitator decline as the angle of attack increases. 展开更多
关键词 supercavitating flow cavitator drag force lateral forces numerical investigation
下载PDF
Development of an accurate lateral flow immunoassay for PEDV detection in swine fecal samples with a filter pad design 被引量:1
15
作者 Siyi Zou Lei Wu +5 位作者 Gan Li Juan Wang Dongni Cao Tao Xu Aiqing Jia Yong Tang 《Animal Diseases》 2021年第3期150-161,共12页
Porcine epidemic diarrhea virus(PEDV),as the main causative pathogen of viral diarrhea in pigs,has been reported to result in high morbidity and mortality in neonatal piglets and cause significant economic losses to t... Porcine epidemic diarrhea virus(PEDV),as the main causative pathogen of viral diarrhea in pigs,has been reported to result in high morbidity and mortality in neonatal piglets and cause significant economic losses to the swine industry.Rapid diagnosis methods are essential for preventing outbreaks and transmission of this disease.In this study,a paper-based lateral flow immunoassay for the rapid diagnosis of PEDV in swine fecal samples was developed using stable color-rich latex beads as the label.Under optimal conditions,the newly developed latex bead-based lateral flow immunoassay(LBs-LFIA)attained a limit of detection(LOD)as low as 10^(3.60) TCID_(50)/mL and no cross-reactivity with other related swine viruses.To solve swine feces impurity interference,by adding a filtration unit design of LFIA without an additional pretreatment procedure,the LBs-LFIA gave good agreement(92.59%)with RT-PCR results in the analysis of clinical swine fecal samples{n=108),which was more accurate than previously reported colloidal gold LFIA(74.07%)and fluorescent LFIA(86.67%).Moreover,LBs-LFIA showed sufficient accuracy(coefficient of variance[CV]<15%)and stable(room temperature storage life>56 days)performance for PEDV detection,which is promising for on-site analysis and user-driven testing in pig production system. 展开更多
关键词 Porcine epidemic diarrhea virus Latex beads lateral flow immunoassay Sample pretreatment Filter pad
下载PDF
Effect of drip irrigation circuits design and lateral line length on: II-flow velocity and velocity head
16
作者 Mohamed Tayel David Lightfoot Hani Mansour 《Agricultural Sciences》 2012年第4期531-537,共7页
The objectives of the work were to study the effect of drip irrigation circuits (DIC) and lateral lines lengths (LLL) on: Flow velocity (FV) and velocity head (VH). Laboratory tests were conducted at Irrigation Device... The objectives of the work were to study the effect of drip irrigation circuits (DIC) and lateral lines lengths (LLL) on: Flow velocity (FV) and velocity head (VH). Laboratory tests were conducted at Irrigation Devices and Equipments Tests Laboratory, Agricultural Engineering Research Institute, Agriculture Research Center, Giza, Egypt. The experimental design of laboratory experiments was split in randomized complete block design with three replicates. Laboratory tests carried out on three irrigation lateral lines 40, 60, 80 m (LLL1, LLL2;LLL3) under the following three drip irrigation circuits (DIC): a) one manifold for lateral lines or closed circuits with one manifold of drip irrigation system (CM1DIS);b) closed circuits with two manifolds for lateral lines (CM2DIS), and c) traditional drip irrigation system (TDIS) as a control. Concerning FV values, DIC and LLL treatments could state in the following ascending orders: TDIS 1DIS 2DIS and LLL1 2 3, respectively. FV varied from 0.593 m·sec–1 to 1.376 m?sec–1. i.e FV –1 and this is necessary to avoid the effect of water hammer in the main and sub-main lines, but in lateral line, it can cause silt and clay precipitation problems. The differences in FV among DIC and LLL were significant at the 1% level. The effect of interaction: DIC X LLL on FV values, were significant at the 1% level. The maximum and minimum values of FV were noticed in these interactions: CM2DIS X LLL3 and TDIS X LLL1, respectively. The following ascending orders TDIS 1DIS 2DIS and LLL1 2 3 expressed their effects on VH respectively. Differences in VH among DIC and/or LLL were significant at the 1% with few exceptions. The effects of interactions: DIC X LLL on VH were significant at the 1% level in some cases. The maximum and minimum values of VH were found in the interactions: CM2DIS X LLL3 and TDIS X LLL1, respectively. 展开更多
关键词 DRIP IRRIGATION Circuit laterals flow HEAD VELOCITY
下载PDF
Determination of <i>Salmonella pullorum</i>with Nanoparticles Immune Based Lateral Flow Strip Assay
17
作者 Bin Wu Xiuyun Zhang +2 位作者 Wei Pan Lin Zhang Fan Zhang 《Advances in Microbiology》 2015年第5期364-369,共6页
The isolation and culture of conventional detection method of salmonella can not meet the testing requirements of quick and easy detection at the grassroots level. In this study, we prepare the fluorescent nanoparticl... The isolation and culture of conventional detection method of salmonella can not meet the testing requirements of quick and easy detection at the grassroots level. In this study, we prepare the fluorescent nanoparticles as a marker, covalently conjugate with monoclonal antibodies of Salmonella pullorum. The whole Salmonella pullorum antigen and goat anti-mouse antibody sprayed on the nitrocellulose membranes are used as test line and control line. The fluorescence nanoparticles immune based lateral flow strips are made according to the principle of antigen-antibody immune response. The test strips may interpret results within 30 min. The results of the salmonella A, S. agona, S. chester and S. arechavaleta are positive, including, S. agona for weakly positive. After analysis, it is found that in addition to the salmonella of group A, the other positive salmonella are in group B. But it is negative of S. derby, S. rissen, and other 6 kinds of salmonella, with good specificity. The fluorescence nanoparticles immune based lateral flow strips are a little of sample can be detected fast, easily, inexpensive, easy to universal without professional technical personnel detection method. It provides a new detection method for the detections of Salmonella pullorum. 展开更多
关键词 Monoclonal Antibody NANOPARTICLES Fluorescence NANOPARTICLES IMMUNE BASED lateral flow Strips SALMONELLA pullorum
下载PDF
Hydrodynamic behaviour of the lateral flow biological aerated filter
18
作者 何强 王胤 +2 位作者 方俊华 张红津 许静 《Journal of Central South University of Technology》 EI 2006年第4期412-416,共5页
Pulsed signal experiment was carried out to determine the hydrodynamic behaviours of lateral flow biological aerated filter(LBAF). With the analysis of experimental results, LBAF is viewed as an approximate plug flow ... Pulsed signal experiment was carried out to determine the hydrodynamic behaviours of lateral flow biological aerated filter(LBAF). With the analysis of experimental results, LBAF is viewed as an approximate plug flow reactor, and hydraulic retention time distribution function was derived based on LBAF. The results show that flow rate and aeration strength are two critical factors which influence flow patterns in LBAF reactor. The hydrodynamic behaviour analysis of LBAF is the theoretical basis of future research on improving capacity factor and developing kinetic model for the reactor. 展开更多
关键词 lateral flow biological aerated filter flow pattern experiment hydraulic retention time distribution function
下载PDF
Performances of lateral flow biological aerated filter in treating domestic wastewater
19
作者 张红晶 《Journal of Chongqing University》 CAS 2006年第3期152-156,共5页
A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The resu... A new biological aerated filter?lateral flow biological aerated filter(LBAF) is developed. The effects of air/water ratio, hydraulic loading and the length of LBAF on pollutants removal efficiency are tested. The results show that under optimal technological conditions when hydraulic loading is 0.43 m3 m?2 h?1 and air/water ratio is 10:1, the average removal efficiencies of COD, SS, NH3-N, and TN reach 88.01%, 95.18%, 78.97% and 52.58%, respectively. An LBAF has a large pollutants handling capacity; is less liable to be blocked, and has a longer operation cycle in comparison with a traditional BAF. 展开更多
关键词 lateral flow biological aerated filter domestic wastewater ZEOLITE
下载PDF
Performance of alpha-defensin lateral flow test after synovial fluid centrifugation for diagnosis of periprosthetic knee infection
20
作者 Rodrigo Calil Teles Abdo Riccardo Gomes Gobbi +6 位作者 Chilan Bou Ghosson Leite Sandra Gofinet Pasoto Elaine Pires Leon Ana Lucia Lei Munhoz Lima Eloisa Bonfa José Ricardo Pécora Marco Kawamura Demange 《World Journal of Orthopedics》 2021年第8期565-574,共10页
BACKGROUND The quantitative alpha-defensin enzyme-linked immunosorbent assay(ELISA)demands a prior synovial fluid centrifugation,whereas this processing is not routinely required prior to the alpha-defensin lateral fl... BACKGROUND The quantitative alpha-defensin enzyme-linked immunosorbent assay(ELISA)demands a prior synovial fluid centrifugation,whereas this processing is not routinely required prior to the alpha-defensin lateral flow test.AIM To evaluate whether a prior synovial fluid centrifugation could lead the lateral flow performance to achieve comparable results to ELISA during periprosthetic joint infection(PJI)diagnosis.METHODS Fifty-three cases were included in this study:22 classified as PJI and 31 classified as aseptic cases,according to Musculoskeletal Infection Society 2013 criteria.Synovial fluid samples were submitted to centrifugation,and the supernatant was evaluated by ELISA and lateral flow tests.The sensitivity(SE),specificity(SP)and accuracy of each method were calculated as well as the agreement between those two methods.RESULTS In all of the 31 samples from aseptic patients,alpha-defensin ELISA and lateral flow tests showed negative results for infection.Regarding the 22 infected patients,the lateral flow test was positive in 19 cases(86.4%)and the ELISA was positive in 21(95.5%).Sensibility,SP and accuracy were,respectively,86.4%(95%CI:65.1%-97.1%),100%(95%CI:88.8%-100%)and 93.2%(95%CI:82.8%-98.3%)for the lateral flow test and 95.5%(95%CI:77.2%-99.9%),100%(95%CI:88.8%-100%)and 98.1%(95%CI:89.9%-100%)for ELISA.An agreement of 96.2%between those methods were observed.No statistical difference was found between them(P=0.48).CONCLUSION Alpha-defensin lateral flow test showed high SE,SP and accuracy after a prior synovial fluid centrifugation,achieving comparable results to ELISA.Considering the lower complexity of the lateral flow and its equivalent performance obtained in this condition,a prior centrifugation might be added as a valuable step to enhance the PJI diagnosis. 展开更多
关键词 Alpha-defensin Alpha-defensin lateral flow Periprosthetic joint infection
下载PDF
上一页 1 2 36 下一页 到第
使用帮助 返回顶部